Khairi Dnit For Providing New Canal Based Water Works Against Abandoned Water Works Functional House Hold Tape Connections And Laying The Balance Pipe Lines In Village Khairi Distt Hisar Under Jal Jeevan Mission Category Ii Const Of Rcc Np2 Pipe Channel 2, hisar-Haryana

Public Health Engineering Department-PHED has published Khairi Dnit For Providing New Canal Based Water Works Against Abandoned Water Works Functional House Hold Tape Connections And Laying The Balance Pipe Lines In Village Khairi Distt Hisar Under Jal Jeevan Mission Category Ii Const Of Rcc Np2 Pipe Channel 2. Submission Date for this Tender is 09-03-2022. Canal Construction Tenders in hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

31303620
Corrigendum : Khairi Dnit For Providing New Canal Based Water Works Against Abandoned Water Works Functional House Hold Tape Connections And Laying The Balance Pipe Lines In Village Khairi Distt Hisar Under Jal Jeevan Mission Category Ii Const Of Rcc Np2 Pipe Channel 2
Open Tender
Indian
Haryana
hisar
09-03-2022

Tender Details

Khairi Dnit For Providing New Canal Based Water Works Against Abandoned Water Works Functional House Hold Tape Connections And Laying The Balance Pipe Lines In Village Khairi Distt Hisar Under Jal Jeevan Mission Category Ii Const Of Rcc Np2 Pipe Channel 2 No Rcc Ss Tank Suction Scour Well 2 Nos Rcc Cwt Const Of 1 Mld Wtp Pc Sv Houdi B Wall Road Path Pl At Hworks Pmachinery Disty Sys Repair Of Existing Structures Of Bs 1And2 Oandm For 5 Yrs After 1 Yr Defect Liability => Limited

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Mar-2022 CORRIGENDUM Other 09-03-2022

Key Value

Document Fees
INR 15000 /-
EMD
INR 812200.0 /-
Tender Value
INR 4.06 Crore /-

BOQ Items

Name of the work– KHAIRI : DNIT for providing New canal based water works against abandoned water works Functional house Hold Tape Connections and Laying the balance pipe lines in villageKhairi Distt. Hisar (Under Jal Jeevan Mission Category-(II) "Construction of RCC NP2 pipe channel, 2 Nos. RCCS/S Tank, Suction Scure well,2 Nos. RCC Clear water tank, Construction of 1 MLD WTP, Pump Chamber, S.V Houdi, Boundary Wall, Road & Path, Pipe Line at Head Works, Pumping Machinery, Distribution System, FHTCand Repair of existing structures of boosting station 1 & 2, O & M for five years after one year defect liability period and3 month trial run period and all other works contigent thereto."
Sl. No. Item Description
1Construction of 1.00 MLD Rapid Sand Filtration plant Comprising of Labor For DI Pipe from existing Raw water/ Pump, Inlet Box, Inlet channel, Alum Dozing, Flash Mixing, Tapered Flocculate, Rectangular setting tank, filter box, Over hear reservoir for back wash including pump sets and electric control penal, sluice valve houdi, Di Pipes , Di Specials Manhole Covers, air squer equipment, Chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respect as per DNIt . Labor rate for fixing DI, S/S class K9 ISI marked pipe including cost of DI specials/fitting. ISI marked PN 1.6 sluice valve including cost of excavation, layig, cutting, jointig,threading,and jointing material in horizontal length including connections complete in all respect. From existing raw water tank. NOTE - Di Pie will be supplied by the departmental free of cost ( BASED ON SCADA SYSTEM – 1.00 MLD WTP)
2Supply & Erection of Horizontal spindle split casing type pumping sets of minimum Four (4) Star rating duties directly coupled to AC squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement and complete base frame as per IS marked complete in all respect A) Raw Water Pump 1100 LPM, 12.00 Mtrs. Head 10.00 BHP
3Supply, erection, testing and commissioning of Wall mounted electrical panel board. fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated e deep having following items : approximate size 500 x 1200mm and 400mm deep having following accessories comlete in all respect as per approved NIT a) Incomer switch 200 amp b) Aluminum bus bar chamber of 300 Amp. Capacity c) Volt meter 100 x 100mm range 0 to 500 volt 2 No.(AE/KAPPA/L&T) d) IncludingLamp-One set
4Supply, erection, testing and commissioning of Wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm and 400mm deep having following items : A) For Raw water pump sets for 1100 Lpm x 12 M head = 2 No. AT WIW a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1 No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g)motor starter, star dela, 2 No. for 1100 LPM x12M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable capacity 2 Nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
5B) For Clear water pump sets for 2200 Lpm x 40 M head = 2 No. AT WIW a) Main switch 100 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 2 No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 2 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motorstarter, star dela,No. for 2200 LPM x40 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 100 Amp = 1 No )
6C) For Clear water pump sets for 500 Lpm x 25 M head = 2 No. for B/Stn. 1 at W/W a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motorstarter, star dela, 2 No. for 500 LPM x25 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
7D) For Clear water pump sets for 500 Lpm x 30 M head = 2 No. at B/Stn. 1 a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motorstarter, star dela, 2 No. for 500 LPM x30 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
8E) For Clear water pump sets for 900 Lpm x 25 M head = 2 No. for B/Stn. 2 at W/W a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motorstarter, star dela, 2 No. for 900 LPM x25 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
9F) For Clear water pump sets for 900 Lpm x 30 M head = 2 No. at B/Stn. a) Main switch 63 Amp 2 No. ((L&T, Siemens, ABB) b) Volt meler 100 x 100mm range 0 to 500 volt 1No:(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 100 Amp 2 Nos(AE/KAPPA/L&T). d) CT 100/3 No (AE/KAPPA/L&T) e) Vss 1 no. & ASS 2 No. cach of approved make f) SPP 1 No. of approved make g) motorstarter, star dela, 2 No. for 900 LPM x30 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable 2 nos. i) Indicating Lamp-One set j) Change over switch 63 Amp = 1 No )
10Supply erection, testing of ISI marked Copper wire for 4 Nos motor with under ground system in PVC and Flexible Pipes Copper wire complete in all respects with accessories like thimble ete, complete in respects. 6 Sq mm 3 Core
1110 Sq mm 3 Core
1216Sq mm 3 Core
13Supply erection, testing of light fittings ineluding wire in the Pump Chamber with material upto 10 points including switch, button, plug. PVC conduit pipe & copper wire etc. as per approved specifications complete in respect
14Supply erection, testing of reputed make LED light 100 watts with fittings and accessories complete in respects.
15Operation and mantenence of WTP complete scope of work ( Distiction Material Supplied by the PHED) as per schedule - iv for a period of 5 year after 12 months during defect liabilityperiod and 3 months trial run period ( wil be charged to a/mtc. estimate. Complete in all respect Operation and mantenence during defect liability period ( Operation Only ) after 3 months trial run period
16For 1st Year Operation and Maintenance after defect liability period
17For 2nd Year Operation and Maintenance after defect liability period
18For 3rd Year Operation and Maintenance after defect liability period
19For 4th Year Operation and Maintenance after defect liability period
20For 5th Year Operation and Maintenance after defect liability period