Purchase Instrument Snmmc Dhanbad Purchase Instrument Snmmc Dhanbad , Laying And Jointing Pvc Pipe. Heading , Microscope Monocular ( With Led Rechargeable Option ) , Microscope Binocular ( Led / Lcd With Rechargeable Option ) , Fully Automated M, Dhanbad-Jharkhand

Patliputra Medical College has published Purchase Instrument Snmmc Dhanbad Purchase Instrument Snmmc Dhanbad , Laying And Jointing Pvc Pipe. Heading , Microscope Monocular ( With Led Rechargeable Option ) , Microscope Binocular ( Led / Lcd With Rechargeable Option ) , Fully Automated M. Submission Date for this Tender is 22-03-2022. Bottles Tenders in Dhanbad Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31419331
Corrigendum : Purchase Instrument Snmmc Dhanbad Purchase Instrument Snmmc Dhanbad , Laying And Jointing Pvc Pipe. Heading , Microscope Monocular ( With Led Rechargeable Option ) , Microscope Binocular ( Led / Lcd With Rechargeable Option ) , Fully Automated M
Open Tender
Indian
Jharkhand
Dhanbad
22-03-2022

Tender Details

Purchase Instrument Snmmc Dhanbad Purchase Instrument Snmmc Dhanbad , Laying And Jointing Pvc Pipe. Heading , Microscope Monocular ( With Led Rechargeable Option ) , Microscope Binocular ( Led / Lcd With Rechargeable Option ) , Fully Automated Microstrip Processorit Should Be A Fully Automated Elisa System Capable Of Dispensing Sample , Reagents, Incubation, Shaking, Washing, Reading In Microwells. It Should Be Operated By External Pc. Able Toperform 6 Or More Tests With Same Or Different Protocols In The Same Batch. Able To Do Qualitative, Semi Quantitative And Quantitative Elisa. It Should Use Different Plate Geometrics In Flat, U And V Bottom. Optionalexternal Barcode Reader For Samples. Quantitative Tests Should Support Different Calibration Curve Such As Point-To-Point, Linear Regression, Polynomial Regression, Cubic Spline, Logit-Log, Lin-Log. Take Max. 10 Calibrators / Standardsper Test In Quantitative Assay. It Should Reader Wavelength Range 400-800 Nm. Four Filters 405Nm, 450 Nm, 492 Nm And 630 Nm. It Should Be A Shaker Facility. Washer 8 Channel Manifold. Washer Adjustment To Different Plate Geometrics Should Be Possible. Residual Volume And Should Not Be More Than 12 Microliters. Facility For 3 Wash Buffer Bottles Of 1 L With Level Sensors And 1 Rinse And 1 Waste Bottle. Perform Maintenance Procedures Such As Wash ( Auto Wash, Probe Wash ) , Prime, Strip Cleaning. The Incubator Should Be Rt Or 37 Deg. Temperature. The System Should Hold 30 Nos. 8 Well Breakable Elisa Strips Without Plate Frames, Equivalent To 2 ½ Plate System. It Should Take Maximum 58 To 60 Samples / Batch, And 35 To 37 Samples For Most Optimum Performance. A Reagent Cum Sample Tray And Should Hold Sample, Reagents And Disposable Tips. Total Number Of Reagents Possible On The Tray Should Be 24 Nos. Maximum 30 Positions For Calibrators / Standards / Controls Should Be Provided. Maximum 200 To 205 Disposable Carbonated Tips Should Be Possible To Be Loaded On The Tray. Sample And Reagent Dispensing With Fixed And Carbonated Tips. It Should Be User Programmable. Reagent Locations For Bottles And Test Tubes With Adapters. Should Be Qc Reports Generated Using Lj Chart / Cv Evolution / O.D Evolution / Conc. Evolution & Westgard Rules. There Should Be Provision For Demonstration Of Equipment Before Final Purchase If Required. Should Be 1Kva Online Ups With Battery Backup 45Minutes, Complete Pc Set, All Accessoriesand Start Up Reagents. Ups And Battery Warranty Must Be Written On Affidavit. Brochure Should Be Attached. , Automated System For Blood Culture With Identification And Antibiotic Susceptibility Fully Automated Modular System Capable Of Culture Of Blood And Body Fluids For Bacteria, Mycobacterium, Yeast Etc. Capacity = 120 Bottle Positions & Modular System ( Including Blood Culture & Tb Culture ) Should Be A Non Radiometric Assay System. System Should Have Specific Algorithms For Detection Of Growing Micro Organisms And Should Be Capable Of Continuous Monitoring Of All Samples For Growth Of Micro Organisms. Every Cell ( Bottle Position ) Should Have Its Own Optics And Detection Device. System Should Be Capable Of Analyzing Delayed Entry Specimens Along With Routinesamples In Case Of Blood Culture System Should Be Having Continuous Agitation And Incubation Facility To Provide Optimal Growth Of Microorganisms. The Bottled Media Should Be Capable Of Neutralizing The Effect Of Antibiotic.The Culture Bottles Should Be Made Of Plastic. System Should Be Capable Of Processing Both Adult And Paediatric Samples. The System Should Be Capable Of Culture For Mycobacterium From Respiratory, Non Respiratory & Blood Specimens.System Should Have Interface For Lab Information System.The System Should Be Supplemented With Automated Bacterial Identification And Antibiotic Susceptibility Testing System For All Types Bacteria ( Aerobes & Anaerobes ) Yeast Etc. The System Should Be Totally Automated For Sample Standardization, Loading, Incubating And Reading The Results. It Should Be Used For Identification And Antimicrobial Susceptibility Of Clinically Significant Bacteria And Yeast ( Id / Ast ) .Analytical Parameters: Identification Up To Species Level, Direct Growth Based ( Up To Mic Level ) Testing Base: Should Be On Disposable Sealed Bar Coded Card / Panel ( Ready To Use ) With Pre Filled Reagents. There Should Be No Need To Add Any Additional Reagents After Incubation Type Of Panels: It Should Have Different Panels ( Id & Ast Separately ) To Save Cost. Should Make Use Of Non-Radiometric Measurements With No Manual Intervention. Panels For: Id & Ast Of Gram Negative, Gram Positive And Yeast. Id Panels For Anaerobes, Esbl Confirmation, Mrsa Confirmation, Neisseria & Haemophilus.Panel Capacity: The System Should Have Capacity Of Processing More Than 50 Samples At A Time. Expert System: The Software Should Have An Expert System Permitting Appropriateintervention For Organisms With Unusual Resistance Pattern. Sample Dispensing: System Should Not Require Any Manual Dispensing Of Inoculum To Avoid Human Error, It Should Be Done Automatically. Additional Reagents: System To Be Compatible With Cost Effective Test Cards To Avoid Any Extra Costs Of Additional Reagents.Incubator: On Board Incubation Chamber. Testing Time: Ideally Be On The Same Day ( Between 5 -10 Hrs ) , Which Reduces Time To Result. Printer: External Printer For Direct Report Print Outs. Bar Code: The System Should Have Bar Code Scanning Facility To Identify Each Panel Type. Software: Should Be Windows Based, User Friendly With Touch Screen Key Pad. The Data From The System Should Be Automatically Transferred To The Host Computer Where Data Processing Can Be Done And Reports Can Be Generated.The Software Should Identify And Interpret Results As Per Nccls Guidelines Source Of Supply- Indigenous / Imported. There Should Be Provision For Demonstration Of Equipment Before Final Purchase If Required. Training Has To Be Given To Department Personnel For The Instrument. Supplier Must Ensure Local Servicing Agent And Continuous Supply Of Consumables. Should Be 2Kva Online Ups With Battery Backup 30Minutes, Complete Pc Set, All Accessoriesand Start Up Reagents. Ups And Battery Warranty Must Be Written On Affidavit. Brochure Should Be Attached , Amc % , Cmc %

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Mar-2022 Date Change In Tender Date 22-03-2022

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work: Supply of equipments/instruments for Department of Microbiology
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
2Microscope Monocular (with LED rechargeable option)
3Microscope Binocular ( LED/ LCD with rechargeable option)
4Fully Automated Microstrip ProcessorIt should be a Fully Automated ELISA System capable of dispensing sample , reagents, incubation, shaking, washing, reading in microwells. It should be operated by external PC. Able toperform 6 or more tests with same or different protocols in the same batch. Able to do qualitative, semi quantitative and quantitative Elisa. It should use different plate geometrics in Flat, U and V bottom. optionalexternal barcode reader for samples. Quantitative tests should support different calibration curve such as Point-to-Point, Linear Regression, Polynomial Regression, Cubic Spline, Logit-log, Lin-Log. Take max. 10 calibrators / standardsper test in quantitative assay. It should Reader wavelength range 400-800 nm. Four filters 405nm, 450 nm, 492 nm and 630 nm. It should be a shaker facility. Washer 8 channel manifold. Washer adjustment to different plate geometrics should be possible. Residual volume and should not be more than 12 microliters. Facility for 3 wash buffer bottles of 1 L with level sensors and 1 rinse and 1 waste bottle. Perform maintenance procedures such as Wash (Auto Wash, Probe Wash ), Prime, Strip cleaning. The incubator should be RT or 37 Deg. Temperature. The system should hold 30 nos. 8 well breakable ELISA strips without plate frames, equivalent to 2 ½ Plate system. It should take maximum 58 to 60 samples / batch, and 35 to 37 samples for most optimum performance. A reagent cum sample tray and should hold sample, reagents and disposable tips. Total number of reagents possible on the tray should be 24 nos. Maximum 30 positions for calibrators/ standards/ controls should be provided. Maximum 200 to 205 disposable carbonated tips should be possible to be loaded on the tray. Sample and reagent dispensing with fixed and carbonated tips. It should be user programmable. Reagent locations for bottles and test tubes with adapters. Should be QC reports generated using LJ Chart / CV Evolution / O.D Evolution / Conc. Evolution & Westgard Rules. There should be provision for demonstration of equipment before final purchase if required. Should be 1KVA online UPS with battery backup 45minutes, Complete PC set,All accessoriesand start up reagents. UPS and Battery warranty must be written on Affidavit. Brochure should be attached.
5Automated System for Blood Culture with identification and antibiotic susceptibility Fully automated modular System capable of culture of blood and body fluids for bacteria, mycobacterium, yeast etc. Capacity = 120 bottle positions & modular system (including blood culture & TB culture) Should be a non radiometric assay system. System should have specific algorithms for detection of growing micro organisms and should be capable of continuous monitoring of all samples for growth of micro organisms. Every cell (bottle position) should have its own optics and detection device. System should be capable of analyzing delayed entry specimens along with routinesamples in case of blood culture System should be having continuous agitation and incubation facility to provide optimal growth of microorganisms. The bottled media should be capable of neutralizing the effect of antibiotic.The culture bottles should be made of plastic. System should be capable of processing both adult and paediatric samples. The system should be capable of culture for mycobacterium from respiratory, non respiratory & blood specimens.System should have interface for lab information system.The system should be supplemented with automated bacterial identification and antibiotic susceptibility testing system for all types bacteria ( aerobes & anaerobes ) yeast etc. The system should be totally automated for sample standardization, loading, incubating and reading the results. It should be used for identification and antimicrobial susceptibility of clinically significant bacteria and yeast (ID / AST).Analytical parameters: Identification up to species level, Direct growth based (up to MIC level)Testing base: Should be on disposable sealed bar coded card / panel (ready to use) with pre filled reagents. There should be no need to add any additional reagents after incubation Type of panels: It should have different panels (ID & AST separately) to save cost. Should make use of non-radiometric measurements with no manual intervention. Panels for: ID & AST of Gram negative, Gram positive and Yeast. ID panels for Anaerobes, ESBL confirmation, MRSA Confirmation, Neisseria & Haemophilus.Panel capacity: The system should have capacity of processing more than 50 samples at a time. Expert System: The software should have an expert system permitting appropriateintervention for organisms with unusual resistance pattern. Sample dispensing: System should not require any manual dispensing of Inoculum to avoid human error, it should be done automatically. Additional reagents: System to be compatible with cost effective test cards to avoid any extra costs of additional reagents.Incubator: On board incubation chamber. Testing time: Ideally be on the same day (between 5 -10 hrs), which reduces time to result. Printer: External printer for direct report print outs. Bar Code: The system should have bar code scanning facility to identify each panel type. Software: Should be Windows based, user friendly with touch screen key pad. The data from the system should be automatically transferred to the host computer where data processing can be done and reports can be generated.The software should identify and interpret results as per NCCLS guidelines Source of supply- Indigenous/Imported. There should be provision for demonstration of equipment before final purchase if required. Training has to be given to department personnel for the instrument. Supplier must ensure local servicing agent and continuous supply of consumables. Should be 2KVA online UPS with battery backup 30minutes, Complete PC set,All accessoriesand start up reagents. UPS and Battery warranty must be written on Affidavit. Brochure should be attached
6AMC %
7CMC %
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail