Kuzhithurai Municipality Construction Of Daily Market At Karungal Road ( Ward No.20, Survey No. D12 82 ) Kuzhithurai Municipality Construction Of Daily Market At Karungal Road ( Ward No.20, Survey No. D12 82 )
Tender Overview
Project Description
Kuzhithurai Municipality Construction Of Daily Market At Karungal Road ( Ward No.20, Survey No. D12 82 ) Kuzhithurai Municipality Construction Of Daily Market At Karungal Road ( Ward No.20, Survey No. D12 82 )
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Mar-2022 | Due Date Extended | Admin Corrigendum Date Extend | 31-Mar-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Construction of daily Market |
| 2 | Earth work excavation for foundation in all kinds of soils and sub soils to full depth as directed by the departmental officers except hard rockinclusive of shoring strutting and balling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15 cm thick well rammed and consolidated and depositing the surplus earth within the compound etc.,complete as per std specifications SS 20B.- For footing |
| 3 | For grade beam |
| 4 | Supplying and filling in foundation andbasement with filling M-sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. |
| 5 | Supplying and filling the basement with Good Earth filling in layers of not more than 15cmthick well rammed watered and compacted - etc., complete complying with standard specification. |
| 6 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 7 | Supplying and erecting steel centering for sides and soffits of RCC slabs of plane surface inculding strutting upto 3.29 m height with all cross bracings using mild steelsheets of size 90cm X 60cm and 10 BGstiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c) and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and as directed by the departmental officers(Payment for centering shall be given after the concrete is laid)- Column |
| 8 | Grade beam |
| 9 | Slab |
| 10 | Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) - Below G.L |
| 11 | Above G.L |
| 12 | Supply , fabricating and placing in positionof R.T.S bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire and all labour charges etc. complete as per standard specifications. |
| 13 | Brick work in CM 1:5 (one cement & five M sand) using III class ground moulded Country bricks of size 8.75\"X41/4\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 14 | Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 15 | Plastering with cm 1:5mix (one cement and five M sand) of 12mm thick, the rate including cost of all materials and all labour charges etc. complete as per standard specifications. |
| 16 | Paving the floor with design Rajasthankotta tiles (colour and shade as directed) of size 610 mm x 610mm x 20mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification. |
| 17 | Painting two coats with approved Plastic Emulsion paint over a priming coat including thorough scrapping clean removal of dirt etccomplete and including necessary plaster of paris,putty wherever requiredetc, complete as per SS |
| 18 | Supplying and erecting pull and push type rolling shutter with I.S.I. make of approved size and section using 18 gauge G.I.sheet with manually operated type. The Shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc, complete as per standard specification.As per PWD SOR Page No 44. S.I No.132A(a) |
| 19 | Painting new iron works such as steel doors widows, ventilators with two coats of best approved first quality and colour of synthentic Enamel paint over one coat red oxide priming coat in all floors including cost of priming coat etc complete complying with standard specification. |
| 20 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 21 | Fabricating supplying and fixing of pre painted galvanized iron sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 22 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum |
| 23 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three M sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 24 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 25 | Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wallwith3 mm thick Hylum sheet cover withTW boxAnd 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good ofthe concealed portion with suitable colour for PVC concealed Light point / fan point (For electronic Regulator) SD 24 |
| 26 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush withwall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (forelectronic regulator) SD 22 |
| 27 | Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutorof 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wallwith150 mm X 100 mm X 113 mm TW switch boxwith3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plugwith continuous earth wire connection of 14 SWG TC wire for making good ofthe concealed portion with suitable colour forconcealed PVCplugpointSD 36 |
| 28 | Supply and run of 2 of 1.50 sq.mm (22/0.30) PVC insulated SC unsheathed copper Conductor of1100 V grade on 7/20GI bearer wire for service connection mains SD 64 |
| 29 | Supply and run of 2 X 1.5 sq.mm(22 / 0.30) PVC insulated SC unsheathed copper Conductor of1100 V grade in 25 mm dia GI pipe( Class \" B \" ) suitably bent at both ends with necessary angle iron upright and end supports for mains. SD 69 |
| 30 | Supply and fixing of 16 Amps DPIC Switch of 500 V with fuse and neutral (Side Handle) on suitable TW box PWD EarthingSD 141 |
| 31 | Supply and fixing of single box type 4\"-40Wflourescent tube fitting with copper choke and condenser with TWround block on wall or ceiling with flourescent tube with PVC unsheathedcopper leads from terminals to the fitting ofTube LightSD 88 |
| 32 | Supply and fixing of 1200 mm ( 48\") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mmdown rod on the existing clamp. SD 107 |
| 33 | 7.50 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 114.30mm OD x 5.40mm Thick x 4500mm Length, 88.90mm OD x 4.85mm Thick x 1500mm Length, 76.10mm OD x 3.25mm Thick x 1500mm Length. S.I no XV h page no 149 |
| 34 | LED OUTDOOR FITTINGS (LIGHT EMITTING DIODE) 120W LED Street Light Fitting with LED. S.I no 17 d page no 115 |
| 35 | LED INDOOR FITTINGS (LIGHT EMITTING DIODE)18W LED 3000K Square Type Recessed Fitting with LED |
| 36 | Providing and fixing of multivent roof ventilators (turbo ventilators) on the top of roof with high performance industrial 13 multi roof ventilator at minimum 530mm dia neck thrst at alumimium alloy to a capacity of 1850 CMA height of 25 feet including polycarbonate structure from 3mm thick sheet neck dome 1.5mm thick and required accessories as per technical specification. Multi roof ventilators to be kept approved from engineer incharge before insulation. The rates includes cutting, making holes in the existing roofing sheet. |
| 37 | Plain Cement Concrete 1:1.5:3 (one cement, one and half fine aggregates and three coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender