| 1 | Earth work in excavationin foundation, trenches, manholes, road side chambers etc. including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated material ,refilling after layig pipes/ foundation & disposal of surplus excavated material at lead upto 50 mtr suitable as per direction of engineer All kinds of soils. depth upto 1.5m |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8(1 cement :4 coarse sand : 8 graded stone aggregate 40mm nominal size). |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 4 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings,balconies, etc. |
| 5 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor fivelevel for Columns, pillars, posts and struts etc |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers, abutments, posts and struts etc.upto twostories excluding cost of centring, shuttering, finishing and reinforcement :1:1½:3 (1 cement :1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 7 | ProvidingandfabricatingreinforcementforR.C.C.workincludingstraightening,cutting,bending,placinginpositionandbinding(includingcostofbindingwire)allcompleteuptofloorfive level.TMT BARS |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement:M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix) |
| 9 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 10 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto two stories. in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructure. |
| 11 | Cement Plastering on new surface of walls including ( T&P) Scafolding material & complete labour for fixing of material for including cost of water & curing racking of jointscement sand mortar 1:6 ( 20 mm thick.) |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
| 13 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 14 | Paintingwithsyntheticenamelpaintofapprovedbrandandmanufactureto giveanevenshade :(i) Two or more coats on new work |
| 15 | Providing and fixing G.I. pipes complete with G.I.fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall 15 mmdia. nominal bore |
| 16 | Providing and fixing G.I. pipes complete with G.I.fittings and clamps, including cutting and making good the walls etc. Internal work - 25 mm dia. nominal bore |
| 17 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)15 mm nominal bore |
| 18 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)25 mm nominal bore |
| 19 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 20 | Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer in-Charge. Granite work. |
| 21 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. South (Red) 1501 Cm2 to 3600 Cm2 Tiles |
| 22 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 610x510 mm bowl depth 200 mm. |
| 23 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes75 mm diameter |
| 24 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 25 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 26 | Brick work with bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 27 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
| 28 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand) |
| 29 | Neat cement punning |
| 30 | Centring and shuttering upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 31 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix) |
| 32 | Providing at site, lowering & laying in trenches, aligning & jointing of PVC-U pipes (SN 8) as per IS 15328 (amended up to date) and as per specifications with rubber rings with socket and spigot joint , (EPDM/SBR) for all depths for pipe length as per drawing and specification including hydraulic field testing and commissioning etc complete as directed by Engineer. 160 mm Nominal Dia |
| 33 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 34 | Carriage of Materials by mechanical transport including loading, unloading and stacking with lead of 5 km :: Earth |
| 35 | Providing and fixing of reinforced Ferro-Cement drain covers designed for \"AA\" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per pproved design etc. Standard Size 2100x500mm for span 1201 to 1500mm |
| 36 | Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion/ rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I -& II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water). 150 mm dia Nominal bore |
| 37 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stoneaggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with afloating coat of neat cement complete as per standard design :With F.P.S. bricks |
| 38 | Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks |
| 39 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes75 mm diameter |
| 40 | 110 mm diameter |
| 41 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler, 110 mm |
| 42 | Single tee with door, (110x110x110 mm) |
| 43 | Single tee without door, (110x110x110 mm) |
| 44 | Bend 87.5° 110 mm bend |
| 45 | Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws ofrequired length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 46 | Supplying & fixing 560mm dia SFRC manhole frame & cover in existing manholes including grouting the frame in PCC M-15 complete in all respect as directed by the Engineer. EHD-35 |
| 47 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). |
| 48 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 49 | Providing Barricading for Trenches using 80 - 100 mm dia Wooden Ballies as vertical post, atleast 1.5m above ground level and atleast 30-45 cm below ground level at a spacing of 3 m. Two rows of PVC Tape (preferabley red in colour) strip barricading horizontal strip securely tied by the vertical members. Vertical members shall be painted in red and white colour. Rate is inclusive removal and cleaning of site complete in all respect |
| 50 | Wiring of light point /fan point/exhaust fan point/ cell point with 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit & its accessories, round tiles 18 SWG M.S. box with earth terminal screwlees cage connectors for neutral looping in switch board & false ceiling point,6A switch. 3,0mm thick phenolic laminated sheet zinc plated/brass screws cup washers making connections, testing etc. as required (Group-1)(A)short point upto 3 mtr. |
| 51 | (B) Medium Point upto 6 mtr. |
| 52 | (c) Long point upto 20 mtr. |
| 53 | Wiring of 3 pin 5 amp. light plug point with 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 KV grade and 1.5 sqmm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS:694) of approved make in surface/recessed ISI marked medium duty PVC conduit & its accessories, 18 SWG M.S. box with earth terminal screwlees cage connectors for neutral looping in switch board & false ceiling point, 6A switch. 6A socket, 3,0mm thick phenolic laminated sheet zinc plated/brass screws cup washers making connections, testing etc. as required (Group-1) on board |
| 54 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor I/ sl marked (IS:694) of 1.1 KV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required, (Gr.1) 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 55 | Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175X100X60mm on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet making connection testing etc. as required (Gr.1) |
| 56 | P/F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C/D/ tripping characteristic) ISI marked IS: 8828 (1996) conforming to IEC 60898 in existing board/ sheets including making connections with lugs, testing etc. as required : single pole MCB & Neutral MCB 6A to 32A rating (Gr.1) |
| 57 | P/F 240/415 V Isolator confirming to IS:13947-III/IEC 60947-3 on existing board/ sheets including making connections with lugs testing etc. as required double pole lsolators 30A /40A rating (Gr.1) |
| 58 | P&F recessed/surface mounting heavy duty horizontal type sheet steel distribution board phpphatised/powder painted complete with 100A copper bus, shorting link, neutral link, earth link and din bar, conforming to IS:13032& IS: 8623 including making intemal DB terminations with copper plugs, testing etc. (Gr.1)(a) Single door (three phase) 4 way |
| 59 | P&F double ball bearing capacitor start ceilling fan of approved make complete with regulator and other accessories as required 1200mm sweep |
| 60 | P&F of Heavy duty capacitor start 900/ 1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connectionstesting etc. as required. 380 mm sweep (900/ 1400 RPM) |
| 61 | P & F ISI marked (IS :3854) 6 amp. porcelain base single pole tumbler switch including making connection testing etc. as required. |