}

Nhp Providing 30 Kva Servo Voltage Stabilizer And Electrical Wiring In District Water Testing Lab Dhalli Shimla-12 Himachal Pradesh. , Wiring For Light Point/Fan Point/Exhaust Fan /Call Bell Point With 1.5 Sq. Mm. Pvc Insulated Heat Resistant Flame Retard, Shimla-Himachal Pradesh

Irrigation And Public Health Department has published Nhp Providing 30 Kva Servo Voltage Stabilizer And Electrical Wiring In District Water Testing Lab Dhalli Shimla-12 Himachal Pradesh. , Wiring For Light Point/Fan Point/Exhaust Fan /Call Bell Point With 1.5 Sq. Mm. Pvc Insulated Heat Resistant Flame Retard. Submission Date for this Tender is 24-03-2022. Coats and Jackets Tenders in Shimla Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31417354
Nhp Providing 30 Kva Servo Voltage Stabilizer And Electrical Wiring In District Water Testing Lab Dhalli Shimla-12 Himachal Pradesh. , Wiring For Light Point/Fan Point/Exhaust Fan /Call Bell Point With 1.5 Sq. Mm. Pvc Insulated Heat Resistant Flame Retard
Open Tender
Indian
Himachal Pradesh
Shimla
24-03-2022

Tender Details

Nhp Providing 30 Kva Servo Voltage Stabilizer And Electrical Wiring In District Water Testing Lab Dhalli Shimla-12 Himachal Pradesh. , Wiring For Light Point/Fan Point/Exhaust Fan /Call Bell Point With 1.5 Sq. Mm. Pvc Insulated Heat Resistant Flame Retardant (Hrfr) And Low Smoke Single Core (Flexile) Copper Conductor Cable In Surface/Recessed Pvc Conduit And Earthing The Light Point With 1.5 Sq. Mm. Hrfrls/Pvc Insulated Single Core Copper Conductor Cable As Required. , Group C , Supplying And Fixing Metal Box Of 100Mmx100mmx60mm Deep (Nominal Size ) On Surface/Recess With Suitable Size Phenolic Laminated Sheet Cover In The Front Including Providing And Fixing 5 Pin 5/6 Amps Socket Outlet And 5/6 Amps, Paino Type Switch, Connections, Painting Etc. As Required. , Supplying And Fixing Metal Box Of 180Mmx100mmx60mm Deep(Nominal Size) On Surface/Recess With Suitable Size Phenolic Laminated Sheet Cover In The Front Including Providing And Fixing 6 Pin 15/16 Amps Socket Outlet And 15/16 Amps, Paino Type Switch, Connection Painting Etc. As Required. , S/G Led T5 Tubelight22 Watt In Aluminium Housing Of Syska Or Its Equivalent Approved Make Of Complete With Connections Etc As Requiredcapable In All Respects. , S/F Led Surface Downligtsquare/Round Of Syska Or Its Equivalent Approved Make Of Following Wattage Complete With Connections Etc As Required Capable In All Respects. , Led Surface Downlight 12 Watt , Led Surface Downlight 30 Watt , S/F Led Bulk Head 9 Watt (6500K) Of Syska Or Its Equivalent , S/F Led Street Light 150 Watt In Of Syska Of Syska Or Its Equivalent Approved Make Of Complete With Connections Etc As Required Capable In All Respects. , Wiring For Light Plug With 2X1.5Sq Mm. Pvc Insulated Heat Resistant Flame Retardant (Hrfr) And Low Smoke Single Core (Flexible) Copper Conductor Cable In Surface/Recessed Pvc Conduit Along With 1 No. 1.5 Sq Mm. Hrfrls/Pvc Insulated Single Core Copper Conductor Cable For Earthing As Required. , Wiring For Power Plug With 2X4 Sq. Mm. Pvc Insulated Heat Resistant Flame Retardant (Hrfr) And Low Smoke Single Core (Flexible) Copper Conductor Cable In Surface/Recessed Pvc Conduit Along With 1 No. 4 Sq . Mm Hrfrls/Pvc Insulated Single Core Copper Conductor Cable For Earthing As Required , Wiring For Power Plug With 4X4 Sq. Mm. Pvc Insulated Heat Resistant Flame Retardant (Hrfr) And Low Smoke Single Core (Flexible) Copper Conductor Cable In Surface/Recessed Pvc Conduit Along With 2 No. 4 Sq . Mm Hrfrls/Pvc Insulated Single Core Copper Conductor Cable For Earthing As Required , Supplying And Fixing Of Following Way Segregated, Triple Pole And Neutral, Ip-43 Double Sheet Stleel Mcb Distributionboard 415 Volts On Surface/Reces, With Provision To Mount 4 Module Mccb Incomer, 4 Module Sub-Incomer In Each Phase Andsp Mcbs As Outgoing, Complete With Tinned Copper Bus-Bar, Wire –Set , Neutral Link, Earth Bar, Din-Bar, Detachable Gland Plate, Cable, Identification Labels Interconnections, Phosphatized And Powder Painted , Including Earthing Etc As Required Make :L&T, Schneider , Siemens , Abb, Legrand, C&S Etc , 8Way , Providing And Fixing Following Rating And Breaking Capacity Mccb In The Existing Cubical Panel Board Including Drilling Holes In The Cubicle Panel, Making Connections, Etc. As Required. , 125Amp , Supplying And Erection Of 6Amps To 32 Amps, Rating . 10Ka Breaking Capacity , 240 Volts ‘C’ Curves Miniature Circuit Breaker Of Following Poles In The Existing Mcb Db Complete With Connections Etc. As Required:- , Single Pole Cat-A , Supplying And Erection Of 40/50/63/Amps , 10 Ka Breaking Capacity, 240 Volts, ‘C’ Curves, Miniature Circuit Breaker Of Following Poles In The Existing Mcb Db Complete With Connections Etc. As Require:- , Double Pole Cat-A , Supplying And Fixing Following Rating, Double Pole (Single Phase & Neutral) 240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Up To 300 Miliampers In The Existingmcb Db Compete With Connections, Testing And Commissioning Etc . As Require. , 63Amps. Cat-A , Servo Voltage Stablizer 30 Kva With Input Range 300-480 V Ac & Output 415 With 1% , 3 Phase With Lcd Display For Metering With Audible Alarm With Overall Efficiency Upto 97% And Standard Conformance To Is 9815,Is 1248 , Is 2026/Iec60076 And With Ip20 Protection With Additional Bypass Arrangents. , Wiring For Circuit/ Sub-Main With 4X10 Sq. Mm Pvc Insulated Heat Resistant Flame Retardant (Hrfr) And Low Smoke Single Core (Flexible) Copper Conductor Cable In Surface/Recessed Pvc Conduit Along With 2 No. 10 Sq Mm (4X10+2X10) Hrfrls/Pvc Insulated Single Core Copper Conductor Cable For Earthing As Required. , Sitc Of Phase Corrector Wall Mounted Panel Complete With Mccb 100 3 Pole With O/L & S/C Protection Spredaer Link 110Amp Tp Contractor Coil Control Mcb Phase Corrector Relay On Delay Timer Made Out Of 16 Swg Ms Crc Sheet Duly Painted Having Tpn 100 Amp Busbar Complete With Connections Etc Required Complete In All Respects

Key Value

Document Fees
Refer document
EMD
INR 10000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Providing 30 KVA servo Voltage stabilizer and wiring in water testing lab at Dhali shimla-12
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexile) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 sq. mm. HRFRLS/PVC insulated single core copper conductor cable as required.
2Group C
3Supplying and fixing metal box of 100mmX100mmX60mm deep (nominal size ) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps, paino type switch, connections, painting etc. as required.
4Supplying and fixing metal box of 180mmX100mmX60mm deep(nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps, paino type switch, connection painting etc. as required.
5S/G led T5 Tubelight22 Watt in aluminium housing of syska or its equivalent approved make of complete with connections etc as requiredcapable in all respects.
6S/F Led surface downligtsquare/round of syska or its equivalent approved make of following wattage complete with connections etc as required capable in all respects.
7Led surface Downlight 12 watt
8Led surface Downlight 30 watt
9S/F Led Bulk head 9 watt (6500k) of syska or its equivalent
10S/F led street light 150 watt in of syska of syska or its equivalent approved make of complete with connections etc as required capable in all respects.
11Wiring for light plug with 2x1.5Sq mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5 Sq mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
12Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 Sq . mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required
13Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No. 4 Sq . mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required
14Supplying and fixing of following way SEGREGATED, triple pole and neutral, IP-43 double sheet stleel MCB distributionboard 415 volts on surface/reces, with provision to mount 4 module MCCB incomer, 4 module sub-incomer in each phase andSP MCBs as outgoing, complete with tinned copper bus-bar, wire –set , neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted , including earthing etc as required Make :L&T, Schneider , Siemens , ABB, Legrand, C&S etc
158Way
16Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.
17125Amp
18Supplying and erection of 6amps to 32 amps, rating . 10KA breaking capacity , 240 volts ‘C’ curves miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
19Single pole Cat-A
20Supplying and erection of 40/50/63/amps , 10 KA breaking capacity, 240 volts, ‘C’ curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as require:-
21Double pole Cat-A
22Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existingMCB DB compete with connections, testing and commissioning etc . as require.
2363Amps. Cat-A
24Servo Voltage Stablizer 30 Kva with input range 300-480 v AC & output 415 with 1% , 3 phase with LCD display for metering with audible alarm with overall efficiency upto 97% and standard conformance to IS 9815,IS 1248 , IS 2026/IEC60076 and with IP20 protection with additional bypass arrangents.
25Wiring for circuit/ sub-main with 4x10 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (Flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No. 10 Sq mm (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
26SITC of phase corrector wall mounted panel complete with MCCB 100 3 pole with O/L & S/C protection spredaer link 110Amp Tp contractor coil control mcb phase corrector relay on delay timer made out of 16 SWG MS CRC sheet duly painted having TPn 100 amp Busbar complete with connections etc required complete in all respects
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail