| 1 | Laying and Jointing PVC Pipe. Heading |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.a) All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 5 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 6 | Dismantling 40mm thick marble chips flooring / tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead |
| 7 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth lvl :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto all level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.12 mm dia |
| 13 | RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.16 mm dia |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, columns,footing, landings, balconies and access platform |
| 15 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 16 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 17 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 18 | Supplying and Laying of Polyurethane Flooring 4MM Thick SL System including Joint Cutting & Filling with floor repairing. Works shall include Surface Preparation, filling grooves with PU Compatible sealant, Primer screed followed by sealer coat and high abrasion resistant and impact resistent) Polyurethane Primer - 200 MicronPolyurethane Screed - 2800 MicronPolyurethane SL - 1000 Micron.Work shall be done by OEM approved by the College Authorities. The OEM shall first install one 3m x 3m sample of the product at the location specified by the college authorities for approval from the college authorities before proceeding with the work in the library. |
| 19 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 20 | 12/15 mm cement plaster of mix (Junctions of all RCC and brick shall be provided with chicken wire mesh of 150 mm width on either side of the junction before plastering)1:3:3 (1 cement: 3 course sand: 3 fine sand) |
| 21 | PAINT WORK:1) Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete:2) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete:3) Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre:4) Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work |
| 22 | Wiringfor the following lightpoints with1.5sq.mmPVCinsulatedcopperconductor 1100 volts gradestrandedflexible FRLS wires of approvedmake in concealedor surface mounted 25 mm dia 16 gauge MS Conduit including providing and fixing of 6 amps single pole modular switch of approved quality colour make & design in 1.6mmthickGIboxandearthingof fixturesandthe outlet boxwith1.5 sq.mmPVCinsulatedcopperconductorstranded flexible \"FRLS\" wire. |
| 23 | Wiring for ceiling fan point with 1.5 sq.mm PVC insulated copper conductor 1100volts grade stranded flexible \"FRLS\" wires in concealed or surface mounted 25 mm dia 16 gauge MS conduits, including providing fan hook box, 6 amps switch and 300 watts electronic step type fan regulator of approved make in GI box and earthing the fan and outlet box with 1.5 sq. mm. PVC insulated copper conductor stranded flexible FRLS wire.(including circuit wiring from DB to switch Board). |
| 24 | Wiring for 250 volts single phase and neutral 16 amps modularswitch socket outlet with universal pins with 3 x 4 sq.mm PVC insulated copper conductor 1100 volts grade strandedflexible \"FRLS\" wire in concealed or surface mounted25 mm dia 16 gauge MS conduit / existing raceway including providingand fixing of 16 amps 3 pin modular switchedsockets of approvedmake and design in 1.6 mm thick GI box withgrid plates and earthing the third pin ofeachsocket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible \"FRLS\" wire.Primary point for 16 amps switched socket outlet |
| 25 | Wiringfor 250 volts singlephaseand neutral6 amps modular switch socketoutletwith universal pinswith3x2.5sq.mmPVC insulated copper conductor 1100 volts grade strandedflexible \"FRLS\" wire in concealed orsurfacemounted25 mm dia 16 gaugeMSconduit / existing raceway including providingand fixing of 6/16 amps3pinmodularswitchedsockets of approvedmake and designin1.6 mm thick GI box withgridplatesandearthing the thirdpinofeachsocketoutletwith2.5Sq mm PVCinsulated copperconductorstrandedflexible \"FRLS\" wire.Primary point for 6 amps switched socket outlet |
| 26 | Wiring for Exhaust fan point with 1.5 sq. mm. insulated copper conductor 1100 volts grade stranded flexible \"FRLS\" wires of approved make in concealed or surface mounted 25 mm dia 16 guage MS Conduit including providing and fixing of 6 amps flush mounted switch at the normal switch level in 2 mm thick GI box and 6 amps 3 pin flush mounted socket near exhaust fan and earthing of exhaust fan through the third pin of the socket outlet and GIbox with1.5 sq. mm. PVC insulatedcopperconductor flexible \"FRLS \" wire. |
| 27 | Providing and fixing in position the following 2mm thick PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design.20 mm dia PVC conduit |
| 28 | Providing and fixing in position the following 2mm thick PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design.25 mm dia PVC conduit |
| 29 | Supplying offollowing 1100 voltgrade XLPE insulated PVC sheathed copper conductor armoured cableas per specification.4 core 6 sq. mm |
| 30 | Supplying offollowing 1100 voltgrade XLPE insulated PVC sheathed copper conductor armoured cableas per specification.3 core 6 sq. mm |
| 31 | Supply,installation, testingand commissioning ofthe following cubicletype1.6mmthickCRCA sheet steel enclosed and partitions to segregate phases recessed inwallor surfacemounted finaldistributionboardsofthe following description.Distribution board shall be powder coated and double door construction and in four tier configuration.6 way TPN DB with 12 No 10/16/20/32 amps SP MCB as outgoing and 3 No. 32 amps DP RCCB’sof 100 mA leakage current including1 No. 16 amps 4 Pole MCB as incomer & separate neutral link for each phase and earth bar. |
| 32 | Supplying, fixing, testing and commissioning of following bare Copper/GI tapes including all necessary fixing accessories and effecting connections.8 SWG GI wire |
| 33 | Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. \" B \" class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300 mm and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance as required. |
| 34 | Supply, laying, connecting, testing and commissioing of Single core 120 sq.mm Green colour cable (UPS neutral earthing). |
| 35 | Supply, installation, testing and commissioing of Ceiling fan 1200 mm diaof approved make complete with all accessories as required. |
| 36 | SITC Propeller fan upto 450 mm sweep of approved make complete with louvers all accessories as required. |
| 37 | Supply, installation, testing and commissioing of 36 watt LED Tube Light |