Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building , Suppl, bangalore-Karnataka

Department Of Defence Research And Development has published Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building , Suppl. Submission Date for this Tender is 11-04-2022. Coats and Jackets Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

31461331
Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building , Suppl
Open Tender
Indian
Karnataka
bangalore
11-04-2022

Tender Details

Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building Provision Of Ip-Digital Epabx System - 2 Pri Port - 24 Digital Extention - 96 Analog Intercom Lines At Ada - Nftc Building , Supply, Installation, Programming & Commissioning Of Open Scape Businessescommunication System As Per Detailed Scope Of Work ( Sl. Nos.1 To 5 Of Annexure-1 ) , Supply Installation Of 42 U ( 19” Rack ) 600 X 600 With Cable Manager & Power Kit For Mounting Epabx Voice Patch Panel. ( Sl. No.6 Of Annexure-1 ) , Supply & Fixing Of 50 Port Voice Patch Panel For Both Epabx Side & Field Side In Rack ( Sl. No.7 Of Annexure-1 ) , Supply & Fixing Of50 Pair Back Mount Frame For Mounting Modules And Label Holder Manufactured As Per ( Sl. No.8 Of Annexure-1 ) , Supply & Fixing Of 10 Pair Mdf Box With Lock Facility, The Box Shall Be Fixed On Wall By Concealed / Open Systemas Per Site Condition. ( Sl. No.9 Of Annexure-1 ) , Supply & Fixing Of30 Pair Back Mount Frame For Mounting Modules And Label Holder Manufactured As Per ( Sl. No.10 Of Annexure-1 ) , Supply & Fixing Of Mdf Box With Lock Facility; The Box Shall Be Fixed On Wall By Concealed / Open System As Per Site Condition. ( Sl. No.11 Of Annexure-1 ) , Supply & Laying Of 0.51 Mm Petroleum Jelly Filled Ug Telecommunication Cable With Conductors Copper Conductors Annealed Pvc Core Sheathed, Color Coded Pairs Twisted, Petroleum Jelly Filled, Pvc Tapes, Overall Protection. Laying The Same In Trenches And On Tunnel, Wall & Ceiling With Terminations, Commissioning, Testing, Etc. A. 50 Pair 0.51 Mm Cable From Main Exchange To Annexure Bay Of Ground Floor. ( Sl. No.12A Of Annexure-1 ) , B. 20 Pair 0.51 Mm Cable From Main Exchange To Riser Cable. ( Sl. No.12B Of Annexure-1 ) , Earth Excavation For Cable In Trenches / Ground 0.75 Mtrs Below Ground Level Including Excavation Sand Cushioning, Brick Protection On Dises And Top, Refilling Consolidating And Necessary Civil Works Complete In All Respect. ( Sl. No.13 Of Annexure-1 ) , Supply And Laying Of 0.51 Mm Two Pair Twin Case Communication Cable Laying In Wire Management System The Same With Testing, Termination, Etc. ( Sl. No.14 Of Annexure-1 ) , Supply & Fixing Of 1” Pvc Pipe Or 1” Casing And Capping With All Connecting Accessories. ( Sl. No.15 Of Annexure-1 ) , Supply & Laying Of Pvc Insulated 10 Pair Cable For Plan 103 Systemincluding Terminating The Cables At Either Ends And Servicing. ( Sl. No.16 Of Annexure-1 ) , Supply & Fixing Of 2 Inchhdp Pipe Heavy Duty With Specials For Laying Of Main Cable From Exchange To Service Bay And Drainage Crossing Etc. ( Sl. No.17 Of Annexure-1 ) , Earth Excavation For Cable Intrenches / Rcc / Ground 0.75 Mtrs Below Ground Level Including Excavation Sand Cushioning, Brick Protection On Dises And Top, Refilling Consolidating And Necessary Civil Works Complete In All Respect. ( Sl. No.18 Of Annexure-1 ) , Supply & Fixing Of Rj-11 Roset-Boxwithprotection Unit With Box. Make : Mk India / Mds / Amp / Anchor. ( Sl. No.19 Of Annexure-1 ) , Supply, Installation & Commissioning Of Media Converter ( Fiber To Pri Convertor With Patch Cable – For Connecting Pri Line To Epabx ( Both Sides ) ) . ( Sl. No.20 Of Annexure-1 ) , Supply & Fixing Of Fiberaccessories With Splicing & Connecting Fiber Cables At Both Ends. ( Sl. No.21 Of Annexure-1 ) , Supply Ofbasic Analog Push Button Telephone Instrument. ( Sl. No.22 Of Annexure-1 ) , Supply & Termination Of Patch Cables 2M Length. ( Sl. No.23 Of Annexure-1 ) , Supply, Erection, Testing And Commissioning Of Gi Pipe Earth Station Conforming To Is 3043 Complete With 40 Mm Dia. Gi Pipe Of 2.5 Mtrs Length, Watering Funnel, Charcoal, Salt Etc. Including Excavation, Refilling And Consolidating Complete. ( Sl. No.24 Of Annexure-1 ) , Construction Of Masonry Chamber For The Earth Pit Including 2’ X 2’ Cast Iron Top Cover With Frame Embedded In The Masonry Work, Marking On The Chamber & Green Color Painting, Marking Etc, Complete With Neat Cement Finish. ( Sl. No.25 Of Annexure-1 ) , Supply And Laying Oftwo Runs Of 8 Swg Copper Conductor On Ms Frame / Ground By Using Standard Fixing Accessories. ( Sl. No.26 Of Annexure-1 )

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: PROVISIONS OF IPEPABX SYSTEM -2 PRI PORT / 24 DIGITAL EXTENSION / 96 ANALOG INTERCOM LINES AT ADA - NFTC BUILDING.
Sl. No. Item Description
1Supply, Installation, Programming & commissioning of Open Scape BusinessesCommunication System as per Detailed Scope of Work (Sl. Nos.1 to 5 of Annexure-1)
2Supply Installation of 42 U (19” rack)600 x 600 with cable manager & power kit for mounting EPABX Voice patch panel. (Sl. No.6 of Annexure-1)
3Supply & Fixing of 50 Port Voice Patch panel for both EPABX side & Field side in RACK (Sl. No.7 of Annexure-1)
4Supply & fixing of50 pair back mount frame for mounting modules and label holder manufactured as per(Sl. No.8 of Annexure-1)
5Supply & fixing of 10 pair MDF box with lock facility, the box shall be fixed on wall by concealed/ open systemas per site condition. (Sl. No.9 of Annexure-1)
6Supply & fixing of30 pair back mount frame for mounting modules and label holder manufactured as per(Sl. No.10 of Annexure-1)
7Supply & fixing of MDF box with lock facility; the box shall be fixed on wall by concealed / open system as per site condition. (Sl. No.11 of Annexure-1)
8Supply & laying of 0.51 mm petroleum Jelly filled UG telecommunication cable with conductors copper conductors annealed PVC core sheathed, color coded pairs twisted, petroleum jelly filled, PVC tapes, overall protection. Laying the same in trenches and on tunnel, wall & ceiling with terminations, commissioning, testing, etc. a. 50 pair 0.51 mm cable from main Exchange to Annexure Bay of ground floor. (Sl. No.12a of Annexure-1)
9b. 20 pair 0.51 mm cable from main Exchange to Riser Cable. (Sl. No.12b of Annexure-1)
10Earth excavation for cable in trenches/ground 0.75 mtrs below ground level including excavation sand cushioning, brick protection on dises and top, refilling consolidating and necessary civil works complete in all respect. (Sl. No.13 of Annexure-1)
11Supply and laying of 0.51 mm Two pair twin case communication cable laying in wire management system the same with testing, termination, etc. (Sl. No.14 of Annexure-1)
12Supply & fixing of 1” PVC pipe or 1” casing and capping with all connecting accessories. (Sl. No.15 of Annexure-1)
13Supply & laying of PVC insulated 10 pair cable for plan 103 systemincluding terminating the cables at either ends and servicing. (Sl. No.16 of Annexure-1)
14Supply & fixing of 2 inchHDP pipe heavy duty with specials for laying of main cable from exchange to service bay and drainage crossing etc. (Sl. No.17 of Annexure-1)
15Earth excavation for cable inTrenches / RCC /Ground 0.75 mtrs below ground level including excavation sand cushioning, brick protection on dises and top, refilling consolidating and necessary civil works complete in all respect. (Sl. No.18 of Annexure-1)
16Supply & fixing of RJ-11 Roset-boxwithprotection unit with box. Make : MK INDIA / MDS/ AMP/ANCHOR. (Sl. No.19 of Annexure-1)
17Supply, Installation & commissioning of Media converter ( Fiber to PRI convertor with patch cable – for connecting PRI line to EPABX ( both sides )). (Sl. No.20 of Annexure-1)
18Supply & Fixing of Fiberaccessories with splicing & connecting fiber cables at both ends.(Sl. No.21 of Annexure-1)
19Supply ofBasic Analog Push Button Telephone Instrument. (Sl. No.22 of Annexure-1)
20Supply & Termination of patch cables 2m length. (Sl. No.23 of Annexure-1)
21Supply, erection, testing and commissioning of GI Pipe earth station conforming to IS 3043 complete with 40 mm dia. GI pipe of 2.5 mtrs length, watering funnel, charcoal, salt etc. including excavation, refilling and consolidating complete. (Sl. No.24 of Annexure-1)
22Construction of masonry chamber for the earth pit including 2’ x 2’ cast iron top cover with frame embedded in the masonry work, marking on the chamber & green color painting, marking etc, complete with neat cement finish. (Sl. No.25 of Annexure-1)
23Supply and laying oftwo runs of 8 SWG copper conductor on MS Frame/Ground by using Standard fixing Accessories. (Sl. No.26 of Annexure-1)