Indian Oil Corporation Limited-IOCL has published Amc For Electrical And Tandi Maintenance Amc For Electrical And Tandi Maintenance. Submission Date for this Tender is 05-04-2022. Electrical Maintenance Tenders in paradip Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Variable Part: ARC PRRPL |
2 | "LAYINGOFLTPOWER/CONTROL/ SIGNAL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES IN TRENCHES: Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables of following sizes in pre-excavated cable trenchor existing trench / RCC or Hume or Stoneware or Metal pipe / masonry duct, fixing of number tags ( if required), testing plus tran sportation from stores to site, unpacking, straightening, dressing of cable and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost." |
3 | Overall diameter upto 35 MM |
4 | Overall diameter > 35 MM but upto 55 MM |
5 | Overall diameter >55 MM but upto 75 MM |
6 | "HT CABLE LAYING IN TRENCHES: Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed/ XLPE HT power cables of voltage grade exceeding 1.1 KV but not exceeding 33 KV of following sizes in pre- excavated cable trench or existing trench / RCC orHume or Stoneware or Metal pipe / masonry duct, fixing of number tags ( if required), testing plus transportation from stores to si te, unpacking, straightening, dressing of cable and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost." |
7 | Overall diameter > 75 MM |
8 | "TEMPORARY CABLE LAYING ON SURFACE: Temporary laying and fixing of LT power/control/telephone cables onsurface as required including carriage, handling, testing, cutt ing, sealing, fixing with clamps / cleats etc., transporation of cable from stores to site and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawing, specification and direction of the Engineer -in-charge. NOTE: 1) Cables will be supplied by the Owner free of cost." |
9 | Overall diameter upto 35 MM |
10 | "EXCAVATION OF EARTH FOR CABLE / PIPE LAYING FOR ELECTRICAL WORK: Excavation of earth for cable trenches / laying of G.I. pipes for cable work in all types of soils including saturated soil upto a m ax. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers n ot exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all comp lete with labour and materials as per standards, drawings, specifications and directions of Engineer-in- charge." |
11 | "SFI OF GI CABLE TRAY (INCL. COST OF TRAY) Supply ,fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and / or fix to steel / RCC columns, beams, or any other structure members with MS suspenders, angles, channels etc. complete as per the direction of Engineer-in-Charge" |
12 | 100 mm x 25 mm x 2 mm |
13 | "LT CABLE END TERMINATION FOR ARMOURED PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCLUDING COST OF GLANDS & LUGS) Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell"s or approved equivalent) , wherever specified, providing aluminiumlugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagg ing with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge" |
14 | 3 x 10 sqmm |
15 | 3 x 25 sqmm |
16 | 3 x 70 sqmm |
17 | 3 x 185 sqmm |
18 | 3 x 400 sqmm |
19 | 4 X 4 Sqmm |
20 | 4 x 16 sqmm |
21 | "LTSTRAIGHTTHROUGH CABLE JOINTFOR ARMOUREDPVCINSULATEDCABLE(INCLUDING COST OF JOINT KIT OF HEAT SHRINKABLE TYPE) Making straight through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, strippi ng of cable insulation, including supply of heat shrinkable TUBULAR straight through cable jointing kit of Raychem / CCI / approved equivalent make with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer in- charge." |
22 | 3 / 3.5 / 4 x 10 sqmm |
23 | 3 / 3.5 / 4 x 16 sqmm |
24 | 3 / 3.5 / 4 x 25 sqmm |
25 | 3 / 3.5 / 4 x 70 sqmm |
26 | 3 / 3.5 / 4 x 185 sqmm |
27 | 3 / 3.5 / 4 x 400 sqmm |
28 | "11KV(E)/(UE)/6.6KV(UE)HEATSHRINKABLE STRAIGHTTHROUGHPVC/XLPECABLEJOINTING (INCLUDING COST OF JOINTING KIT): Making straightthroughcablejointforpower (PVC/XLPE)armouredcableandfollowingsizesand gradeincl udingcutting,strippingofcableinsulationall complete with labourincluding travel,transportation, boarding andlodging of the cable jointer and materialsexcludingcostofjointingkitasperstandard and direction of the Engineer-in-Charge." |
29 | 3 x 120 sqmm |
30 | 3 x 240 sqmm |
31 | 3 x 400 sqmm |
32 | "11 KV(E) / (UE) /6.6KV(UE) HEAT SHRINKABLE INDOORPVC/XLPECABLEENDTERMINATION (INCLUDING COST OF END TER MINATION KIT) Providing end termination of power cable including cutting, stripping, providing & fixing of lugs, cable i nsulation,providing&glandingsingle/double compression heavy duty brass cable gland conforming to IS-12943 ,providing aluminiumlugs, crimping/soldering, as necessary, restoration of insulation/ clamping of cable, tagging with aluminium t ag,earthing of armour, connection totheequipmentterminalsetc.allcompletewithlabour including travel,transportation, boarding and lodging ofthecablejointerandmaterialsasperstandardand direction of the Engineer-in-Charge." |
33 | 3 x 185 sqmm |
34 | 3 x 240 sqmm |
35 | 3 x 400 sqmm |
36 | "EXTRA FOR PROVIDING COPPER LUGS Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the followin g sizes." |
37 | 1.5 sqmm |
38 | 2.5 sqmm |
39 | 4 sqmm |
40 | 6 sqmm |
41 | 10 sqmm |
42 | 25 sqmm |
43 | 35 sqmm |
44 | 50 sqmm |
45 | "EXTRA FOR PROVIDING ALUMINIUM LUGS: Supply ofaluminiumtubeterminalheavyduty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the following sizes." |
46 | 2.5 sqmm |
47 | 4 sqmm |
48 | 6 sqmm |
49 | 10 sqmm |
50 | 16 sqmm |
51 | 25 sqmm |
52 | 35 sqmm |
53 | 50 sqmm |
54 | 70 sqmm |
55 | 95 sqmm |
56 | 120 sqmm |
57 | 185 sqmm |
58 | 240 sqmm |
59 | 400 sqmm |
60 | "EXTRA FOR PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS: Supplyof CMRS/CCEapprovedflameproofdouble compression(brass)cableglandforfollowingoverall cable sizes as p er directions of Engineer-in-Charge." |
61 | 10.0 to 16.0 mm |
62 | 16.5 to 18.0 mm |
63 | 18.5 to 20.0 mm |
64 | 20.5 to 23.0 mm |
65 | 23.5 to 26.0 mm |
66 | 26.5 to 30.0 mm |
67 | 30.5 to 33.0 mm |
68 | 33.5 to 37.0 mm |
69 | 37.5 to 41.0 mm |
70 | 41.5 to 46.0 mm |
71 | 46.5 to 52.0 mm |
72 | 52.5 to 60.0 mm |
73 | "EARTHING WITHGI STRIP: ProvidingEarthingwithGIstripofthefollowingsizes includingsupplyandlayingofGIstripandconnecting consu mables,allcompletewithlabourandmaterialsas per direction of Engineer-in-Charge." |
74 | 50 X 6 MM GI STRIP |
75 | 25 X 5 MM GI STRIP |
76 | "BARE STRANDED COPPER FLEXIBLE EARTHING: EARTHING WITH BARE STRANDED COPPER FLEXIBLE CONDUCTOR Earthing with bare stranded tinned copper flexible conductor including providing and connecting equipments with earth busbar,supply and fixing of copper stranded wire of following sizes and making connection with equipment by means of GI bolts, nuts, washers,coppe r lugs etc. all complete with labour and materials as per direction of Engineer-in-Charge." |
77 | 16 sqmm |
78 | 70 SQ. MM |
79 | "EARTHING WITH BARE GI WIRE: Earthingwithbare GIwire,providingandconnecting equipments with earth bus bar including supply and fixing of bare GI wi re of following sizes and making connection withequipmentbymeansofGIbolts,nuts,washers, copper lugs etc. all complet e with labour and materials as per direction of Engineer-in-Charge." |
80 | 14 SWG |
81 | EARTHING WITH GI WIRE ROPE |
82 | EarthingwithGIwirerope,providingandconnecting equipment with earth buss bar including supply and fixing of GI wire rop e of following diameter and making connection with equipment by means of GI bolts, nuts, washers, copper lugs etc. all complete withlabour and materials as per direction of Engineer-in-Charge. |
83 | 6 MM |
84 | 10 MM |
85 | 15.875 MM (5/8") |
86 | 25.40 MM (1") |
87 | 36 MM |
88 | 48 MM |
89 | "PROVIDING EARTHING ELECTRODE: ProvidingearthingelectrodeasperIS:3043standard/ drawing/specifications withfollowingsizes medium quality ,Class-B,ITC/KT/JindalmakeGIpipefabricated asperthestandarddrawinganddrivenintheearthpit filledupwithcharcoalorcokedustmixedwithsaltclay (salt 0.5%) including providing inspection chamber as per thedrawingwit hremovableRCC(1:2:4)cover,earth, excavation,backfilling,masonryworketc.allcomplete with labour and materialsas per the direction of Engineer- in-Charge. Charcoal and salt cost will be paid seperately as extra." |
90 | 65 mm dia 3 metre long |
91 | "40 mm dia 4.5 metre long (without charcoal, coke and salt)" |
92 | "SALT AND CHARCOAL FOR PIPE EARTHING: Extraforusingbelowgivensaltandcharcoalforpipe earth electrode as required." |
93 | 64 kg charcoal and 5 kg salt |
94 | 160 kg coke and 5 kg salt |
95 | ALUMINIUM BBC, 4 STRIPS, 300 MM |
96 | "Supplyingandfixingbusbarchamberwith4strips busbars of length 300 mm, made of aluminium alloy or wrought aluminium, su itable for following capacity, complete with all accessories including connections, earthing the body etc. as required." |
97 | 200 amps. |
98 | COPPER BBC, 4 STRIPS, 600 mm. |
99 | "Supplyingandfixingbusbarchamberwith4strips busbars of length 600 mm, made of copper, suitable for capacity complete w ith all accessories including connections, earthing the body etc. as required." |
100 | 100 amps. |
101 | 200 amps. |
102 | 300 amps. |
103 | "Providing and fixing 32 amps. Metal clad, TP&N switch fuse unit, 415/500 volts, without H.R.C. fuses including drilling holes on th e board, connections, earthing the body etc. as required. 1.ISI marked HRC fuses shall be used. 2.TPN of English Electric / L&T / Crompton / Havells / Standard /equivalent make shall be used as per direction of Engineer-in-Charg e." |
104 | Providing and fixing 63 amps. Metal clad, TP&N switch fuse unit, 415/500 volts, without H.R.C. fuses including drilling holes on theboard, connections, earthing the body etc. as required. 1.ISI marked HRC fuses shall be used. 2.TPN of English Electric / L&T / Cro mpton / Havells / Standard make shall be used. |
105 | "SupplyofMCB/Isolator/RCCBoffollowingratingas per direction of Engineer-in-Charge." |
106 | 25 amp modular SPMCB, ‘C’ curve |
107 | "6amps.to32amps.ratings,SPMCB,“C”curve,10KA breaking capacity" |
108 | "6amps.to32amps.ratings,SPNMCB,“C”curve,10KA breaking capacity" |
109 | "6amps.to32amps.ratings,DPMCB,“C”curve,10KA breaking capacity" |
110 | "6amps.to32amps.ratings,TPMCB,“C”curve,10KA breaking capacity" |
111 | "6amps.to32amps.ratings,TPNMCB,“C”curve,10KA breaking capacity" |
112 | "40 amps. to 63 amps. ratings , 3 Pole MCB, “C” curve,10 KA breaking capacity" |
113 | "40 amps. to 63 amps. ratings , 4 Pole MCB, “C” curve,10 KA breaking capacity" |
114 | 2 Amps, 10kA breaking capacity, "C"Curve |
115 | 40 Amps, 2 Pole Isolator |
116 | 63 Amps, 2 Pole Isolator |
117 | 40 Amps, 4 Pole Isolator |
118 | 63 Amp, 4 Pole Isolator |
119 | 100 Amp, 4 Pole Isolator |
120 | 25 Amp, 2 Pole RCCB, 30mA |
121 | 40 Amp, 2 Pole RCCB, 30mA |
122 | 40 Amp, 2 Pole RCCB, 100mA |
123 | 63 Amp, 2 Pole RCCB, 30mA |
124 | 63 Amp, 2 Pole RCCB, 100mA |
125 | 25 Amp, 4 Pole RCCB, 30mA |
126 | 40 Amp, 4 Pole RCCB, 30mA |
127 | 40 Amp, 4 Pole RCCB, 100mA |
128 | 63 Amp, 4 Pole RCCB, 30mA |
129 | 63 Amp, 4 Pole RCCB, 100mA |
130 | SUPPLY & INSTLN. OF FUSEPARTS |
131 | "Supply, fixing and connection of following KNIFE TYPE HRC fuse link AS PER IS:13703:1993 & IEC 269:1986 of M/S HAVELL/L&T /G EC Astholm/Standard /MDS make or approved equivalentin distribution boardetc.all complete with labour and mate rialsas per direction of Engineer-in-charge." |
132 | KNIFE TYPE HRC FUSE LINK |
133 | 20-32 AMP Size 000 |
134 | 50 AMP Size 000 |
135 | 63 AMP Size 000 |
136 | 80 - 100 AMP Size 000 |
137 | 125 AMP Size 00 |
138 | 125 AMP Size 1 |
139 | 160-200 AMP Size 1 |
140 | PROVIDE SHOCK HAZARD CHART |
141 | SupplyandinstallationofshockhazardchartasperIE Rules1956(Clause-44)completewithframeandglass includi ng necessary clamps, bolts, rawl plugs, etc. breachkingandmakinggoodthewallifrequired.All complete with labour and materials as per specifications. |
142 | PROVIDE CAUTION BOARD AT SUB-STATION |
143 | Supply and installation of "Caution Boards" at sub-stations asperIS2551/uptodateincludingsupplyofnecessary clamps, nut s, bolts and other hardware. All complete with labour and materials as per the direction of the Engineer- in-Charge |
144 | "PROVIDE FIRST-AID BOXES Supply and fixing of First-Aid boxes as per IE Rules, 1956 Clause 43(2), including necessary clamps, bolts, rawl plugs, etc. breachk ing and making good the walls if required. All complete with labour and materials as per the direction of Engineer-in-Charg " |
145 | FIRE BUCKETS AND STAND |
146 | "Supply of floor mounting stand for keeping 4No of fire bucket 1500mmlength,900mmheightmadeoutof40x40x6mm angleironweldedwith4hooksanddulypaintedwithone coatofredleadandtwocoatsofenamelpaintasper direction of Engineer-in-Charge." |
147 | Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity asperIS:2546madeoutof24gaugeGIsheetwithextra handl e at bottom duly painted inside and red out side with printedwithFIREMarkforstandandhookandfilledwith sand and a rranged to existing stand or hook as per direction of Engineer-in-Charge. |
148 | PROVIDE CANOPY IN PUSH BUTTON STATION |
149 | Supply and erection of 250 mm x 380 mm 340 mm deep at top and 120 mm deep at bottom canopies made out of 2 mmthicksheetfor mou ntingon PushButton Stations support to render them weachther proof including fabrication, mechanical assembly and su pply and fixing of screws,nuts,boltsetc.andpaintingwith2coatsof bituminous aluminium synthetic enamel paint over acoat of red oxide primer all complete with labour and materials as per the direction of Engineer-in-Charge |
150 | SUPPLY AND FIXING OF EQUIPMENT IN PANELS |
151 | Supplying anderection ofPushButtonStation/Control Station with MS channel grouted with PCC including excavationalignment,e rection and connection ofPush Button, connection of control cable, earthing including supply and fixing of saddles, nuts, bolts et c. and painting wth two coats of bituminous aluminium paint/synthetic enamel paint over a coat of red oxide primer all complete withlabour and materials as per drawing and the direction of Engineer-in- Charge (Push Button will be supplied by Owner free of cost) |
152 | Supply, fixingand connectionoffollowingequipmentsin panels including small mechanical works and supply of all fixing mater ials. All complete with labour and materials as per the direction of Engineer-in-Charge |
153 | Power Contactor (Upto 2NO + 2 NC)- Above 25 Amp but upto 45 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz TypeMNX45 of L&T or equivalent |
154 | SUPPLY & INSTALLATION OF LED INDICATION LAMPS |
155 | Supply and fixing of led indication lamp in the panels. leds shallbeprovidedwithleakagevoltageprotectionupto 40v. Oper ating voltage shall be 110v / 220v / 230v / ac / dc, Panel cutouts shallbe 22.5 / 25.5 / 30.5 mm. Terminals shal l be shrouded for finger proofing and safety are with captivated washers to hold two lugged (fork / pin) wiresinoneterminal. Jobincludessupplyoflaborand various undry materials required and finally testing of led"s for + following ed"s |
156 | Red / yellow / amber / green / milky white led"s |
157 | Blue led |
158 | Supplying following way,vertical, three pole and neutral, sheet steel, MCB distribution board, 415 V, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, dinbarformounting MCBs(butwithoutMCBsand incomer ) as required as per IS 8623; IS 13032; IEC 61439 3 andas per direction of Engineer-in-Ch arge. |
159 | "4 way (4+4+12), TPN, vertical type, MCB DB,double door, IP-43" |
160 | "8 way (4+4+24), TPN, vertical type, MCB DB,double door, IP-43" |
161 | "12 way (4+4+36), TPN, vertical type, MCB DB, double door, IP-43" |
162 | Supply of accessories for transformers |
163 | "Supply & replacement of OTI as per direction of Engineer-in- Charge." |
164 | "Supply & replacement of Buchholz relay as per direction of Engineer-in-Charge." |
165 | Supply, fixing, installation of Breather Unit without silicagel suitable for upto 750gm silicagel as per direction of Engineer-in-Ch arge. |
166 | Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1000gm silicagel as per direction of Engineer-in-C harge. |
167 | Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1500gm silicagel as per direction of Engineer-in-C harge. |
168 | "Supply & Replacement of silica gel in transformers as per direction of Engineer-in-Charge." |
169 | NUMBERING OF FITTING AND FIXTURES |
170 | Numberingofceilingfan,exhaustfanandflourescent fittings as required. |
171 | REPAINTING OF CEILING FAN |
172 | Repainting ofceiling fan in installed position withone or more coats of spray painting with synthetic enamel paint ofapprovedbrandandmanufacturetogiveaneven shade, including cleaning of surface with detergent etc. as required. |
173 | INSTALLATION OFWALL MONTED FAN |
174 | Fixingofwallmontedfancompletedwithleadinwires and other accessories all complete with labour and mat erials as per direction of the Engineer-in-Charge. (cost of Fans shall be excluded) |
175 | INSTALLATION OF EXHAUST FAN |
176 | Fixing ofexhaust fans on existing opening, complete with leadinwiresandotheraccessoriesallcompletewith labour and materialsas per direction ofthe Engineer-in- Charge. (cost of fans shall be excluded) |
177 | WITH LOUVER SHUTTER/MESH |
178 | WITHOUT LOUVER SHUTTER/MESH |
179 | FLP/IS EXHAUST FAN |
180 | "SUPPLYANDINSTALLATIONOFFLPJUNCTION BOXES" |
181 | Supply, installation, testing & commissioning of following Ex-e/ weather proofjunction boxes of FCG/Baliga make, suitable for ligh ting distribution including supply of steel structure, Elemax terminal blocks suitable for terminating upto 25 sqmm PVC A1. cables, welding, painting etc.All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge. . |
182 | 4-way Ex-e, WP Junction box with threded cover |
183 | 4-way Ex-e, WP Junction box with spigot cover |
184 | 4-way Ex-e, WP Junction box with flanged cover |
185 | "SUPPLY OF LAMPS Supply ofbelow given M/s Philips or equivalent make lamps for installation in lighting fittings / fixtures as per directions of EIC." |
186 | LED tubelight 18W |
187 | REWINDING OF MOTORS |
188 | "Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per t he original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall f inal layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulati ng varnish (Dr-Beck & Co. make & type), providing glass/other types ofsleaves on connection wires from inside motor winding to con nection plate.The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of c ontractor excluding transportation to & from Owner’s works to Contractor"s rewinding shop. which shall be paid seperately ontrip basis.The winding wirewillbeDevi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers asperdecis ion ofEngineer-in- Charge.This also includes repair/replacement of connection platecompletely includinginsulatingsheet, nu ts, bolts, washers and other hardwares as per original specifications. Thisfurtherincludesreplacementofbearings(DE& ND E) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent).This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Full load.The C ontractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & ifany such rewound motor fails within six months, it is to be rewound again by Contractor freeof cost. Allcomplete withlabour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor.Bearing Shall be supp lied by IOCL" |
189 | Motors upto & including 1.5 KW |
190 | Motors above 7.5 KW but upto including 11 KW |
191 | Motors above 75KW but upto including 90 KW |
192 | REWIINDING OF FANS |
193 | "Rewindingofceiling/pedestal/exhaust/aircirculatorfans ofalltypes/sizes/makeincluding1-phaseand3-phase type exha ust fans max. upto 2.2 KW capacity andsupply ofsuperenameledwindingwire(DeviDayalmake,ISI marked insulation materi als required).This also includes replacementofsingle/doublebearingSKFmake/bushes (as per original make) and overhauling of fan and all jobs related to complete this work in totality.This also includes removal of fans from site, installation and commi ssioning after testing of rewound fans and replacement of condenser,ifrequired. This alsoincludes transportati on fromsite after dismantling to Contractor’s workshop and back to site. Note:Contractorhastogiveguaranteeforrewindingof above items for a period ofsix months and ifwinding is burnt aga in within six months of working of fans, it has to berewoundagainfreeofcostofContractor. Theburnt winding shall bekept by Contractor." |
194 | Ceiling/pedestal fans |
195 | Exhaust/air circulators fans. |
196 | Overhauling of exhaust/air circulator fans of various types/sizesmakesanditsbearingsincludingremoval from si te, cleaning, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation fro m site to workplace and back all completewithlabourandmaterialsasperdirectionsof Engineer-in-Charge. |
197 | IncludingsupplyandfixingofbearingsofSKFmake (2Nos. bearings) |
198 | OVERHAULING OF CEILING / PEDESTAL FANS |
199 | Overhauling of ceiling/pedestal fans of various types/sizes/make and its bearings including removal from site, c leaning, greasing after degreasing, assembling and fixinginposition,testingandcommissioningincluding transportation fr om site to workplace and back.All completewithlabourandmaterialsasperdirectionsof Engineer-in-Charge. |
200 | Including supply and fixing of bearings of SKF make and bushes (as per original make) of both sides by Contractor. |
201 | TransportationofLTinductionmotorforrewindingfrom Electrical Workshop at Refinery to Contractor"s works and backtoE lectricalWorkshopatRefinery.Thisincludes arrangingsuitablevehicleforto&frotransportation, unloading&load ingthemotoratrewindingworks.All complete with labour, materials, tools and tackles as per thedirectionofEngineer-i n-Charge.NOTE:Liftingfacility to put the motor in the vehicle at our end will be provided by IOCL for the motors of capacity mor e than 15 KW |
202 | Motor upto 1.5 KW |
203 | Motor above 1.5 KW to 18.5 KW |
204 | Motor above 75 KW to 160 KW |
205 | BRICK WORK IN CABLE TRENCH |
206 | Removal of bricks from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or stacking it at t he edge of the trench and putting it back intothesametrenchorinanewcabletrenchasper drawing/specification withinaleadof50meteresafter theworkiscompletedincludingcompletingtheworkin allrespects with all la bour and materials as per the direction of the Engineer-in-Charge. |
207 | Removal and relaying |
208 | Removal and stacking only |
209 | REMOVAL OF SAND FROM CABLE TRENCH |
210 | Removal of sand fromcable trench without any damage to the cable and disposing it within a lead of 50 meteres or putting it back i nto the same trench or in a new cable trenchasperdrawingwithinaleadof50meteresall complete with labour and mater ials as per the direction of the Engineer-in-Charge. |
211 | REMOVAL OF RCC SLAB UPTO 150 MM THICK |
212 | Removal ofrcc slab upto 150 mmthickand ofany size placed above the cable trench, handlingcarefully without any damage of t he slab and cable beneath it and keeping itbackinpositionafterlaying/removingthecableand sealingthesamebet weenrcccoverswithcement& sand. job complete in all respect with labours and materials and as per directionof engineer -in-charge. |
213 | CABLE DISMANTLING / PULL OUT |
214 | Dismantling/pullingouttheLT/HT,PVC/XLPE,power/ control/telephone/computer,armoured/unarmoured cablesofva riousvoltagegrades/types/sizes/makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rollingit into empty cable drums, returning the filled up cable drums to the store/another site including transportation o f empty cable drums from stores tositeandfilledupcabledrumsfromsite to stores/anothersite, etc .includingcuttingofcablesat joints/ termination, dismantling of clamps etc. all complete with labour and materialsas per directions of the Engineer-in-Charge. |
215 | Overall diameter upto 35 MM |
216 | Overall diameter > 35 MM but upto 55 MM |
217 | Overall diameter >55 MM but upto 75 MM |
218 | Overall diameter > 75 MM |
219 | REMOVING & REPLACING OF CHEQUERED PLATE |
220 | Removing of MS chequered plate for cable ducts/ trenches and placing them after the job as per directions of EIC. |
221 | DISMANTLING OF BATTERY SET |
222 | Dismantlingofbatterysetincludingremovingelectrolyte from cell and transporting to the store (per cell). |
223 | DISMANTLING OF ELECTRICAL WIRING |
224 | Electricalwiring(comprisingofsingleortwincorePVC wires upto 6 Sq mm and single earth wire upto 6 SWG) along with itsconnected accessories like junction boxes, surface conduits, battons, switch boards etc. |
225 | DISMANTLING OF LIGHT FITTINGS |
226 | Dismantling of following light fitting items without damage and returning them to our stores or any other place or site within thepremises as decided by the Engineer-in- Charge. all complete with labour andmaterials including dismantling ofsuppo rtsofany type, downrods, chokes, condensers and any other accessories as per the directions of the Engineer-in-C harge. |
227 | Tubelightfittingsofalltypes/makesincluding single/doubletubelightfittingsandbulkheadfittings i nstalled at different places in free zones. |
228 | FLP/Non-FLPfloodlightfittingssuitableformax.upto 1000WlampsandHalogenlampsinstalledatdifferent placeslikeFLDMs/Towersetc.includingcontrolgears havingbeenfittedatheightsmorethan 20metresfrom ground floor. |
229 | DISMANTLING OF CEILING FANS AND EXHAUST FANS |
230 | Dismantling of all types & sizes of ceiling fans with down rod and regulator and exhaust fans of sweep 350/450 mm alongwith shutte r, frame etc. without damage and returningthemtoourstoresoranyotherplaceorsite within the premisesas decided by the Engineer-in- Charge. all complete with labour andmaterials including dismantling ofsupports o fany type, down rods, condensers and any other accessories as per the directions of the Engineer-in-Charge. |
231 | DISMANTLING OF SWITCH FUSE UNIT/FUSE UNIT/DB ETC. |
232 | Dismantlingofswitchfuseunit/fusegearunit/DB/any other control without using heavy lifting equipments without anydamageandreturningittoourStoresall complete with labour and materials as per the direction of the Engineer-in-C harge. |
233 | Upto and including 10 Kg |
234 | DEMOLITION OF PLAIN CEMENT CONCRETE |
235 | Demolishingconcreteanddisposal ofmaterialwithin50 metres lead: |
236 | 1:3:6 or richer mix |
237 | DEMOLITION OF REINFORCED CEMENT CONCRETE |
238 | Demolishing R.C.C. work including stacking of steel bars anddisposalofunserviceablematerialwithin50metres lead: |
239 | DEMOLITION OF BRICK WORK |
240 | Demolishing brick workincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead: |
241 | In cement mortar |
242 | ROAD DISMANTLING |
243 | Dismantling including stacking of serviceable material and disposal of unserviceable material within 50 metres lead: |
244 | Bituminous road |
245 | CHIPPING OF RCC |
246 | Chipping of RCC work (taking all necessary safety precautions),exposingthereinforcementbars,cleaning, lappin g or welding with new reinforcement as per drawings, cleaning, wire brushing and washing the exposed sur faces including disposal of unserviceable materialasdirectedforallliftswithintheowner"sarea, necessary sca ffolding etc. for all elevations with all labour andmaterialscompleteasperdrawings,specifications and directions of the Engineer-in-Charge. |
247 | DISMANTLING RCC WORK WITH CONCRETE BREAKERS IN HAZARDOUS AREAS |
248 | Dismantling RCC work with contractor"s own Pneumatic/Electricconcrete breakers including arrangement for tapping compressed air fromowner"ssources (whichwillbeallowedsubjecttoavailabilityofair) in hazardous areas like pumphouses,inside unit areas which are fire p rone due to presence of petroleum vapours etc. and elaborate precutions are to be taken for dismantling as per fire permit, clearanc e etc. and work is done extremely cautiously .The work item includes cost of all necessary accessories including breakers ,needleset c. (taking all safety precautions) including cutting reinforcementbars, embedded structural steel members, disposal of the same as d irected for all lifts within the owner"s area with necessary scaffolding, propping and under pinningetc. for all elevations with alllabour and materialscomplete as perdrawings,specifications and directions of the Engineer-in-Charge |
249 | DISMANTLINGOFPOWERDISTRIBUTION EQUIPMENTS |
250 | Dismantlingoffollowingpowerdistributionequipments without any damage to it and returning it to our stores or reinstallatio nofsameataplacewithinaleadof3KM (reinstallationchargesnotincludes)allcompletewith labour and mater ials as per the direction of the EIC. |
251 | Small equipment requiring tractor trailer but not requiring crane / hydra etc. (beyond 100 kg.) |
252 | Equipmentweighingabove500kgandrequiringhydra and tractor trolley etc. |
253 | Equipment weighing more than 3 MT and requiring crane and tractor trolley etc. |
254 | CABLE DISMANTLING / PULL OUT AND RELAYING |
255 | "Dismantling/pullingouttheLT/HT,PVC/XLPE,power/ control/telephone/computer,armoured/unarmoured cablesofv ariousvoltagegrades/types/sizes/makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays and relaying as per drawing and direction of Engineer-in charge, all complete with labour and materia ls.Jobincludesdeclamping,reroutingand relaying of cable for reglanding etc." |
256 | Overall diameter upto 35 MM |
257 | Overall diameter > 35 MM but upto 55 MM |
258 | Overall diameter > 75 MM |
259 | "COPPER WIRING IN EXISTING CONDUIT / CASING CAPING Supplying and drawing following size of PVC insulated, copper conductor, single c ore cable in the existing surface / recessed, PVC/ steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used. " |
260 | 1 X 1.5 SQMM |
261 | 3 X 1.5 SQMM |
262 | 3 X 2.5 SQMM |
263 | "SUPPLY & FIXING OF RECESSED PVC CONDUIT Supply and fixing of following size of PVC conduit along with the accessories in surface including cutting the wall and making good the same incase of recessed, conduit as required:" |
264 | 20 mm |
265 | "SUPPLY & FIXING OF PVC CASING / CAPING Providing and fixing following size of PVC casing and caping on surface as required." |
266 | 20 mm x 10 mm |
267 | MV DANGER NOTICE PLATE |
268 | Providing and fixing M. V. danger notice plate of 200 mm x150mmmadeofmildsteel,atleast2mmthickand vitreous e namelled white on both sides and with inscription in signal red colour on front side as required. |
269 | HT DANGER NOTICE PLATE |
270 | "Providing and fixing H.T. danger notice plate of 250 mm x 200mmmadeofmildsteel,atleast2mmthickand vitreous enamelled white on both sides and with inscriptio n in signal red colour on front side as required." |
271 | HT CABLE DISCONNECTION |
272 | Disconnection of HT cables of following sizes at one end and reconnecting it at same place or another place after dressingandcle aningtheterminalsallcompletewith labourand materialsasperthedirectionofthethe Engineer-in-Charge |
273 | Overall diameter > 35 MM but upto 55 MM |
274 | Overall diameter >55 MM but upto 75 MM |
275 | Overall diameter > 75 MM |
276 | LT CABLE DISCONNECTION |
277 | Disconnection of LT cables of following sizes at one end and reconnecting it at same place or another place after dressingandcle aningtheterminalsallcompletewith labourand materialsasperthedirectionofthethe Engineer-in-Charge. |
278 | Overall diameter upto 35 MM |
279 | Overall diameter > 35 MM but upto 55 MM |
280 | Overall diameter >55 MM but upto 75 MM |
281 | Overall diameter > 75 MM |
282 | SUPPLY & FIXING CHEQUERED PLATES |
283 | Supply, installation and fixing ofms chequered plates of 5mmthickness.jobincludescuttingtosize,supplyof hinges /hooks for lifting, tag welding with support whereverrequired,paintingincludingsupplyofpaint, supply of al l material and labor complete in all respect |
284 | RCC PIPE WORK AND FINISHING |
285 | Supply and laying of rcc pipewith collers jointed with stiff mixtureofcementmortarintheproportionof1:2(1 cement:2finesand)forroadcrossing Pipesaretobe laidafterrammingandconsolidatingthegroundwith bricks,st onechipsetc.toavoidany settlement afterwards. Job includes supply of all labor and all materia lsrequiredandexecutedasperdirectionofsite engineer. |
286 | 100 mm dia. R.C.C. pipe |
287 | SUPPLY AND SPREADING OF SAND |
288 | Supply and spreading of approved fine river sand in cable trench as per the direction of Engineer-in-charge. |
289 | SUPPLY AND LAYING OF BRICKS |
290 | Supply and laying of approved 2nd class bricks of thickness 75 mm in cable trench for cable protection as per the direction of Site- in-chrg |
291 | TEMPORARY LAYING AND DISMANTLING OF CABLES |
292 | Temporarylayinganddismantlingoffollowingcables (armoured/unarmoured,power/control/ telec ommunication / computer) ofdifferent voltage grades/sizes/types for temoprary connections during shutdown etc. , including transportation of cable from stores/anothersiteandreturningthesameafter dismantling to store, all complete with labour and materials as per directions of the Engineer-in-Charge. |
293 | Overall diameter upto 35 MM |
294 | LT PANEL CLEANING |
295 | CleaningofcompletePCC/MCCpanels. Itincludes opening of side top covers, removal of dust by vacuum cleaners/blowers etc.,checking and tightening of screws, nuts, bolts, washers & connections,application of petroleum jelly and boxing up of the panels. All complete with labour and materials as per directions of the Engineer-in-Charge. |
296 | EARTH RESISTANCE MEASUREMENT |
297 | "Measurement of earthing resistance including transportation of earthing electrodes, cables etc. fromstores to site, drawi ng the same into the ground at differentpointsformeasuringtheearthresistance. The job includes the supply ofconnecti ng leads,clamps etc. Allcompletewithlabourandmaterialsasperdrawings, specifications and directions of the Engineer -in-Charge. NOTE Measuring instruments to be supplied bythe Owner." |
298 | ATTENDING COMPLAINTS |
299 | FLP/increased safety and weather proof upto 250W lamps including replacement of lamps,lampholders,connectors,glass & other accessori es etc.including external and internal cleaning of glass and complete fittings as well as other related job involved. All complete w ith labour and materials as perdirections of Engineer-in- Charge. Attending and rectification of complaint of the following NOTE: Al l materials & accessories of fittings required for attending the complaint shall be supplied by the owner free ofcost. |
300 | TRANSPORTATION OF TRANSFORMER OIL |
301 | Transportation of transformer oil anywhere within refinery premisesindrumsof200litresormorefromElectrical Workshop /Store to site, pouring transformer oil in transformertankandreturningempty/filleddrumsfrom siteasgivenbelowtoElectricalWorkshop/Storesetc. including supply of tractor & trailor with six labours, driver andfueletc. requiredforloading,unloading& transportationofempty/filledtransformeroildrums. All completewithlabou randmaterialsasperdirectionsof the Engineer-in-Charge. |
302 | CLEANING OF CABLE TRENCHES |
303 | Cleaningofcabletrenchesofdepthupto3meterand width 1.5 meter of cable galleries, sub stations and other locations etc. ThejobincludesliftingofRCC slabs/Chequerredplates,removingofpaperwastejute, mud, or any o ther unwanted materials lying in trenches & dumping these waste materials in the nearest dust bin or asdirectedbytheEngineer -in-Charge.,keepingback RCCslabs/chequerredplatesinpositions. Allcomplete with men and materials as per direction ofthe Engineer-in Charge. |
304 | PUTTY APPLICATION |
305 | "ApplicationofPVCputty/M-sealputtyonlighting fixtures/Jn. Boxes/glands/switch boards etc. to avoidenteringwater/insects/anyothertypeofthingsasper direction of the Engineer-in-Charge. NOTE: Putty will be supplied by owner free of cost." |
306 | HT PANEL CLEANING |
307 | Cleaningof HT Buspanel(Eachbreaker panel). It includes opening of top cover, removal of dust by vaccum cleaning/blow er etc. Checking & tightening of connections,cleaningofinsulator,applicationof petroleum jel ly and boxing up of the Bus bars/panels.All cleaning materials such as cotton waste, Markin cloth etc. shall be supplied by the co ntractor. All complete with men, materials andequipmentsliketools&tacklesasper direction and satisfaction of the Eng ineer-in-Charge. |
308 | TRANSFORMER CLEANING |
309 | Cleaningoftransformerincludessurfacecleaningi.e. cleaning of accumulated sticky oil and other dust, oil fins. Jobinclu desopeningofLTduct&HTterminalbox, cleaningofductandterminalbox,tighteningofnuts& bolts wherever isrequired.Job to be completed with all men,materialsandequipmentsliketools& tacklesas perdirectionandsatisfa ctionoftheEngineer-in-Charge. All cleaning materials such as markin cloth, cotton waste etc. shall be supplied by the Contract or. |
310 | HT / LT MOTOR CLEANING |
311 | CleaningofHT/LTmotors&itspushbuttonincludes cleaning of accumulated oil/spilage oil & other particles on thesurfac eofmotor&connectedcable&surrounding areaofthemotor. Allcleaningmaterialsuchascotton waste, markin cloth etc. shallbe supplied by the contractor.Job to be completed with all man & material asperdirection&e ntiresatisfactionoftheEngineer-in- Charge. |
312 | HT Motors |
313 | LT motors less than 45 KW |
314 | LT motors 45 KW & above |
315 | FILTRATION OF TRANSFORMER OIL |
316 | "Filtrationoftransformeroilby streamlinefiltermachine providedbythecontractorforimprovingtheinsulation s trength of oil to the required strength as per pacification given below (excluding the supply of oil. a) Filtration of transformer oil till desired bdv is attained as per is. b) Topping up of oil. c)Releasingalltheairfromairreleaseplug&bucholz relay. d) To and fro transportation of filter machine and equipments." |
317 | REPLACEMENT OF OLD TRANSFORMER OIL |
318 | "Replacement of the old oil from the transformer as per the specifications given below a) Old oil heating by hot oil circulator for 4 hrs. b) Draining out entire quantity of oil. c) Blanking of all opening for vaccum pulling. d)Applyingvacuumpullingfor4hrsminimum600hg mercury pressure. e) Filtration of new transformer oil for filling. f) Filling the oil under vacuum & filtration of oil till desired bdv is attained as per is. g)Releasingalltheairfromairreleaseplug&bucholz relay h) Topping up of oil. i) To and fro transportation of filter machine and equipments. j) Transportation of old and new oil." |
319 | PROVIDING & LAYING CEMENT PLASTER |
320 | "Providing and laying smooth Cement Plaster with cement mortarofproportionandthicknessspecifiedbelow,on RCC/PCC/Masonr yworks etc. in walls, ceilings etc., includingpreparationofbase,rakingofpoints,making dripmoulds,scaff oldinguptoanyheight,roundingthe corners, curing etc. with all labour and materials complete,asperdrawi ngs,specificationsanddirections of the engineer-in-charge" |
321 | 12 mm thick plaster with Cement Mortar 1:6 (1 Cement: 6 Fine sand |
322 | PAINTING OF ELECTRICAL EQUIPMENTS |
323 | Cleaningofsurface,rustremovingofforeignmatter, rubbingdownthoroughlywithemerypaper,wirebrush, washing wi thdegreasing solvent(white spirit)to remove greaseetc.andpreparationofsurfaceforapplicationof enamelpaintbyspraypaintingonbusducts, transformers/motorsoranyothermetallicsurfacewith one coat of rea dy mixed primer and two coats of approved quality/APCOLITE ASIAN synthetic enamel paint including supply of pain t suitable for a temperature of100DegreeCelsius. Allcompletewithlabourand materials as per directions of the Enginee r-in-Charge. |
324 | Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application ofpaint by spray painting on electrical eq uipment/ structures/ polesor any other metallic surface with two coats ofapproved brand and manufacturer Aluminium paintinclud ing supply of paint suitable for a temperature of 100 Degree Celsius.All complete with labour and materials as per directions of t he Engineer-in-Charge. |
325 | "Lettering with black Japan paint of approved brand and manufacture Note : Unit of measurement isconsidered EACH which is equal to percm height per letter." |
326 | Calliberation of Measuring equipments from NABL accrediated lab & submission of reports. Note: UoM is EA which is equal to calliberation of each equipment. |
327 | INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of 2 mm thickness, approved quality insulating Elastomermat confor ming to IS 15652:2006 , as per specifications(Class A) |
328 | Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 7.6 Kg each) including its tail cable of size of 1c x 6 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill mat erial ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per spe cifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings. |
329 | Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including it s tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, specialback-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling e tc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall b e carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings. |
330 | "Supply and installation of medium quality, Class-B as per IS:1239 (Part-I) standard GI pipes of following sizes to be laid in trenc hes,ready tobeburiedinconcreteincludingcutting,threading,bendingandsimilarworks,supply andinstallation of supports,clamps,smallironstructures,spacers,installationofseals,plug,bushingetc.Allcompletewithlabo urand materials as per drawings, specifications and directions of Engineer-in-Charge." |
331 | 1” GI pipe (25 mm nominal bore dia) |
332 | SUPPLY OF STRUCTURALS (IN CONTRACTOR"S SCOPE) |
333 | "Thescopeincludessupply ofstructuralslikeangle,channels,beamsetc.oftestedquality for fabrication/ erectionof structuralwork wherever required. (Material Test certificate to be produced alongwith the material)." |
334 | "TRANSPORTATION OF unserviceableInstrument Scrap like DCS & PLCpanel , Control Panel , miscellenousinstruments.and scrap assembled fromsupport and mounting accessories ." |
335 | "Handling, Shifting of unserviceableinstrument scrapfrom any site toscrap yard /instrument store/main store. It includes collecting scrap from control room , plant areasite toloadingplaceandfromunloa ding placeto scrapyardsite/ instrumentstore/main store. Dismantlingofanypanelinternal,instruments,includinga rrangementofvehicle(if required) will be in contractor’s scope." |
336 | Instrument Panel (upto 400 KG) |
337 | Instruments and miscellenous scrap. |
338 | "INSTALLATION / FIXING OF ONLINE GAS DETECTOR ( HC / TOXIC etc) The job includes the following: Shifting of new instrument with its accessories from store to work site and if required reshifting of the old instrument with its ac cessories back to the instrument store yard. Installation/Fixing of Gas Detector with its accessories. Glanding, ferruling and termination of the signal cable/ control cable of the instruments wherever required, including aluminium tag ging, supply of ferrule, lugs and aluminium tag is in contractor’s scope of supply but cable gland shall be supplied free of cost byowner. Fabrication, installation and grouting of small supports for instrument (if complete yoke support is required, then it will be an extra item as per SOR ref. No. 17.1.1 / 17.2.2) and cable wherever necessary. Cutting and modification of existing support if required. All above jobs are inclusive of supply of all sorts of erection materials, grouting material (cement, concrete,sandetc.)andc onsumablesexceptingthesupply ofPipes,PipeFittings,Structural Material and Instruments." |
339 | REMOVAL OFPANEL WIRING |
340 | "Removal of all types of wire connections. Removal of wires from the cabinet. Removal ofall accessorieslikewireducts,terminal block,channels,fuseholders,barriers,trip amplifiers, relays, relay base etc. as per requirement." |
341 | TERMINATION OF WIRE |
342 | "Dressing, Ferruling, and Termination of wire Supply of dressing & clamping material, ferrule and lugs is in contractor’s scope of s upply. Supplied lugs shall be Dowel make only. Checking of termination. *Necessaryskilled&unskilledmanpower,supervision,tools&tackles,consumableswillbein contractor’s scope. The job shall be carried out as per specification and direction of Engineer-in-charge." |
343 | Size: up to 2.5 Sq. mm |
344 | Size: Above 2.5 Sq. mm and up to 4 Sq. mm. |
345 | "CABLEGLANDING&TERMINATIONWITHSINGLECOMPRESSIONBRASSGLANDS(SUPPLYOFGLANDINIOCL SCOPE)" |
346 | Glanding&terminationofsignal/control/triad/T/Candpowercableswithsinglecompressiontypebrasscableglands,restoration of insulation, clamping of the cable including supply of clamps. Tagging with aluminium tags, earthing of armour, conne ctiontotheequipmentterminalsetc.excludingsupplyofsinglecompressionbrasscableglands.Allcompletewith l abour and materials as per drawings, specifications and directions of Engineer-in-Charge. |
347 | Cable gland size 1/2" & 3/4" |
348 | Cable gland size 1" |
349 | Cable gland size 1 1/2" |
350 | "Major maint. of High Mast: Major maint. work will include but not limited to thefollowing: 1. Lowering of the lantern carriage. 2. Checking of the power connections of the individual light fittings, JBs (Both power JB installed at bottom & at top) & rectificat ion of the same. 3. Replacement of owner supplied bulbs, ballast, ignitor, capacitor, entire fittings, JBs, etc. 4. After maint. raising the lantern carriage to irs original position. 5. Maintenance of feeder of the High Mast if required. 6. Checking of the functionallity of the High Mast. 7. Supply of consumables viz. grease, connecting wires, pvc tapes etc. All the works to be carried out as per the direction of EiC or Site Engineer. Note: UoM is EA which is to equivalent to per High Mast." |
351 | Hydra of capacity more than 3 MT but up to 10 MT |
352 | Crane of capacity more than 25 MT but upto 50 MT |
353 | Tractor & Trolley for mobilisation of equipments |
354 | Variable Part: ARC PHDPL & PHDPL Aug |
355 | "LAYINGOFLTPOWER/CONTROL/ SIGNAL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES IN TRENCHES: Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables of following sizes in pre-excavated cable trenchor existing trench / RCC or Hume or Stoneware or Metal pipe / masonry duct, fixing of number tags ( if required), testing plus tran sportation from stores to site, unpacking, straightening, dressing of cable and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost." |
356 | Overall diameter upto 35 MM |
357 | Overall diameter > 35 MM but upto 55 MM |
358 | Overall diameter >55 MM but upto 75 MM |
359 | "HT CABLE LAYING IN TRENCHES: Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed/ XLPE HT power cables of voltage grade exceeding 1.1 KV but not exceeding 33 KV of following sizes in pre- excavated cable trench or existing trench / RCC orHume or Stoneware or Metal pipe / masonry duct, fixing of number tags ( if required), testing plus transportation from stores to si te, unpacking, straightening, dressing of cable and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost." |
360 | Overall diameter > 75 MM |
361 | "TEMPORARY CABLE LAYING ON SURFACE: Temporary laying and fixing of LT power/control/telephone cables onsurface as required including carriage, handling, testing, cutt ing, sealing, fixing with clamps / cleats etc., transporation of cable from stores to site and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawing, specification and direction of the Engineer -in-charge. NOTE: 1) Cables will be supplied by the Owner free of cost." |
362 | Overall diameter upto 35 MM |
363 | "EXCAVATION OF EARTH FOR CABLE / PIPE LAYING FOR ELECTRICAL WORK: Excavation of earth for cable trenches / laying of G.I. pipes for cable work in all types of soils including saturated soil upto a m ax. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers n ot exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all comp lete with labour and materials as per standards, drawings, specifications and directions of Engineer-in- charge." |
364 | "SFI OF GI CABLE TRAY (INCL. COST OF TRAY) Supply ,fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and / or fix to steel / RCC columns, beams, or any other structure members with MS suspenders, angles, channels etc. complete as per the direction of Engineer-in-Charge" |
365 | 100 mm x 25 mm x 2 mm |
366 | "LT CABLE END TERMINATION FOR ARMOURED PVC INSULATED ALUMINIUM CABLE WITH DOUBLE COMPRESSION FLAME PROOF TYPE BRASS GLANDING (INCLUDING COST OF GLANDS & LUGS) Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell"s or approved equivalent) , wherever specified, providing aluminiumlugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagg ing with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge" |
367 | 3 x 10 sqmm |
368 | 3 x 25 sqmm |
369 | 3 x 70 sqmm |
370 | 3 x 185 sqmm |
371 | 3 x 400 sqmm |
372 | 4 X 4 Sqmm |
373 | 4 x 16 sqmm |
374 | "LTSTRAIGHTTHROUGH CABLE JOINTFOR ARMOUREDPVCINSULATEDCABLE(INCLUDING COST OF JOINT KIT OF HEAT SHRINKABLE TYPE) Making straight through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, strippi ng of cable insulation, including supply of heat shrinkable TUBULAR straight through cable jointing kit of Raychem / CCI / approved equivalent make with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer in- charge." |
375 | 3 / 3.5 / 4 x 10 sqmm |
376 | 3 / 3.5 / 4 x 16 sqmm |
377 | 3 / 3.5 / 4 x 25 sqmm |
378 | 3 / 3.5 / 4 x 70 sqmm |
379 | 3 / 3.5 / 4 x 185 sqmm |
380 | 3 / 3.5 / 4 x 400 sqmm |
381 | "11KV(E)/(UE)/6.6KV(UE)HEATSHRINKABLE STRAIGHTTHROUGHPVC/XLPECABLEJOINTING (INCLUDING COST OF JOINTING KIT): Making straightthroughcablejointforpower (PVC/XLPE)armouredcableandfollowingsizesand gradeincl udingcutting,strippingofcableinsulationall complete with labourincluding travel,transportation, boarding andlodging of the cable jointer and materialsexcludingcostofjointingkitasperstandard and direction of the Engineer-in-Charge." |
382 | 3 x 120 sqmm |
383 | 3 x 240 sqmm |
384 | 3 x 400 sqmm |
385 | "11 KV(E) / (UE) /6.6KV(UE) HEAT SHRINKABLE INDOORPVC/XLPECABLEENDTERMINATION (INCLUDING COST OF END TER MINATION KIT) Providing end termination of power cable including cutting, stripping, providing & fixing of lugs, cable i nsulation,providing&glandingsingle/double compression heavy duty brass cable gland conforming to IS-12943 ,providing aluminiumlugs, crimping/soldering, as necessary, restoration of insulation/ clamping of cable, tagging with aluminium t ag,earthing of armour, connection totheequipmentterminalsetc.allcompletewithlabour including travel,transportation, boarding and lodging ofthecablejointerandmaterialsasperstandardand direction of the Engineer-in-Charge." |
386 | 3 x 185 sqmm |
387 | 3 x 240 sqmm |
388 | 3 x 400 sqmm |
389 | "EXTRA FOR PROVIDING COPPER LUGS Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the followin g sizes." |
390 | 1.5 sqmm |
391 | 2.5 sqmm |
392 | 4 sqmm |
393 | 6 sqmm |
394 | 10 sqmm |
395 | 25 sqmm |
396 | 35 sqmm |
397 | 50 sqmm |
398 | "EXTRA FOR PROVIDING ALUMINIUM LUGS: Supply ofaluminiumtubeterminalheavyduty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the following sizes." |
399 | 2.5 sqmm |
400 | 4 sqmm |
401 | 6 sqmm |
402 | 10 sqmm |
403 | 16 sqmm |
404 | 25 sqmm |
405 | 35 sqmm |
406 | 50 sqmm |
407 | 70 sqmm |
408 | 95 sqmm |
409 | 120 sqmm |
410 | 185 sqmm |
411 | 240 sqmm |
412 | 400 sqmm |
413 | "EXTRA FOR PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS: Supplyof CMRS/CCEapprovedflameproofdouble compression(brass)cableglandforfollowingoverall cable sizes as p er directions of Engineer-in-Charge." |
414 | 10.0 to 16.0 mm |
415 | 16.5 to 18.0 mm |
416 | 18.5 to 20.0 mm |
417 | 20.5 to 23.0 mm |
418 | 23.5 to 26.0 mm |
419 | 26.5 to 30.0 mm |
420 | 30.5 to 33.0 mm |
421 | 33.5 to 37.0 mm |
422 | 37.5 to 41.0 mm |
423 | 41.5 to 46.0 mm |
424 | 46.5 to 52.0 mm |
425 | 52.5 to 60.0 mm |
426 | "EARTHING WITHGI STRIP: ProvidingEarthingwithGIstripofthefollowingsizes includingsupplyandlayingofGIstripandconnecting consu mables,allcompletewithlabourandmaterialsas per direction of Engineer-in-Charge." |
427 | 50 X 6 MM GI STRIP |
428 | 25 X 5 MM GI STRIP |
429 | "BARE STRANDED COPPER FLEXIBLE EARTHING: EARTHING WITH BARE STRANDED COPPER FLEXIBLE CONDUCTOR Earthing with bare stranded tinned copper flexible conductor including providing and connecting equipments with earth busbar,supply and fixing of copper stranded wire of following sizes and making connection with equipment by means of GI bolts, nuts, washers,coppe r lugs etc. all complete with labour and materials as per direction of Engineer-in-Charge." |
430 | 16 sqmm |
431 | 70 SQ. MM |
432 | "EARTHING WITH BARE GI WIRE: Earthingwithbare GIwire,providingandconnecting equipments with earth bus bar including supply and fixing of bare GI wi re of following sizes and making connection withequipmentbymeansofGIbolts,nuts,washers, copper lugs etc. all complet e with labour and materials as per direction of Engineer-in-Charge." |
433 | 14 SWG |
434 | EARTHING WITH GI WIRE ROPE |
435 | EarthingwithGIwirerope,providingandconnecting equipment with earth buss bar including supply and fixing of GI wire rop e of following diameter and making connection with equipment by means of GI bolts, nuts, washers, copper lugs etc. all complete withlabour and materials as per direction of Engineer-in-Charge. |
436 | 6 MM |
437 | 10 MM |
438 | 15.875 MM (5/8") |
439 | 25.40 MM (1") |
440 | 36 MM |
441 | 48 MM |
442 | "PROVIDING EARTHING ELECTRODE: ProvidingearthingelectrodeasperIS:3043standard/ drawing/specifications withfollowingsizes medium quality ,Class-B,ITC/KT/JindalmakeGIpipefabricated asperthestandarddrawinganddrivenintheearthpit filledupwithcharcoalorcokedustmixedwithsaltclay (salt 0.5%) including providing inspection chamber as per thedrawingwit hremovableRCC(1:2:4)cover,earth, excavation,backfilling,masonryworketc.allcomplete with labour and materialsas per the direction of Engineer- in-Charge. Charcoal and salt cost will be paid seperately as extra." |
443 | 65 mm dia 3 metre long |
444 | "40 mm dia 4.5 metre long (without charcoal, coke and salt)" |
445 | "SALT AND CHARCOAL FOR PIPE EARTHING: Extraforusingbelowgivensaltandcharcoalforpipe earth electrode as required." |
446 | 64 kg charcoal and 5 kg salt |
447 | 160 kg coke and 5 kg salt |
448 | ALUMINIUM BBC, 4 STRIPS, 300 MM |
449 | "Supplyingandfixingbusbarchamberwith4strips busbars of length 300 mm, made of aluminium alloy or wrought aluminium, su itable for following capacity, complete with all accessories including connections, earthing the body etc. as required." |
450 | 200 amps. |
451 | COPPER BBC, 4 STRIPS, 600 mm. |
452 | "Supplyingandfixingbusbarchamberwith4strips busbars of length 600 mm, made of copper, suitable for capacity complete w ith all accessories including connections, earthing the body etc. as required." |
453 | 100 amps. |
454 | 200 amps. |
455 | 300 amps. |
456 | "Providing and fixing 32 amps. Metal clad, TP&N switch fuse unit, 415/500 volts, without H.R.C. fuses including drilling holes on th e board, connections, earthing the body etc. as required. 1.ISI marked HRC fuses shall be used. 2.TPN of English Electric / L&T / Crompton / Havells / Standard /equivalent make shall be used as per direction of Engineer-in-Charg e." |
457 | Providing and fixing 63 amps. Metal clad, TP&N switch fuse unit, 415/500 volts, without H.R.C. fuses including drilling holes on theboard, connections, earthing the body etc. as required. 1.ISI marked HRC fuses shall be used. 2.TPN of English Electric / L&T / Cro mpton / Havells / Standard make shall be used. |
458 | "SupplyofMCB/Isolator/RCCBoffollowingratingas per direction of Engineer-in-Charge." |
459 | 25 amp modular SPMCB, ‘C’ curve |
460 | "6amps.to32amps.ratings,SPMCB,“C”curve,10KA breaking capacity" |
461 | "6amps.to32amps.ratings,SPNMCB,“C”curve,10KA breaking capacity" |
462 | "6amps.to32amps.ratings,DPMCB,“C”curve,10KA breaking capacity" |
463 | "6amps.to32amps.ratings,TPMCB,“C”curve,10KA breaking capacity" |
464 | "6amps.to32amps.ratings,TPNMCB,“C”curve,10KA breaking capacity" |
465 | "40 amps. to 63 amps. ratings , 3 Pole MCB, “C” curve,10 KA breaking capacity" |
466 | "40 amps. to 63 amps. ratings , 4 Pole MCB, “C” curve,10 KA breaking capacity" |
467 | 2 Amps, 10kA breaking capacity, "C"Curve |
468 | 40 Amps, 2 Pole Isolator |
469 | 63 Amps, 2 Pole Isolator |
470 | 40 Amps, 4 Pole Isolator |
471 | 63 Amp, 4 Pole Isolator |
472 | 100 Amp, 4 Pole Isolator |
473 | 25 Amp, 2 Pole RCCB, 30mA |
474 | 40 Amp, 2 Pole RCCB, 30mA |
475 | 40 Amp, 2 Pole RCCB, 100mA |
476 | 63 Amp, 2 Pole RCCB, 30mA |
477 | 63 Amp, 2 Pole RCCB, 100mA |
478 | 25 Amp, 4 Pole RCCB, 30mA |
479 | 40 Amp, 4 Pole RCCB, 30mA |
480 | 40 Amp, 4 Pole RCCB, 100mA |
481 | 63 Amp, 4 Pole RCCB, 30mA |
482 | 63 Amp, 4 Pole RCCB, 100mA |
483 | SUPPLY & INSTLN. OF FUSEPARTS |
484 | "Supply, fixing and connection of following KNIFE TYPE HRC fuse link AS PER IS:13703:1993 & IEC 269:1986 of M/S HAVELL/L&T /G EC Astholm/Standard /MDS make or approved equivalentin distribution boardetc.all complete with labour and mate rialsas per direction of Engineer-in-charge." |
485 | KNIFE TYPE HRC FUSE LINK |
486 | 20-32 AMP Size 000 |
487 | 50 AMP Size 000 |
488 | 63 AMP Size 000 |
489 | 80 - 100 AMP Size 000 |
490 | 125 AMP Size 00 |
491 | 125 AMP Size 1 |
492 | 160-200 AMP Size 1 |
493 | PROVIDE SHOCK HAZARD CHART |
494 | SupplyandinstallationofshockhazardchartasperIE Rules1956(Clause-44)completewithframeandglass includi ng necessary clamps, bolts, rawl plugs, etc. breachkingandmakinggoodthewallifrequired.All complete with labour and materials as per |
495 | PROVIDE CAUTION BOARD AT SUB-STATION |
496 | Supply and installation of "Caution Boards" at sub-stations asperIS2551/uptodateincludingsupplyofnecessary clamps, nut s, bolts and other hardware. All complete with labour and materials as per the direction of the Engineer- in-Charge |
497 | "PROVIDE FIRST-AID BOXES Supply and fixing of First-Aid boxes as per IE Rules, 1956 Clause 43(2), including necessary clamps, bolts, rawl plugs, etc. breachk ing and making good the walls if required. All complete with labour and materials as per the direction of Engineer-in-Charg " |
498 | FIRE BUCKETS AND STAND |
499 | "Supply of floor mounting stand for keeping 4No of fire bucket 1500mmlength,900mmheightmadeoutof40x40x6mm angleironweldedwith4hooksanddulypaintedwithone coatofredleadandtwocoatsofenamelpaintasper direction of Engineer-in-Charge." |
500 | Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity asperIS:2546madeoutof24gaugeGIsheetwithextra handl e at bottom duly painted inside and red out side with printedwithFIREMarkforstandandhookandfilledwith sand and a rranged to existing stand or hook as per direction of Engineer-in-Charge. |
501 | PROVIDE CANOPY IN PUSH BUTTON STATION |
502 | Supply and erection of 250 mm x 380 mm 340 mm deep at top and 120 mm deep at bottom canopies made out of 2 mmthicksheetfor mou ntingon PushButton Stations support to render them weachther proof including fabrication, mechanical assembly and su pply and fixing of screws,nuts,boltsetc.andpaintingwith2coatsof bituminous aluminium synthetic enamel paint over acoat of red oxide primer all complete with labour and materials as per the direction of Engineer-in-Charge |
503 | SUPPLY AND FIXING OF EQUIPMENT IN PANELS |
504 | Supplying anderection ofPushButtonStation/Control Station with MS channel grouted with PCC including excavationalignment,e rection and connection ofPush Button, connection of control cable, earthing including supply and fixing of saddles, nuts, bolts et c. and painting wth two coats of bituminous aluminium paint/synthetic enamel paint over a coat of red oxide primer all complete withlabour and materials as per drawing and the direction of Engineer-in- Charge (Push Button will be supplied by Owner free of cost) |
505 | Supply, fixingand connectionoffollowingequipmentsin panels including small mechanical works and supply of all fixing mater ials. All complete with labour and materials as per the direction of Engineer-in-Charge |
506 | Power Contactor (Upto 2NO + 2 NC)- Above 25 Amp but upto 45 Amp (AC3) for AC standard coil voltage - 110, 220, 240, 415 V, 50Hz TypeMNX45 of L&T or equivalent |
507 | SUPPLY & INSTALLATION OF LED INDICATION LAMPS |
508 | Supply and fixing of led indication lamp in the panels. leds shallbeprovidedwithleakagevoltageprotectionupto 40v. Oper ating voltage shall be 110v / 220v / 230v / ac / dc, Panel cutouts shallbe 22.5 / 25.5 / 30.5 mm. Terminals shal l be shrouded for finger proofing and safety are with captivated washers to hold two lugged (fork / pin) wiresinoneterminal. Jobincludessupplyoflaborand various undry materials required and finally testing of led"s for + following ed"s |
509 | Red / yellow / amber / green / milky white led"s |
510 | Blue led |
511 | Supplying following way,vertical, three pole and neutral, sheet steel, MCB distribution board, 415 V, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, dinbarformounting MCBs(butwithoutMCBsand incomer ) as required as per IS 8623; IS 13032; IEC 61439 3 andas per direction of Engineer-in-Ch arge. |
512 | "4 way (4+4+12), TPN, vertical type, MCB DB,double door, IP-43" |
513 | "8 way (4+4+24), TPN, vertical type, MCB DB,double door, IP-43" |
514 | "12 way (4+4+36), TPN, vertical type, MCB DB, double door, IP-43" |
515 | NUMBERING OF FITTING AND FIXTURES |
516 | Numberingofceilingfan,exhaustfanandflourescent fittings as required. |
517 | REPAINTING OF CEILING FAN |
518 | Repainting ofceiling fan in installed position withone or more coats of spray painting with synthetic enamel paint ofapprovedbrandandmanufacturetogiveaneven shade, including cleaning of surface with detergent etc. as required. |
519 | INSTALLATION OFWALL MONTED FAN |
520 | Fixingofwallmontedfancompletedwithleadinwires and other accessories all complete with labour and mat erials as per direction of the Engineer-in-Charge. (cost of Fans shall be excluded) |
521 | INSTALLATION OF EXHAUST FAN |
522 | Fixing ofexhaust fans on existing opening, complete with leadinwiresandotheraccessoriesallcompletewith labour and materialsas per direction ofthe Engineer-in- Charge. (cost of fans shall be excluded) |
523 | WITH LOUVER SHUTTER/MESH |
524 | WITHOUT LOUVER SHUTTER/MESH |
525 | FLP/IS EXHAUST FAN |
526 | "SUPPLYANDINSTALLATIONOFFLPJUNCTION BOXES" |
527 | Supply, installation, testing & commissioning of following Ex-e/ weather proofjunction boxes of FCG/Baliga make, suitable for ligh ting distribution including supply of steel structure, Elemax terminal blocks suitable for terminating upto 25 sqmm PVC A1. cables, welding, painting etc.All complete with labour and materials as per drawings, specifications and directions of Engineer-in-Charge. . |
528 | 4-way Ex-e, WP Junction box with threded cover |
529 | 4-way Ex-e, WP Junction box with spigot cover |
530 | "SUPPLY OF LAMPS Supply ofbelow given M/s Philips or equivalent make lamps for installation in lighting fittings / fixtures as per directions of EIC." |
531 | INSTALLATION OFWALL MONTED FAN |
532 | LED tubelight 18W |
533 | REWINDING OF MOTORS |
534 | "Rewinding of 1-phase/3-phase electrical motors of various voltage grades/makes/types and of following capacities as per t he original specifications & types/gauge of rewinding/winding wire, insulation of various points inside slots/overhang and overall f inal layers of insulation/tapes as per the original motor specifications, after baking to required temperature and applying insulati ng varnish (Dr-Beck & Co. make & type), providing glass/other types ofsleaves on connection wires from inside motor winding to con nection plate.The winding, varnishing, tapes and other materials required for completion of this complete job is in the scope of c ontractor excluding transportation to & from Owner’s works to Contractor"s rewinding shop. which shall be paid seperately ontrip basis.The winding wirewillbeDevi Dayal make and insulation tapes shall be ISI marked & of reputed manufacturers asperdecis ion ofEngineer-in- Charge.This also includes repair/replacement of connection platecompletely includinginsulatingsheet, nu ts, bolts, washers and other hardwares as per original specifications. Thisfurtherincludesreplacementofbearings(DE& ND E) of SKF make & greasing (IOC/HP make Servogem 2 or equivalent).This further includes satisfactory trial of motors at Owner’s premises at No load as well as at Full load.The C ontractor will guarantee the rewound motors for satisfactory performance for a period of minimum six months at owner’s premises & ifany such rewound motor fails within six months, it is to be rewound again by Contractor freeof cost. Allcomplete withlabour and materials as per directions of Engineer-in-Charge.Note: Burnt winding wire shall be kept by Contractor.Bearing Shall be supp lied by IOCL" |
535 | Motors upto & including 1.5 KW |
536 | Motors above 7.5 KW but upto including 11 KW |
537 | Motors above 75KW but upto including 90 KW |
538 | REWIINDING OF FANS |
539 | "Rewindingofceiling/pedestal/exhaust/aircirculatorfans ofalltypes/sizes/makeincluding1-phaseand3-phase type exha ust fans max. upto 2.2 KW capacity andsupply ofsuperenameledwindingwire(DeviDayalmake,ISI marked insulation materi als required).This also includes replacementofsingle/doublebearingSKFmake/bushes (as per original make) and overhauling of fan and all jobs related to complete this work in totality.This also includes removal of fans from site, installation and commi ssioning after testing of rewound fans and replacement of condenser,ifrequired. This alsoincludes transportati on fromsite after dismantling to Contractor’s workshop and back to site. Note:Contractorhastogiveguaranteeforrewindingof above items for a period ofsix months and ifwinding is burnt aga in within six months of working of fans, it has to berewoundagainfreeofcostofContractor. Theburnt winding shall bekept by Contractor." |
540 | Ceiling/pedestal fans |
541 | Exhaust/air circulators fans. |
542 | Overhauling of exhaust/air circulator fans of various types/sizesmakesanditsbearingsincludingremoval from si te, cleaning, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation fro m site to workplace and back all completewithlabourandmaterialsasperdirectionsof Engineer-in-Charge. |
543 | IncludingsupplyandfixingofbearingsofSKFmake (2Nos. bearings) |
544 | OVERHAULING OF CEILING / PEDESTAL FANS |
545 | Overhauling of ceiling/pedestal fans of various types/sizes/make and its bearings including removal from site, c leaning, greasing after degreasing, assembling and fixinginposition,testingandcommissioningincluding transportation fr om site to workplace and back.All completewithlabourandmaterialsasperdirectionsof Engineer-in-Charge. |
546 | Including supply and fixing of bearings of SKF make and bushes (as per original make) of both sides by Contractor. |
547 | TransportationofLTinductionmotorforrewindingfrom Electrical Workshop at Refinery to Contractor"s works and backtoE lectricalWorkshopatRefinery.Thisincludes arrangingsuitablevehicleforto&frotransportation, unloading&load ingthemotoratrewindingworks.All complete with labour, materials, tools and tackles as per thedirectionofEngineer-i n-Charge.NOTE:Liftingfacility to put the motor in the vehicle at our end will be provided by IOCL for the motors of capacity mor e than 15 KW |
548 | Motor upto 1.5 KW |
549 | Motor above 1.5 KW to 18.5 KW |
550 | Motor above 75 KW to 160 KW |
551 | BRICK WORK IN CABLE TRENCH |
552 | Removal of bricks from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or stacking it at t he edge of the trench and putting it back intothesametrenchorinanewcabletrenchasper drawing/specification withinaleadof50meteresafter theworkiscompletedincludingcompletingtheworkin allrespects with all la bour and materials as per the direction of the Engineer-in-Charge. |
553 | Removal and relaying |
554 | Removal and stacking only |
555 | REMOVAL OF SAND FROM CABLE TRENCH |
556 | Removal of sand fromcable trench without any damage to the cable and disposing it within a lead of 50 meteres or putting it back i nto the same trench or in a new cable trenchasperdrawingwithinaleadof50meteresall complete with labour and mater ials as per the direction of the Engineer-in-Charge. |
557 | REMOVAL OF RCC SLAB UPTO 150 MM THICK |
558 | Removal ofrcc slab upto 150 mmthickand ofany size placed above the cable trench, handlingcarefully without any damage of t he slab and cable beneath it and keeping itbackinpositionafterlaying/removingthecableand sealingthesamebet weenrcccoverswithcement& sand. job complete in all respect with labours and materials and as per directionof engineer -in-charge. |
559 | CABLE DISMANTLING / PULL OUT |
560 | Dismantling/pullingouttheLT/HT,PVC/XLPE,power/ control/telephone/computer,armoured/unarmoured cablesofva riousvoltagegrades/types/sizes/makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rollingit into empty cable drums, returning the filled up cable drums to the store/another site including transportation o f empty cable drums from stores tositeandfilledupcabledrumsfromsite to stores/anothersite, etc .includingcuttingofcablesat joints/ termination, dismantling of clamps etc. all complete with labour and materialsas per directions of the Engineer-in-Charge. |
561 | Overall diameter upto 35 MM |
562 | Overall diameter > 35 MM but upto 55 MM |
563 | Overall diameter >55 MM but upto 75 MM |
564 | Overall diameter > 75 MM |
565 | REMOVING & REPLACING OF CHEQUERED PLATE |
566 | Removing of MS chequered plate for cable ducts/ trenches and placing them after the job as per directions of EIC. |
567 | DISMANTLING OF BATTERY SET |
568 | Dismantlingofbatterysetincludingremovingelectrolyte from cell and transporting to the store (per cell). |
569 | DISMANTLING OF ELECTRICAL WIRING |
570 | Electricalwiring(comprisingofsingleortwincorePVC wires upto 6 Sq mm and single earth wire upto 6 SWG) along with itsconnected accessories like junction boxes, surface conduits, battons, switch boards etc. |
571 | DISMANTLING OF LIGHT FITTINGS |
572 | Dismantling of following light fitting items without damage and returning them to our stores or any other place or site within thepremises as decided by the Engineer-in- Charge. all complete with labour andmaterials including dismantling ofsuppo rtsofany type, downrods, chokes, condensers and any other accessories as per the directions of the Engineer-in-C harge. |
573 | Tubelightfittingsofalltypes/makesincluding single/doubletubelightfittingsandbulkheadfittings i nstalled at different places in free zones. |
574 | FLP/Non-FLPfloodlightfittingssuitableformax.upto 1000WlampsandHalogenlampsinstalledatdifferent placeslikeFLDMs/Towersetc.includingcontrolgears havingbeenfittedatheightsmorethan 20metresfrom ground floor. |
575 | DISMANTLING OF CEILING FANS AND EXHAUST FANS |
576 | Dismantling of all types & sizes of ceiling fans with down rod and regulator and exhaust fans of sweep 350/450 mm alongwith shutte r, frame etc. without damage and returningthemtoourstoresoranyotherplaceorsite within the premisesas decided by the Engineer-in- Charge. all complete with labour andmaterials including dismantling ofsupports o fany type, down rods, condensers and any other accessories as per the directions of the Engineer-in-Charge. |
577 | DISMANTLING OF SWITCH FUSE UNIT/FUSE UNIT/DB ETC. |
578 | Dismantlingofswitchfuseunit/fusegearunit/DB/any other control without using heavy lifting equipments without anydamageandreturningittoourStoresall complete with labour and materials as per the direction of the Engineer-in-C harge. |
579 | Upto and including 10 Kg |
580 | DEMOLITION OF PLAIN CEMENT CONCRETE |
581 | Demolishingconcreteanddisposal ofmaterialwithin50 metres lead: |
582 | 1:3:6 or richer mix |
583 | DEMOLITION OF REINFORCED CEMENT CONCRETE |
584 | Demolishing R.C.C. work including stacking of steel bars anddisposalofunserviceablematerialwithin50metres lead: |
585 | DEMOLITION OF BRICK WORK |
586 | Demolishing brick workincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead: |
587 | In cement mortar |
588 | ROAD DISMANTLING |
589 | Dismantling including stacking of serviceable material and disposal of unserviceable material within 50 metres lead: |
590 | Bituminous road |
591 | CHIPPING OF RCC |
592 | Chipping of RCC work (taking all necessary safety precautions),exposingthereinforcementbars,cleaning, lappin g or welding with new reinforcement as per drawings, cleaning, wire brushing and washing the exposed sur faces including disposal of unserviceable materialasdirectedforallliftswithintheowner"sarea, necessary sca ffolding etc. for all elevations with all labour andmaterialscompleteasperdrawings,specifications and directions of the Engineer-in-Charge. |
593 | DISMANTLING RCC WORK WITH CONCRETE BREAKERS IN HAZARDOUS AREAS |
594 | Dismantling RCC work with contractor"s own Pneumatic/Electricconcrete breakers including arrangement for tapping compressed air fromowner"ssources (whichwillbeallowedsubjecttoavailabilityofair) in hazardous areas like pumphouses,inside unit areas which are fire p rone due to presence of petroleum vapours etc. and elaborate precutions are to be taken for dismantling as per fire permit, clearanc e etc. and work is done extremely cautiously .The work item includes cost of all necessary accessories including breakers ,needleset c. (taking all safety precautions) including cutting reinforcementbars, embedded structural steel members, disposal of the same as d irected for all lifts within the owner"s area with necessary scaffolding, propping and under pinningetc. for all elevations with alllabour and materialscomplete as perdrawings,specifications and directions of the Engineer-in-Charge |
595 | DISMANTLINGOFPOWERDISTRIBUTION EQUIPMENTS |
596 | Dismantlingoffollowingpowerdistributionequipments without any damage to it and returning it to our stores or reinstallatio nofsameataplacewithinaleadof3KM (reinstallationchargesnotincludes)allcompletewith labour and mater ials as per the direction of the EIC. |
597 | Small equipment requiring tractor trailer but not requiring crane / hydra etc. (beyond 100 kg.) |
598 | Equipmentweighingabove500kgandrequiringhydra and tractor trolley etc. |
599 | Equipment weighing more than 3 MT and requiring crane and tractor trolley etc. |
600 | CABLE DISMANTLING / PULL OUT AND RELAYING |
601 | "Dismantling/pullingouttheLT/HT,PVC/XLPE,power/ control/telephone/computer,armoured/unarmoured cablesofv ariousvoltagegrades/types/sizes/makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays and relaying as per drawing and direction of Engineer-in charge, all complete with labour and materia ls.Jobincludesdeclamping,reroutingand relaying of cable for reglanding etc." |
602 | Overall diameter upto 35 MM |
603 | Overall diameter > 35 MM but upto 55 MM |
604 | Overall diameter > 75 MM |
605 | "COPPER WIRING IN EXISTING CONDUIT / CASING CAPING Supplying and drawing following size of PVC insulated, copper conductor, single c ore cable in the existing surface / recessed, PVC/ steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used. " |
606 | 1 X 1.5 SQMM |
607 | 3 X 1.5 SQMM |
608 | 3 X 2.5 SQMM |
609 | "SUPPLY & FIXING OF RECESSED PVC CONDUIT Supply and fixing of following size of PVC conduit along with the accessories in surface including cutting the wall and making good the same incase of recessed, conduit as required:" |
610 | 20 mm |
611 | "SUPPLY & FIXING OF PVC CASING / CAPING Providing and fixing following size of PVC casing and caping on surface as required." |
612 | 20 mm x 10 mm |
613 | MV DANGER NOTICE PLATE |
614 | Providing and fixing M. V. danger notice plate of 200 mm x150mmmadeofmildsteel,atleast2mmthickand vitreous e namelled white on both sides and with inscription in signal red colour on front side as required. |
615 | HT DANGER NOTICE PLATE |
616 | "Providing and fixing H.T. danger notice plate of 250 mm x 200mmmadeofmildsteel,atleast2mmthickand vitreous enamelled white on both sides and with inscriptio n in signal red colour on front side as required." |
617 | HT CABLE DISCONNECTION |
618 | Disconnection of HT cables of following sizes at one end and reconnecting it at same place or another place after dressingandcle aningtheterminalsallcompletewith labourand materialsasperthedirectionofthethe Engineer-in-Charge |
619 | Overall diameter > 35 MM but upto 55 MM |
620 | Overall diameter >55 MM but upto 75 MM |
621 | Overall diameter > 75 MM |
622 | LT CABLE DISCONNECTION |
623 | Disconnection of LT cables of following sizes at one end and reconnecting it at same place or another place after dressingandcle aningtheterminalsallcompletewith labourand materialsasperthedirectionofthethe Engineer-in-Charge. |
624 | Overall diameter upto 35 MM |
625 | Overall diameter > 35 MM but upto 55 MM |
626 | Overall diameter >55 MM but upto 75 MM |
627 | Overall diameter > 75 MM |
628 | SUPPLY & FIXING CHEQUERED PLATES |
629 | Supply, installation and fixing ofms chequered plates of 5mmthickness.jobincludescuttingtosize,supplyof hinges /hooks for lifting, tag welding with support whereverrequired,paintingincludingsupplyofpaint, supply of al l material and labor complete in all respect |
630 | RCC PIPE WORK AND FINISHING |
631 | Supply and laying of rcc pipewith collers jointed with stiff mixtureofcementmortarintheproportionof1:2(1 cement:2finesand)forroadcrossing Pipesaretobe laidafterrammingandconsolidatingthegroundwith bricks,st onechipsetc.toavoidany settlement afterwards. Job includes supply of all labor and all materia lsrequiredandexecutedasperdirectionofsite engineer. |
632 | 100 mm dia. R.C.C. pipe |
633 | SUPPLY AND SPREADING OF SAND |
634 | Supply and spreading of approved fine river sand in cable trench as per the direction of Engineer-in-charge. |
635 | SUPPLY AND LAYING OF BRICKS |
636 | Supply and laying of approved 2nd class bricks of thickness 75 mm in cable trench for cable protection as per the direction of Site- in-chrg |
637 | TEMPORARY LAYING AND DISMANTLING OF CABLES |
638 | Temporarylayinganddismantlingoffollowingcables (armoured/unarmoured,power/control/ telec ommunication / computer) ofdifferent voltage grades/sizes/types for temoprary connections during shutdown etc. , including transportation of cable from stores/anothersiteandreturningthesameafter dismantling to store, all complete with labour and materials as per directions of the Engineer-in-Charge. |
639 | Overall diameter upto 35 MM |
640 | LT PANEL CLEANING |
641 | CleaningofcompletePCC/MCCpanels. Itincludes opening of side top covers, removal of dust by vacuum cleaners/blowers etc.,checking and tightening of screws, nuts, bolts, washers & connections,application of petroleum jelly and boxing up of the panels. All complete with labour and materials as per directions of the Engineer-in-Charge. |
642 | EARTH RESISTANCE MEASUREMENT |
643 | "Measurement of earthing resistance including transportation of earthing electrodes, cables etc. fromstores to site, drawi ng the same into the ground at differentpointsformeasuringtheearthresistance. The job includes the supply ofconnecti ng leads,clamps etc. Allcompletewithlabourandmaterialsasperdrawings, specifications and directions of the Engineer -in-Charge. NOTE Measuring instruments to be supplied bythe Owner." |
644 | ATTENDING COMPLAINTS |
645 | FLP/increased safety and weather proof upto 250W lamps including replacement of lamps,lampholders,connectors,glass & other accessori es etc.including external and internal cleaning of glass and complete fittings as well as other related job involved. All complete w ith labour and materials as perdirections of Engineer-in- Charge. Attending and rectification of complaint of the following NOTE: Al l materials & accessories of fittings required for attending the complaint shall be supplied by the owner free ofcost. |
646 | CLEANING OF CABLE TRENCHES |
647 | Cleaningofcabletrenchesofdepthupto3meterand width 1.5 meter of cable galleries, sub stations and other locations etc. ThejobincludesliftingofRCC slabs/Chequerredplates,removingofpaperwastejute, mud, or any o ther unwanted materials lying in trenches & dumping these waste materials in the nearest dust bin or asdirectedbytheEngineer -in-Charge.,keepingback RCCslabs/chequerredplatesinpositions. Allcomplete with men and materials as per direction ofthe Engineer-in Charge. |
648 | PUTTY APPLICATION |
649 | "ApplicationofPVCputty/M-sealputtyonlighting fixtures/Jn. Boxes/glands/switch boards etc. to avoidenteringwater/insects/anyothertypeofthingsasper direction of the Engineer-in-Charge. NOTE: Putty will be supplied by owner free of cost." |
650 | HT PANEL CLEANING |
651 | Cleaningof HT Buspanel(Eachbreaker panel). It includes opening of top cover, removal of dust by vaccum cleaning/blow er etc. Checking & tightening of connections,cleaningofinsulator,applicationof petroleum jel ly and boxing up of the Bus bars/panels.All cleaning materials such as cotton waste, Markin cloth etc. shall be supplied by the co ntractor. All complete with men, materials andequipmentsliketools&tacklesasper direction and satisfaction of the Eng ineer-in-Charge. |
652 | HT / LT MOTOR CLEANING |
653 | CleaningofHT/LTmotors&itspushbuttonincludes cleaning of accumulated oil/spilage oil & other particles on thesurfac eofmotor&connectedcable&surrounding areaofthemotor. Allcleaningmaterialsuchascotton waste, markin cloth etc. shallbe supplied by the contractor.Job to be completed with all man & material asperdirection&e ntiresatisfactionoftheEngineer-in- Charge. |
654 | HT Motors |
655 | LT motors less than 45 KW |
656 | LT motors 45 KW & above |
657 | PROVIDING & LAYING CEMENT PLASTER |
658 | "Providing and laying smooth Cement Plaster with cement mortarofproportionandthicknessspecifiedbelow,on RCC/PCC/Masonr yworks etc. in walls, ceilings etc., includingpreparationofbase,rakingofpoints,making dripmoulds,scaff oldinguptoanyheight,roundingthe corners, curing etc. with all labour and materials complete,asperdrawi ngs,specificationsanddirections of the engineer-in-charge" |
659 | 12 mm thick plaster with Cement Mortar 1:6 (1 Cement: 6 Fine sand |
660 | PAINTING OF ELECTRICAL EQUIPMENTS |
661 | Cleaningofsurface,rustremovingofforeignmatter, rubbingdownthoroughlywithemerypaper,wirebrush, washing wi thdegreasing solvent(white spirit)to remove greaseetc.andpreparationofsurfaceforapplicationof enamelpaintbyspraypaintingonbusducts, transformers/motorsoranyothermetallicsurfacewith one coat of rea dy mixed primer and two coats of approved quality/APCOLITE ASIAN synthetic enamel paint including supply of pain t suitable for a temperature of100DegreeCelsius. Allcompletewithlabourand materials as per directions of the Enginee r-in-Charge. |
662 | Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application ofpaint by spray painting on electrical eq uipment/ structures/ polesor any other metallic surface with two coats ofapproved brand and manufacturer Aluminium paintinclud ing supply of paint suitable for a temperature of 100 Degree Celsius.All complete with labour and materials as per directions of t he Engineer-in-Charge. |
663 | "Lettering with black Japan paint of approved brand and manufacture Note : Unit of measurement isconsidered EACH which is equal to percm height per letter." |
664 | Calliberation of Measuring equipments from NABL accrediated lab & submission of reports. Note: UoM is EA which is equal to calliberation of each equipment. |
665 | INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of 2 mm thickness, approved quality insulating Elastomermat confor ming to IS 15652:2006 , as per specifications(Class A) |
666 | Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 7.6 Kg each) including its tail cable of size of 1c x 6 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill mat erial ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per spe cifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings. |
667 | Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including it s tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, specialback-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling e tc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall b e carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings. |
668 | "Supply and installation of medium quality, Class-B as per IS:1239 (Part-I) standard GI pipes of following sizes to be laid in trenc hes,ready tobeburiedinconcreteincludingcutting,threading,bendingandsimilarworks,supply andinstallation of supports,clamps,smallironstructures,spacers,installationofseals,plug,bushingetc.Allcompletewithlabo urand materials as per drawings, specifications and directions of Engineer-in-Charge." |
669 | 1” GI pipe (25 mm nominal bore dia) |
670 | SUPPLY OF STRUCTURALS (IN CONTRACTOR"S SCOPE) |
671 | "Thescopeincludessupply ofstructuralslikeangle,channels,beamsetc.oftestedquality for fabrication/ erectionof structuralwork wherever required. (Material Test certificate to be produced alongwith the material)." |
672 | "TRANSPORTATION OF unserviceableInstrument Scrap like DCS & PLCpanel , Control Panel , miscellenousinstruments.and scrap assembled fromsupport and mounting accessories ." |
673 | "Handling, Shifting of unserviceableinstrument scrapfrom any site toscrap yard /instrument store/main store. It includes collecting scrap from control room , plant areasite toloadingplaceandfromunloa ding placeto scrapyardsite/ instrumentstore/main store. Dismantlingofanypanelinternal,instruments,includinga rrangementofvehicle(if required) will be in contractor’s scope." |
674 | Instrument Panel (upto 400 KG) |
675 | Instruments and miscellenous scrap. |
676 | "INSTALLATION / FIXING OF ONLINE GAS DETECTOR ( HC / TOXIC etc) The job includes the following: Shifting of new instrument with its accessories from store to work site and if required reshifting of the old instrument with its ac cessories back to the instrument store yard. Installation/Fixing of Gas Detector with its accessories. Glanding, ferruling and termination of the signal cable/ control cable of the instruments wherever required, including aluminium tag ging, supply of ferrule, lugs and aluminium tag is in contractor’s scope of supply but cable gland shall be supplied free of cost byowner. Fabrication, installation and grouting of small supports for instrument (if complete yoke support is required, then it will be an extra item as per SOR ref. No. 17.1.1 / 17.2.2) and cable wherever necessary. Cutting and modification of existing support if required. All above jobs are inclusive of supply of all sorts of erection materials, grouting material (cement, concrete,sandetc.)andc onsumablesexceptingthesupply ofPipes,PipeFittings,Structural Material and Instruments." |
677 | REMOVAL OFPANEL WIRING |
678 | "Removal of all types of wire connections. Removal of wires from the cabinet. Removal ofall accessorieslikewireducts,terminal block,channels,fuseholders,barriers,trip amplifiers, relays, relay base etc. as per requirement." |
679 | TERMINATION OF WIRE |
680 | "Dressing, Ferruling, and Termination of wire Supply of dressing & clamping material, ferrule and lugs is in contractor’s scope of s upply. Supplied lugs shall be Dowel make only. Checking of termination. *Necessaryskilled&unskilledmanpower,supervision,tools&tackles,consumableswillbein contractor’s scope. The job shall be carried out as per specification and direction of Engineer-in-charge." |
681 | Size: up to 2.5 Sq. mm |
682 | Size: Above 2.5 Sq. mm and up to 4 Sq. mm. |
683 | "CABLEGLANDING&TERMINATIONWITHSINGLECOMPRESSIONBRASSGLANDS(SUPPLYOFGLANDINIOCL SCOPE)" |
684 | Glanding&terminationofsignal/control/triad/T/Candpowercableswithsinglecompressiontypebrasscableglands,restoration of insulation, clamping of the cable including supply of clamps. Tagging with aluminium tags, earthing of armour, conne ctiontotheequipmentterminalsetc.excludingsupplyofsinglecompressionbrasscableglands.Allcompletewith l abour and materials as per drawings, specifications and directions of Engineer-in-Charge. |
685 | Cable gland size 1/2" & 3/4" |
686 | Cable gland size 1" |
687 | Cable gland size 1 1/2" |
688 | "Major maint. of High Mast: Major maint. work will include but not limited to thefollowing: 1. Lowering of the lantern carriage. 2. Checking of the power connections of the individual light fittings, JBs (Both power JB installed at bottom & at top) & rectificat ion of the same. 3. Replacement of owner supplied bulbs, ballast, ignitor, capacitor, entire fittings, JBs, etc. 4. After maint. raising the lantern carriage to irs original position. 5. Maintenance of feeder of the High Mast if required. 6. Checking of the functionallity of the High Mast. 7. Supply of consumables viz. grease, connecting wires, pvc tapes etc. All the works to be carried out as per the direction of EiC or Site Engineer. Note: UoM is EA which is to equivalent to per High Mast." |
689 | Hydra of capacity more than 3 MT but up to 10 MT |
690 | Crane of capacity more than 25 MT but upto 50 MT |
691 | Tractor & Trolley for mobilisation of equipments |
692 | Fixed Part PRRPL |
693 | Fixed: Bidder shall not quote above/below in this itemProviding person as Electrician : Skilled Wireman, are required to carryout the following (but not limited to that)- 1. Carrying out all the connections & disconnection of electric circuit. 2. Finding the cable fault and identified the location of fault. 3. Making of cable joints, end termination etc. 4. Inspection of all Street lights, HMTs as per schedule. 5. Rectification of any defects of Street light & HMTs. 6. Rectification of defects of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of PPL ParadipStation. 7. Responsibility to maintain the house keeping in all electrical buildings & transformer rooms. 8. Responsibility to acknowledge all the electrical related day to day complain. 9. Checking the functionality of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of Vadinar Station. 10. Cable laying, making temporary connection, dismantling & removal of unused cables, cable dressing at the equipment end & in cable tray etc. 11. Any other maintenance related work as instructed by EIC/Site Engineer.(26 days /month) Note:This work to be done by 8skilled labour per day Total no of days for 2 skilled person for 2 years: (26*12*2*2)=1248 days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis (2 Skilled ) *Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment. |
694 | Fixed: Bidder shall not quote above/below in this item Providing of Un-Skilled labours For Cleaning of Electrical and T&I instruments at field and and HT < panels, VFD, Rooms, PAC rooms, Transformer Room, CO2 flooding system room, cable cellars, trenches, detectors, MV drives, JBs, cable trays, lights, exhaust fans, fans, switches, Computers, Electrical and T &I Battery RoomsTotal no of days for unskilled person for 2 years: (26*12*0.5*2)=312days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis **Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment. |
695 | Fixed: Bidder shall not quote above/below in this item Overtime calculation of Skilled Workers(2*Normal Wage per Hour) |
696 | Fixed part PHDPL & PHDPL Aug |
697 | Fixed: Bidder shall not quote above/below in this itemProviding person as Electrician : Skilled Wireman, are required to carryout the following (but not limited to that)- 1. Carrying out all the connections & disconnection of electric circuit. 2. Finding the cable fault and identified the location of fault. 3. Making of cable joints, end termination etc. 4. Inspection of all Street lights, HMTs as per schedule. 5. Rectification of any defects of Street light & HMTs. 6. Rectification of defects of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of PPL ParadipStation. 7. Responsibility to maintain the house keeping in all electrical buildings & transformer rooms. 8. Responsibility to acknowledge all the electrical related day to day complain. 9. Checking the functionality of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of Vadinar Station. 10. Cable laying, making temporary connection, dismantling & removal of unused cables, cable dressing at the equipment end & in cable tray etc. 11. Any other maintenance related work as instructed by EIC/Site Engineer.(26 days /month) Note:This work to be done by 8skilled labour per day Total no of days for 2 skilled person for 2 years: (26*12*2*2)=1248 days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis (2 Skilled ) *Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment. |
698 | Fixed: Bidder shall not quote above/below in this item Providing of Un-Skilled labours For Cleaning of Electrical and T&I instruments at field and and HT < panels, VFD, Rooms, PAC rooms, Transformer Room, CO2 flooding system room, cable cellars, trenches, detectors, MV drives, JBs, cable trays, lights, exhaust fans, fans, switches, Computers, Electrical and T &I Battery RoomsTotal no of days for unskilled person for 2 years: (26*12*0.5*2)=312 days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis **Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment. |
699 | Fixed: Bidder shall not quote above/below in this item Overtime calculation of Skilled Workers(2*Normal Wage per Hour) |
700 | Fixed part PHPL |
701 | Fixed: Bidder shall not quote above/below in this itemProviding person as Electrician : Skilled Wireman, are required to carryout the following (but not limited to that)- 1. Carrying out all the connections & disconnection of electric circuit. 2. Finding the cable fault and identified the location of fault. 3. Making of cable joints, end termination etc. 4. Inspection of all Street lights, HMTs as per schedule. 5. Rectification of any defects of Street light & HMTs. 6. Rectification of defects of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of PPL ParadipStation. 7. Responsibility to maintain the house keeping in all electrical buildings & transformer rooms. 8. Responsibility to acknowledge all the electrical related day to day complain. 9. Checking the functionality of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of Vadinar Station. 10. Cable laying, making temporary connection, dismantling & removal of unused cables, cable dressing at the equipment end & in cable tray etc. 11. Any other maintenance related work as instructed by EIC/Site Engineer.(26 days /month) Note:This work to be done by 4skilled labour per day Total no of days for 8 skilled person for 2 years: (26*12*4*2)=2496 days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis (4 Skilled ) *Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment. |
702 | Fixed: Bidder shall not quote above/below in this item Providing of Un-Skilled labours For Cleaning of Electrical and T&I instruments at field and and HT < panels, VFD, Rooms, PAC rooms, Transformer Room, CO2 flooding system room, cable cellars, trenches, detectors, MV drives, JBs, cable trays, lights, exhaust fans, fans, switches, Computers, Electrical and T &I Battery RoomsTotal no of days for 1 unskilled person for 2 years: (26*12*1*2)=624days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis ( 1 Un skilled) **Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment |
703 | Fixed: Bidder shall not quote above/below in this item Overtime calculation of Skilled Workers(2*Normal Wage per Hour) |
704 | Fixed part PSHPL |
705 | Fixed: Bidder shall not quote above/below in this itemProviding person as Electrician : Skilled Wireman, are required to carryout the following (but not limited to that)- 1. Carrying out all the connections & disconnection of electric circuit. 2. Finding the cable fault and identified the location of fault. 3. Making of cable joints, end termination etc. 4. Inspection of all Street lights, HMTs as per schedule. 5. Rectification of any defects of Street light & HMTs. 6. Rectification of defects of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of PPL ParadipStation. 7. Responsibility to maintain the house keeping in all electrical buildings & transformer rooms. 8. Responsibility to acknowledge all the electrical related day to day complain. 9. Checking the functionality of all electrical facilities such as celling fan, exhaust fan, lamp, tube lights, power distribution board, wiring, socket etc., installed in various building of Vadinar Station. 10. Cable laying, making temporary connection, dismantling & removal of unused cables, cable dressing at the equipment end & in cable tray etc. 11. Any other maintenance related work as instructed by EIC/Site Engineer.(26 days /month) Note:This work to be done by 4skilled labour per day Total no of days for 8 skilled person for 2 years: (26*12*4*2)=2496 days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis (4 Skilled ) *Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment. |
706 | Fixed: Bidder shall not quote above/below in this item Providing of Un-Skilled labours For Cleaning of Electrical and T&I instruments at field and and HT < panels, VFD, Rooms, PAC rooms, Transformer Room, CO2 flooding system room, cable cellars, trenches, detectors, MV drives, JBs, cable trays, lights, exhaust fans, fans, switches, Computers, Electrical and T &I Battery RoomsTotal no of days for 1 unskilled person for 2 years: (26*12*1*2)=624days *Two Pair of Uniform and one set ofsafety Shoes, socks, Helmet, Uniform, Raincoat, Hand gloves,SafetyGoggles Yearly basis ( 1 Un skilled) **Any increase in the fixed component of monthly wages due to duly notified revision of minimum wage rates, the arrears on statutory contributions shall have to be paid by the Contractor to his workers and the same shall be reimbursed by IOCL to the Contractor on production of necessary proof of payment |
707 | Fixed: Bidder shall not quote above/below in this item Overtime calculation of Skilled Workers(2*Normal Wage per Hour) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail