Repairing Of Stators/Rotors Of Various Capacities 6.6 Kv/0.4Kv Motors Of 3X210 Mw, Atps, Anpara Sonebhadra U.P. As Per Scope Of Work. Repairing Of Stators/Rotors Of Various Capacities 6.6 Kv/0.4Kv Motors Of 3X210 Mw, Atps, Anpara Sonebhadra U.P. As Per Sc
Tender Overview
Project Description
Repairing Of Stators/Rotors Of Various Capacities 6.6 Kv/0.4Kv Motors Of 3X210 Mw, Atps, Anpara Sonebhadra U.P. As Per Scope Of Work. Repairing Of Stators/Rotors Of Various Capacities 6.6 Kv/0.4Kv Motors Of 3X210 Mw, Atps, Anpara Sonebhadra U.P. As Per Scope Of Work.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Mar-2022 | CORRIGENDUM1 | Date | 11-Apr-2022 |
| 2 | 11-Apr-2022 | DATE EXTENSION | Date | 28-Apr-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Rewinding/Repairing of 6.6 KV B.F.P. Motor stator ( 3500KW, 72 coils):- |
| 2 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 3 | Complete re insulation with class-‘F’ insulation and also replacement of damaged coils& replacement of all RTDs. |
| 4 | Stator core re-staggering per Cm length of stator core. |
| 5 | Rate of new coil with fresh copper |
| 6 | Rewinding/Repairing of 6.6 KV C.W. PUMP Motor stator (1825 KW, 108 coils) :- |
| 7 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 8 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 9 | Stator core re-staggering per Cm length of stator core. |
| 10 | Rate of new coil with fresh copper |
| 11 | Rewinding/Repairing of 6.6 KV I.D. Fan Motor stator (1520 KW 72 coils) :- |
| 12 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 13 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 14 | Stator core re-staggering per Cm length of stator core. |
| 15 | Rate of new coil with fresh copper |
| 16 | Rewinding/Repairing of 6.6 KV P.A. Fan Motor stator (1250/1320 KW 60 coils) :- |
| 17 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 18 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 19 | Stator core re-staggering per Cm length of stator core. |
| 20 | Rate of new coil with fresh copper |
| 21 | Rewinding/Repairing of 6.6 KV F.D. Fan Motor stator (750 KW 60 coils) :- |
| 22 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 23 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 24 | Stator core re-staggering per Cm length of stator core. |
| 25 | Rate of new coil with fresh copper |
| 26 | Rewinding/Repairing of 6.6 KV C.E.P. Motor stator (500 KW 60 coils):- |
| 27 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 28 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 29 | Stator core re-staggering per Cm length of stator core. |
| 30 | Rate of new coil with fresh copper |
| 31 | Rewinding/Repairing of 6.6 KV CRW Pump Motor stator (430 KW, 72 coils):- |
| 32 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 33 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 34 | Stator core re-staggering per Cm length of stator core. |
| 35 | Rate of new coil with fresh copper |
| 36 | Rewinding/Repairing of 6.6 KV Bowl Mill Motor stator (340KW, 54 coils):- |
| 37 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 38 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 39 | Stator core re-staggering per Cm length of stator core. |
| 40 | Rate of new coil with fresh copper |
| 41 | Rewinding/Repairing of 6.6 KV PRW Pump Motor stator (300KW, 60 coils) :- |
| 42 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 43 | Complete re insulation with class ‘F’ insulation and also replacement of damaged coils& replacement of all RTDs. |
| 44 | Stator core re-staggering per Cm length of stator core. |
| 45 | Rate of new coil with fresh copper |
| 46 | Rewinding/Repairing of 6.6 KV CLR Pump Motor stator (200KW, 48 coils):- |
| 47 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 48 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 49 | Stator core re-staggering per Cm length of stator core. |
| 50 | Rate of new coil with fresh copper |
| 51 | Rewinding/Repairing of 6.6 KV Ash Slurry Pump Motor stator (225KW, 72 coils):- |
| 52 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 53 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 54 | Stator core re-staggering per Cm length of stator core. |
| 55 | Rate of new coil with fresh copper |
| 56 | Rewinding/Repairing of 6.6 KV PAC Motor stator (185KW, 48 coils):- |
| 57 | Complete rewinding with fresh copper and class ‘F’ insulation & replacement of all RTDs. |
| 58 | Complete re insulation with class ‘F’ insulation with replacement of damaged coils& replacement of all RTDs. |
| 59 | Stator core re-staggering per Cm length of stator core. |
| 60 | Rate of new coil with fresh copper |
| 61 | Repairing of 6.6 KV B.F.P. Motor rotor (3500KW):- |
| 62 | Reshafting of rotor |
| 63 | Replacement of bars |
| 64 | Repairing of both sides bearing Journal Portion |
| 65 | Rotor core re-staggering |
| 66 | Dynamic balancing of rotor |
| 67 | Repairing of 6.6 KV C.W. PUMP Motor rotor (1825 KW): - |
| 68 | Reshafting of rotor |
| 69 | Replacement of bars |
| 70 | Repairing of both sides bearing Journal Portion |
| 71 | Rotor core re-staggering. |
| 72 | Dynamic balancing of rotor |
| 73 | Repairing of 6.6 KV I.D. Fan Motor rotor (1520 KW):- |
| 74 | Reshafting of rotor |
| 75 | Replacement of bars |
| 76 | Repairing of both sides bearing Journal Portion |
| 77 | Rotor core re-staggering. |
| 78 | Dynamic balancing of rotor |
| 79 | Repairing of 6.6KV P.A. FanMotor rotor (1250/1320 KW ): - |
| 80 | Reshafting of rotor |
| 81 | Replacement of bars |
| 82 | Repairing of both sides bearing Journal Portion |
| 83 | Rotor core re-staggering. |
| 84 | Dynamic balancing of rotor |
| 85 | Repairing of 6.6 KV F.D. Fan Motor rotor (750 KW) : - |
| 86 | Reshafting of rotor |
| 87 | Replacement of bars |
| 88 | Repairing of both sides bearing Journal Portion |
| 89 | Rotor core re-staggering. |
| 90 | Dynamic balancing of rotor |
| 91 | Repairing of 6.6 KV C.E.P. Motor rotor (500 KW): - |
| 92 | Reshafting of rotor |
| 93 | Replacement of bars |
| 94 | Repairing of both sides bearing Journal Portion |
| 95 | Rotor core re-staggering. |
| 96 | Dynamic balancing of rotor |
| 97 | Repairing of 6.6 KV CRW Pump Motor rotor (430 KW): - |
| 98 | Reshafting of rotor |
| 99 | Replacement of bars |
| 100 | Repairing of both sides bearing Journal Portion |
| 101 | Rotor core re-staggering. |
| 102 | Dynamic balancing of rotor |
| 103 | Repairing of 6.6 KV Bowl Mill Motor rotor (340KW):- |
| 104 | Reshafting of rotor |
| 105 | Replacement of bars |
| 106 | Repairing of both sides bearing Journal Portion |
| 107 | Rotor core re-staggering. |
| 108 | Dynamic balancing of rotor |
| 109 | Repairing of 6.6 KV PRW Pump Motor rotor (300KW): - |
| 110 | Reshafting of rotor |
| 111 | Replacement of bars |
| 112 | Repairing of both sides bearing Journal Portion |
| 113 | Rotor core re-staggering. |
| 114 | Dynamic balancing of rotor |
| 115 | Repairing of 6.6 KV Ash Slurry Pump Motor rotor (225KW): - |
| 116 | Reshafting of rotor |
| 117 | Replacement of bars |
| 118 | Repairing of both sides bearing Journal Portion |
| 119 | Rotor core re-staggering. |
| 120 | Dynamic balancing of rotor |
| 121 | Repairing of 6.6 KV CLR Pump Motor rotor (200KW): - |
| 122 | Reshafting of rotor |
| 123 | Replacement of bars |
| 124 | Repairing of both sides bearing Journal Portion |
| 125 | Rotor core re-staggering. |
| 126 | Dynamic balancing of rotor |
| 127 | Repairing of 6.6 KV PAC Motor rotor (185KW): - |
| 128 | Reshafting of rotor |
| 129 | Replacement of bars |
| 130 | Repairing of both sides bearing Journal Portion |
| 131 | Rotor core re-staggering. |
| 132 | Dynamic balancing of rotor |
| 133 | Repairing of 3-Phase Squirrel Cage Induction Motor 440V of Various RPM |
| 134 | Up to1.0 KW |
| 135 | Above 1.0 KW up to 2.5 KW |
| 136 | Above 2.5 KW up to 5 KW |
| 137 | Above 5 KW up to 10 KW |
| 138 | Above 10 KW up to 12.5 KW |
| 139 | Above 12.5 KW up to 15 KW |
| 140 | 15 KW (double speed 1480/980 rpm) |
| 141 | Above 15 KW up to 20 KW |
| 142 | Above 20 KW up to 30 KW |
| 143 | Above 30 KW up to 40 KW |
| 144 | Above 40 KW up to 55 KW |
| 145 | Above 55 KW up to 65 KW |
| 146 | Above 65 KW up to 80 KW |
| 147 | Above 80 KW up to 90 KW |
| 148 | Above 90 KW up to 110 KW |
| 149 | Above 110 KW up to 125 KW |
| 150 | Above 125 KW up to 140 KW |
| 151 | Above 140 KW up to 160 KW |
| 152 | Repairing of Single Phase 240V AC Squirrel Cage Induction Motor |
| 153 | Up to 0.25 kW |
| 154 | Above 0.25 KW up to 0.5 KW |
| 155 | Above 0.5 KW up to 1.0 KW |
| 156 | Repairing of Special Motor of EOT Crane 3-Phase 415/240 V AC Wound Rotor Type |
| 157 | Up to 1.0 KW |
| 158 | Above 1.0 KW up to 2.5 KW |
| 159 | Above 2.5 KW up to 5 KW |
| 160 | Above 5 KW up to 10 KW |
| 161 | Above 10 KW up to 15 KW |
| 162 | Above 15 KW up to 20 KW |
| 163 | Above 20 KW up to 25 KW |
| 164 | Above 25 KW up to 30 KW |
| 165 | Repairing of 3-Phase 415 V Submersible Pump Motor |
| 166 | Up to 2.5 KW |
| 167 | Above 2.5 KW up to 5 KW |
| 168 | Above 5 KW up to 10 KW |
| 169 | Above 10 KW up to 15 KW |
| 170 | Repairing of 220V D.C. Motor/Generator |
| 171 | Up to 2 KW |
| 172 | Above 2 KW up to 5 KW |
| 173 | Above 5 KW up to 10 KW |
| 174 | Above 10 KW up to 15 KW |
| 175 | Repairing of Control Transformer (415/230/110 V) |
| 176 | Up to100 VA |
| 177 | Above 100 VA up to 500 VA |
| 178 | Above 500 VA up to 1000 VA |
| 179 | Above 1000 VA up to 2000 VA |
| 180 | Special Motors |
| 181 | DC/AC 1-Phase upto 1KW |
| 182 | Universal motors upto 1KW |
| 183 | Lead Repairing of 3-Phase Squirrel Cage Induction Motor 440V of Various RPM |
| 184 | Up to1.0 KW |
| 185 | Above 1.0 KW up to 2.5 KW |
| 186 | Above 2.5 KW up to 5 KW |
| 187 | Above 5 KW up to 10 KW |
| 188 | Above 10 KW up to 12.5 KW |
| 189 | Above 12.5 KW up to 15 KW |
| 190 | 15 KW (double speed 1480/980 rpm) |
| 191 | Above 15 KW up to 20 KW |
| 192 | Above 20 KW up to 30 KW |
| 193 | Above 30 KW up to 40 KW |
| 194 | Above 40 KW up to 55 KW |
| 195 | Above 55 KW up to 65 KW |
| 196 | Above 65 KW up to 80 KW |
| 197 | Above 80 KW up to 90 KW |
| 198 | Above 90 KW up to 110 KW |
| 199 | Above 110 KW up to 125 KW |
| 200 | Above 125 KW up to 140 KW |
| 201 | Above 140 KW up to 160 KW |
| 202 | Lead Repairing of Single Phase 240V AC Squirrel Cage Induction Motor |
| 203 | Up to 0.25 kW |
| 204 | Above 0.25 KW up to 0.5 KW |
| 205 | Above 0.5 KW up to 1.0 KW |
| 206 | Lead Repairing of Special Motor of EOT Crane 3-Phase 415/240 V AC Wound Rotor Type |
| 207 | Up to 1.0 KW |
| 208 | Above 1.0 KW up to 2.5 KW |
| 209 | Above 2.5 KW up to 5 KW |
| 210 | Above 5 KW up to 10 KW |
| 211 | Above 10 KW up to 15 KW |
| 212 | Above 15 KW up to 20 KW |
| 213 | Above 20 KW up to 25 KW |
| 214 | Above 25 KW up to 30 KW |
| 215 | Lead Repairing of 3-Phase 415 V Submersible Pump Motor |
| 216 | Up to 2.5 KW |
| 217 | Above 2.5 KW up to 5 KW |
| 218 | Above 5 KW up to 10 KW |
| 219 | Above 10 KW up to 15 KW |
| 220 | Lead Repairing of 220V D.C. Motor/Generator |
| 221 | Up to 2 KW |
| 222 | Above 2 KW up to 5 KW |
| 223 | Above 5 KW up to 10 KW |
| 224 | Above 10 KW up to 15 KW |
| 225 | Lead Repairing of Control Transformer(415/230/110 V) |
| 226 | Up to100 VA |
| 227 | Above 100 VA up to 500 VA |
| 228 | Above 500 VA up to 1000 VA |
| 229 | Above 1000 VA up to 2000 VA |
| 230 | Lead Repairing of Special Motors |
| 231 | DC/AC 1-Phase below 1KW |
| 232 | Universal motors |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender