Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #31374087

Nit No. 20(21-22)/Cwa(Wns)Ii Hp/Item No. 02 Procurement Of Double Beam Uv-Visible Spectrophotometer With Pc Compatibility And Software For Different Wtp/Stp Laboratories Under Cwa (Wns)-Ii Division. , Double Beam Uv-Visible Spectrophotometer With Pc Compa

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Mar 2022
0 days left
EMD
49600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Nit No. 20(21-22)/Cwa(Wns)Ii Hp/Item No. 02 Procurement Of Double Beam Uv-Visible Spectrophotometer With Pc Compatibility And Software For Different Wtp/Stp Laboratories Under Cwa (Wns)-Ii Division. , Double Beam Uv-Visible Spectrophotometer With Pc Compatibility And Software. (Make : Hach, Thermo Scientific, Agilent, Perkin Elmer, Wtw) Specification For Uv-Visible Range Spectrophotometer Equipment Type : Bench Top Analysis : Water/Waste Water Principle : Photometry The Spectrophotometer Will Be Dual Beam (Viz. Uv-Visible) Operation And With The Reference Cell Position For Kinetics Application. It Will Be Mandatorily Have An 8-Cell Carousel. The Spectrophotometer Must Have Room-Light Resistance, Allowing Lid-Open Operation For Improved Speed And Convenience. The Spectrophotometer Will Have Of Automated Cell Changers And Cell Holders, Sipper And Fibre Optics Probes For Measurements Outside Of The Sample Compartment. It Must Accommodate High Throughput Measurements And Temperature Control. The Spectrophotometer Will Have Following Features: 1. Spectrophotometer Will Be Double Beam (Uv-Visible)/Reference Cell. 2. It Will Have High Resolution Touch Screen User Interface. The Spectrophotometer Must Be Capable Of Operating Through Computer Also. 3. There Will Be 8-Position Cell Changer With Switchable Turret. 4. It Will Have Onboard Methods, Reporting And Data Export. 5. It Will Be Networking Capable And Will Have Wifi-Adaptor. 6. It Is Capable Of Open Lid Operation. 7. There Will Be Room Light Resistance. 8. It Will Have Sipper (Optional). 9. It Must Accommodate Cells Upto 100 Mm Path Length. 10.There Shall Be 8-Position Cell Changer With Switchable Turret. 11. It Must Have Optional Facility For 4-Position Cell Changer (Long Path Cells) And Peltier-Thermostat Single Holder (200 Degree C-60 Degree C). Detector Type : Dual Silicon Photodiodes Display : 7-Inch Colour Touch Screen, High Definition, 800 X 1280 Pixels Photometric : ±0.002 A At 0.5 A Accuracy Instrument : ±0.004 A At 1.0 A : ±0.008 A At 2.0 A Wavelength Accuracy : ±0.5 Nm Baseline Flatness : ±0.002A Compartments : 8-Position Cell Changer (Standard) Also Accommodate (Optional):Peltier Thermostat Cell Holder (20-60 Degree Celsius) Sipper Accessory (Optional) Drift : (At 500 Nm After 1 Hour Warm-Up) <0.0005A/Hr Electricalrequirements : External Ac To Dc Converter, Voltage And Frequency (Hz) Selected Automatically, 100-240 Volts, 50-60 Hz Keypad : Touch Screen Lamp: Xenon Flash Lamp (>5 Years Typical, 3 Years Guaranteed) Noise : (Rms At 500 Nm 60 Consecutive Measurements) =0.00020A At 0A At 260 And 500 Nm = 0.00030A At 1A At 260 And 500 Nm =0.00040A At 2A At 260 And 500 Nm Optical Design: Double Beam Photometric Display : -3A To + 5A Photometric Range : -2A To +3.5A Photometric Repeatability ±0.001A At 1 A Measured At 1.0A At 546 Nm Spectral Bandwidth :2 Nm Stray Light < 1.0 % T 198 Nm (Kcl), <0.05% T At 220 Nm (Nacl), <0.03 % T At 340Nm (Nano2) Wavelength Data Interval : 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm Wavelength Range : 190 Nm – 1100 Nm Wavelength Repeatability : < ± 0.2 Nm Wavelength Scan Speed: Slow, Medium And Fast Up To 1600 Nm/Min Printer:Capable To Connect With Printer Computer Operation : The Spectrophotometer Can Be Operated From Compatible Computer And Software. Computer And Operational Software To Run Spectrophotometer Will Be A Part Of The Spectrophotometer. Connections: Single Usb-A Supports Flash Memory Devices For Method And Data Storage Duplex Usb-A On Side Supports Connection To A Computer Running Optional Remote Control Software, Keyboard, Mouse Export Data To Network Or Pc Via Usb, Ethernet, Or Wi-Fi Usb Adaptor, Available Print Via Usb, Ethernet Or Wi-Fi Usb Adaptor Available Warranty : 3 Years

BOQ

Name of Work: Procurement of Double Beam UV-Visible Spectrophotometer with PC compatibility and software for differentWTP / STP Laboratories under CWA (W&S)-II division.
Sl. No. Item Description
1Double Beam UV-Visible Spectrophotometer with PC compatibility and software.(Make : Hach, Thermo Scientific, Agilent, Perkin Elmer, WTW)Specification for UV-Visible Range SpectrophotometerEquipment Type : Bench TopAnalysis : Water/Waste WaterPrinciple : PhotometryThe spectrophotometer will be dual beam (viz. UV-Visible) operation and with the reference cell position for Kinetics application. It will be mandatorily have an 8-cell carousel. The spectrophotometer must have room-light resistance, allowing lid-open operation for improved speed and convenience.The spectrophotometer will have of automated cell changers and cell holders, sipper and fibre optics probes for measurements outside of the sample compartment. It must accommodate high throughput measurements and temperature control.The spectrophotometer will have following features:1. Spectrophotometer will be double beam (UV-visible)/reference cell.2. It will have high resolution touch screen user interface. The spectrophotometer must be capable of operating through computer also.3. There will be 8-position cell changer with switchable turret.4. It will have onboard methods, reporting and data export.5. It will be networking capable and will have wifi-adaptor.6. It is capable of open lid operation.7. There will be room light resistance.8. It will have sipper (optional).9. It must accommodate cells upto 100 mm path length.10.There shall be 8-position cell changer with switchable turret.11. It must have optional facility for 4-position cell changer (long path cells) and Peltier-thermostat single holder (200 degree C-60 degree C).Detector Type : Dual Silicon PhotodiodesDisplay : 7-inch colour touch screen, high definition, 800 x 1280 pixelsPhotometric : ±0.002 A at 0.5 AAccuracy instrument : ±0.004 A at 1.0 A: ±0.008 A at 2.0 AWavelength Accuracy : ±0.5 nmBaseline Flatness : ±0.002ACompartments : 8-position cell changer (standard)Also accommodate (optional):Peltier thermostat cell holder (20-60 degree Celsius)Sipper accessory (OPTIONAL)Drift : (At 500 nm after 1 hour warm-up) <0.0005A/HrElectricalRequirements : External AC to DC converter, Voltage and frequency (Hz) selected automatically, 100-240 volts, 50-60 HzKeypad : Touch screenLamp: xenon Flash Lamp (>5 years typical, 3 years guaranteed)Noise : (RMS at 500 nm 60 consecutive measurements)\"=0.00020A at 0A at 260 and 500 nm = 0.00030A at 1A at 260 and 500 nm =0.00040A at 2A at 260 and 500 nm\"Optical Design: Double BeamPhotometric Display : -3A to + 5APhotometric Range : -2A to +3.5APhotometric Repeatability ±0.001A at 1 A measured at 1.0A at 546 nmSpectral Bandwidth :2 nmStray Light < 1.0 % T 198 nm (KCl), <0.05% T at 220 nm (NaCl), <0.03 % T at 340nm (NaNO2)Wavelength Data Interval : 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm Wavelength Range : 190 nm – 1100 nmWavelength Repeatability : < ± 0.2 nmWavelength Scan Speed: slow, medium and fast up to 1600 nm/minPrinter:Capable to connect with printerComputer Operation : the spectrophotometer can be operated from compatible computer and software. Computer and operational software to run spectrophotometer will be a part of the spectrophotometer.\"Connections: Single USB-A supports flash memory devices for method and data storage\"Duplex USB-A on side supports connection to a computer running optional remote control software, keyboard, mouseExport data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, availablePrint via USB, Ethernet or Wi-Fi USB adaptor availableWarranty : 3 years

AI Tender Summary

OUR REF NO 31374087
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 14-03-2022
Authority
Authority Name Delhi Jal Board
Work Description Nit No. 20(21-22)/Cwa(Wns)Ii Hp/Item No. 02 Procurement Of Double Beam Uv-Visible Spectrophotometer With Pc Compatibility And Software For Different Wtp/Stp Laboratories Under Cwa (Wns)-Ii Division. , Double Beam Uv-Visible Spectrophotometer With Pc Compatibility And Software. (Make : Hach, Thermo Scientific, Agilent, Perkin Elmer, Wtw) Specification For Uv-Visible Range Spectrophotometer Equipment Type : Bench Top Analysis : Water/Waste Water Principle : Photometry The Spectrophotometer Will Be Dual Beam (Viz. Uv-Visible) Operation And With The Reference Cell Position For Kinetics Application. It Will Be Mandatorily Have An 8-Cell Carousel. The Spectrophotometer Must Have Room-Light Resistance, Allowing Lid-Open Operation For Improved Speed And Convenience. The Spectrophotometer Will Have Of Automated Cell Changers And Cell Holders, Sipper And Fibre Optics Probes For Measurements Outside Of The Sample Compartment. It Must Accommodate High Throughput Measurements And Temperature Control. The Spectrophotometer Will Have Following Features: 1. Spectrophotometer Will Be Double Beam (Uv-Visible)/Reference Cell. 2. It Will Have High Resolution Touch Screen User Interface. The Spectrophotometer Must Be Capable Of Operating Through Computer Also. 3. There Will Be 8-Position Cell Changer With Switchable Turret. 4. It Will Have Onboard Methods, Reporting And Data Export. 5. It Will Be Networking Capable And Will Have Wifi-Adaptor. 6. It Is Capable Of Open Lid Operation. 7. There Will Be Room Light Resistance. 8. It Will Have Sipper (Optional). 9. It Must Accommodate Cells Upto 100 Mm Path Length. 10.There Shall Be 8-Position Cell Changer With Switchable Turret. 11. It Must Have Optional Facility For 4-Position Cell Changer (Long Path Cells) And Peltier-Thermostat Single Holder (200 Degree C-60 Degree C). Detector Type : Dual Silicon Photodiodes Display : 7-Inch Colour Touch Screen, High Definition, 800 X 1280 Pixels Photometric : ±0.002 A At 0.5 A Accuracy Instrument : ±0.004 A At 1.0 A : ±0.008 A At 2.0 A Wavelength Accuracy : ±0.5 Nm Baseline Flatness : ±0.002A Compartments : 8-Position Cell Changer (Standard) Also Accommodate (Optional):Peltier Thermostat Cell Holder (20-60 Degree Celsius) Sipper Accessory (Optional) Drift : (At 500 Nm After 1 Hour Warm-Up) <0.0005A/Hr Electricalrequirements : External Ac To Dc Converter, Voltage And Frequency (Hz) Selected Automatically, 100-240 Volts, 50-60 Hz Keypad : Touch Screen Lamp: Xenon Flash Lamp (>5 Years Typical, 3 Years Guaranteed) Noise : (Rms At 500 Nm 60 Consecutive Measurements) =0.00020A At 0A At 260 And 500 Nm = 0.00030A At 1A At 260 And 500 Nm =0.00040A At 2A At 260 And 500 Nm Optical Design: Double Beam Photometric Display : -3A To + 5A Photometric Range : -2A To +3.5A Photometric Repeatability ±0.001A At 1 A Measured At 1.0A At 546 Nm Spectral Bandwidth :2 Nm Stray Light < 1.0 % T 198 Nm (Kcl), <0.05% T At 220 Nm (Nacl), <0.03 % T At 340Nm (Nano2) Wavelength Data Interval : 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm Wavelength Range : 190 Nm – 1100 Nm Wavelength Repeatability : < ± 0.2 Nm Wavelength Scan Speed: Slow, Medium And Fast Up To 1600 Nm/Min Printer:Capable To Connect With Printer Computer Operation : The Spectrophotometer Can Be Operated From Compatible Computer And Software. Computer And Operational Software To Run Spectrophotometer Will Be A Part Of The Spectrophotometer. Connections: Single Usb-A Supports Flash Memory Devices For Method And Data Storage Duplex Usb-A On Side Supports Connection To A Computer Running Optional Remote Control Software, Keyboard, Mouse Export Data To Network Or Pc Via Usb, Ethernet, Or Wi-Fi Usb Adaptor, Available Print Via Usb, Ethernet Or Wi-Fi Usb Adaptor Available Warranty : 3 Years
Basic Detail
Tender No NIT No. 20(21-22)/CWA(WnS)II HP
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 07 Mar 2022
Submission Date 14 Mar 2022
Open Date 14 Mar 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 49600
Exemption Not Available
Document List
3cb3338a-36a4-489d-9dac-989630be9475.html
BOQ_281203.xls
NIT20doc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 14, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 14, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

3cb3338a-36a4-489d-9dac-989630be9475.html

xls

BOQ_281203.xls

pdf

NIT20doc.pdf

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders