| 1 | Excavation in trenches not exc. 1.5 mtr wide and not exc 1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable as in hard/dense of soil and getting out, complete all as specified and directed. |
| 2 | All as per Srl item No 01 here-in-before above but depth exceeding 1.5 m in depth and not exceeding 3 m, complete all as specified and directed. |
| 3 | Returning filling, including spreading, leveling , watering and well ramming in layers not exceeding 25 cm in hard/dense of soil, complete all as specified and directed. |
| 4 | Removal of excavated materiali.e. soil to a distance not exc. 50m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed. |
| 5 | Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying,complete all as specified in clause 19.75 of SSR Part-I.Note :- 1. Dry fine sand of best available quality shall be used.2. Punned thickness shall be measured and paid. |
| 6 | Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. |
| 7 | M & L for PCC 1:4:8 Type D-2 (using 40mm graded aggregate) as in Bed of poles streets and stay complete all as specified and as directed by the Engineer-in-Charge. |
| 8 | M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge. |
| 9 | Plain cement concrete1:2:4, type C-2, (using 40 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating and includingnecessary form work complete all as specified and directed. |
| 10 | S & F for 40mm bore `Light grade` GI tubing ISI marked with cutting as required and bend to shape for fixing with electric poles as cable protection fixed on pole or laid in trenches under floor,duct etc with fixing clamps,nuts bolts etc complete all as specified and as directed. |
| 11 | S & F for 25mm bore `Light grade` GI tubing ISI marked with cutting as required and bend to shape for fixing with electric poles as cable protectionfixed on pole or laid in trenches under floor,duct etc with fixing clamps,nuts bolts etc complete all as specified and as directed. |
| 12 | M & L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size,for HT,25X20cm size, , complete all as specified and as directed by the Engineer-in-Charge |
| 13 | Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws,poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-55 (11.0 metres long)including drilling of holes of reqd size for fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately,and making pole NO.with black paint at suitable height complete all specified and directed. |
| 14 | Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws,poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-31 (9.0 metres long)including drilling of holes of reqd size for fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black & bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately,and making pole NO.with black paint at suitable height complete all specified and directed. |
| 15 | Materail and labour for installation of Aluminium Conductor Steel Reinforced,of any size (as required ), with copper binding wire or aluminium tapes which shall not be included in weight of conductor, complete all as specified and directed. |
| 16 | Materail and labour for installation of 11 kv 3 Core overhead lines on existing poles with XLPE insulated Aerial Bunched Cable , ISI Marked (with 70 sq mm bore steel conductor) or 11 kv insulated conductor connected on insulators,cable /conductor size of 95 sq mm complete all as specified and directed. |
| 17 | M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of aluminium paint over one coat of red oxide primer, \"as in repair\" complete all as specified and directed. |
| 18 | M & L for Loop type insulator,vitreous porcelain, white, brown or green, large size, with overall dimensions 90 x 140mm clearance of hole 25.5mm, complete all as specified and as directed. |
| 19 | M & L of shackle type, porcelain (or polymer insulator if required , vitreous,white brown or green insulators for working pressure in 1100 volts , Height in 100 mm and Max 115 mm dia, Galvanised steel fittings Section of straps in 31 x 3 mm and 12 mm dia of bolts, fixed \"as in repair\"complete all as specified and directed. |
| 20 | M & L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 100 mm dia for 550 volts grade 100mm height 65mm dia for 1100 volts grade, fixedas in repai complete all as specified and directed. |
| 21 | M & L for disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, two-in-seriesdisc assembly for tension with tension clamp for conductor of working pressure 11000 volts, fixed as in repair complete all as specified and directed. |
| 22 | M & L of shackle type, porcelain (or polymer insulator if required , vitreous,white brown or green insulators for working pressure in 11000 volts , Height in 150 mm and Max 150 mm dia, Galvanised steel fittings Section of straps in 38 x 5 mm and 20 mm dia of bolts,fixed \"as in repair\"complete all as specified and directed. |
| 23 | M & L for pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade 150mm height 150mm dia for 11000 volts grade, fixed as in repai complete all as specified and directed. |
| 24 | M & L for stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), Diameter of stay rod in 20 mm, fixed as in repair complete all as specified and as directed. |
| 25 | M & L for painting to HT poles, 11 mtr, with cross arms, bracing and clamps, one coat of aluminium paintincluding preparation of the old paint carefully to make smooth complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30 cm height with one coat of synthetic enamel paint all as specified and directed. |
| 26 | Restretching of LT / HT ACSR conductor and GI wire of any size and any type of poles carring upto six conductor in a span including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line sapns, line separator, crossarms on poles, complete all as specified and directed. |
| 27 | Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket (bracket included) with impact and corrosion resistant including thermal management in multiple optices completee with IP 65/66 protection cable complete all as specified and directed. |
| 28 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket (bracket included) with impact and corrosion resistant including thermal management in multiple optices completee with IP 65/66 protection cable complete all as specified and directed. |
| 29 | Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket (bracket included) with impact and corrosion resistant including thermal management in multiple optices completee with IP 65/66 protection cable complete all as specified and directed. |
| 30 | M & L for Point wiring with 2.5 Sqmm single core PVC sheathed copper conductor cable, with stove enamelled steel conduit for One light point ( point wiring start from MCB till street light) , controlled by one switch completeall as specified and directed. |
| 31 | M & L for Earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steelincluding PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium graded GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 32x6 mm and protection pipe of 40 mm bore medium graded ,GI light graded 20mm bore watering pipe |
| 32 | Earthing complete with galvanisedearth plate electrode 600mm x 600mmx 6mm thickburied directly in ground vertically ( earth pit of depth not less than 2.25m belowground level ) with top edge of the earthplate not less than 1.5m belownormal groundlevel, connecting with4.00 mmgalvanized steel wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron and earth wire protected by galvanized steel pipe 15mm dia (light grade) including provn of concrete pit in PCC 1:2:4type B-1 (using 20 mm graded mechanically crushed stone aggregate), 40mm thick RCC cover slab 1:2:4 tpye B1 reinforced with XPM ( weight not less than 4kg/sqm ) and frame made of angle iron of section 40x40x6mm with lugs, 02 Nos handle of 6mm dia mild steel bar made to shape, 20mm dia GI pipe (light grade) for watering perforated at bottom 1.75m long placed on top edge of earth plate, charcoal and salt filling in alternate layer, test point made out of phopsphorus/ Bronze with fixing arrangement , funnel wire mesh and earth work in soft/loose soil, returning filling, removal of surplus soil all as shown in electrical plate No.3 of SSR Part-I and connection to earth test pointcomplete, all asspecified including testing on completion.Note : Item of earthing include cost of 7.5m long GI earth wire 4mm dia, ,earth work in soft/ loose soil, returning filling and removal, GI protection pipe, GI watering pipe, funnel, wire wesh, RCC cover, etc . |
| 33 | Supply and fixing 1100 volts grade heavy duty cable ISI marked PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular (size of aluminum conductor in mm2 (4 sq mm) Solid conductor), complete all as specified and as directed by the Engineer-in-Charge |
| 34 | Supply and laying in cable,XLPEinsulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty)1100 Volts grade with stranded aluminium conductor of size 3.5 Core 35 Sqmm, ISI marked complete, all as specified and as directed. |
| 35 | Supply and laying in cable,XLPEinsulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty)1100 Volts grade with stranded aluminium conductor of size 4 Core 25 Sqmm, ISI marked complete, all as specified and as directed. |
| 36 | Supply and laying in cable,XLPEinsulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty)1100 Volts grade with stranded aluminium conductor of size 4 Core 16 Sqmm, ISI marked complete, all as specified and as directed. |
| 37 | Supply installation in replacement, connecting electrically and testing of street light junction box size 450x250x300mm, pole mounted made out of CRCA sheet 2 mm thick, powder coated having door with magnetic lock complete with bus bar 4 Nos suitable for 3 phase 4 wire supply system, made of aluminium strip of size 20x3mm,one single pole MCB, 240 volts \"C\" Curve type, 6 Amps with rupturing capacity 10 KA, including fixing arrangement made of MS FI Clamps of requisite size nuts, bolts and washers complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixingofMCCB 4 pole, 415V, with Adjustable thermal settings, 400 Amps with breaking capacity 36 KA fixed as in repair complete as specified and directed. |
| 39 | Supply and fixingofMCCB 4 pole, 415V, with Adjustable thermal settings, 250 Amps with breaking capacity 36 KA fixed as in repair complete as specified and directed. |
| 40 | Supply and fixingofMCCB 4 pole, 415V, with Adjustable thermal settings, 160 Amps with breaking capacity 36 KA fixed as in repair complete as specified and directed. |
| 41 | Supply and fixing copper thimble of size 25 to 170 sqmm, complete all as specified and directed. |
| 42 | Material and laying in replacement of aluminium bus bars of capacity of 300 Amps rating,insulated with colour coded heat shrink insulation of 1100V grade, with polymer insulators complete all as specified and directed. |
| 43 | Material and Labour for painting of LT panel inside and outside complete with two coats (each coat to be of 0.25mm thick) of water proof electrically insulating enamel paint complete all as specified and directed by Engineer-in-Charge. |
| 44 | Material and Labour for repair of existing LT Panel by cutting corroded locations of the panel and replacement with new powder coated 3.15 mm thick MS sheet (to be measured in sqm based on the the new sheet used) complete all as specified and directed. |
| 45 | Supply and fixing of Changeover, panel mounted, of rating of 250 Amps, LT panels and other equipments fixed \"as in repair complete all as specified and directed. |
| 46 | Supply and fixing of of LCD multifunction meter (secure elite 440 series) with suitable CT to LT panel and other equipmentsfixed as in repair\" complete all as specified and directed. |
| 47 | Supply and fixing of LCD/LED three phase voltmeter complete with all necessary connecting and wiringfixed \"as in repair\" all as specified and directed. |
| 48 | Supply and fixing of LCD/LED three phase Ammeter with suitable CTs complete with all necessary connecting and wiringfixed as in repair all as specified and directed. |
| 49 | Material and labour for making hole in existing pole and cross arms, jointed the cross arms with pole of suitable size anodised nut and bolt (not less than 20 mm dia) and fixing double washers of suitable dia and thickness on both sides to avoid slipping of cross arms, complete all as specified and directed. |