| Sl. No. | Item Description |
| 1 | Dismantling and taking down security light, street light, hanger light, flood light and high mast lights of any type at any height fittings such asHPSV/HPMV/MH/LED light any make and any type/size etc. AC 230 volts any wattage from pole/wall roof top/hanger roof including washing/cleaning of perplex cover inspection for location of faultand replacing of defective spare/parts required for smooth functioning, tighting of electric connection complete and assembling and reconnecting all as per site requirment all as specified and directed. Note: Defective spare/ part of relevant light fitting shall be measured and paid separately under relevant item as supply only here in after. |
| 2 | Supply only LED electronic driver/adeptor/SPDfor48 watt LEDsecurity light fitting of existing makeall as specified and directed. |
| 3 | Supply only LED electronic driver/adeptor/SPDfor60 watt LEDsecurity light fitting existingmakeall as specified and directed. |
| 4 | Supply only LED electronic driver/adeptor/SPDfor70/72 watt LEDsecurity light fitting existing makeall as specified and directed. |
| 5 | Supply only LED electronic driver/adeptor/SPDfor90 watt LEDsecurity light fitting existing makeall as specified and directed. |
| 6 | Supply only LED electronic driver/adeptor/SPDfor120 watt LEDsecurity light fitting existing makeall as specified and directed. |
| 7 | Supply only LED electronic driver/adeptor/SPDfor150 watt LEDflood light fitting existing makeall as specified and directed. |
| 8 | Supply only LED electronic driver/adeptor/SPDfor200 watt LEDflood light fitting existing makeall as specified and directed. |
| 9 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locatingfault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed. |
| 10 | Decription all as per Item Ser No 9.00 above but depth exceeding 1.5 metre and not exceeding 3.0 metre. |
| 11 | Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed. |
| 12 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 13 | Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cmsdeep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed. |
| 14 | Supply and lay bricks, common burnt clay, sub class \"B\", old size, laid in vertical direction to cable as cable protection complete all as specified and as directed. |
| 15 | Description all as per Item Ser No 14.00 here in before but except bricks, all as specified and directed.Note:- Old bricks retrieved from Item Ser No 18.00 here in after shall be re- used. |
| 16 | Material and labour PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit and foundation etc. complete all as specified and directed. |
| 17 | Material and labour cement concrete (1:3:6) type C-1using 20mm graded crushed stone aggregate as in coping of pole and strut, stayaround the poleetc complete all as specified and directed. |
| 18 | Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete as directed by Engineer-in-Charge (Excavation/earth work & sand cushioning, bricksandjoint shall be measured & paid for separately). |
| 19 | Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc. |
| 20 | Supply and laying, connecting and testing XPLE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc, Note : (i) Earth work, sand , bricks removing , returning filling Aluminium thimbles/lugs will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates(iii)All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 21 | Description all as per Ser Item No 20.00 here in before but of 3.5 core 25 Sqmm |
| 22 | Description all as per Ser Item No 20.00 here in before but of 3.5 core 35 Sqmm |
| 23 | Description all as per Ser Item No 20.00 here in before but of 3.5 core 50 Sqmm |
| 24 | Description all as per Ser Item No 20.00 here in before but of 3.5 core 70 Sqmm |
| 25 | Description all as per Ser Item No 20.00 here in before but of 3.5 core 95 Sqmm |
| 26 | Description all as per Ser Item No 20.00 here in before but of 3.5 core120 Sqmm |
| 27 | Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed. |
| 28 | Supplying and fixing in replacement oflight gradegalvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitablemild steel clamps , bolts , nuts and washersall as specified and directed. Note:- Excavation & earth work shall be measured and paidfor separately under appropriate item of this schedule. |
| 29 | All as per Item No 28.00 here-in-before but of size 50 mm bore. |
| 30 | Dismantling and taking out of old unserviceable PCC pole any type and size after disconnecting all eletrical connection incl clearance of site complete all as the direction of Engr-in-Charge. |
| 31 | Supply and erection of PCC pole 9.0 mtr long in true vertical position 102x172 mmm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-Charge. Note: Earth work and PCC shall be measured and paid seperately.(ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost. |
| 32 | Dismantling and taking out of old unserviceable steel pole any type and size after disconnecting all eletrical connection incl clearance of site complete all as the direction of Engr-in-Charge. |
| 33 | Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, 09 meter long, providing synthetic enamel aluminium paint two coats over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip, incl arrangement of galvanised/Mild steel circular lantern carriage arrangement suitable for 5 luminares symetrically on steel tubular poles complete all as specified and directed by Engineer-in-Charge. Note: (i) Earth work and PCC shall be measured and paid seperately.(ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost. |
| 34 | Supply and fixing in replacement stay assembly complete with all accessories, such as stay plate 230x230x6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc all as per electrical plate No 1 or SSR Part-1 and completed all as directed.Note: Loop type insulator, stay clamps, excavation and concrete measured and paid separately. |
| 35 | Material and lobour in replacement Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mmx 140mm, clearance of hole 25.5 mm, Complete all as specified and directed. |
| 36 | Material and lobour in replacement shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Material and lobour in replacement pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm hight and 65 mm dia with GI spindle two washer and one GI nut complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Dismantling and taking down old unserviceable ACSR conductor incl cutting, welding complete all as per direction of Engineer-in-Charge. |
| 39 | Material and lobour aluminium conductor steel reinforced (ACSR) conductor of size 6/1 x 2.59(Weasel) and6/1 x 2.11 (Squirrel) ISI marked as LT over head lines on poles, including stretching, tightining of poles insulator with winding wire of suitable size all as specified and directed by Engineer-in-Charge. |
| 40 | Dismantling andtaking down old unserviceable cross-arms M.S. channel or angle iron sections etc. incl cutting, welding complete all as per direction of Engineer-in-Charge. |
| 41 | Material and lobour in replacement cross arms,bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape of size as indicated including one primer coat, one under coat and one finishing coat of alluminium paint complete all as specified and directed. |
| 42 | Supply and fixing in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4.0 x 10-50 Sqmm complete all as directed by Engr-in-Charge. |
| 43 | Supply and fixing in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm complete all as directed by Engr-in-Charge. |
| 44 | Supply and fixing in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-300 Sqmm complete all as directed by Engr-in-Charge. |
| 45 | Supply and fixing in replacement straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4 x 25-50 Sqmm complete all as directed by Engr-in-Charge. Note. Earth work will be measured and paid seperately. |
| 46 | Supply and fixing in replacement straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm complete all as directed by Engr-in-Charge. Note. Earth work will be measured and paid seperately. |
| 47 | Supply and fix inreplacementof Lithium based Energy Efficient Integrated Solar Street Light 24Watt” in Single FRP body duly Polyurethane coating (Camouflage colour) , encases with Monocrystalline Solar PV Panel of 53/55 WP, Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Colour Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+) 55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required: short circuit, overload, reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant including 6 mtr pole, clamp, nuts, bolts and necessary earth work and PCC works complete all as specified and directed. |
| 48 | Dismantling andtaking down old u/s earthing and material and labour earthing complete with galvanisedearth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m belowground level with top edge of the earthplate not less than 1.5m belownormal groundlevel, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore (light grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe (light grade) for watering and 40mm bore GIprotection pipe, funnel, wire mesh,cast iron cover andframe etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. |
| 49 | Dismantling andtaking down old u/s earthing andmaterial & labour earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. |
| 50 | Supply and fixing in replacement MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 51 | Supply and fixing in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 52 | Supply and fixing in replacement MCCB TPN 160 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 53 | Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 54 | M&L for Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight throughjoint of size 70-300 Sqmm.Note: (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges demed to be included in the quoted rate. (b)Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate. (c)Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will lived Rs 500/ per hour. (d)Straight through joint for cable, 95 to 185, sqmm and Labour charges including excavation and making joint deemed to be including in quoted rate. |
| 55 | Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS completeas per direction of Engr-in-Charge. |
| 56 | Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 3 line as per IS completeas per direction of Engr-in-Charge. |
| 57 | Re-streching of loose over head ACSR conductor of any type including GI wire and repair of the broken conductors andaddingnew length( if required) in placeof old and burnt conductor of any size on existing poles with proper sagging including winding wire all as specified.(Old conductor shall be reused after repairing broken length of conductor all as directed by Engineer-in-Charge) .Note:- Five lines together will bemeasured as one span from pole to pole. |
| 58 | Material and labour inreplacement aluminium terminals (thimbles) after cutting the worn out/faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugsincluding crimping with crimping tools in the existing LT cable 25 Sqmm 4 core upto 50 Sqmm 4 core including necessary connectionall as specified and directed. |
| 59 | Description all as per Ser Item No 58 above but size of LT cable 70 Sqmm 3.5 core upto 120 Sqmm 3.5 core. |
| 60 | Description all as per Ser Item No 58 above but size of LT cable 150 Sqmm 3.5 core upto 300 Sqmm 3.5 core. |
| 61 | Material and labour for shifting heavy items/excavation/cleaning areas/cleaning site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete, all as specified and as directed. |
| 62 | Material & Labour for cleaning and repair of LT panel of any type and any size including removing rusted particles and dust, tightening nut, bolts welding and painting on complete panel one coat of synthetic enamel aluminium paint including stand complete all as directed.Note: (i)Cost of marking description on the front door as per direction of Engineerr-in-Charge is incl in quoted rate. (ii)Cost of misc items like copper cable, lugs thimbles etc if required are included in quoted rates. (iii) Cost of welding works such ashinges, locking arrangement, door and angles are included in qouted rates. |
| 63 | Material & Labour for surface cleaning of LT steel tubular poles 9 mtrs long including removing rusted particles painting withone coat of synthetic enamel aluminium including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 Mtr height starting with black strip using synthetic enamel paints including repairing and painting on coping with cement base white paint one coat complete all as directed.Note: (i)The quoted rate shall include making of numbers on each LT pole as per direction of Engr-in-Charge. (ii)The quoted rates shall include the repairing of coping with cement/PCC and making good. |
| 64 | Material & Labour one coat cement base paint on PCC pole 9 mtr includingblack & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide on cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with cement base white paint complete all as directed.Note: (i)The quoted rate shall includes making of numbers on each LT pole as per direction of Engineer-in-Charge.(ii)The quoted rates shall including the repairing of coping with cement/PCC. |
| 65 | Material and labour for spraying chemical (Round up) on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge |
| 66 | Supply and fixing in replacementOn load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply and fixing in replacement On load change over switch with sheet steel Enclosure 415 V, 4 pole, 200 Amps capacity fixed on walls/MS frame/pole/LT panel for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed by Engr-in-Charge. |
| 68 | Material and labour Chemical spray (DC>2.26 having container 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleaness etc complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fixing in replacement rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note : PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates. |
| 70 | Supply and fixing in replacement 1100 volts grade heavy duty, PVC insulated cable 3 core 2.5 sqmm copper cable or passing through PVC conduits including electrical connection suitable size of lugs,nuts and bolts complete all as specified and directed. |
| 71 | Supply and fixing in replacement 1100 volts grade heavy duty, PVC insulated cable 5 core 2.5 sqmm copper cable or passing through PVC conduits including electrical connection suitable size of lugs,nuts and bolts complete all as specified and directed. |
| 72 | Supply and fixing in replacement or passing through PVC conduit pipe single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs,nuts and bolts complete all as specified and directed. |
| 73 | Supply and fixing in replacement or passing through PVC conduit pipe single core PVC unsheathed multi stranded copper cable (FRLS) 2.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs,nuts and boltscomplete all as specified and directed. |
| 74 | Supply and fixing in replacementn junction box shall be insulated and made out of polycarbonate with glass fiber reinforced. The size in mm should be not less then 225 X 295 X 112 cat. part no KF350B. The polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The JB shall be rated for degree of Ingress protection IP 66/67 in accordance with IEC 60529. The gasket material shall be polyurethane and the gasket shall be internally embedded. The JBs shall be complies with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670 –22 & IEC 60670 – 2-5. The manufacturer of junction box shall submit a copy of IEC certificate. For better safety the polycarbonate shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 Part 3, UL subject 94 for flammability V-2. It should be tested at glow wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 including 6 amp MCB and mounting clamp complete all as specified and directed. |
| 75 | Supply & fixing in replacementAutomatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Three phase, 25 Amps per phase, MCB rating 32 Amp, max load 8-12 kw incl circuit copper wire 10 sq.mm.Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is = 60 Lux and for switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Madel :Swadeep-02EC-8kW3P-VMS complete all as specified and directed.Note:(i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates.(ii)The sensor must have the warranty of min of 2 years. (iii)The test certificate and warranty cirtificate to be provided by supplier.(iv)Cost of marking description on the box is incl quoted rate. |
| 76 | Supply & fixing in replacementAutomatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). single phase, 25 Amps per phase, MCB rating 40 Amp, max load 5-8 kw incl circuit copper wire 10 sq.mm.Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is = 60 Lux and for switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Note: (i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii)The sensor must have the warranty of min of 2 years. (iii)The test certificate and warranty cirtificate must be provided by supplier.(iv)Cost of marking description on the box is incl quoted rate. |
| 77 | Supply & fixing in replacement Integral LED Flood light Luminaries 80 Watts consisting of suitable number of LEDs andmounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover,IP 66 protection suitable for mast light mounting, 5700K,LED efficiency >130 lm/Watt and system efficiency 110 lM/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50º C,built in surge protection of more than 10 KV, Confirm the tests from auth labs: LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting, welding, drilling holes, nut bolts, washer complete all as directed by Engineer-in-Charge. |
| 78 | Supply & fixing in replacement Integral LED Flood light Luminaries 150 Watts consisting of suitable number of LEDs andmounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover,IP 66 protection suitable for mast light mounting, 5700K,LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV ,Confirm the tests from auth labs :LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-Charge. |
| 79 | Supply & fixing in replacement Integral LED Flood light Luminaries 200 Watts consisting of suitable number of LEDs andmounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover,IP 66 protection suitable for mast light mounting, 5700K,LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV ,Confirm the tests from auth labs :LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-Charge. |
| 80 | Supply & fixing in replacement LED street light fitting 60 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10º C to 50º C,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs: LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting, welding, drilling holes, nut bolts, washer complete all as directed by Engineer-in-Charge.Note:-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to streetshall be measured and paidfor separately. |
| 81 | Supply & fixingin replacement LED street light fitting70 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K,LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range-10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs :LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular poleincl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note:-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to streetshall be measured and paidfor separately. |
| 82 | Supply & fixingin replacement LED street light fitting90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K,LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range-10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs :LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular poleincl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to streetshall be measured and paidfor separately. |
| 83 | Supply, installing, testing & commissioning in replacement outdoor type cubical panel board of size 1.5mX.9mX.5m, outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform block type 60 cm above ground level and 30 cm grouting in ground,frame factory fabricated with front and back openable double door system and cable alloy(Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open ablewith arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl AL bus bar of 600 A , tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket/gland to make it dust/vermin proof and general construction confirming to IS:8623/93 complete all as directed andcomprising of the following :-(a) Supply and fixingMCCB400 Amps, 36 KA 4 pole 415 Volts AC, adjustable type (incoming)-01 No.(b) Supply and fixing MCCB160 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type (Outgoing)-02 Nos.(c) Supply and fixing MCCB100 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type (Outgoing)-01 Nos.(d) Supply and fixing MCCB63 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type(Outgoing)-03 Nos.(e) Supply and fixing MCB32 Amp, 415 volt, TPN, breaking capacity 16 KA , adjustable type(Outgoing)-02 Nos(f) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos(g) Digital Ammeter of range 0-500 A,auxiliary voltage 230 volts with selector switch -01 Nos(h) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 No(j) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates. |
| 84 | Supply, installing, testing & commissioning in replacement outdoor type cubical panel board of size 1.4mX.9mX.5m,outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front and back openable double door system and cable alloy(Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open ablewith arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl AL bus bar of 400 A , tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 complete all as directed and comprising of the following:- (a) Supply and fixingMCCB250 Amps, 25 KA 4 pole 415 Volts AC, adjustable type (incoming)-01 No.(b) Supply and fixing MCCB100 Amp, 415 volt, 4 pole, breaking capacity 25 KA, adjustable type (Outgoing)-01 No.(c) Supply and fixing MCCB63 Amp, 415 volt, 4 pole, breaking capacity 16 KA , adjustable type(Outgoing)-03 Nos(d) Supply and fixing MCB32 Amp, 415 volt, TPN, breaking capacity 16 KA , adjustable type (Outgoing)-02 Nos(e) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (f) Digital Ammeter of range 0-300 A,auxiliary voltage 230 volts with selector switch -01 Nos(g)Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 No(h)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates. |
| 85 | Supply, installing, testing & commissioning in replacement outdoor type cubical panel board of size 1mX.7mX.5m,outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alloy(Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open ablewith arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl AL bus bar of 300 A, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 complete all as directed and comprising of the following:- (a) Supply and fixingMCCB160 Amps, 25 KA 4 pole 415 Volts AC, adjustable type (incoming)-01 No.(b)Supply and fixing MCCB63 Amp, 415 volt, 4 pole, breaking capacity 25 KA, adjustable type (Outgoing)-03 Nos.(c)Supply and fixing MCB32 Amp, 415 volt, TPN, breaking capacity 16 KA , adjustable type(Outgoing)-04 Nos(d)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (e) Digital Ammeter of range 0-500 A, auxiliary voltage 230 volts with selector switch -01 Nos(f) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 No(g) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.Notes: For item Ser No. 83 to 85(i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694.(iii) Panel drawing shall be got approved before placing of orderfrom Engineer-in-Charge/GE.(iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panles through gland.(vi) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate. |
| 86 | Supply, installing, testing & commissioning in replacement outdoor type cubical LT feeder pillar panel box size 0.6Mx0.6Mx40Cm with out door type cubical panel board outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front and rear openable double door system and cable alloy(Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/openable by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl AL bus bar of 200 A , tested at factory approved from CPRI forfactory fabricatedfollowed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprisingincludingrelay, contactor and push botton for smooth operation of motor for high mast lightcomplete all as specified and directed of the following :-a) incoming MCCB100 Amps, 25 KA 4 pole 415 Volts AC, adjustable type, -01 No.(b) outgoing MCCB63 Amp, 16 KA, 4 pole 415 volt AC, adjustable type -01 Nos.(c) outgoing MCB32 Amp, 16 KA , TPN 415 voltAC -02 Nos(d)Relay and contactor with push botton suitablefor existing motor upto 5 HP for smooth operation of high mast lights.(d)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (e) Digital Ammeter of range 0-200 A,auxiliary voltage 230 volts with selector switch -01 Nos(f) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 No(g) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates. |
| 87 | Supply and fixing in replacement cable route indicator or cable joint mark for 1100 volts made out of mild steel 100mm dia 6mm thick plate welded to 40 x 40 x 6mm angle iron 50 cm long embeded in PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) block of size of 150mm x 200mm x 200mm including applying two coats of synthetic enamel paint over a coat of redoxide primer on steel surfaces complete all as specified and directed by Engineer-in-Charge. |
| 88 | Supply and fixing in replacement bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint two coats over one coat of red oxide primer to the bracket all as specified and as directed. |
| 89 | Supply and fixing in replacement MS clamp suitable for holding street light bracket on steel/PCC polemade out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick - 02 No for each including painting with two coats aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed |
| 90 | Material and Labour epoxy brushable insulated compound used as insulation material in electrical poles, stays and other electrical appliances etc, the inslulation compound to produce void free insulation around the components including removing rusted particles, painting with two coats of epoxy brushable insulated compound over a coat of red oxide primer complete all as specified and directed.Note: The quoted rate shall be included for all types of adhesive which will be used in insulated compound to ready for paint. |
| 91 | Material and Labour insulation cover for overhead conductor of medium voltage wrap around line cover to provide retrofit insulation for overhead conductors to prevant electrical fault caused by trees or wildlife coming in the contact of distribution lines from high quality non tracking polyolefin material. Installation shall be easy by using the split insulation tube tool complete all as specified and directed.Note:Accessories of insulation for OH Lines shall be included in quoted rates. |
| 92 | Note:-Amount of credit ofRs. 157085.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender. |