Improvement, Development And Replacement Of Distribution Panels At Various Sdmc Schools In Dhoolsiras, Rangpuri Boys , Rangpuri Girls, Mahipalpur Boys Bharthal Boys Under Ngz Improvement, Development And Replacement Of Distribution Panels At Var
Tender Overview
Project Description
Improvement, Development And Replacement Of Distribution Panels At Various Sdmc Schools In Dhoolsiras, Rangpuri Boys , Rangpuri Girls, Mahipalpur Boys Bharthal Boys Under Ngz Improvement, Development And Replacement Of Distribution Panels At Various Sdmc Schools In Dhoolsiras, Rangpuri Boys , Rangpuri Girls, Mahipalpur Boys Bharthal Boys Under Ngz
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB |
| 2 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A, 36kA, FPMCCB |
| 3 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250A, 50kA, FPMCCB |
| 4 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 6 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt as required.) |
| 7 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 8 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm |
| 12 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 13 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 14 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 15 | Supply of 4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 16 | Supply of 6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 17 | Supply of 10 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 18 | Supply of 16 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable. |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 20 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm. |
| 21 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). |
| 22 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 23 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1 kV grade conforming to IS-7098 of 4 core 16 sqmm |
| 24 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1 kV grade conforming to IS-7098 of 4 core 25 sqmm |
| 25 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1 kV grade conforming to IS-7098 of 4 core 50 sqmm |
| 26 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1 kV grade conforming to IS-7098 of 2 core 10 sqmm |
| 27 | Supply, Installation, testing and commissioning of powder distribution board made out of 1.6 mm sheet steel, epoxy powder coated, specially designed Al bus bar 400 A to 630 A with heat shinkable colour coded sleeves suitable for accomodating MCCBs /MCBs /Isolators as incoming and outgoing as required without (MCCBs/MCBs/Isolators) complete with digital meter Module, including Voltmeter, Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required (conforms to IS:8623) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender