Rural Development Government Departments Closing in 0 days TDR #31457187

Water Supply Scheme At.Kekat Sindgi Tq.Jalkot Dist.Latur.

Issued by Government Departments · sindgi, Maharashtra
Tender Value
84.67 Lakhs
Estimated cost
Bid Submission
22 Mar 2022
0 days left
EMD
84676
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
sindgi → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Water Supply Scheme At.Kekat Sindgi Tq.Jalkot Dist.Latur.

BOQ

Name of Work: Water Supply Scheme At.Kekat Sindgi Tq.Jalkot
Sl. No. Item Description
1Sub work No - 1 CORE BOREItem No. 1 :Takling trial bore (core bore sampling )bycallyx machine with TCT/Xbits gader undisturced srata sample for invistigation in all tips of strata soft soil ,hard rock quartzite etc the item includes all hire and running cost of callyx machine conveying all materials to site of work excluding conveance of cllyx ,machine and back sampling all over burden strata in glass jar and core sample serialy nombered at site in wooden core box samples to taken at 1 m intervel and conveying to the the place as directed.In over burdan soft soil murum
2I weathredrock with boulders
3In weathred rock /soft rock
4In hard rock other than quartzite
5Sub Work No. 2 Perculation WellItem No. 1 : Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murum with boulders in wet or dry condition for Head Works i.e. Intake well, connecting pipe, Jack well, pump house, supply well, etc for lift 0 to 1.5 m and lead of 150 M including barricading gurading, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, etc. complete excluding refilling. For Head Works on river or dam sub mergence for initial lift of 0 to 1.5 Ma) Lift 0.0 to 1.50 mtr.
6b) Lift 1.50 to 3.0 mtr.
7c) Lift 3.00 to 4.50 mtr.
8d) Lift 4.5 to 6.00 m
9e) Lift 6.00 to 7.50 m
10Item No. 2 : Excavation in general in hard material comprising of soft rockl, hard rock, manjara rock etc by blasting/ controled blasting,chseling as required in wet or dry conditionfor Head Works i.e. Intake well, connecting pipe, Jack well, pump house, supply well, etc for lift 0 to 1.5 m and lead of 150 M including barricading gurading, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, etc. complete excluding refilling. For Head Works on river or dam sub mergence for initial lift of 0 to 1.5 Me) Lift 6.00 to 7.50 m
11f)Lift 7.50 to 9.00 M.
12g) Lift 9.00 to 10.50 m.
13h) Lift 10.50 to 12.00m.
14i) Lift 12.00 to 13.50 m
15j) Lift 13.50 to 15.00 m
16k) Lift 15.00 to 16.50 m
17Item No. 3: Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite / quartzite / gneiss metal for foundation and bedding including dewatering form work, compacting and curing. Finishing etc. complete with initial lift of 1.5 m. below / above ground level.PCC for levelling course.( M - 150 )Lift 5.00 to 10.00
18Item No. 4 : Providing and laying in situ cement concrete of trap / granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajshree, etc cement is permitted. Excluding M.S. or Tor reinforcement) For RCC M-200 Beams / Braces / Lintels Ring Beam leadge level ( M -300 )Lift 5.00 to 10.00
19Item No. 5: Providing and casting in situ Cement Concrete of trap / granite / quartzite / gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, cenetring, form work compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mis design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted excluding M.S. or Tor reinforcement). For RCC M-300 grade - slabs / landings / vertical walls / waist slabs / Steps for staircase. Staining wall of Percolation well ( M - 300 )Lift0.00 m to 5.00 m(Above G.L )
20Lift0.00 m to 5.00 m(Below G.L )
21Lift5.00 m to105.00 m(Below G.L )
22Item No. 6: Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footing, foundation, slabs, beams, columns, canopies staircases. Newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, derawings and schedules; including cutting, bending, hooking the bars binding with wires or tack welding and supporting as required etc. complete. (including cost of binding wire) Tor Steel.Lift0.00 m to 5.00 m
23Lift5.00 m to 10.00 m
24Item No. 7 : Providing, and fixing 75 mm dia P.V.C. pipe weep holes at 1.5 M c/c staggered including cost of all materials and labour involved with all leads and lifts etc. complete with all leads and lifts.
25Item No. 8 : Providing and fixing in position C. I. Dapuri steps or 22 mm dia M.S. bar step with proper anchorage, etc. and providing and applying three coats of ant-corrosive paintetc complete as directed by Engineer-in-charge.
26Item No. 9: Providing and filling around the well boulder filling of selected variety and size of boulders including cost of allmaterials, labour, transportation, etc complete with all leads and lifts.
27Item No. 10: Providing stuctural steel work in single stanchions composed of RSJ, channel, etc, with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineer-in-charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted/ bolted / welded connections and one coats of anticorrosive paint and over it two coats of oil painting, etc. complete. ISMB 250 x 125
28Item No. 11: Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour fuel) etc. complete.
29Item No. 12: Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M. S. angles as verticals at 1.5 M c/c, and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc. complete. As above but with only 2 rows
30Item No. 13: Providing and fixing M.S. chequerredplate flooring of following thickness supported on M.S. angles (25x25x5 mm in size) including welding, cuttting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint etc. complete as directed by engineer in charge. 8 mm thick
31Item No. 14: Carrying out recuperation / yeild test for ascerting the discharge of constructed well / excavated profile as direrted by Engineer in charge.The test carried out by drawing down water from the well/ profile below normal / subsoil water level upto full depth rise in water level is recorded. The normal water level / subsoil water level in the well / profile as well as strainer / suction level at pump as per design of W.S. scheme shall be recorded prior. to the test including cost of all materials.overhead,labours etc. completed as directed.The test shall be carried out as per technical circular No.2597 dt. 20/11/97 and shall be carried out for 7 days.
32Item No. 15: Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete. Reffiling
33Sub Work No.3 : SWITCH ROOM ( 3.00 x 2.5 M )Item No 01 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
34Item No 02 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
35Item No 03 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. PCC (M-150)
36Item No 04Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor ReinforcementRCC Footings ( M-200)
37Item No 05 Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted )RCCCOLUMNS ( M-200)
38Item No 06 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)RCCBEAMS ( M-200)
39Item No 07 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in plinth as backing with composite masonry including bailing out water manually, striking joints, raking out joints and watering complete.B.B.Masonry for super structer
40Item No 08 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .)RCCChajjas/Pardies ( M-200)
41Item No 09 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement.RCC Slab ( M-200)
42Item No 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire)Tor Steel
43Item No 11 Providing & fixing steel window and door of various sizes as per detailed drawings fabricated from I.S. standerd sections without hot dip zinc coating without /with ventilators including fabrication , glazing with non acetinic / plain / obscured glass panels of approved type and quality of fixtures and fastening without teak wood boxing, and architraves and finishing with one coat of primer complete. with guard bars 12 mm square bar 10 cm . centre to centre. DOOR & Windows
44Item No 12 Providing and fixing in position mild steel door/ window shutters including mild steel angle frame of size 50X 50X 5 mm. for fixing mild steel sheet 24 gauge including welding fixing to frame and all necessary fixtures including electrostatic powder coating etc. complete.DOOR & Windows
45Item No 13 Providing internal cement plaster 6 mm. thick in a single coat in cement morter 1:3 without neeru finish to concrete surface in all positions inculding scffolding and curing complete.Internal cement plaster
46Item No 14 Providing internal cement plaster 12 mm. thick insingle coat in cement morter 1:3 without neeru finish toto concrete or brick surfaces,in all positions inculding scffolding and curing complete.Internal cement plaster
47Item No 15 Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete.sand faced plasterexternally
48Item No 16 Provinding and applying white-wash in Two coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete.Refn. :BDP.1A Sr. No. 1026PWD S.S.R.21-22 I.No. 36.03P.No. 167
49Item No 17 Provinding and applying washable oil-bound distemper of approved colour and shade to old and new surface in two coats including scaffolding preparing the surfaces (excluding the primer coat) etc.complete.
50Item No 18 Provinding and applying three coats of water proof cement paint of approved manufacture and approved colour to the plastered surfacesincluding scaffolding if necessary, cleaning and preparingthe surface watering for two days complete.
51Item No 19 Provinding and applying two coats of synthetic enamal paint of appoved colour to new stuctral steel work in building, including scaffolding if necessary, cleaning and preparingthe surface (excluding primer coat ) complete.
52Item No 20 Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete.
53Sub Work No. 4 Pumping Machinary Item No1:- 150mm dia Sub pump set.Providing, erecting and giving test of3 HP/ 8 Stage 150 mm dia Sub pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump sheel be suitable for various delivery head and discharge with stainless steelshaft. Motor suitable for working on 415(+/-)10% volt 3 ph 50 c/s a.c. supply ,thrust corban bearing with stand entire hy .thrust. pump set shall be direct coupling with suitable strainer .pump should havesuitable discharge out late as per manufacture design .antithrust stream lined non return valve shallbe provided with pump 3mtr submersible copper conductor cable in single /double run, two pairs erection clamp 32 mm wx10mm thickshall be provided with pump.
54Item No. 2a:- 50 mm dia G.I.pipe.providing and errecting ISI mark,heavyclass,50 mm dia G.I. pipewith both end threaded &oneend B class socket. (MJP /Civil DSR page no82&83 item no SEC I-(III)1C(vi)&SEC I-(vi)2C(vi)
55Item No. 2b :-M.S.Special.providing and errecting M.S.Special for various diameter of pipe(MJP /Civil DSR page no 72 item no 7c)
56Item No. 3a:- 50 mm dia G.I.Bend. providing and errecting ISI mark, B class, 50mm dia G.I.BendwithB class socket(MJP /Mech.DSR page no 11 item no pw 1-4)
57Item No. 3b:- 50 mm dia G.I.Teeproviding and errecting ISI mark, B class, 50mm dia G.I.TeewithB class socket(MJP /Mech.DSR page no 11 item no pw 2-4)
58Item No.4:-Earthing. providing and errecting rod type earthing (electrode of20mm dia solidG.I. Rodor G.I. Pipe of40mmdia ) 2.5 mtr burried in earth or( driven in the earth with blows of moderate force ) with necessarydoubleG.I. earth strip complete errected connected to nearest switch gear earth terminal. (PWD electrical DSR page no 159 / 9-1-4)
59Item No.5:- Flat flexible sub cableproviding and errectingflat flexible submersible cable with copper conductor 3 core , pvc insulated & pvc sheathed cable wire.size : 4 sq mm(motor to panel board). for 3hp double run(PWD electrical DSR page no 218 / 12-4-9)
60Item No.6:- Armoured cable.providing and errectingAluminium conductor, XLPE / PVC insulated Armoured cable 3.5 or 4core cable size 16 sq mm(PWD electrical DSR page no125 / 7-1-11)
61Item No7:- C.I. flanges. providing and errecting ISI mark,75/80 mm dia C.I. flanges with nut ,bolt &washer (PWD electrical DSR page no 244 / 16-6-29)
62Item No.8:- Channel frame.providing, errecting Channel frame (Mjp/ civil/DSR P.no. 38 item no.SEC-F 5)
63Item No.9:- Rain Prinventive box.providing , errecting Box type Rain Prinventive box size=1.5X1X0.35& 16SWG with lock arrangement A( panel box)=5sqmtr (PWD electrical CSR p. no. 112 / 6-1-2)
64Item No10:- plywood . providing , errectingplywood19mmthickness fixed to angle frame with necessary material( PWD electrical DSR p. no.112 / 6-1-14)
65Item No. 11:- Angle frame.providing , errecting & fabrication ofangle framefor panel support ( PWD electrical CSR p. no. 113 / 6-1-19)
66Item No. 12:- Fuse bridge.providing , errecting H C pattern porcelain fuse bridge with base and H C fuse links 415/ 500 volt, 63Amp.capacity( PWD electrical DSR p. no107 / 5-10-3) )
67Item No. 13:- Triple Pole Switch. providing , errectingtriple pole iron clad /metal cladswitch& fuse32Amp 415/500 volt. ( PWD/DSR p. no. 89 item no. 5-1-6 )
68Item No. 14:- Change overSwitch. providing , errectingChange overSwitch. clad /metal clad four pole40 Amp 415/500 volt. ( PWD/DSR p. no. 90 item no. 5-1-24 )
69Item No. 15:- Volt meter. providing & errectinganalog type moving iron Voltmeterfor ACvoltage 0 to 500 volt range,50 c/s, flash type.( PWD/DSR p. no.115 item no6-3-8 )
70Item No. 16:- Ammeter. providing & errecting analog type moving iron Ammeterfor ACcurrent o to 30 Amp, directrange, 500 volt, 50 c/s flash type.( PWD/DSR p. no. 115 item no.6-3-7 )
71Item No. 17 :- Indicating Lamp. providing & errecting LED type indicating pilot lamp with LED colours RED/ Yellow / Green] 230 / 250 Volt on provided box /panel with necessary material, wring & connectons. ( PWD/DSR p. no. 119 item no.6-5-5 )
72Item No. 18:- Capacitor.providing & errectingbank of metalisedpolypropylene condensers with standard capacities of 1 , 2 , 3 , 5 , 7 , 12 , 15 , 20 & 25 kvar unit P.F. corre-ction operation on 3 ph 50 c/s500 volt + or- 10 %externally dischaging resis-tancs earthing terminals & built up angle iron or chennel iron framework&provided with terminal cover box completed& tested.(MJP Mech. CSR page no26 /cp-1)
73Item No.19:- DOL /FASD Starter.providing & errectingDOL /FASD starterto operate squirrel cage induction motor working on 380-440 volt, 3 phase,50 c/s with no volt coil and over load Relay (range 30 Amp )with nacassary material and connected to supply, etc completed.for Up to 7.5 hp capacity(MJP Mech. CSR page no27 / LG1-1)
74Item No.20:- Sluice Valve 80 mm dia. providing & errecting in position Sluice Valve-80mm dia and class including necessary jointing accessories (flanges, nut, bolts and rubber packing) as per the specification.(MJP /Civil DSR page no132&135 item no SECXII-2a(iv)&4(iv)
75Item No. 21:- RefluxValve 80mm dia. providing & errecting in position RefluxValve 80mm dia and class including necessary jointing accessories (flanges, nut, bolts and rubber packing) as per the specification.(MJP /Civil DSR page no 131&135 item no SECXII-1a(iv)&4(iv)
76Item No. 22:- MS bareels for chain pully Providing and supplying ISI standard MSspecials of required thickness with 3 coats ofapproved make epoxy paint (Shalimar, Ciba orMahindra & Mahindra make) from inside andoutside excluding all statutory duties & taxessuch as GST levied by GOI & GOM in allrespect, inspection charges, transportation tostores / site, and stacking, etc. complete.MS barrels (pipe pieces) locally manufactured(for small quantities)(MJP /Civil DSR page no 72 item no 7f)
77Item No. 23:- Chain pully block of 1 TonProviding, erecting triple spur gear type chain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift tested to 50% over load as per IS 3832 carrying ISI mark.(MJP DSR/Mech page No. 14 Sec. 5 LF 1-1)
78Sub. Work No. 5Pure Water Rising Main 90 mm dia.PVC.6.Kg/Cm2.Pipes.Item No. 1 : Providing and supplying in standard lengths ISI Mark rigid unplasticised PVC pieps suitable for potable water with solvent cement joints including cost of solvent cement joints invluding cost of couplers, as per IS specification No. 4985/1988excluding GST levied by GOI & GOM in all respect, including transportation freight charges,transit insurance, inspection charges, loading, unloading, conveyance to stores and stacking the same in closed shed duly protected from sun rays and rains etc complete ( with third party inspection)(socketed) 90 mm dia.PVC.6.Kg/Cm2.Pipes.
79PVC Specials, bends, Tee etc
80Item No. 2 : ProvidingISI mark G.I.pipe of following class and diameter including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete as directed by Engineer- In - Incharge. 80 mm dia.Class-Medium Pipes.
81Item No. 3 : Providing and supplying ISI mark CID/F ruflex valves (non return valves) of following dia including all taxes (central and local), railway freight, inspection charges unloading from railway wagon loading into truck transporatation up to departmental stores/ site, unloading, stacking etc complete. Without bypass arrangement- PN-1.6A) 80 mm dia.for Non Return Valve
82Item No. 4 : Providing double flanged Sluice Valves conforming to IS-2906 / 14846 including worm gear arrangements as per test pressure, stainless steel spindle, caps, including all taxes, transportation, etc. complete. PN -1 A) 80 mm dia.CIDF.Sluice Valve PN-1.6
83Item No. 5 : Providing and supplying Air Valves as per IS-14845-2000 and MJP\"s standard specifications of approved make and quality of following diameters including all taxxes (Central and Local), railway freight, inspection charges, unloding from railway wagons, loading into truck, transportation upto departmental stores / site, unloading and stacking excluding GST levied by GOI & GOM in all respects etc. complete. 25 mm dia Single ball air valve
84Item No. 6 : Providingand supplying ISI standard CI flanged/ S& S specials excluding GST levied by GIO & GOM in all railway fright, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc complete as directed as directed by Engineer-in-charge. a) D/F Specials ( 80 to 300 mm dia.) CID/F Tee for Air Valve ( 100 x 80 mm )
85Item No. 7 : Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 meters and lifts as below, stacking and spreading as directed, normal dewatering, preapring the bed for foundation and excluding back filling etc. complete. Lift 0 to 1.5 m. Lift - 0.00 To 1.50 M
86Item No. 8 : Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift - 0.00 To 1.50 M
87Item No. 9 : Excavation for foundation / pipe trenches in hard murum and Boulder W.B.M road including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift - 0.00 To 1.50 M
88Item No. 10 : Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift - 0.00 To 1.50 M
89Item No. 11 : Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete.Lift - 0.00 To 1.50 M
90Item No. 12 : Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm to 20 cm layers including watering and compaction etc. Murum Bedding
91Item No. 13 : A Lowering, laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, ruber ring, giving satsifactory hydraulic testing as per IS code, etc. complete. ( With cement solvent joint / ring if joint) Working pressure 6 and 10 Kg/Sq.cm. 90 mm dia.PVC.6.Kg/Cm2.Pipes.
92Item No. 13 : B Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 90 mm dia.PVC.6.Kg/Cm2.Pipes.
93Item No. 14 : A Lowering, laying and jointing ISI mark G.I.pipe of following class and diameter including all local and central taxes, octroi, inspection Charges, transportation to stosre, etc. completeas directed by Engineer- In - Incharge. 80 mm dia.Class-Medium Pipes.
94Item No. 14 : B Hydraulic testing of G.I pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 80 mm dia.Class-Medium Pipes.
95Item No. 15 : A Lowering, laying and jointing in position following C.I. D/F reflux valves, Butterfly valves and sluice valves including cost of all labour jointing material including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves)A) 80 mm dia.for Non Return ValveA) 80 mm dia.CIDF. Sluice Valve for score
96Item No. 16 : Providing and fixing in position air valve shaft including providing and fixing GI mediam class of 6 mm thick MS pipe shaft 2.70 m long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including incasing of vertical shaft in PCC M-150 as shown in type desine together with providing and making flanged joints wherever required and fixing of air valve over the shaft in excluding cost of air valve and branched air valve tee etc complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines ( type design attached ) foundation on murum and harder strata. A) Foundation in murum and harder strata Upto 150 mm dia.
97Item No. 17 : Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavatin, B.B. masonry in C.M. 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. Note : wall thickness : 0.23 m for depth of 0.9 m and 0.35 m for balance depth exceeding 1.2 m) 60 x 45 cm size and depth of 0.90 mwith precast RCC slab Cover
98Item No. 18 : Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete.
99Item No. 19 : Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite / quartzite / gneiss metal for incasing of PVC pipe in cement concrete road including dewatering form work, compacting and curing. finishing etc. complete .Cement Concretefor Encasing of PVC pipe
100Item No. 13 :Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.)
101Subwork No. 6 :RCC E.S.R .CAP - 20000 Ltrs.Staging - 12.0 M.ITEM No. 1: Designing (aesthetically), & constructing RCCelevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters center to center including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling, disposing ofthe surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and joining of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories which accessories such as M.S. ladder, C.I. manhole frame and covers water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case form ground level to roof level, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three costs of cement paint to the structure including roof slab and giving satisfactory water tightness test as per I.S. co Notes Item No. 1 contd…1. The design of the structure be in accordance with relevant I.S. 3370- 1965 or revised.2. The design shall satisfy the stipulations as per I.S. 1893-1984 and I.S. 13920/1993 for seismic force and I.S. – 11682/1985 for RCC staging of overhead tanks.3. For design having more than 6 columns , provision of internal bracing is obligatory.4. The entire structure shall be in M –250 mix only.5. Plain round mild steel bars grade- I confirming to I.S. 432 part I or high yield strength deformed bars confirming to I.S. 1786 or I.S. 1139 shall be used, grade 0 II mild steel bars will not be allowed.ITEM No. 1:- Contd…6.Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level.7.These rates include providing M.S. ladder for E.S.R.s up to 2 lakh liters capacity and providing spiral staircase for E.S.R. above 2 lakh liters capacity.8. Stagingshall have to be designed with stresses of M.- 150 concrete but actual construction shall be done in M- 250 concrete with sections worked out with M-150 design. 9. These rates are including the cost of uplift pressure if any entire dewatering during execution.10. All conditions given in the Member Secretary’sCircular No. MJP/TS-I/350/ 1668 Dt. 2-8-97 and MJP/TS/-I/I/2127 Dt. 13-7-99 shall be strictly followed and additional cost.If any, due to these conditions is included in the rates mentioned below.11. 75 % part rate shall be payable for reinforcement concrete plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given, and till that work shall be treated as incomplete.
102ITEM No.2:- Providing and supplying ISI standard CI double flanged pipes including all taxes ( Central and local ) railway fight, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc. complete as directed by Engineer-in-charge.i) 80 mm dia (For Inlet & Overflow)
103iI) 100 mm dia (For Outlet)
104ITEM No. 3:- Providingand supplying ISI standard CI flanged/ S& S specials excluding GST levied by GIO & GOM in all railway fright, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc complete as directed as directed by Engineer-in-charge. a) D/F Specials
105ITEM No. 4:- Providing, double flanged Sluice Valves conforming to IS-14846 including worm gear arranegments as per test pressure,stainless steel spindle, caps including inspection charges ,transportation up to departmental store , unloading stacking excluding GST levied by GOI & GOMin all respect etc. complete . Sluice valves Without bypass arrangement- PN-1Sluice valves as per I.S. 780 & 2906-1984.i) 80 mm dia
106i) 100 mm dia
107Sub. No.8 Trial and Run Iteam No. 1 : Commissioning running and maintaining the scheme to quantites,rated capacity,including manning necessary personnel such as operator, valveman etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP/Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer - in - charge.Note :- Required chemicals to be supplied by Department free of cost and electricity bill will also be paid by the Department.A) For single village. ( Three Months )
108Sub work No - 1 CORE BORE ChatewadiItem No. 1 :Takling trial bore (core bore sampling )bycallyx machine with TCT/Xbits gader undisturced srata sample for invistigation in all tips of strata soft soil ,hard rock quartzite etc the item includes all hire and running cost of callyx machine conveying all materials to site of work excluding conveance of cllyx ,machine and back sampling all over burden strata in glass jar and core sample serialy nombered at site in wooden core box samples to taken at 1 m intervel and conveying to the the place as directed.In over burdan soft soil murum
109I weathredrock with boulders
110In weathred rock /soft rock
111In hard rock other than quartzite
112Sub Work No. 2 Perculation WellItem No. 1 : Excavation in general in soft material comprising of soft soil, soft murum, sand, hard murum with boulders in wet or dry condition for Head Works i.e. Intake well, connecting pipe, Jack well, pump house, supply well, etc for lift 0 to 1.5 m and lead of 150 M including barricading gurading, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, etc. complete excluding refilling. For Head Works on river or dam sub mergence for initial lift of 0 to 1.5 Ma) Lift 0.0 to 1.50 mtr.
113b) Lift 1.50 to 3.0 mtr.
114c) Lift 3.00 to 4.50 mtr.
115d) Lift 4.5 to 6.00 m
116Item No. 2 : Excavation in general in hard material comprising of soft rockl, hard rock, manjara rock etc by blasting/ controled blasting,chseling as required in wet or dry conditionfor Head Works i.e. Intake well, connecting pipe, Jack well, pump house, supply well, etc for lift 0 to 1.5 m and lead of 150 M including barricading gurading, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, etc. complete excluding refilling. For Head Works on river or dam sub mergence for initial lift of 0 to 1.5 Me) Lift 6.00 to 7.50 m
117f)Lift 7.50 to 9.00 M.
118g) Lift 9.00 to 10.50 m.
119h) Lift 10.50 to 12.00m.
120i) Lift 12.00 to 13.50 m
121j) Lift 13.50 to 15.00 m
122Item No. 3: Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite / quartzite / gneiss metal for foundation and bedding including dewatering form work, compacting and curing. Finishing etc. complete with initial lift of 1.5 m. below / above ground level.PCC for levelling course.( M - 150 )Lift 5.00 to 10.00
123Item No. 4 : Providing and laying in situ cement concrete of trap / granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajshree, etc cement is permitted. Excluding M.S. or Tor reinforcement) For RCC M-200 Beams / Braces / Lintels Ring Beam leadge level ( M -300 )Lift 5.00 to 10.00
124Item No. 5: Providing and casting in situ Cement Concrete of trap / granite / quartzite / gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, cenetring, form work compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mis design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc cement is permitted excluding M.S. or Tor reinforcement). For RCC M-300 grade - slabs / landings / vertical walls / waist slabs / Steps for staircase. Staining wall of Percolation well ( M - 300 )Lift0.00 m to 5.00 m(Above G.L )
125Lift0.00 m to 5.00 m(Below G.L )
126Lift5.00 m to10.00 m(Below G.L )
127Item No. 6: Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footing, foundation, slabs, beams, columns, canopies staircases. Newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, derawings and schedules; including cutting, bending, hooking the bars binding with wires or tack welding and supporting as required etc. complete. (including cost of binding wire) Tor Steel.Lift0.00 m to 5.00 m
128Lift5.00 m to10.00 m(Below G.L )
129Item No. 7 : Providing, and fixing 75 mm dia P.V.C. pipe weep holes at 1.5 M c/c staggered including cost of all materials and labour involved with all leads and lifts etc. complete with all leads and lifts.
130Item No. 8 : Providing and fixing in position C. I. Dapuri steps or 22 mm dia M.S. bar step with proper anchorage, etc. and providing and applying three coats of ant-corrosive paintetc complete as directed by Engineer-in-charge.
131Item No. 9: Providing and filling around the well boulder filling of selected variety and size of boulders including cost of allmaterials, labour, transportation, etc complete with all leads and lifts.
132Item No. 10: Providing stuctural steel work in single stanchions composed of RSJ, channel, etc, with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineer-in-charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted/ bolted / welded connections and one coats of anticorrosive paint and over it two coats of oil painting, etc. complete. ISMB 250 x 125
133Item No. 11: Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour fuel) etc. complete.
134Item No. 12: Providing and fixing G.I. pipe railing having 1.0 M height consisting 50 x 50 x 6 mm thick M. S. angles as verticals at 1.5 M c/c, and additional posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal and painting 3 coats of oil paint over 1 coat of anticorrosive paint of approved colour and shade including cost of all labour, transporting bends to curved shape, etc. complete. As above but with only 2 rows
135Item No. 13: Providing and fixing M.S. chequerredplate flooring of following thickness supported on M.S. angles (25x25x5 mm in size) including welding, cuttting and fabricating the plates to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint etc. complete as directed by engineer in charge. 8 mm thick
136Item No. 14: Carrying out recuperation / yeild test for ascerting the discharge of constructed well / excavated profile as direrted by Engineer in charge.The test carried out by drawing down water from the well/ profile below normal / subsoil water level upto full depth rise in water level is recorded. The normal water level / subsoil water level in the well / profile as well as strainer / suction level at pump as per design of W.S. scheme shall be recorded prior. to the test including cost of all materials.overhead,labours etc. completed as directed.The test shall be carried out as per technical circular No.2597 dt. 20/11/97 and shall be carried out for 7 days.
137Item No. 15: Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete. Reffiling
138Sub work 3 . SWITCH ROOMItem No - 01 Excavation for foundation/pipe trenches in earth,soils of all types,sand, gravel and soft murum,including removing the excavated material upto adistance of 50metres and lifts as below,stacking and spreadingas directed,normal dewatering,preparing the bed for foundation and excluding back filling, etc. complete
139Item No - 02 Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphaltroad byall means including removing the excavated material upto a distance of 50M beyond the area and lifts as below,stacking as directed by Engineer-in-charge,normal dewatering,preparing the bed for foundation and excluding backfilling,etc.complete.
140Item No - 03 Providing and laying in situCC M-15 / 1:2:4 of trap / granite / quarzite/ gniess metal for foundation and bedding including bailing out water, formwork, compacting and curing finishing etc. complete.
141Item No - 04 Providing and laying in situ, cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundation like raft, grillages, strip foundation and footings of reinforced cement concrete columns and steel stanchion including bailing out water, formork, compaction, and finishing, curing etc. complete.A] FOOTING M200
142Item No - 05 Providing and Casting in situ, cement concreteM-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete Columns as per detailed designs and drawing or as directed including centering formork, compacting and roughening the surface if special finish is to be provided and curing etc. complete. FOR COLUMN M-200
143Item No - 06 Providing and Casting in situ, cement concreteM-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete beam and lintelsas per detailed designs and drawing or as directed including centering formork, compaction and finishing the formed surface or roughening the surface if special finish is to be provided and curing etc. complete.PLINTH BEAM M-200/SLAB BEAMM-200
144Item No - 07 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in plinth as backing with composite masonry including bailing out water manually, striking joints, raking out joints and watering complete.Refn. No. : Bd.G.3 Sr. No. 817PWD S.S.R.2021-22 I.No. 27.05P.No. 144
145Item No - 08 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) RCCChajjas/Pardies ( M-200)
146Item No - 09 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement. RCC Slab ( M-200)
147Item No - 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) Tor Steel
148Item No - 11 Providing & fixing steel window and door of various sizes as per detailed drawings fabricated from I.S. standerd sections without hot dip zinc coating without /with ventilators including fabrication , glazing with non acetinic / plain / obscured glass panels of approved type and quality of fixtures and fastening without teak wood boxing, and architraves and finishing with one coat of primer complete. with guard bars 12 mm square bar 10 cm . centre to centre. PWD S.S.R. I.NO. 1137/39.20 P.No.309 DOOR & Windows
149Item No - 12 Providing and fixing in position mild steel door/ window shutters including mild steel angle frame of size 50X 50X 5 mm. for fixing mild steel sheet 24 gauge including welding fixing to frame and all necessary fixtures including electrostatic powder coating etc. complete.PWD S.S.R.21-22 I.No. 1152/39.35P.No. 182 DOOR & Windows
150Item No - 13 Providing internal cement plaster 6 mm. thick in a single coat in cement morter 1:3 without neeru finish to concrete surface in all positions inculding scffolding and curing complete.Internal cement plaster
151Item No - 14 Providing internal cement plaster 12 mm. thick in a single coat in cement morter 1:3 without neeru finish to concrete surface in all positions inculding scffolding and curing complete.Internal cement plaster
152Item No - 15 Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete.Refn. :Bd.L.7 Sr. No. 891PWD S.S.R. 21-22 I.No. 32.11P.No. 153sand faced plasterexternally
153Item No - 16 Provinding and applying white-wash in Two coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete.Refn. :BDP.1A Sr. No. 1026PWD S.S.R.21-22 I.No. 36.03P.No. 167
154Item No - 17 Provinding and applying washable oil-bound distemper of approved colour and shade to old and new surface in two coats including scaffolding preparing the surfaces (excluding the primer coat) etc.complete.Sr. No. 1034PWD S.S.R.21-22 I.No. 36.11P.No 167
155Item No - 18 Provinding and applying three coats of water proof cement paint of approved manufacture and approved colour to the plastered surfacesincluding scaffolding if necessary, cleaning and preparingthe surface watering for two days complete.Sr. No. 1013PWD S.S.R.21-22 I.No. 35.15P.No. 165
156Item No - 19 Provinding and applying two coats of synthetic enamal paint of appoved colour to new stuctral steel work in building, including scaffolding if necessary, cleaning and preparingthe surface (excluding primer coat ) complete.Refn. :BDO.5 Sr. No. 1005PWD S.S.R.21-22 I.No. 35.07P.No. 164
157Item No - 20 Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete. (MJP DSR 2021-22, Sr. No.15, P.No. 45 )
158Subwork No 04 - Puming MachinaryItem No1:- 150mm dia Sub pump set.Providing, erecting and giving test of 3 HP upto 8 Stage 150 mm dia Sub pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump sheel be suitable for various delivery head and discharge with stainless steelshaft. Motor suitable for working on 415(+/-)10% volt 3 ph 50 c/s a.c. supply ,thrust corban bearing with stand entire hy .thrust. pump set shall be direct coupling with suitable strainer .pump should havesuitable discharge out late as per manufacture design .antithrust stream lined non return valve shallbe provided with pump 3mtr submersible copper conductor cable in single /double run, two pairs erection clamp 32 mm wx10mm thickshall be provided with pump.
159Item No. 2a :- 50 mm dia G.I.pipe.providing and errecting ISI mark,heavyclass,50 mm dia G.I. pipewith both end threaded &oneend B class socket.
160Item No. 2b:- M S SPECIALS providing and errecting ISI mark, B class, M S SPECIALS
161Item No. 3a:- 50 mm dia G.I.Bend. providing and errecting ISI mark, B class, 100mm dia G.I.BendwithB class socket(MJP / DSR page no 14 item no pw1-4)
162Item No. 3b:- 50 mm dia G.I.Teeproviding and errecting ISI mark, B class, 100 mm dia G.I.TeewithB class socket
163Item No.4:-Earthing. providing and errecting rod type earthing (electrode of20mm dia solidG.I. Rodor G.I. Pipe of40mmdia ) 2.5 mtr burried in earth or( driven in the earth with blows of moderate force ) with necessarydoubleG.I. earth strip complete errected connected to nearest switch gear earth terminal. (PWD electrical DSR page no 166 / 9-1-4)
164Item No.5:- Flat flexible sub cableproviding and errecting flat flexible submersible cable with copper conductor 3 core , pvc insulated & pvc sheathed cable wire.size : 4 sq mm (motor to panel board). (PWD electrical DSR page no 219 / 12-4-9)
165Item No.6:- Armoured cable.providing and errectingAluminium conductor, XLPE / PVC insulated Armoured cable 3.5 or 4core cable size 16 sq mm(PWD electrical DSR page no 129 / 7-1-15)
166Item No7:- C.I. flanges. providing and errecting ISI mark,80 mm dia C.I. flanges with nut ,bolt &washer (PWD electrical DSR page no 268 / 16-6-29)
167Item No.8:- Channel frame.providing, errecting Channel frame (Mjp/ civil/DSR P.no. 39item no.SEC-F 5)
168Item No.9:- Rain Prinventive box.providing , errecting Box type Rain Prinventive box size=1.5X1X0.30& 22SWG with lock arrangement A( panel box)=6sqmtr (PWD electrical CSR p. no. 112 / 6-1-6)
169Item No10:- plywood . providing , errectingplywood19mmthickness fixed to angle frame with necessary material( PWD electrical DSR p. no.113 / 6-1-14)
170Item No. 11:- Angle frame.providing , errecting & fabrication ofangle framefor panel support ( PWD electrical CSR p. no. 115 / 6-1-19)
171Item No. 12:- Fuse bridge.providing , errecting H C pattern porcelain fuse bridge with base and H C fuse links500 volt, 63Amp.capacity( PWD electrical DSR p. no108 / 5-10-3) )
172Item No. 13:- Triple Pole Switch. providing , errectingtriple pole iron clad /metal cladswitch& fuse 32Amp 415/500 volt. ( PWD/DSR p. no. 87 item no. 5-1-6 )
173Item No. 14:- Change overSwitch. providing , errectingChange overSwitch. clad /metal clad four pole40 Amp 415/500 volt. ( PWD/DSR p. no. 88 item no. 5-1-24)
174Item No. 15:- Volt meter. providing & errectinganalog type moving iron Voltmeterfor ACvoltage 0 to 500 volt range,50 c/s, flash type.( PWD/DSR p. no.117 item no6-3-8 )
175Item No. 16:- Ammeter. providing & errecting analog type moving iron Ammeterfor ACcurrent o to 30 Amp, directrange, 500 volt, 50 c/s flash type.( PWD/DSR p. no. 117 item no.6-3-7 )
176Item No. 17 :- Indicating Lamp. providing & errecting LED type indicating pilot lamp with LED colours RED/ Yellow / Green] 230 / 250 Volt on provided box /panel with necessary material, wring & connectons. ( PWD/DSR p. no. 120 item no.6-5-5 )
177Item No. 18:- Capacitor.providing & errectingbank of metalisedpolypropylene condensers with standard capacities of 1 , 2 , 3 , 5 , 7 , 12 , 15 , 20 & 25 kvar unit P.F. corre-ction operation on 3 ph 50 c/s500 volt + or- 10 %externally dischaging resis-tancs earthing terminals & built up angle iron or chennel iron framework&provided with terminal cover box completed& tested.(MJP Mech. CSR page no47 /cp-1)
178Item No.19:- DOL /FASD Starter.providing & errectingDOL /FASD starterto operate squirrel cage induction motor working on 380-440 volt, 3 phase,50 c/s with no volt coil and over load Relay (range 30 Amp )with nacassary material and connected to supply, etc completed. (MJP Mech. CSR page no48 / LG3-2)
179Item No.20:- Sluice Valve 80 mm dia. providing & errecting in position Sluice Valve-100mm dia and class including necessary jointing accessories (flanges, nut, bolts and rubber packing) as per the specification.(MJP /Civil DSR page no 208&214 item no SECXII-2a(iii)&4(iii)
180Item No. 21:- RefluxValve 80mm dia. providing & errecting in position RefluxValve 100 mm dia and class including necessary jointing accessories (flanges, nut, bolts and rubber packing) as per the specification.(MJP /Civil DSR page no 204&214 item no SECXII-1a(iii)&4(iii)
181Item No. 22:- MS bareels for chain pully Providing and supplying ISI standard MSspecials of required thickness with 3 coats ofapproved make epoxy paint (Shalimar, Ciba orMahindra & Mahindra make) from inside andoutside excluding all statutory duties & taxessuch as GST levied by GOI & GOM in allrespect, inspection charges, transportation tostores / site, and stacking, etc. complete.MS barrels (pipe pieces) locally manufactured(for small quantities)(MJP /Civil DSR page no 72 item no 7f)
182Item No. 23:- Chain pully block of 1 TonProviding, erecting triple spur gear type chain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift tested to 50% over load as per IS 3832 carrying ISI mark.(MJP DSR/Mech page No. 14 Sec. 5 LF 1-1)
183Sub. Work No. 5 :Pure Water Rising MainIteam No. 1 : Providing and supplying in standard lengths ISI Mark rigid unplasticised PVC pieps suitable for potable water with solvent cement joints including cost of solvent cement joints invluding cost of couplers, as per IS specification No. 4985/1988excluding GST levied by GOI & GOM in all respect, including transportation freight charges,transit insurance, inspection charges, loading, unloading, conveyance to stores and stacking the same in closed shed duly protected from sun rays and rains etc complete ( with third party inspection)(socketed)1620m - 90 mm dia.PVC.6.Kg/Cm2.Pipes.
184PVC Specials / T, Bend Etc.
185Iteeam No. 2 : ProvidingISI mark G.I.pipe of following class and diameter including all local and central taxes, octroi, inspection charges, transportation to stores, etc. complete as directed by Engineer- In - Incharge. 80 mm dia.Class-Medium Pipes.
186Iteam No. 3: Providing and supplying ISI mark CID/F ruflex valves (non return valves) of following dia including all taxes (central and local), railway freight, inspection charges unloading from railway wagon loading into truck transporatation up to departmental stores/ site, unloading, stacking etc complete. Without bypass arrangement- PN-1.0A) 80 mm dia.for Non Return Valve
187Iteam No. 4 : Providing and supplying Air Valves as per IS-14845-2000 and MJP\"s standard specifications of approved make and quality of following diameters including all taxxes (Central and Local), railway freight, inspection charges, unloding from railway wagons, loading into truck, transportation upto departmental stores / site, unloading and stacking excluding GST levied by GOI & GOM in all respects etc. complete.25 mm dia Single ball air valvePN-1.6
188Iteam No. 5 : Providingand supplying ISI standard CI flanged/ S& S specials excluding GST levied by GIO & GOM in all railway fright, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc complete as directed as directed by Engineer-in-charge.a) D/F Specials ( 80 to 300 mm dia.) CID/F Tee for Air Valve ( 100 x 80 mm )
189Iteam No. 6 : Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 meters and lifts as below, stacking and spreading as directed, normal dewatering, preapring the bed for foundation and excluding back filling etc. complete. Lift 0 to 1.5 m.Lift - 0.00 To 1.50 M
190Iteam No. 7 : Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift - 0.00 To 1.50 M
191Iteam No. 8 : Excavation for foundation / pipe trenches in hard murum and Boulder W.B.M road including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift - 0.00 To 1.50 M
192Iteam No. 9 : Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift - 0.00 To 1.50 M
193Iteam No. 10 Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift - 0.00 To 1.50 M
194Iteam No. 11 : Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm to 20 cm layers including watering and compaction etc.Murum Bedding
195Item No. 12 : A Lowering, laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, ruber ring, giving satsifactory hydraulic testing as per IS code, etc. complete. ( With cement solvent joint / ring if joint) Working pressure 6 and 10 Kg/Sq.cm.90 mm dia.PVC.6.Kg/Cm2.Pipes.
196Item No. 13 : B Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.90 mm dia.PVC.6.Kg/Cm2.Pipes.
197Item No. 14 : A Lowering, laying and jointing ISI mark G.I.pipe of following class and diameter including all local and central taxes, octroi, inspection Charges, transportation to stosre, etc. complete as directed by Engineer- In - Incharge. 80 mm dia.Class-Medium Pipes.
198Item No. 14 : B Hydraulic testing of G.I pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.80 mm dia.Class-Medium Pipes.
199Item No. 15 : Lowering, laying and jointing in position following C.I. D/F reflux valves, Butterfly valves and sluice valves including cost of all labour jointing material including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves)A) 80 mm dia.CIDF.Sluice Valve / NRV Valve
200Item No. 16 : Providing and fixing in position air valve shaft including providing and fixing GI mediam class of 6 mm thick MS pipe shaft 2.70 m long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including incasing of vertical shaft in PCC M-150 as shown in type desine together with providing and making flanged joints wherever required and fixing of air valve over the shaft in excluding cost of air valve and branched air valve tee etc complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines ( type design attached ) foundation on murum and harder strata.A) Foundation in murum and harder strataUpto 150 mm dia.
201Item No. 17 : Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete.
202Item No. 18 : Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite / quartzite / gneiss metal for incasing of PVC pipe in cement concrete road including dewatering form work, compacting and curing. finishing etc. complete .Cement Concretefor Encasing of PVC pipe
203Subwork No. 6 :RCC E.S.R .CAP - 21000 Ltrs.Staging - 9.0 M.ITEM No. 1: Designing (aesthetically), & constructing RCCelevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters center to center including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling, disposing ofthe surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and joining of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories which accessories such as M.S. ladder, C.I. manhole frame and covers water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case form ground level to roof level, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three costs of cement paint to the structure including roof slab and giving satisfactory water tightness test as per I.S. co Notes Item No. 1 contd…1. The design of the structure be in accordance with relevant I.S. 3370- 1965 or revised.2. The design shall satisfy the stipulations as per I.S. 1893-1984 and I.S. 13920/1993 for seismic force and I.S. – 11682/1985 for RCC staging of overhead tanks.3. For design having more than 6 columns , provision of internal bracing is obligatory.4. The entire structure shall be in M –250 mix only.5. Plain round mild steel bars grade- I confirming to I.S. 432 part I or high yield strength deformed bars confirming to I.S. 1786 or I.S. 1139 shall be used, grade 0 II mild steel bars will not be allowed.ITEM No. 1:- Contd…6.Irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level.7.These rates include providing M.S. ladder for E.S.R.s up to 2 lakh liters capacity and providing spiral staircase for E.S.R. above 2 lakh liters capacity.8. Stagingshall have to be designed with stresses of M.- 150 concrete but actual construction shall be done in M- 250 concrete with sections worked out with M-150 design. 9. These rates are including the cost of uplift pressure if any entire dewatering during execution.10. All conditions given in the Member Secretary’sCircular No. MJP/TS-I/350/ 1668 Dt. 2-8-97 and MJP/TS/-I/I/2127 Dt. 13-7-99 shall be strictly followed and additional cost.If any, due to these conditions is included in the rates mentioned below.11. 75 % part rate shall be payable for reinforcement concrete plastering items of containers of E.S.R. till satisfactory hydraulic testing for water tightness is given, and till that work shall be treated as incomplete.
204ITEM No.2:- Providing and supplying ISI standard CI double flanged pipes including all taxes ( Central and local ) railway fight, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc. complete as directed by Engineer-in-charge.i) 80 mm dia (For Inlet & Overflow)
205iI) 100 mm dia (For Outlet)
206ITEM No. 3:- Providingand supplying ISI standard CI flanged/ S& S specials excluding GST levied by GIO & GOM in all railway fright, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc complete as directed as directed by Engineer-in-charge. a) D/F Specials
207ITEM No. 4:- Providing, double flanged Sluice Valves conforming to IS-14846 including worm gear arranegments as per test pressure,stainless steel spindle, caps including inspection charges ,transportation up to departmental store , unloading stacking excluding GST levied by GOI & GOMin all respect etc. complete . Sluice valves Without bypass arrangement- PN-1Sluice valves as per I.S. 780 & 2906-1984.i) 80 mm dia
208i) 100 mm dia
209Sub. Work No. 7 : Distribution Network PVC.4.Kg/Cm2.Pipes.Item No. 1 : Providing and supplying in standard lengths ISI Mark rigid unplasticised PVC pieps suitable for potable water with solvent cement joints including cost of couplers, as per IS specification No. 4985/1988 including all local central taxes, transportation fright charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement etc. complete. (Selffit type to be jointed with cement solvent.) Working pressure 4 Kg/Sq.cm75 mm dia.PVC.4.Kg/Cm2.Pipes.
21090 mm dia.PVC.4.Kg/Cm2.Pipes.
211110 mm dia.PVC.4.Kg/Cm2.Pipes.
212PVC Specials bend tee etc
213Item No. 2 : Providing, double flanged Sluice Valves conforming to IS-14846 including worm gear arranegments as per test pressure,stainless steel spindle, caps including inspection charges ,transportation up to departmental store,unloading stacking excluding GST levied by GOI & GOMin all respect etc. complete . Sluice valves Without bypass arrangement- PN-1 65 mm dia.Sluice Valves
21480 mm dia.Sluice Valves
215100 mm dia.Sluice Valves
216Item No. 3 : Excavation for foundation/pipe trenches in earth, soils of all types of sand gravel & soft murum including removing the excavated material upto a distance of 50 M. & lift as below.stacking and spreading as directed, Normal dewatering, preparing the bed for foundation & excluding backfilling etc complete. Lift - 0.00 To 1.50 M
217Item No. 4 : Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Lift - 0.00 To 1.50 M
218Item No. 5 : Excavation for foundation/ pipe trenches in hard murum & boulders.W.B.M. road including removing the excavated material upto a distance of 50 m beyond the area and lifts as below stacking and spreading as directed by Engineer- in-charge, normal dowering preparing the bed for foundation & excluding backfilling etc complete. Lift - 0.00 To 1.50 M
219Item No. 6 : Excavation for foundation/ pipe trenches in soft rock & old cement and lime masonry foundation asphalt road by all means including removing the excavated material upto a distance of 50 m beyond the area and lifts as below stacking as directed by Engineer-in-charge,normal dowering preparing the bed for foundation & excluding backfilling etc complete Lift - 0.00 To 1.50 M
220Item No. 7 : Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling,wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed,removingthe excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) Lift - 0.00 To 1.50 M
221Item No. 8 : Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm to 20 cm layers including watering and compaction etc. Murum Bedding
222Item No. 9 A:Lowering, laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, ruber ring, giving satsifactory hydraulic testing as per IS code, etc. complete. ( With cement solvent joint / ring if joint) Working pressure 6 and 10 Kg/Sq.cm. 75 mm dia.PVC.4.Kg/Cm2.Pipes.
22390 mm dia.PVC.4.Kg/Cm2.Pipes.
224110 mm dia.PVC.4.Kg/Cm2.Pipes.
225Item No. 9B :Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 75mm dia.PVC.4.Kg/Cm2.Pipes.
22690 mm dia.PVC.4.Kg/Cm2.Pipes.
227110 mm dia.PVC.4.Kg/Cm2.Pipes.
228Item No. 10A :Lowering, laying and jointing in position following C.I. D/F reflux valves, Butterfly valves and sluice valves including cost of all labour jointing material including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves) 65 mm dia.Sluice Valves
22980 mm dia.Sluice Valves
230100 mm dia.Sluice Valves
231Item No. 10 : B Giving satisfactory hydraulic testing of followingC.I. D/F reflux valves, Butterfly valves and sluice valves etc. complete. 65 mm dia.Sluice Valves
23280 mm dia.Sluice Valves
233100 mm dia.Sluice Valves
234Item No. 11 : Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete.
235Item No. 12 : Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavatin, B.B. masonry in C.M. 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. Note : wall thickness : 0.23 m for depth of 0.9 m and 0.35 m for balance depth exceeding 1.2 m)60 x 45 cm size and depth of 0.90 mwith precast RCC slab Cover
236Item No. 13 : Providing and fixing C.I. Road box including loading .unloading and carting to site of work including all necessary excavation in all types strata and fixing in murum packing, etc complete. 100 mmx 225 mm (20 kg)
237Item No 15 :Re-instating damaged roads surface during lowering & laying of pipeline of distribution system.a) For Concrete Road Re- instating b) Qty Of CC Road
238Sub. Work No.9 Trial and RunIteam No. 1 Commissioning running and maintaining the scheme to quantites,rated capacity,including manning necessary personnel such as operator, valveman etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP/Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer - in - charge.Note :- Required chemicals to be supplied by Department free of cost and electricity bill will also be paid by the Department.A) For single village. ( Three Months )
239GST 12%

AI Tender Summary

OUR REF NO 31457187
AUTHORITY Government Departments
TENDER VALUE 84.67 Lakhs
LAST DATE 22-03-2022
Authority
Authority Name Rural Development Department
Work Description Water Supply Scheme At.Kekat Sindgi Tq.Jalkot Dist.Latur.
Basic Detail
Tender No ZPL/RWS/JJM/ET-12/42/2021-22
Bidding Type Tender
Location
City sindgi
State Maharashtra
Key Dates
Publish Date 14 Mar 2022
Submission Date 22 Mar 2022
Open Date 23 Mar 2022
Finance
Tender Value 84.67 Lakhs
Tender Fee 5000
EMD 84676
Exemption Not Available
Document List
56468f3e-9e31-4568-a5bb-31204f07b393.html
BOQ_1342269.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 14, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 22, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 23, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

56468f3e-9e31-4568-a5bb-31204f07b393.html

xls

BOQ_1342269.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders