Tender For Polymer Testing Lab Tender For Polymer Testing Lab , Polymer Testing Laboratory Equipments , Din Abrasion Tester• Emery Paper With Corundum Of 60 Grades • Dimensions Of Rotating Drum : 150 Mm Diameter Width X460 Mm Long • Speed Of Rotation Of
Tender Overview
Project Description
Tender For Polymer Testing Lab Tender For Polymer Testing Lab , Polymer Testing Laboratory Equipments , Din Abrasion Tester• Emery Paper With Corundum Of 60 Grades • Dimensions Of Rotating Drum : 150 Mm Diameter Width X460 Mm Long • Speed Of Rotation Of Drum : 40 Rpm • Lateral Movement Of Test Specimen Holder : 4.2 Mm Per Revolution Of Drum • Rotation Of Test Specimen : 1 • Load On Test Specimen : 5 / 10N• Total Length Of Abrasion Run : 40 Meters ( About 84 Revolutions ) • Abrasive Powering: 170Mg To 220 Mg • Accuracy : 1 Mg Others: • Annual Maintenance And Regular Periodic Calibration Service At Chennai Is Mandatory. • In House Test Report Is Mandatory. Remark: • Instrument Should Conform To Astm D 5963 Andspecimendimension Is 16Mm Diameter With Minimum 6 Mm Height , De-Mattia Flex Tester ( Fatigue Tester ) • Main Unit With A Cycle Counter: Six Digit Electronic Counter With Memory Back Up. • Max Opening Between Grips :- 75Mm ( Adjustable ) • Flexing Frequency: 5 Hz Or 300 Cpm. • Motor :0.5 Hp 1 Phase 50 Hz • Fixtures / Accessories : Mould For Specimen 3 Cavity • Jig & Punch Assembly For Crack Initiation In Test Specimen Others: • Annual Maintenance And Regular Periodic Calibration Service At Chennai Is Mandatory. • In House Test Report Is Mandatory. Remark: • Instrument Should Conform As Per Astm D 813 , Melt Flow Index Tester• Operating Temperature : Up To 300Oc • Accuracy : ± 0.2°C • Digital Timer : 1 No 3 Digits ( 999 Sec ) Preset With Indication & Buzzer • Sensor : Pt 100 • Diameter Of Heater Tube Cavity : 9.55 Mm • Dimensions Of Piston Head : 9.47 Mm • Diameter X 6.35 Mm Long • Dimensions Of Jet Holes : 2.095 Mm X 8.00 Mm Long • Weights : 325G, 1050G, 2160G & 5000G • Accessories: • Orifice : 1 No ( Tungsten Carbide ) • Piston: 1 No. Scoop : 1No • Orifice Cleaner: 1 No, Cleaning Cloth: 25 Nos. Sample • Cutter : 1No • Leveling Legs: 4 Nos. • Material Charger : 1 No • Spirit Level : 1 No • Barrel Cleaner: 1 No. • Tweezers : 1 No. Others: • Annual Maintenance And Regular Periodic Calibration Service At Chennai Is Mandatory. • In House Test Report Is Mandatory. Remark: • Instrument Should Conform As Per Astm D 1238 , Falling Dart Impact Tester • Method B: 300 ~ 2000 G • Accuracy: 0.1G ( 0.1J ) • Specimen Clamp: Pneumatic Clamp • Specimen Size: > 150 Mm X 150 Mm • Power Supply: 220Vac 50Hz / 120Vac 60Hz Others: • Annual Maintenance And Regular Calibration Service At Chennai Is Mandatory. • In House Test Report Is Mandatory. Remark: • Instrument Should Conform To Astm D 1709 => Limited
BOQ
| Sl. No. | Item Description |
| 1 | POLYMER TESTING LABORATORY EQUIPMENTS |
| 2 | DIN Abrasion Tester• Emery paper with corundum of 60 grades• Dimensions of rotating drum : 150 mm diameter width x460 mm long • Speed of rotation of drum : 40 rpm • Lateral movement of test specimen holder : 4.2 mm per revolution of drum • Rotation of test specimen : 1• Load on test specimen : 5/10N• Total length of abrasion run : 40 meters (about 84 revolutions)• Abrasive powering: 170mg to 220 mg • Accuracy : 1 mgOthers: • Annual maintenance and regular periodic calibration service at Chennai is mandatory.• In house test report is mandatory.Remark: • Instrument should conform to ASTM D 5963 andspecimenDimension is 16mm diameter with minimum 6 mm height |
| 3 | De-Mattia Flex tester (Fatigue tester) • Main unit with a Cycle Counter: Six digit electronic counter with memory back up.• Max Opening between grips :- 75mm (adjustable )• Flexing frequency: 5 Hz or 300 CPM.• Motor :0.5 HP 1 phase 50 Hz• Fixtures / Accessories : Mould for specimen 3 Cavity• Jig & punch assembly for crack initiation in test specimenOthers: • Annual maintenance and regular periodic calibration service at Chennai is mandatory.• In house test report is mandatory.Remark:• Instrument should conform as per ASTM D 813 |
| 4 | Melt Flow index Tester• Operating Temperature : up to 300oC• Accuracy : ± 0.2°C• Digital Timer : 1 no 3 digits (999 sec) preset with indication & buzzer • Sensor : PT 100 • Diameter of heater tube cavity : 9.55 mm• Dimensions of Piston head : 9.47 mm• Diameter x 6.35 mm Long• Dimensions of jet holes : 2.095 mm x 8.00 mm Long• Weights : 325g, 1050g,2160g & 5000g • Accessories: • Orifice : 1 No (Tungsten Carbide)• Piston: 1 No. Scoop : 1No• Orifice Cleaner: 1 No, Cleaning Cloth: 25 Nos. Sample• Cutter : 1No• Leveling Legs: 4 Nos.• Material Charger : 1 No• Spirit Level : 1 No• Barrel Cleaner: 1 No. • Tweezers : 1 No.Others: • Annual maintenance and regular periodic calibration service at Chennai is mandatory.• In house test report is mandatory.Remark: • Instrument should conform as per ASTM D 1238 |
| 5 | Falling Dart Impact Tester • Method B: 300 ~ 2000 g• Accuracy: 0.1g (0.1J)• Specimen Clamp: Pneumatic Clamp• Specimen Size: > 150 mm x 150 mm• Power Supply: 220VAC 50Hz / 120VAC 60HzOthers: • Annual maintenance and regular calibration service at Chennai is mandatory.• In house test report is mandatory.Remark: • Instrument should conform to ASTM D 1709 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed