Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremediation And Up-Gradation And Revamping Of Water Treatment Plant At Golaghat ( Pt-A ) Under Cidf Assam Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremed, golaghat-Assam

Department Of Housing And Urban Development has published Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremediation And Up-Gradation And Revamping Of Water Treatment Plant At Golaghat ( Pt-A ) Under Cidf Assam Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremed. Submission Date for this Tender is 02-04-2022. Water Treatment Plant Tenders in golaghat Assam. Bidders can get complete Tender details and download the document.




Tender Notice

31490290
Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremediation And Up-Gradation And Revamping Of Water Treatment Plant At Golaghat ( Pt-A ) Under Cidf Assam Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremed
Open Tender
Indian
Assam
golaghat
02-04-2022

Tender Details

Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremediation And Up-Gradation And Revamping Of Water Treatment Plant At Golaghat ( Pt-A ) Under Cidf Assam Rejuvination Of Jamuna Drinking Water Supply Storage Pond Through Bioremediation And Up-Gradation And Revamping Of Water Treatment Plant At Golaghat ( Pt-A ) Under Cidf Assam

Key Value

Document Fees
INR 17600 /-
EMD
INR 1759000.0 /-
Tender Value
INR 8.79 Crore /-

BOQ Items

Name of Work: REJUVENATION OF JAMUNNA DRINKING WATER SUPPLY STORAGE POND THROUGH BIOREMEDIATION AND UP-GRADATION AND REVAMPING OF WATER TREATMENT PLANT UNDER CIDF, GOLAGHAT, ASSAM.
Sl. No. Item Description
1Earth Work
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
3Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2.26.1 All kinds of soil
4Safe Disposal of hazardous sludge excavated soil from the tank outside the town(appx. 30km.)
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
6Raising low site:Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
7Open timbering over areas including strutting, shoring etc. complete. (Measurements to be taken of the face area timbered): Depth not exceeding 1.5 m
8Depth exceeding 1.5 m but not exceeding 3 m
9Depth exceeding 3 m but not exceeding 4.5 m
10Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
11Masonry Work
12Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
13Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
15Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
16Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)
17Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)
18Concrete Work
19Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
201:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
21Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size)
22Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
23FORM WORK
24Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
25Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
26Columns, Pillars, Piers, Abutments, Posts and Struts
27Lintels, beams, plinth beams, girders, bressumers and cantilevers
28Suspended floors, roofs, landings, balconies and access platform
29REINFORCED CEMENT CONCRETE WORKS
30Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
31Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
32Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum
33Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum
34CEMENT PLASTER (IN FINE SAND)
3515 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
36CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
3712 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
3815 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
39CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
40Flooring
41Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
42Painting Work
43Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
44Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
45Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
46Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work
47EXTERIOR FINISHING Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
48EXTERIOR FINISHING Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
49Steel Work
50Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
51Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
52Door/Window Works
53Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
54Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approvedshop drawings, as specified and as directed by the Engineer- inCharge.
55Roofing
56Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m²
57Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
58Site and Jungle Clearenace
59Clearance of different types and nature of Water Hyacinth,aquatic weeds, Tranies, Dalanies, Pitanies, repeated vegetation etc.from beels/Tanks/Ponds/Swampy and marshy areas dragging manually/mechanically . Heavy and floating Tarames,Dalames,Pitames and other margmal aquatic weeds etc.up to depth of 80cm to 120cm.
60Geo-textile bags
61Supply of Geo-textile bags of type-A (size 1.03 x 0.070M) inrer dimaention made of Geo-textile non oven fabric shrrts of 400GSM manufactured from 100% virgin polypropylana (PP) fiver having thickness not less than 3.00mm with minimum properties…………
62Filling and laying of Geo Bags of size 1.03 x 0.07M excluding excavation of specified sand from flood plain or adjacent chars with boat
63Landscaping
64For Horticulture operations including 300mm earth filling, grassing, tree plantation/ shrubs and potted plants etc.
65Packaged water treatment plant(25cum/h)
66Design Fabrication ( MS plates , structural steel) and Supply of, skid mountedPackage Water Treatment Plantof25m3/hrcapacity consisting of tray aerators , static flash mixer, static solid media /modular flocculators capable of producing tapered velocity gradient (G 100sec-1 to 20 sec-1(approx) ) tube settler matrix for sedimentation , dual/multi media filter with both surface washer and back wash arrangement forfilter bed andbackwash for flocculator, chemical dosers, including silver iondisinfection unit* ( plant to work under atmospheric pressure ,with gangway/ walk way, railing , ladder complete with proper anticorrosive treatment( inside zinc metalizing over sand blasted surface, 2 coats epoxy painting over primer )for long lasting along withRaw water pump ,Clear water pump , Backwash pump , Control panel etc.
67Piping work
68Labour charge for carrying laying and fixing G.I.pipes complete with G.I. fittings specials with jointing materials and supplying the jointing materials all complete as directed excluding trenching and refilling of earth (external work). 100 mm dia.2x10.00m=20.00 m
69100 mm dia. GI pipe (heavy)
70Fittings and fixings for laying of Raw water pumping Main to aerator
7120HP raw water Centrifugalpump set odf duty4000 lpm against a head of 15m
72Installation charge of new pump set alongwith construction of foundation
73Electrical Works
74Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
75Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
76Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
772 X 4 sq. mm + 1 X 4 sq. mm earth wire
782 X 6 sq. mm + 1 X 6 sq. mm earth wire
79Supplying and fixing metal box of following sizes (normal) on surface or recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm x 100 mm x 60 mm deep
80180 mm x 100 mm x 60 mm deep
81Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
823 pin 5/6 A socket outlet
83Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
84Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
85Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
86Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
87Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
88Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
89Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
90Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
91MCCB, MCB & DB"S Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
92Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
93Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCB/MCCBs (but without MCCB/MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door
94Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
95Double pole
96Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
97Supplying and Fixing Singe Pole Blanking Plate in the existing MCB DB complete etc. as required.
98Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
99Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
100Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Metre long etc. with charcoal/ coke and salt as required.
101Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
102Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
103Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
104Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
105Providing and fixing 4mm dia.copper wire on surface or in recess for loop earthing as required.
106Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
107Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
108MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (28mm)
1093½ X 120 sq. mm (70mm)
1104X 10 sq. mm (25mm)
111Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 120 sq. mm
112Supply and laying of following size of PVC/XLPE insulated and PVC sheathed 11 KV grade aluminium conductor LT armoured UG cable laid in ground/partially in air (10% of cable length) including excavation of cable trench upto depth of 75cm. Refilling, protective brick covering, sand cushioning etc. complete handling of surplus soil, debries etc. to proper place as speciefied and directed by the deptt. 4.00 mm2 3core U.G. Cable
1136.00 mm2 3core U.G. Cable
11410.00 mm2 4core U.G. Cable
11535.00 mm² 3½ core U.G. Cable
116120.00 mm² 3½ core U.G. Cable
117Supply and laying of following size of PVC/XLPE insulated and PVC sheathed 11 KV grade aluminium conductor LT armoured UG cable laid in pucca flooring road crossing, drain crossing and partially in air through GI pipe (Tata/Nezone make) with necy. bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the Deptt. 4.00 Sq.mm 3 Core U.G. cable in 20mm dia medium duty G.I. pipe
1186.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
11910.00 Sq.mm 4Core U.G. cable in 32mm dia medium duty G.I. pipe
12035.00 mm² 3½ core U.G. Cable in 40mm dia medium quality G.!. Pipe
121120.00 sqmm 31/2 core UG cable in 80mm dia medium quality.
122Design, Manufacture, Supplying, Fixing in position,Testing & Commissioning of floor mounted Feeder Pillar including all components housed in 16 SWG cubicle type sheet steel floor mounting, outdoor type as required with dust proof, hinged and lockable doors complete with inter-connections with copper wires, taps, bonding to earth & painting in line with specification, complete with neutral, earth strips of adequate size & drawings. Incoming : 160 Amps 4P 25KA MCCB- 2Nos. 160 A, 4P, on-load Changeover switch - 1 No Busbar: 320 Amps TPN Copper Busbar (40mmX5mm) Outgoings: 63 Amps 4P 25KA MCCB-3Nos. 40 Amps 4P 25KA MCCB-3Nos. 40 Amps 4PMCB-2Nos. 32 Amps DPMCB-3os.
123Design, Manufacture, Supplying, Fixing in position,Testing & Commissioning of floor mounted Feeder Pillar including all components housed in 16 SWG cubicle type sheet steel floor mounting, outdoor type as required with dust proof, hinged and lockable doors complete with inter-connections with copper wires, taps, bonding to earth & painting in line with specification, complete with neutral, earth strips of adequate size & drawings. Incoming : 40 Amps 4P 25KA MCCB Astronomical timer switch – 1 no. Busbar: 100 Amps TPN Copper Busbar (25mmX3mm) Outgoings: 10 amps DP MCB –6 nos16 amps switch and socket – 1 no. 24" tube light with switch inside feeder pillar – 1 no.
124Supplying and fixing following rating, Triple pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
125Supplying and fixing following rating, Four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
126Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 63 A, 25KA, 4P MCCB
127Supplying, installation, testing and Commission of Superior finish extruded LED Batten white powder coated pressure die cast aluminium body with High transmitivity, non Yellowing PMMA diffuser with driver and accessories pre-wired upto terminal block assembly. LED Luminaires of make PHILIPS Cat No. BN021C LED20S PSU CDL G LED 18W or equivalent inlcuding lamps etc. complete [TL]
128Supplying of 1200 mm sweep Ceiling fan of make HAVELLS Cat/Brand Cat/PACER Ceiling Fan of colour White, Brown or Bianco complete with down rod or equivalent etc. [F]
129Supplying of 300 mm sweep exhaust fan of make HAVELLS Cat/Brand VENTIL AIR -DS complete with all accessories complete or equivalent. [EF]
130Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items.. 12mm x 2mm x 15cm long 2 strip copper Bus Bar - 1 set 6-32 Amp "L" series DP MCB - 1 No. 6 amp "L" series SP MCB as outgoing - 2 Nos.
131Supplying, installation, testing and commissioning of the following of the street light luminairies of the following specification "Die Cast Aluminum housing acting as Heat Sink for reliable performance. ü Prismatic Diffuser to ensure Road Light Distribution Operating Voltage 220 – 240V /50 Hz AC ü Luminaire Efficacy of >60 lm/W ü CRI : 75 ü Ingress Protection : IP 65ü Suitable for side entry with pole diameter of 28mm to 40mm conforms to IEC598 Section 5 part 1, conforms to IEC598 Section 4 part 1, has lifetime of 50000 Hours with constant lumen output. ü Output luminaous flux of luminaire - 5700 Lumens. (a) WIPRO make Cat No.LR02-102-XXX-57-XX90W LED.[STL]
132Supplying including installation of the Octagonal poles shall be designed to withstand themaximumwind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflectionof the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuouslytapered with single longitudinal welding. There shall not be any circumferentialwelding of the pole shaft. The welding of the pole shaft shall be done bySubmerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The baseplate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approvedby Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezonemake). Pole Type BOP or equivalent-9030 Height 9m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO, Base Plate :- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening:- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. :- (A/ 70, Bottom Dia.:- (A/ 155 , Sheet Thickness :- 3mm , Base Plate Dimensions :- (L x B x 260 x 260 x 16, Foundation Bolt Size :- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia.:- (PC 250 Bolt Length:- 750, Projected Bolt Length :-125 Anchor plate thickness :- 4 mm , Pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with ( Earth work 2.04 cubic Meters.RCC 1:1.5 : 3 proportion 0.65 cubic metres. Steel 22.43 Kg. Shuttering 4.32 square metres. = 22.43 Kg.
133Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries.Header with top cap 300 mm long pipeof thickness 3 with arrangementto fix on pole top with 3 Nos. of bolts. iArmed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezonemake) Stiffener plate from arm of the following types :Single arm bracket 1000mm long for 3m to 10 metre. Poles.
134Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.)with inbuild rod as required.
135Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail