Supplying And Installing Of Utm Machine With Necessary Renovation For Existing Qgc No-1 Building. Tender Title- 1 Ksrrb M200-15.1. Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts Complete As Per Specifications. Iii ) Dismantling Stone Masonry.Rubble Stone Masonry In Mud Mortar. Morth Specification No. 202 2 Dismantling Mangalore Tiles Roof And Stacking The Material Within A Radius Of 50 Meters. Including Cost Of Materials, Labour, Hom Complete As Per Specifications. -A.C. Sheet Roofing. 3 Ksrb 2-2 : Earthwork Excavation By Manual Means For Foundation Of Buildings, Water Supply And Sanitary Lines And Electrical Conduits Etc, Either In Pits Or In Trenches 1.5M And Above In Width, In Soil Not Exceeding 1.5 M. In Depth Including Dressing The Bottom And Sides Of Pits And Trenches, Stacking The Excavated Soil Clear From Edges Of Excavation With Lead Upto 50 M. Including Breaking Of Clods Complete As Per Specifications.Ksrb 2-2.2 : --Do-- In Hard Soil. No. Kbs 2.1 ( B ) I 2.3.5 4 Ksrb 4-1.1: Providing And Laying In Position Plain Cement Concrete Of Mix 1:2:4 With Opc @ 240Kgs, With 40Mm And Down Size Graded Granite Metal Coarse Aggregates @0.878Cum And Fine Aggregates @ 0.459Cum Machine Mixed, Concrete Laid In Layers Not Exceeding 15 Ems. Thick, Well Compacted, In Foundation, Including Cost Of All Materials, Labour, Hom Curing Complete As Per Specifications Specification No. Kbs 4.1, 4.2 5 Ksrb 4.9.2 : Providing T.M.T Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Hooking, Placing In Position, Lapping And I Or Welding Wherever Required, Tying With Binding Wire And Anchoring To The Adjoining Members Wherever Necessary Complete As Per Design ( Laps, Hooks And Wastage Shall Not Be Measured And Paid ) Cost Of Materials, Labour, Hom Complete As Per Specifications. Specification No. Kbs 4.6.3 Tmt Bars Fe 500 6 Ksrb 4.2.8: Providing And Laying In Position Reinforced Cement Concrete Of Design Mix M20 With Opc @ 320Kgs, With 20Mm And Down Size Graded Granite Metal Coarse Aggregates @0.69Cum And Fine Aggregates @ 0.46Cum, With Super Plasticisers @31Ts Confirming To Is9103-1999 Reaffirmed-2008, Machine Mixed, Concrete Laid In Layers Not Exceeding 15 Ems Thick, Vibrated For All Works In Ground Floor Level For Roof Slabs, Staircase, Lintels, And Beams Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, 7 Ksrb 6-1 : Providing And Constructing Burnt Brick Masonry For Basement And Superstructure With Approved Quality Of Non-Modular Bricks Of Standard Size Of Class Designation 3.5 Newton Per Sqm With Cement Mortar Including Cost Of Materials, Labour Charges, Scaffolding, Curing Complete As Per Specifications. Specification No. Kbs 6.2 -With Cement Mortar 1:6 8 Ksrb15-3 : Providing 15Mm Thick Cement Plaster In Single Coat With Cement Mortar To Brick Masonry Including Rounding Off Corners Wherever Required Srnooth Rendering, Providing And Removing Scaffolding, Including Cost Of Materials, Labour, Curing Complete As Per Specifications. 9 Fabricating, Supplying & Erecting M.S.Angular Truss For All Spans As Per Approved Designs And Drawing. The Entire Truss Is Anchored Suitably By Using 4 Nos. Of M.S. Anchor Bolts At Each Support, With Base Plate And Shoe Plate. The Work Includes Cutting, Straightening, Placing In Position Of M.S Angle And Welding Wherever Necessary, And Applying One Coat Of Red Oxide Primer Coat To All The Members Including Cost Of All Materials, Labour Charges, & Hire Charges Of Machineries For Cutting, Welding, Grinding & Erection Equipments, Etc , Complete As Per Specification 10 Providing And Installing Of Pre Painted Galvalume Iron Trapezoidal Profiled Sheet Of Approved Make 1060 Mm Width ( 1000 Mm Cover Width ) , 28-30 Mm Crest Height With Crest Distance Of 200 Mm C / C With 2 Ribs At The Centre For Stiffening. The Total Coated Thickness ( Tct ) Of The Sheet Will Be 0.47 Mm + / - 0.02 Mm Tolerance Zinc-Aiu Alloy Coating Az150 Gsm As Per Astm 1397 / A755-550 Mpa Steel Grade, 5-7 Microns Epoxy 11 Ksrb 15-15.1 Providing And Applying Painting In Two Coats With Plastic Emulsion Paint Of Approved Brand On Wall Surface To Give An Even Approved Shade After Thoroughly Brushing The Surface, Free From Mortar Drops And Other Foreign Matter Including Preparing The Surface Even And Sand Paper Smooth, Cost Of Materials, Labour, Complete As Per Specifications.- With Primer 12 Supplying And Fixing Regular Mccb Distribution Panel Confirming To Is 8828, On Wall / Wood Board / Flush Mountingusing Required Clamps, Bolts, Nuts, Etc., With Provision For Fixing Of Suitable Type Capacity Mccbs As An Incomer For 3 Phase Double Door With Necessary Bus Bar Completely Wired To Use On 440Volts 3Phase 4 Wire Powder Coated Painting Etc., Complete With A Provision For Fixing Of Single / Three Phase Suitable Capacity Mccb / Mcbs As Outgoings Confirming To Is8828. 13 Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898. 40 Amps Sp 14 Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898. 50-63Amps Tpn 15 Supplying And Fixing Moulded Case Circuit Breaker ( Mccb ) Over The Existing Wood / Panel Board Using Necessary Screws, Bolts, Nuts, Necessary Phase Separators, Handle And Wiring Complete. Protection Of Overload And Short Circuit With Thermal Magnetic / Micro Processor Release And Earth Fault As Per Is-13947. ( Icu = Ics ) 125 Amps 25Ka. 16 Supplying And Fixing Of Metal Socket Set Of 2Pole And Earth Plugs And Socket For Incorporating Sp And Tp Mcb ( Without Mcb ) . The Entire Plug And Socket Shall Be Mounted In A Thermoplastic / Powder Coated Metal Box & Wired Completely 30Amps. 17 Supplying Heavy Gauge Pvc Conduit Pipe …….Dia .......Mm Thick Confirming To Is 2509 With Suitable Size Bends, Junction Boxes, Adhesive Paste Etc., And Fixing Using Inverted Wood Plugs In Case Of Rcc Ceiling And Rcc Wall / Stone Structure Or Rawl Plugs In Case Of Brick Walls And Cement Plastering The Damaged Portion Using Heavy Gauge Saddles At An Interval Of 700Mm Using Nf Screw 32Mm Dia 2.5Mm Thick. 18 Supplying Pvc / Gi Flexible Conduit Pipe…Mm Dia Fixing On Surface Over Inverted Tapered Wooden Plugs Or Phill Plugsor Rawl Plugs And Clamped Using Heavy Gauge Saddles At An Interval Of 300Mm Using Nf Screws And On Either End Of The Pipe Terminated Completely 25Mm 19 Supplying And Wiring Adopting Loop System In Existing Pvc Conduit / Casing Capping Using 2X1.5Sqmm ( Phase & Neutral ) & 1X1.0 Sqmm ( Earth Wire ) Frls Multi Strand Pvc Insulated Copper Wire ( Confirming To Is-694: And Latest Amendments ) With A 6Amps Flush Type Sp Control Switch Shall Be Fixed On The Existing Plastic Sheet / Gang Box, The Other End Of The Wires Shall Be Terminated With Sufficient Loose Length In A Wood / Pvc Round Block. Complete For Each Outlet. Three Outlet In A Row, Above 6Mts Upto 10Mtr From Tapping Point To Out Let Via Switches 20 Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100V Grade, Multistrand Copper Wire With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is 694:Confirming To Latest Amendments. ( 1.5 Sqmm ) 21 Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100V Grade, Multistrand Copper Wire With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is 694:Confirming To Latest Amendments. ( 10 Sqmm ) 22 Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100V Grade, Multistrand Copper Wire With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is 694:Confirming To Latest Amendments. ( 4 Sqmm ) 23 Supplying And Fixing Superior Quality Modular Switch Mounting Polycarbonate Plate With Necessary Supporting Back Plate With Required Nos. Of Machine Screws, Bolts Nuts Etc., Complete On The Existing Metal / Pvc Box. ( 6 Module ) 24 Supplying And Fixing Superior Quality Modular Switch Mounting Polycarbonate Plate With Necessary Supporting Back Plate With Required Nos. Of Machine Screws, Bolts Nuts Etc., Complete On The Existing Metal / Pvc Box. ( 12 Module ) 25 Supplying And Fixing Surface / Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Modular Switch Plates With Due Groove Cutting In Brick / C.C Wall, Including Necessary Rawl Plugs, Machine / Nf Screws Etc., Complete. ( 6 Way ) 26 Supplying And Fixing Surface / Flush Mounting Unbreakable Pvc Modular Box Suitable For Mounting Modular Switch Plates With Due Groove Cutting In Brick / C.C Wall, Including Necessary Rawl Plugs, Machine / Nf Screws Etc., Complete. ( 12 Way ) 27 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( 6Amps Sp Switch ) 28 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( 6Amps 3 Way 5 Pin Socket ) 29 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( 6Amps Bakelite Ceiling Rose ) 30 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( 16 Amps Sp Switch ) 31 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( 16 / 6 Amps Combined Plug And Socket ) 32 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( Electronic Stepped Regulator. ) 33 Supplying And Fixing / Replacing Of 6 / 16 / 32Amps Electrical Accessories On Existing Switch Board. ( 3 Phase Industrial Sockel And Plug For Moters ) 34 Supplying And Fixing Regular Mcb Distribution Boards On Wall / Wood Board / Flush Mounting Using Required Clamps, Bolts, Nuts Etc., With Provision For Fixing Suitable Type Capacity Mcbs Single Phase / 3 Phase / Single Door With Powder Coated Painting. Made Out Of 14 Swg Ms Enclosure. 12 Way Spn Db 35 Supplying, Fixing And Wiring Residual Current Circuit Breaker ( Rccb ) 240 / 450V Up To 300Ma Sensitivity On Existing Wood / Panel Board. 63 Amps 2 Pole 36 Supplying Of ......Feet - Pvc Batten With Integrated Led Tube .....W With High Quality Diffuser With Life Of 25000 Burning Hours & 70% Lumen Maintenance With Cri > 80. Power Input: 220-240V @ 50 / 60Hz & Power Factor >0.9 Along With Ce Approved. 2 Years Warranty Against Any Manufacturing Defect Working Under Standard Electrical Condition. Led Light Fitting 1 X 4 - 20 / 22 Watt 37 Utm Machine Techinical Specifications In Annexure-1