Banking and Finance Cooperative Closing in 0 days TDR #31444322

Strong Room Door Class B With Accessories Strong Room Door Class B With Accessories , Item , Technical Specification Of Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage The Vault ( Strong Room ) Door ( Main Door

Issued by Cooperative · saharanpur, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Mar 2022
0 days left
EMD
10000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
saharanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Strong Room Door Class B With Accessories Strong Room Door Class B With Accessories , Item , Technical Specification Of Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage The Vault ( Strong Room ) Door ( Main Door ) Dimension And Specification Shall Be Strictly Adhering To Is 11188 ( Part-1 ) :2014, The Door Shall Have Bis Label Of Class B Having Torch & Tool Resisting Capacity For Minimum 30 Minutes And Fire Resisting Capacity For Minimum 30 Minutes., The Bidder / Oem Must Possess Valid Bis License To Manufacture And Supply The Aforementioned Trtldoor ( Class B ) , All The Surfaces Of The Door Before Painting Shall Be Thoroughly Degreased And Cleaned Of Rust And Scales Preferably By 12 Tank Pickling Process And Treated Chemically To Prevent From Rusting., The Door Shall Be Painted Inside And Outside With An Anti-Corrosive Primer Followed By Two Undercoats Of Paints And Finally Painted With Quick Drying Paint, Resulting Into Minimum 300 Hrs Of Salt Spray Resistance. ( Attach Certificate / Declaration ) , The Main Door ( Class B ) Shall Consist Of Outer And Inner Mild Steel Plates Conforming To Is 2062:1992 For Plates Up To 20 Mm Thick Strongly Rimmed And Continuously Welded To Form A Single Structure And Tightly Enclosing A Solid Slab Of High Speed Drill Resisting And Oxy Acetylene Torch Resisting Material That Is At Least 50 Mm Thick, Door Frame : The Door Frame And Vestibule Shall Be Welded To One Piece Construction With A Minimum Thickness Of 10 Mm And Shall Grip The Concrete Wall., Rebate : The Rebate Of The Door Frame Shall Be Formed By Mild Steel Sections. The Vertical Rebates Shall Be Riveted Or Welded With The Side Members Of The Door Frame And Shall Conform To Dimensions As Specified By Is 11188., Clenching Mechanism : A Continuous Resilientpacking Shall Be Incorporated In The Frame And A Conpression Mechanism For Clenching The Door Tight Shall Be Provided So As To Protect Against Admission Of Flood Water Or Liquid Explosives. In Locked Position The Door After Clenching Shall Not Have Any Play In The Direction In Which The Door Opens., Thickness Of Door Over Locks : Should Be Of Minimum 90Mm Thickness., The Door Shall Have An Automatic Relocking Device For Each Key Lock Fitted In The Door Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosives Or By Other Means. , Primary Lock Of The Door Shall Have Additional Relocking Device Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosive Or Any Other Means., The Lock Shall Be Dual Control Type And Have At Least 8 Active Levers Of Brass Of Minimum 1.2 Mm Thickness. There Should Not Be Any Dummy ( False ) Levers., The Bidder / Oem Must Be The Original Equipment Manufacturer Of The Locks Used In The Aforementioned Safe. ( Oem Must Give A Written Undertaking On Letterhead And Must Also Give An Noc The Bank For Plant Visit If Needed ) , Lock Case : Should Be Minimum 2 Step Case Construction Covering Entire Jamb Area., The Lock Shall Be Fixed With At Least Four Bolts Of 8 Mm Diameter Such That Any Pressure Applied On The Bolts Either Directly Or Through Handle Of The Door, Is Not Transmitted To The Fixing Screw Of The Lock / Locks. All Working Parts Of The Lock Shall Have Corrosion Resistant Properties Capable Of Withstanding Exposure For 72 H In Standard Salt Spray Test With 5 Percent Salt Solution. , Bolt Work : There Shall Be 6 Locking Bolts Each On The Vertical Edges Of The Door ( Front Edge & Rear Edge ) ., Hinges : Strap Hinges To Be Suitably Bolted To The Door Shultter. The Hinge And Pivot Should Be Such That There Is No Appreciable Friction Or Play For The Movement Of The Door. The Pivots Shall Have Arrangements For Lubrication And A Height Adjustment Bold Is To Be Provided To Adjust Height Of Door Shutter. , Grill Gate ( Inside ) : Ventilating Grill Gate Shall Be Made Of Mild Steel Angles, Plates Or Channels With Mild Steel Rods Welded In A Rigid Frame. The Grill Gate Shall Be Hinged In Strong Room Door Frame Such That It Opens Inside. An Unpickable Dual Control Locking Device Capable Of Being Operated From Both The Sides Of The Door Shall Be Fitted In The Grill Gate. , Emergency Door : The General Specifications Of Emergency Door Shall Remain As For The Main Door Except For Bolt Work. For Bolt Work, There Shall Be 3 Locking Bolts Each On The Vertical Edges Of The Emergency Door ( Front Edge & Rear Edge ) ., Limit Switch / Lighting Control: Vault Lighting Control Shall Be Fitted On The Main Door To Automatically Control The Electric Supply To The Vault.

BOQ

Name of Work: STRONG ROOM DOOR CLASS B WITH ACCESSORIES
Sl. No. Item Description
1ITEM
2TECHNICAL SPECIFICATION OF TRTL VAULT (STRONG ROOM) DOOR (CLASS-B) WITH EXHAUST FAN, VENTILATOR, V-CAGE The Vault (Strong Room) Door (Main Door) dimension and specification shall be strictly adhering to IS 11188 (Part-1):2014, The Door shall have BIS Label of Class B having Torch & Tool Resisting capacity for minimum 30 minutes and Fire Resisting Capacity for minimum 30 minutes.,The bidder/OEM must possess Valid BIS License to manufacture and supply the aforementioned TRTLDoor (Class B),All the surfaces of the Door before painting shall be thoroughly degreased and cleaned of rust and scales preferably by 12 tank pickling process and treated chemically to prevent from rusting., The Door shall be painted inside and outside with an anti-corrosive primer followed by two undercoats of paints and finally painted with quick drying paint, resulting into minimum 300 hrs of salt spray resistance. (Attach certificate/declaration), The main door (class B) shall consist of outer and inner mild steel plates conforming to IS 2062:1992 for plates up to 20 mm thick strongly rimmed and continuously welded to form a single structure and tightly enclosing a solid slab of high speed drill resisting and oxy acetylene torch resisting material that is at least 50 mm thick, Door Frame : The door frame and vestibule shall be welded to one piece construction with a minimum thickness of 10 mm and shall grip the concrete wall., Rebate : the rebate of the door frame shall be formed by mild steel sections. The vertical rebates shall be riveted or welded with the side members of the door frame and shall conform to dimensions as specified by IS 11188., Clenching mechanism : A continuous resilientpacking shall be incorporated in the frame and a conpression mechanism for clenching the door tight shall be provided so as to protect against admission of flood water or liquid explosives. In locked position the door after clenching shall not have any play in the direction in which the door opens., Thickness of door over locks : Should be of minimum 90mm thickness., The Door shall have an automatic relocking device for each Key lock fitted in the door which being always on guard shall come into operation if lock is dislodged by explosives or by other means. , Primary lock of the door shall have additional relocking device which being always on guard shall come into operation if lock is dislodged by explosive or any other means., The lock shall be dual control type and have at least 8 active levers of brass of minimum 1.2 mm thickness. There should not be any dummy (false) levers., The bidder/OEM must be the Original Equipment manufacturer of the Locks used in the aforementioned Safe. (OEM must give a written undertaking on Letterhead and must also give an NOC the bank for plant visit if needed), Lock Case : Should be minimum 2 step case construction covering entire jamb area., The lock shall be fixed with at least four bolts of 8 mm diameter such that any pressure applied on the bolts either directly or through handle of the door, is not transmitted to the fixing screw of the lock/locks. All working parts of the lock shall have corrosion resistant properties capable of withstanding exposure for 72 h in standard salt spray test with 5 percent salt solution. , Bolt Work : There shall be 6 locking bolts each on the vertical edges of the door (Front edge & Rear edge).,Hinges : Strap hinges to be suitably bolted to the door shultter. The hinge and pivot should be such that there is no appreciable friction or play for the movement of the door. The pivots shall have arrangements for lubrication and a height adjustment bold is to be provided to adjust height of door shutter. ,Grill Gate (Inside) : Ventilating Grill Gate shall be made of mild steel angles, plates or channels with mild steel rods welded in a rigid frame. The grill gate shall be hinged in strong room door frame such that it opens inside. An unpickable dual control locking device capable of being operated from both the sides of the door shall be fitted in the grill gate. , Emergency Door : The general specifications of Emergency Door shall remain as for the main door except for Bolt Work. For Bolt Work, there shall be 3 locking bolts each on the vertical edges of the emergency door (Front edge & Rear edge)., LIMIT SWITCH/LIGHTING CONTROL: Vault lighting control shall be fitted on the Main Door to automatically control the electric supply to the vault.

AI Tender Summary

OUR REF NO 31444322
AUTHORITY Cooperative
TENDER VALUE Ref. Documents
LAST DATE 21-03-2022
Authority
Authority Name Uttar Pradesh Cooperative Bank Limited
Work Description Strong Room Door Class B With Accessories Strong Room Door Class B With Accessories , Item , Technical Specification Of Trtl Vault ( Strong Room ) Door ( Class-B ) With Exhaust Fan, Ventilator, V-Cage The Vault ( Strong Room ) Door ( Main Door ) Dimension And Specification Shall Be Strictly Adhering To Is 11188 ( Part-1 ) :2014, The Door Shall Have Bis Label Of Class B Having Torch & Tool Resisting Capacity For Minimum 30 Minutes And Fire Resisting Capacity For Minimum 30 Minutes., The Bidder / Oem Must Possess Valid Bis License To Manufacture And Supply The Aforementioned Trtldoor ( Class B ) , All The Surfaces Of The Door Before Painting Shall Be Thoroughly Degreased And Cleaned Of Rust And Scales Preferably By 12 Tank Pickling Process And Treated Chemically To Prevent From Rusting., The Door Shall Be Painted Inside And Outside With An Anti-Corrosive Primer Followed By Two Undercoats Of Paints And Finally Painted With Quick Drying Paint, Resulting Into Minimum 300 Hrs Of Salt Spray Resistance. ( Attach Certificate / Declaration ) , The Main Door ( Class B ) Shall Consist Of Outer And Inner Mild Steel Plates Conforming To Is 2062:1992 For Plates Up To 20 Mm Thick Strongly Rimmed And Continuously Welded To Form A Single Structure And Tightly Enclosing A Solid Slab Of High Speed Drill Resisting And Oxy Acetylene Torch Resisting Material That Is At Least 50 Mm Thick, Door Frame : The Door Frame And Vestibule Shall Be Welded To One Piece Construction With A Minimum Thickness Of 10 Mm And Shall Grip The Concrete Wall., Rebate : The Rebate Of The Door Frame Shall Be Formed By Mild Steel Sections. The Vertical Rebates Shall Be Riveted Or Welded With The Side Members Of The Door Frame And Shall Conform To Dimensions As Specified By Is 11188., Clenching Mechanism : A Continuous Resilientpacking Shall Be Incorporated In The Frame And A Conpression Mechanism For Clenching The Door Tight Shall Be Provided So As To Protect Against Admission Of Flood Water Or Liquid Explosives. In Locked Position The Door After Clenching Shall Not Have Any Play In The Direction In Which The Door Opens., Thickness Of Door Over Locks : Should Be Of Minimum 90Mm Thickness., The Door Shall Have An Automatic Relocking Device For Each Key Lock Fitted In The Door Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosives Or By Other Means. , Primary Lock Of The Door Shall Have Additional Relocking Device Which Being Always On Guard Shall Come Into Operation If Lock Is Dislodged By Explosive Or Any Other Means., The Lock Shall Be Dual Control Type And Have At Least 8 Active Levers Of Brass Of Minimum 1.2 Mm Thickness. There Should Not Be Any Dummy ( False ) Levers., The Bidder / Oem Must Be The Original Equipment Manufacturer Of The Locks Used In The Aforementioned Safe. ( Oem Must Give A Written Undertaking On Letterhead And Must Also Give An Noc The Bank For Plant Visit If Needed ) , Lock Case : Should Be Minimum 2 Step Case Construction Covering Entire Jamb Area., The Lock Shall Be Fixed With At Least Four Bolts Of 8 Mm Diameter Such That Any Pressure Applied On The Bolts Either Directly Or Through Handle Of The Door, Is Not Transmitted To The Fixing Screw Of The Lock / Locks. All Working Parts Of The Lock Shall Have Corrosion Resistant Properties Capable Of Withstanding Exposure For 72 H In Standard Salt Spray Test With 5 Percent Salt Solution. , Bolt Work : There Shall Be 6 Locking Bolts Each On The Vertical Edges Of The Door ( Front Edge & Rear Edge ) ., Hinges : Strap Hinges To Be Suitably Bolted To The Door Shultter. The Hinge And Pivot Should Be Such That There Is No Appreciable Friction Or Play For The Movement Of The Door. The Pivots Shall Have Arrangements For Lubrication And A Height Adjustment Bold Is To Be Provided To Adjust Height Of Door Shutter. , Grill Gate ( Inside ) : Ventilating Grill Gate Shall Be Made Of Mild Steel Angles, Plates Or Channels With Mild Steel Rods Welded In A Rigid Frame. The Grill Gate Shall Be Hinged In Strong Room Door Frame Such That It Opens Inside. An Unpickable Dual Control Locking Device Capable Of Being Operated From Both The Sides Of The Door Shall Be Fitted In The Grill Gate. , Emergency Door : The General Specifications Of Emergency Door Shall Remain As For The Main Door Except For Bolt Work. For Bolt Work, There Shall Be 3 Locking Bolts Each On The Vertical Edges Of The Emergency Door ( Front Edge & Rear Edge ) ., Limit Switch / Lighting Control: Vault Lighting Control Shall Be Fitted On The Main Door To Automatically Control The Electric Supply To The Vault.
Basic Detail
Tender No 4380/admin/deadstock/2021-22
Bidding Type Tender
Location
City saharanpur
State Uttar Pradesh
Key Dates
Publish Date 12 Mar 2022
Submission Date 21 Mar 2022
Open Date 22 Mar 2022
Finance
Tender Value Ref. Documents
Tender Fee 590
EMD 10000
Exemption Not Available
Document List
a11a0484-8ec5-42ae-830c-1f64ca15f149.html
BOQ_1081678.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 12, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 21, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 22, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a11a0484-8ec5-42ae-830c-1f64ca15f149.html

xls

BOQ_1081678.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender