Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #31441214

Const And Successful Testing And Commissioning Of 0.10 Mgd Rfsp ( Cost Shall Include , Clari-Floculator, Flash Mixer, Filter House . Wash Water Disposal Chamber ) At Amad Zoo.Wss. Wagad Const And Successful Testing And Commissioning Of 0.10 Mgd Rfsp

Issued by Government Departments · bijbehara, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Mar 2022
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bijbehara → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Const And Successful Testing And Commissioning Of 0.10 Mgd Rfsp ( Cost Shall Include , Clari-Floculator, Flash Mixer, Filter House . Wash Water Disposal Chamber ) At Amad Zoo.Wss. Wagad Const And Successful Testing And Commissioning Of 0.10 Mgd Rfsp ( Cost Shall Include , Clari-Floculator, Flash Mixer, Filter House . Wash Water Disposal Chamber ) At Amad Zoo.Wss. Wagad

BOQ

Name of Work:Construction and successful testing and commissioningof 0.10 MGD Rapid Sand Filtration Plant(Cost Shall include , Clari-Floculator, Flash Mixer, Filter House & Wash Water Disposal Chamber) at Amad Zoo.WSS. Wagad
Sl. No. Item Description
1Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
2Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.
3Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.
4Beyond 30 cm girth upto and including 60 cm girth.
5Beyond 60 cm girth upto and including 120 cm girth.
6Beyond 120 cm girth upto and including 240 cm girth.
7Above 240 cm girth
8Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. (All kinds of soil)
9Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material :All kinds of soil :
10All kinds of soil :
11Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.
12All kinds of soil :
13Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:
141 meter from cutting edge
1525 meter beyond 1 m from cutting edge
1650 meter beyond 1 m from cutting edge
17Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:
18All kinds of soil :
19Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.
20Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete. (Measurements to be taken of the face area timbered).
21Depth exceeding 1.5 m but not exceeding 3 m
22Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
23Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge.
24Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
25Providing and laying hand packed stone soling 50 mm nominal size including filling, spreading, dressing,ramming, all leads lifts and all carriages complete.
26Supply and filling of filter media from approved source - Gravel (Graded gravel - size ranging from 2.0mm to 40.00 mm) in filter beds. Including all carriages, complete job
27Supply and filling of filter media from approved source - Sand (Coarse filter sand - in filter beds. Including all carriages, complete job
28Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.
29Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
30Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
311:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)
321:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
331:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
34Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level
351:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
36Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.
371:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
38Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with:
391:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
40Providing and laying upto floor v level reinforced cement concrete in kerbs, steps and the like including curing but excluding the cost of centering, shuttering, finishing and reinforcement with:
411:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
42Reinforced cement concrete work in arches, arch ribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with:
431:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size
44Reinforced cement concrete work in chimneys, shafts upto floor five level including curing complete but excluding the cost of centering, shuttering, finishing and reinforcement with:
451:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
46Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately.
47All works upto plinth level
48All works above plinth level upto floor V level
49Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately.5.35.1 Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)
50Extra for R.C.C./B.M.C./R.M.C. work above floor V level for each four floors or part thereof.
51Add or deduct for using more or less cement in the items of design mix over and above the specified cement content therein.
52Centering and shuttering including strutting, propping etc. and removal of form for:
53Foundations, footings, bases of columns etc. for mass concrete.
54Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
55Suspended floors, roofs, landings, balconies and access platforms.
56Lintel, beams, plinth beams, girders, bressumers and cantilevers.
57Columns, pillars, piers, abutments, posts and struts.
58Stairs (excluding landings) except spiral staircases.
59Spiral staircases (including landings)
60Arches, domes, vaults upto 6 m span
61Extra for arches, domes, vaults exceeding 6 m span
62Chimney and shafts
63Extra for shuttering in circular work (20% of respective centering and Shuttering items)
64Edges of slabs and breaks in floors and walls
65Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured).
66Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
67Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)
68Steel reinforcement for R.C.C. work ready to use \"cut and bend\" rebars of approved make from factory/workshop to construction site including placing in position and binding allcomplete upto plinth level.
69Thermo-Mechanically Treated bars of grade Fe-500D or more.
70Steel reinforcement for R.C.C. work ready to use \"cut and bend\" rebars of approved make from factory/workshop to construction site including placing in position and binding allcomplete above plinth level.
71Thermo-Mechanically Treated bars of grade Fe-500D or more.
72Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :
73Cement mortar 1:4 ( 1 cement : 4 coarse sand)
74Cement mortar 1:6 ( 1 cement : 6 coarse sand)
75Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
76Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fastenersshall be paid for separately):
77First class kail wood
78Pre-laminated particle board with decorative lamination on both sides,Grade I, Type II IS : 12823 marked
79Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
80First class kail wood (30 mm thick shutter)
81Second kail wood(30 mm thick shutter)
82Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete.
83With Galvanized M.S. Wire gauge with wire of dia 0.63 mm
84With 2nd class teak wood beading 62x19 mm
854 mm thick glass pane (weighing not less than 10 kg/sqm)
86Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
87Using M.S. angles 40x40x6mm for diagonal braces.
88Using flats 30x6mm for diagonal braces and central cross piece.
89Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. chequered plate wherever required, all complete.
90In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required.
91In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
92Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
93M.S. tube
94E.R.W. tubes
95G.I. pipes
96Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
97Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
98Riveted and bolted
99Welded
100Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters
10180x1.25 mm M.S. laths with 1.25 mm thick top cover
102Providing and fixing ball bearing for rolling shutters.
103Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete.
10440mm thick with 20 mm nominal size stone aggregate.
10550 mm thick with 20mm nominal size stone aggregate.
106Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including skirting in vertical & pointing the joints with white cement and matching pigment etc., complete
107In colour such as White, Ivory, Grey, Fume, Red Brown (as dirrected by the engineer incharge)
108Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including skirting in vertical, rubbing, polishing and curing complete with:
109Makrana White Second quality (16mm)
110Extra for pre finished nosing to treads of steps of marble stone
111Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 meter.
11212mm Cement plaster finished with a floating coat of neat cement of mix:
1131 : 3 ( 1 cement : 3 fine sand)
1141 : 4 ( 1 cement : 4 fine sand)
1156 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
116CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 15mm Cement plaster on the rough side of single or half brick wall of mix:
1171 : 4 ( 1 cement : 4 fine sand)
1181 : 6 ( 1 cement : 6 fine sand)
119Pointing on brick work in 1 cement : 3 sand mix. flush/ruled/structure or weathered pointing
120Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
121Applying priming coat:
122With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
123With ready mixed aluminum primer of approved brand and manufacture on resinous wood and ply wood
124With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works
125With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat)
126Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.
127Two or more coats on new work
128Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
129Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete
130On steel work
131On concrete work
132Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade
133Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer.
134Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc.complete
135125 mm
136100 mm
137Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
138150x10 mm
139100x10 mm
140Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
1410.50 mm thick with zinc coating not less than 275 gram/m2
142Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete
1430.80 mm thick with zinc coating not less than 275 gram/m2
1440.63 mm thick with zinc coating not less than 275 gram/m2
1450.50 mm thick with zinc coating not less than 275 gram/m2
146Providing and fixing plained eaves boarding. 2nd class kail wood
147250x32 mm (nominal size )
148300x40 mm (nominal size)
149Providing and fixing of 0.5mm Color GS Sheet Soffitboardingincluding Backing, supports etc complete job
150Providing and fixing plained eaves boarding. (II Class kail Wood)
151250x32 mm (nominal size )
152300x40 mm (nominal size)
153Providing and fixing of 0.5mm Color GS Sheet Soffitboardingincluding Backing, supports etc complete job
154Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1551 mm thick
1562 mm thick
157Providing and fixing G.I. pipes (B medium) complete with G.I. fittings excluding trenching and refilling etc. (external work)
15815 mm dia. nominal bore
15920 mm dia. nominal bore
16025 mm dia. nominal bore
16132 mm dia. nominal bore
16240 mm dia. nominal bore
16350 mm dia. nominal bore
16465 mm dia. nominal bore
16580 mm dia. nominal bore
166100 mm dia. nominal bore
167150 mm dia. nominal bore
168Providing and fixing D.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments.
16980 mm dia. Class 1
170100 mm dia. Class 1
171125 mm dia. Class 1
172150 mm dia. Class 1
173200 mm dia. Class 1
174250 mm dia. Class 1
175300 mm dia. Class 1
176350 mm dia. Class 1
177Providing and laying D.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS : 9523 (as per site requirement)
178Up to 300 mm dia.
179Over 300 mm dia.
180Providing and fixing of MS flanged joints (12mm thick) to double flanged GI/DI pipes including cutting of pipes, welding charges, cutting of flanges, rubber gasket, bolts, nuts including testing of joint and all sorts of carriages. Complete Job.
18180 mm dia. pipe
182100 mm dia. pipe
183125 mm dia. pipe
184150 mm dia. pipe
185200 mm dia. pipe
186250 mm dia. pipe
187300 mm dia. pipe
188350 mm dia. Pipe
189Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete.
190Serrated with central bulb (225 mm wide, 8-11mm thick)
191Dumb bell with central bulb (180mm wide, 8mm thick)
192Kickers (320mm wide, 5mm thick)
193Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage
194Providing & fixing of 0.63mm thick PGI sheets at construction joints including all leads and lifts complete job as directed by Engineer-in-charge
195Providing and fixing aluminum work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 andIS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides withrequired EPDM rubber / neoprene gasket felt etc. Aluminum sectionsshall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.)
196Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)
197Powder coated aluminum (minimum thickness of powder coated 50 microns)
198Polyester powder coated aluminum (minimum thickness ofpolyester powder coated 50 microns)
199For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)
200Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)
201Powder coated aluminum (minimum thickness of powder coated 50 microns)
202Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns)
203Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)
204With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm)
205With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
206With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm)
207Providing & fixing of PVC under drainage laterals with specifications conforming to IS-4985 & IS-15801, 8mm thick fabricated out of approved make with nominal dia of 9mm perforations as per design of bed provided at 60 degrees along with PVC Tees and end caps grouted in concrete, the pressure rating of 10kg/sq cm
20850 mm dia
20962.5 mm dia
21075 mm dia
211100 mm dia
212Carriage of materials by mechanical transport including loading, unloading, stacking of materials - SAND:
2133 km
2144 km
2155 Km
216Beyond 5 km upto 10 km per km
217Beyond 10 km upto 20 km per km
218Beyond 20 km per additional km
219Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Aggregate below 40mm :
2203 km
2214 km
2225 km
223Beyond 5 km upto 10 km per km
224Beyond 10 km upto 20 km per km
225Beyond 20 km per additional km
226Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Aggregate 40mm and above :
2273 km
2284 km
2295 Km
230Beyond 5 km upto 10 km per km
231Beyond 10 km upto 20 km per km
232Beyond 20 km per additional km
233Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Stone Soling :
2343 km
2354 km
2365 Km
237Beyond 5 km upto 10 km per km
238Beyond 10 km upto 20 km per km
239Beyond 20 km per additional km
240Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Steel/ CGI Sheets:
2413 km
2424 km
2435 Km
244Beyond 5 km upto 10 km per km
245Beyond 10 km upto 20 km per km
246Beyond 20 km per additional km
247Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Earth:
2483 km
2494 km
2505 Km
251Beyond 5 km upto 10 km per km
252Beyond 10 km upto 20 km per km
253Beyond 20 km per additional km
254Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Cement:
2553 km
2564 km
2575 Km
258Beyond 5 km upto 10 km per km
259Beyond 10 km upto 20 km per km
260Beyond 20 km per additional km
261Carriage of materials by mechanical transport including loading, unloading, stacking of materials - Bricks:
2623 km
2634 km
2645 Km
265Beyond 5 km upto 10 km per km
266Beyond 10 km upto 20 km per km
267Beyond 20 km per additional km
268Carriage of materials by mechanical transport including loading, unloading, stacking of materials - wood:
2693 km
2704 km
2715 Km
272Beyond 5 km upto 10 km per km
273Beyond 10 km upto 20 km per km
274Beyond 20 km per additional km
275Carriage of materials by manual means including loading, unloading, stacking of materials- (Sand)
276Ist 50m
277Beyond Ist 50m
278Carriage of materials by manual means including loading, unloading, stacking of materials- Aggregate Below 40mm
279Ist 50m
280Beyond Ist 50m
281Carriage of materials by manual means including loading, unloading, stacking of materials- Aggregate 40mm and Above
282Ist 50m
283Beyond Ist 50m
284Carriage of materials by manual means including loading, unloading, stacking of materials- Stone Soling
285Ist 50m
286Beyond Ist 50m
287Carriage of materials by manual means including loading, unloading, stacking of materials- Steel/CGI Sheets
288Ist 50m
289Beyond Ist 50m
290Carriage of materials by manual means including loading, unloading, stacking of materials- Earth
291Ist 50m
292Beyond Ist 50m
293Carriage of materials by manual means including loading, unloading, stacking of materials- Cement
294Ist 50m
295Beyond Ist 50m
296Carriage of materials by manual means including loading, unloading, stacking of materials- Bricks
297Ist 50m
298Beyond Ist 50m
299Carriage of materials by manual means including loading, unloading, stacking of materials- wood
300Ist 50m
301Beyond Ist 50m
302Electrical Items:Supplying and fixing of 25mm dia. medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
303Providing and carrying out wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl. cost of conduit)
304Providing and carrying out wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2-way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl cost of conduit)
305Providing and carrying out wiring for heating points with 4.0 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular combinedS&S 16Amp along with modular plate, suitable GI box and earthing the point with 2 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excl cost of conduit)
306Providing and carrying out circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (excl. cost of conduit)
3072 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
3082 x 4 sq. mm + 1 x 4 sq. mm earth wire
309Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
310Supply and fixing of two module stepped type Electronic Fan regulator on the existing modular plate switch box including connections but excl cost modular plate etc., as required.
311Supplying and fixing single pole 5 A to 32 A rating, 240V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load in the MCB DB complete with connections, testing and commissioning etc. as required.
312Supplying and fixing double pole 63 Amp 240V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load in MCB DB complete with connections, testing and commissioning etc. as required.
313Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
314Supply of 24-Watt LED slim aluminum panel surface type complete in all respects.
315Supply of 1200 mm sweep Ceiling Fans complete in all respects. Confirming to relevant Indian Standards
316Supply of 200 mm nominal sweep Exhaust Fans including shutter from outside complete.Confirming to relevant Indian Standards
317Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
318Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
319Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
320Supplying and fixing 12-way double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
321Providing, fitting and testing of LED flood light IP65 30W rating to pre-wired electric points on the outside of the Filter House building.
322Providing and laying of armoured cable 95mm, 3.5 core for main service line of reputed make in P.V.C pipes of required dia to accommodate the service line including bends etc., from main transformer to the main panel board including copper thimbles, earth work excavation and filling for laying of cable complete.
323Providing and fitting at site 3-phase, Voltage stabilizer of following ratings, oil emersed, of standard make and quality including accessories as required. The job includes making of connections with main panel board and service line. To be paid in fitted and finished form after testing on full load capacity, complete job.
32410 KVA
32520 KVA
32625 KVA
32730 KVA
32840 KVA
32950 KVA
330Providing and fitting of panel board with angle iron supports and A.C. sheets for fixing of MCCB, change over switch, bus bars etc. The job includes nuts bolts and embedding of supports in cement concrete blocks complete job.
331Providing and fitting of:
332200 Amp. 4 pole Change over of reputed make
333100 Amp 4 pole change over of reputed make.
33464 Amp. 4 pole Change over of reputed make
33532 Amp. 4 pole Change over of reputed make
336200 Amp 3-phase copper bus bar
337100 Amp-Copper bus bar
33864 Amp-Copper bus bar
33932 Amp-Copper bus bar
340100 Amp MCCB
34163 Amp MCCB
34240 Amp MCCB
34316 Amp MCCB
3446 Amp MCCB
3453-phase indicator points
3463-phase voltmeter and Amperemeters
347Providing and fitting of Fancy wall brackets and doom light of reputed make.
348Mechanical Items:Providing & fixing of PVC under drainage laterals with specifications conforming to IS-4985 & IS-15801, 8mm thick fabricated out of approved make with nominal dia of 9mm perforations as per design of bed provided at 60 degrees along with PVC Tees and end caps grouted in concrete, the pressure rating of 10kg/sq cm
34950 mm dia
35062.5 mm dia
35175 mm dia
352100 mm dia
353Providing, fitting, testing and commissioning of following items for Flash Mixer:
354Mixing device with reduction gear system
3553-phase Electrically driven motor:
3560.5 HP
3570.75 HP
3581.0 HP
359Foundation \ Base plate
360Starter along with necessary wiring upto motor
361Providing, fitting, testing and commissioning of following itemn for Alum Dosing Unit-
362Mixing device with reduction gear system.
3633-phase electrically driven motors:
3640.5 HP
3650.75 HP
3661.0 HP
367Foundation / Base plate
368Starter along with necessary wiring upto motor
369P.V.C outlet, overflow system with fittings upto point of application
370150mmdiadrain out let
37150 mm dia Service water piping.
372Constant dozing unit with time device
373Manually operated hoist
374Providing, fitting, testing and commissioning of following itemns forChlorine Dosing Unit-
375Mixing device with reduction gear system.
3763-phase electrically driven motors:
3770.5 HP
3780.75 HP
3791.0 HP
380Foundation / Base plate.
381P.V.C outlet, overflow system with fittings upto point of application.
382Starter along with necessary wiring upto motor
383150 mm dia Drain out let
38450mm dia service water piping
385Constant dozing unit with time device.
386Providing and fixing D.I. sluice valves Class 1 (with cap) complete with rubber insertions, bolts, nuts, extention rod, joint connector, supporting pedestal with base plate, top plate and necessary anchoring boltsetc. (the tail pieces if required will be paid separately). Confirming to IS:14846 read with latest amendments.
38780 mm dia.
388100 mm dia.
389125 mm dia.
390150 mm dia.
391200 mm dia.
392250 mm dia.
393300 mm dia.
394350 mm dia.
395Air Scouring Arrangements
396Providing fitting, testing and comissioning ofair blower standard make ISI mark capable of providing compression @ 0.35 kgs/sqcm coupled with suitable 3 phase induction electric motorcomplete with auxiliary pipe system upto filter beds with pressure guage, Nozzles, foundation block, base plate, air check valve , non- return valve, Starter etc
3972.10 KLPM Air blower with 2.0 HP Motor.
3984.2 KLPM Air blower with 5.0 HP Motor.
3998.2 KLPM Air blower with 7.5 HP Motor.
40010.6 KLPM Air blower with 10.0 HP Motor.
40112.3 KLPM Air blower with 12.50 HP Motor.
40216.80 KLPM Air blower with 15.0 HP Motor.
403Up Wash Arrangements
404Supply installation and successful testing and commissioning of mono block pumping unit standard make ISI mark coupled with 2 phase induction motor with appropriate pumping capacity so as to fill the tank within the max. of 2 hours with nominal dynamic head of 25m along with all accessories like foot valves, non- return valves, foundation block, base plate, suction pipe, suitable rising main with nominal dia 50mm (class-B)with heavey dutyvalves and other accessories required for the job.
405Pumping unit with 5.0 HP Motor.
406Pumping unit with 7.5 HP Motor.
407Pumping unit with 12.5 HP Motor.
408Pumping unit with 15.0 HP Motor.
409P/F testing and commissioning of MS Rotating Desludging Bridge comprising of following items:
410Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete for the Installation Testing and Commissioning of Half Bridge with Central Drive mechanism, scrapper and churners for required dia Clarifer.
411Riveted and bolted
412Welded
413Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete
414On steel work
415On concrete work
416Central axle turn table with double bearing and guide for incoming cable.
417Peripheral drive assembly with following motors, gear box, rollers, drive trolly (60:1 reduction gear box).
418Pumping unit with 2.0 HP Motor.
419Pumping unit with 5.0 HP Motor.
420Pumping unit with 7.5 HP Motor.
421Starter along with necessary wiring upto motor
422Flocculator drive assembly with crown wheel, pinion sets, reduction gear (40:1) with motors complete job.
4230.5 HP
4240.75 HP
4251.0 HP
426Incoming cable, telescopic electric pole with rotary current collector
427Providing and laying/fixing S&S Centrifugally Cast (Spun)/ Ductile Iron Pipes Class K-7 conforming to IS : 8328
428100 mm dia
429150 mm dia
430200 mm dia
431250 mm dia
432300 mm dia
433350 mm dia
434400 mm dia
435450 mm dia
436Providing and laying D.I. standard specials such as tees, bends, collars, tapers, caps etc. suitable for flanged jointing as per IS : 9523 (as per site requirement)
437Up to 300 mm dia.
438Over 300 mm dia.
439Providing/ Fixing, installation, successful commissioning of double flanged MS pipes/specials to be fabricated from MS tube heavy quality nominal thickness 6mm, conforming to relevant Indian Standard IS-1239 and/or IS 1161 read with up to date amendments. The pipe material should be of standard quality and must withstand all the anticipated design pressure ratings.The work should be leakproof and should be painted with anti corrosive red oxide primer. Complete Job.

AI Tender Summary

OUR REF NO 31441214
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-03-2022
Authority
Authority Name Public Health Engineering Department
Work Description Const And Successful Testing And Commissioning Of 0.10 Mgd Rfsp ( Cost Shall Include , Clari-Floculator, Flash Mixer, Filter House . Wash Water Disposal Chamber ) At Amad Zoo.Wss. Wagad Const And Successful Testing And Commissioning Of 0.10 Mgd Rfsp ( Cost Shall Include , Clari-Floculator, Flash Mixer, Filter House . Wash Water Disposal Chamber ) At Amad Zoo.Wss. Wagad
Basic Detail
Tender No e-NIT No.132 of 2021-22 Dated-08-03-2022
Bidding Type Tender
Location
City bijbehara
State Jammu And Kashmir
Key Dates
Publish Date 12 Mar 2022
Submission Date 31 Mar 2022
Open Date 02 Apr 2022
Finance
Tender Value Ref. Documents
Tender Fee 1000
EMD 50000
Exemption Not Available
Document List
5b4ccbcc-83d9-4913-beba-11e164418fd5.html
BOQ_379524.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 12, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 31, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 02, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5b4ccbcc-83d9-4913-beba-11e164418fd5.html

xls

BOQ_379524.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders