Repair Maintenance Of Summer Cooling Appliances And Allied Works Under Ge Af Adm Area At Af Station Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Repair Maintenance Of Summer Cooling Appliances And Allied Works Under Ge Af Adm Area At Af Station Agra. Submission Date for this Tender is 29-03-2022. Air Conditioner Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31314014
Corrigendum : Repair Maintenance Of Summer Cooling Appliances And Allied Works Under Ge Af Adm Area At Af Station Agra
Open Tender
Indian
Uttar Pradesh
agra
29-03-2022

Tender Details

Repair Maintenance Of Summer Cooling Appliances And Allied Works Under Ge Af Adm Area At Af Station Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Mar-2022 Amendment01 BOQ 22-03-2022
2 22-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work:REPAIR/ MAINT OF SUMMER COOLING APPLIANCES AND ALLIED WORKS UNDER GE (AF) ADM AREA AT AF STATION AGRA
Sl. No. Item Description
1Preventing maintenance /Servicing of both the indoor/outdoor units of Towertype A/C 4.0TR capacity of any make by cleaning of cooling and condenser coil of indoor & outdoor unit, cleaning filters removing internal dust by using vacuum cleaners, oiling, greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed at site. Note : (i) Fixing of spares parts such as Compressor, starting capacitor, running capacitor, fan motor, blower motor, relays thermostat & wiring, copper tubes, PVC pipes etc. if found defective will be measured and paid separately as supply only. (ii) Charging of gas if required will be paid separately as supply only.
2All as per item No. 1 above but for 1.5/2.0 TR capacity of spilt/window type AC.
3Supply only fins and tube type air cooled condenser suitable for any make split type AC of cap of 1.5/ 2 TR
4Supply only new fan motor for outside condenser unit of split AC of capacity 1.5/ 2 TR/ 54 Watt, 220 V or existing size and testing complete all as directed. Make- American Universal/Khaitan / Usha or equivalent
5Supply only blower fan motor Kit of spilt type AC 1.5/2 Ton capacity and testing complete all as directed. Make- American Universal/Khaitan / Usha/ LG/Blue star/Voltas/Hitachi or equivalent
6Supply only copper refrigerant pipe one run1/4 Inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed. Note One Run of 1/4 inches dia pipe with insulation will be measured as one RM.
7Supply only copper refrigerant pipe one run 5/8 inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed Note:- One Run of 5/8 inches dia pipe with insulation will be measured as one RM.
8Supply only copper refrigerant pipe one run 1/2 inches dia, superior quality with foam armor for suction line/delivery line for spilt type AC complete all as directed. Note :- One Run of 1/2 inches dia pipe with insulation will be measured as one RM.
9Supply only PVC pipe 20 mm dia heavy duty transparent flexible for drainage water system of split AC complete with clamp fitting and drilling all as per ground requirement and as directed.
10Supply only complete remote assembly with suitable battery for any type & make of Split/window AC.
11Supply only starting capacitor for blower motor 4 / 6 MFD for split type AC 1.5 TR / 2 TR capacity complete all as directed. Make-Tesla/ Asian/ Keltron/ Sarda
12Supply only running capacitor 50/60 MFD suitable for rotary type compressor 1.5 TR/2 TR split/ window AC at site and making connection using PVC insulated copper wire and thimbles complete all as directed. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
13Supply only capacitor 80/100 MFD suitable for reciprocating type compressor1.5 TR/2 TR split AC at site and making connection using PVC insulated copper wire and thimbles complete all as specified and directed. Make-Tesla/Asian/ Keltron/Sarada/Unistar.
14Supply only starting relay of window/split type AC upto 2.0 ton capacity and testing complete Make- Arvind/ Soletron / Hitech
15Supply only and taking out unserviceable compressor sealed unit of 1.5 TR capacity, reciprocating/Rotary from the spilt type AC (Make : LG/Blue star/Voltas/Hitachi etc.) single phase 230 volts and replacing the same with new compressor sealed unit fixing and vacuumization pressure testing leakage rectification and charging refrigerant gas and testing complete. Note :- Compressor supplied shall be of same make as of existing make.
16All as per item No. 15 above but for 2.0 TR capacity.
17All as per item No. 15 above but for 1.5TR/2.0 TR capacity of Window type.
18Taking down 1.5/2.0 ton capacity split type AC complete with indoor unit, outdoor unit and refrigerant pipe and re-fixing the same in other room of same building or another building including testing and commissioning detailed as under :- (a) Cooling unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water including fixing of interconnection pipe all as directed. (b) Erection of condenser, compressor unit on outside of the building, fixed over suitable size of clamp/bracket.(Old clamp/bracket retrieved from demolition shall be reused in case old clamp/bracket found serviceable) (c) All civil work as plastering, cementing, whitewashing, filling of existing hole etc.required to be done as per site requirement at both the places(from where taken down and at place of re-fixing) NOTE:-(i) Charging / toping up gas if required will be measured & paid separately as supply only. (ii) Additional length of copper tubing if required will be measured & paid separately.
19Taking down 1.5/2.0 ton capacity Window type AC complete and refixing the same in other room of same building or another building including testing and commissioning detailed as under :- (a)All required requisite work such as cutting/drilling/fixing shall be part of the Job in quoted rate. NOTE:- (i) Charging / toping up gas if required will be measured & paid separately as supply only.
20Supply only of Thermostat switch of window type AC 1.5 TR/2 TR capacity including connection with appropriate size of PVC copper cables thimbles sleeves etc complete all as specified and directed. Make-Renutrol/ Indofoss or equivalent
21Removing burnt blower motor, off sizes from condensing/cooling unit of window/split type AC 1.5 TR/2TR from the machines at site, removing to workshop, dismantling & rewinding with super enameled copper wire using best quality winding materials bushes reassembling the motor replacing the bushes/bearing, starting condenser, re-fixing the blower motor at site after testing and making connection complete all as specified and directed..
22Supply only starting relays including connections completefor 1.5 TR or 2 TR capacity compressor of window type A/C all as specified and directed. Make – Ranutrol / Shri Ram or equivalent
23S&F waterproof ply wood 4 mm thick commercial type fixed around the window type AC or where else required including cutting and making good the disturbed surface all as directed.
24Supply only metal clamp /bracket for outdoor unit of split type AC 1.5/2.0 ton capacity.
25S&F in repairs foam armor of size 5/8" for copper refrigerant pipe of AC complete.
26S&F in repairs foam armor of size 1/4" for copper refrigerant pipe of AC complete.
27M&L for pressure testing of split type AC 1.5/2.0 Ton capacity and rectifying the leakage of refrigerant gas in the system, including vacuuming and charging only gas including testing and commissioning complete. NOTE- Supply only gas will be measured & paid separately.
28Taking down the old unserviceable front grills and supply and fixing new front grills of Window type AC of cap 1.5/2 Ton any size/make as per site requirement to match the existing complete all as specified and as directed.
29Preventing maintenance/Servicing of Refrigerator of any capacity and make by cleaning of cooling and condenser coil ofchecking of refrigerant pressure and charging of refrigerant gas, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed. Note : (i) Fixing of spares parts such as Compressor, starting capacitor, running capacitor , fan motor , blower motor, relays thermostat & wiring, copper tubes etc if found defective will be measured and paid separately as supply only. (ii) Charging of gas if required will be paid separately as supply only.
30Supply only Overload protector suitable for Refrigerator of any capacity
31Supply only 5 watt cabin bulb with holder & cabin bracket for refrigerator
32Supply only fan motor suitable for Refrigerator 165 to 330 litres capacity
33Supply only timer switch suitable for Refrigerator 165 to 330 Litres capacity of existing make
34Supply only box type relay for refrigerator of any capacity of best quality Make-Renutrol / INDFOSS / LG.
35Supply onlycooling coil for refrigerator 165 to 210 litres capacity
36Supply only cooling coil for refrigerator 280 to 330 litres capacity
37Supply only thermostat switch for refrigerator 165 to 210 litre capacity.
38Supply only thermostat switch for refrigerator 280 to 330 litre capacity.
39Supply only of freezer square ice tray reliable and crack proof with minimum 12 slots and of suitable size complete all as directed.
40Supply only Acrylic freezer vegatable tray of existing size reliable and crack proof complete all as directed
41Taking out unserviceable compressor sealed unit of refrigerator(make-Whirlpool/Kelvinator/Genius Supreme/LG/Samsung etc) 165 to 210 litres capacity, single phase 230 volts and replacing the same with new compressor sealed unit Fixing & connecting the same including vacuumization, pressure testing leakage rectification and supply charging refrigerant gas and testing complete.
42M&L for taking out unserviceable compressor sealed unit of refrigerator(make-Whirlpool/Kelvinator/Genius Supreme/LG/Samsung etc) 280 to 330 litres capacity, single phase 230 volts and replacing the same with new compressor sealed unit Fixing & connecting the same including vacumization, pressure testing leakage rectification and supply charging refrigerant gas and testing complete. Note for item No. 41 & 42:- Compressor supplied shall be of same make as of existing make.
43Preventing maintenance/Servicing of Deep Freezer of anycapacity and make by cleaning of cooling and condenser coil ofchecking of refrigerant pressure and charging of refrigerant gas, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed.
44Preventing maintenance/Servicing of Water cooler of anycapacity and make by cleaning of cooling and condenser coil ofchecking of refrigerant pressure and charging of refrigerant gas, cleaning filters removing internal dust by using vacuum cleaners, oiling greasing wherever required, checking for proper cooling, checking of serviceability of spares such as stating capacitor, running capacitor, fan motor, blower motor, relays, thermostat and wiring etc and service complete all as directed. Note for item No. 43 & 44: (i) Fixing of spares parts such as Compressor, starting capacitor, running capacitor , fan motor , blower motor, relays thermostat & wiring, copper tubes etc if found defection will be measured and paid separately as supply only. (ii) Charging of gas if required will be paid separately as supply only.
45Dismantling of water cooler, storage tank by unscrewing the outer body taking out the storage tank, carrying to local work shop and making it leak proof by means of breezing/soldering and assembling the water cooler after providing proper insulating material and breezing inlet and outlet wash out and over flow connections and testing complete for any leakage complete all as specified and directed.
46Supply only thermostat switch of water cooler complete with connection using appropriate size of PVC copper cable sleeves thimbles etc complete all as directed for water coolers of capacity from 40/80 to 150 Liters.
47Supply only box type relay of water cooler of 40/80 to 150 liters capacity & testing complete
48M&L Aluminium blade for condensing blower motor of water cooler any model/size as per site requirement.
49Supply only push cock of water cooler, brass chromium plated, 15mm size self closing type.
50Supply only fan motor of water cooler 40/80 to 150 liters capacity & testing complete. Make : Khaitan/ Usha/ Crompton
51supply only copper condenser coil for water cooler 40/80 to 150 liters capacity & testing complete.
52Supply only starting relays for water cooler of capacity from 40 to 150 liters all as specified. Make- RANUTROL/SHRI RAM/INDFOSS.
53Taking out unserviceable compressor sealed unit of water cooler (Make-Shriram/ Usha/ Blue star) of capacity 40/80/150 liter capacity, single phase 230 volts, & replacing the same with new compressor sealed unit fixing & connecting the same including vacuumization, pressure testing leakage rectification and supply and charging refrigerant gas and testing complete. NOTE- Compressor supplied shall be of same make as of existing make.
54Suuply onlygas charging the systemwith correct quantity ofR-32/R-22/R-410/R-407/R-134 gas for split/window type A/C of 1.5 TR/2 TR/3 TR/4 TRcapacity/Refrigerator/Deepfreezer/Water cooler and repairing the leakage in tube /lines by brazing and charging the unit with compressor oil charging replacing the capillary tube and copper liquid filter completeincluding fixing the same in position and testing and commissioning complete all as specified and directed.
55Repair/Maintenance/Over all servicing of desert cooler including all fitting and fixtures, replacement of grass pad set of any size of desert cooler to cover the entire area (one desert cooler consist three grass pad), PVC pipe and distribution cap etc including painting inner surface with one coat of black bituminous paint and outer surface of with grey/existing colour after preparation of the surface complete all as specified and directed Note : (i) Fixing of spares parts such as Motor, grass, clamp, pump etc if found defection will be measured and paid sperately as supply only.
56Supply only suitable size electric fan motor 1400 rpm single phase 230 volts for desert cooler/ ductable cooler. Make- Crompton Greaves/Khaitan/Bajaj or equivalent
57Supply only water lift pump (fully submersible) of existing size/capacity/makes for desert cooler. Make- Bajaj/Coolon or equivalent.
58Supply only fan blade metalic sheet metal made for desert cooler fan motor suitable for existing size of Desert cooler of any make/size motor all as specified and directed.
59Supply only front grill of existing size metallic body /PVC body work of desert cooler of any make/size including all fixing accessories all as specified and directed.
60All as per item No. 59 above Item but side window grill of desert cooler of any make/size all as specified and directed.
61Supply only control switch step type complete including necessary wiring completeand testing complete after fixing the control switchall as specified and directed.
62Supply only of water connection with PVC pipe 15mm dia and its connected pipe accessories(PTMT type) complete set for desert cooler/Ducable cooler of any make/size (One pipe from water motor and three pipes for distribution) complete all as specified and directed.
63Supply only MS clamp of suitable size as per existing for fixing and fitting the fan motor of desert cooler of any make/size withincluding making all water/electric connections, nuts, bolts and washers etc. complete all as specified and directed.
64Supply only wood wool pads complete all as directed.
65S&F desert cooler body made out of 22 gauge galvanized iron sheet duly painted with two coats of synthetic enamel paintover one coat of red oxide complete with three side detachable type perforated panel leak proof water tank without any joint plastic distribution pipe system suitable for 1/3” dia PVC pipeto run water over pads and overall dimension of desert cooler body not be less than size 65 cm x 65 cm x 75 cmwith all accessories and front grills but without fan kit & pump motor and fan motor. (Water tank depth should not less than 20 Cm)
66Supply only of the exhaust fan regulator for desert cooler of any size capacity including wiring complete all as specified and directed. Make-ANCHOR/KEY/CONA.
67Servicing ofheavy duty plastic body ductableAir coolers (Which cools on the principle of water evaporation) having option of air discharge from the top or bottom 200 liters waterstorage capacity, Axial fan with 1.1 KW, 3 phase, 50Hz Ac motor and 10000 CFM air flow capable to cool 1000 Sqft area with standard height of 10 feet. All sides of cooling cabinet shall be provided with 100 mm thick paper based honeycombstructure cooling media complete all as specified and directed. NOTE (i) Fixing of spares parts such as Motor, grass pad, capacitor, submersible pumps , canvas cloths, and internalwiring, clmapsetc if found defective will be measured and paid sperately as supply only.
68Supply only PVC water pipe distribution and PVC pipe connection pieces for water distribution for Ductable cooler incl. testing complete all as specified and directed.
69Supply onlyof MS clamp of suitable size as per existing for fixing and fitting the fan motor of ducablecoolers of any make/size withincluding making all water/electric connections, nuts, bolts and washers etc complete all as specified and directed.
70Disconnection and taking down the fan motor of Ductable cooler and refixing at the same location after rewinding by super enameled copper winding wire with existing size & guage with all insulation material including, varnishing & heating complete of the fan motor of desert cooler all as specified & as directed.
71Supply only heavy duty motor capacity Axial fan with 1.1 KW, 3 phase, 50Hz Ac for ductable Air coolersincluding testing and commissioning complete all as specified and directed.
72Supply onlyheavy duty water lifting pump (fully submersible) of existing size/capacity/make ofAir Ductable Coolers) including testing and commissioning complete all as specified and directed.
73Supply only canvas cotton duck canvas cloth with natural/existing color with existing size/color/make of ductable cooler including fixing arrangements complete all as directed.
74Supply and Replacement ofGI sheet of 22 gauge thick with TDF flange rectangular / square duct made out of "L" shaped, hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket, strengthening angle iron of suitable size & Length for supporting duct, Canvas, air deliver controlled fins, suitable size of each air deliver duct complete all as specified and directed.( Note: All accessories/material required for proper functioning of duct shall deemed to be included in quoted Rate) Make of sheet :- RINL / TISCO, OR TATA STEEL/ SAIL/ M/S JAI BALAJI INDUSTRIES LTD/ M/S SHYAM STEEL INDUSTRIES LTD/M/S SPS STEEL ROLLING MILLS LTD.
75S&F in repair MCB single pole 240 volts, "C" curve of rating from 6 to 32 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
76S&F in repair MCB SPN 240 volts, "C" curve of rating from 40 to 63 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
77S&F in replacementMCB TPN 415 volts, "C" curve of rating from 40 to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
78Preventing maintenance/Servicing and repair to voltage stabilizers 1 KVAand re-fixing at the original position complete all as specified.
79Preventing maintenance/Servicing and repair to voltage stabilizers 2 to 3 KVA and re-fixing at the original position complete all as specified.
80Preventing maintenance/Servicing and repair voltage stabilizers 5 KVAand re-fixing at the original position complete all as specified.
81S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 Sqmm nominal cross sectional area and one run of 4 Sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia "medium grade" PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
82S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run of 6 Sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20mm dia "medium grade" PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
83S&F in replacement sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
84M&L for fabricating and fixing of desert cooler/ ductable cooler stand using of angle iron/flat iron/channels etcincluding welding/bending/drilling holes/ bracing fixed to wall/window etc and applying one primer cote and one under and one finishing coat of paint complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail