}

Construction Of Rural Water Supply Scheme Throuçjh Dt / Hydt / Ygpt Solar Based Ihpi2iw D.C. Motor Pump Complete Set For Different ( Olas Ot Concern Villaije Which Is Not Included In Mvs And Has No Electric Or Less Electricity To Suppyy Water 20001300, ranchi-Jharkhand

Drinking Water And Sanitation Department has published Construction Of Rural Water Supply Scheme Throuçjh Dt / Hydt / Ygpt Solar Based Ihpi2iw D.C. Motor Pump Complete Set For Different ( Olas Ot Concern Villaije Which Is Not Included In Mvs And Has No Electric Or Less Electricity To Suppyy Water 20001300. Submission Date for this Tender is 10-03-2022. Pipe Laying Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31288472
Construction Of Rural Water Supply Scheme Throuçjh Dt / Hydt / Ygpt Solar Based Ihpi2iw D.C. Motor Pump Complete Set For Different ( Olas Ot Concern Villaije Which Is Not Included In Mvs And Has No Electric Or Less Electricity To Suppyy Water 20001300
Open Tender
Indian
Jharkhand
ranchi
10-03-2022

Tender Details

Construction Of Rural Water Supply Scheme Throuçjh Dt / Hydt / Ygpt Solar Based Ihpi2iw D.C. Motor Pump Complete Set For Different ( Olas Ot Concern Villaije Which Is Not Included In Mvs And Has No Electric Or Less Electricity To Suppyy Water 200013000 Lph Maximum At Least 15130 Years For 24 X 7 Supply With 100% Cm, Erage By Tap Water Facility Under D.J.M. ( Ormanjil Block Kurujm Svs Group Of Scheme ) Kurum Svs Group Of Scheme Kurum Svs Group Of Scheme , Model- 01 ( 4000 Litre 6 M Staging ) Existing Source , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , 4000 Litre Capacityr.C.C. Water Tank ( 1.65X1.65X1.75M Internal Size ) With 6 M Staging Havingutility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil ( Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts, Levelling, Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E / I. , Providing P.C.C.M-150 In Nominal Mix Of ( 1:2:4 ) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Providing And Laying In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully / Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. ( By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted. ) , Providing And Casting In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully / Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. ( By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted ) , G.L To Above Roof Of Utility Room , Column Utility Room, Roof Beam To Tank Beam M-25 , Providing And Casting In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully / Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. ( By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted ) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully / Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. ( By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted ) ( Excluding M.S, Or Tor Reinforcement ) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof M-30 , Tank Roof Top M-25 , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials, Labours, Royalityand Taxes All Complete As Per Building Specification And Direction Of E / I. ( Mode Of Measurement-Compacted Volume ) . , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E / I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered, Rammed, Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E / I. ( Mode Of Measurement-Compacted Volume ) . , Providing Designation 75 A Brick Work In C.M ( 1:6 ) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening, Scaffolding, Raking Out Joints To 15Mm Depth, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing Designation 75A Brick Work In C.M ( 1:6 ) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening, Scaffolding, Raking Out Joints 15Mm Depth, Curing, Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E / I. , Providing R.C.C.M-200 In Nominal Mix Of ( 1:1.5:3 ) In Lintel With Approved Quality Of Stone Chips ( 20Mm To 6Mm Size ) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing ( But Excluding The Cost Of Reinforcement ) , Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of ( 1:1.5:3 ) Chhajja With Approved Quality Of Stone Chips ( 20Mm To 6Mm Size ) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position, Vibrating, Striking, 6Mm Cement Plaster ( 1:4 ) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing ( But Excluding The Cost Of Reinforcement ) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E / I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab / Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C / C ( 1:2:4 ) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E / I. , Providing 12 Mm Cement Plaster ( 1:4 ) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 12 Mm Cement Plaster ( 1:6 ) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 6 Mm Cement Plaster ( 1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 12 Mm Cement Plaster ( 1:3 ) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 19 Mm Water Proof Cement Plaster ( 1:3 ) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E / I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall, Scaffolding, Curing And Taxes All Complete As Per Building Specification & Direction Of E / I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E / I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly, Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E / I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C / C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C / C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc ( 01 Sim Each Year ) , Model-1B With Source ( Drilled T / W 125 / 115Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X50 X6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model- 04 ( 16000 Litre 12 M Staging ) , Construction Of 200Mm X165mm X120.00 M Deep High Yield Drilled Tube Well , Hydt : Cost Of Drilling 200Mmx165mmx125 Mtr Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Bore Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site. , ( A ) 0.00M Up To 50.00M Depth Below G.L. In Rural Areas , ( B ) Above 50.00 M Depth. In Rural Areas , Supplying All Tools, Tackles & Lowering Of 200 Mm Dia Ms Erw Casing Pipe Of 6Mm Wall Thickness Including Welding Charges, Cost Of Pipe Etc. All Complete Job. , Supplying All Materials, Labour, Tools & Equipments For Fitting & Fixing 200Mm Dia Ms Cap Over Casing Pipe Complete Job. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75B Designation Brick Masonry Chamber 600Mmx450mm And 750Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600Mmx475mm Rcc Cover With Earth Work In Excavation And 75Mm Thick Pcc ( 1:3:6 ) In Foundation And Refilling All Complete As Per Specification And Direction Of E / I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 2 Hp ( Dc Pump ) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Provision Of Solar Night Lamp. , 16000 Litre Capacityr.C.C. Water Tank ( 2.7X2.7X2m Internal Size ) With 12 M Staging Havingutility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil ( Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts, Levelling, Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E / I. , Providing P.C.C.M-150 In Nominal Mix Of ( 1:2:4 ) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Providing And Laying In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully / Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. ( By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted. ) , Providing And Casting In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully / Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. ( By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted ) , Column From G.L To Roof Beam Of Utility Room , Column From Roof Beam To 2Nd Bracing Beam Of Utility Room , Column From 2Nd Bracing Beam To 3Rd Bracing Beam , Column From 3Rd Bracing Beam To Tank Base , Providing And Casting In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully / Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. ( By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted ) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap / Granite / Quartzite / Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully / Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. ( By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted ) ( Excluding M.S, Or Tor Reinforcement ) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof , Tank Roof Top , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials, Labours, Royalityand Taxes All Complete As Per Building Specification And Direction Of E / I. ( Mode Of Measurement-Compacted Volume ) . , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E / I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered, Rammed, Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E / I. ( Mode Of Measurement-Compacted Volume ) . , Providing Designation 75 A Brick Work In C.M ( 1:6 ) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening, Scaffolding, Raking Out Joints To 15Mm Depth, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing Designation 75A Brick Work In C.M ( 1:6 ) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening, Scaffolding, Raking Out Joints 15Mm Depth, Curing, Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E / I. , Providing R.C.C.M-200 In Nominal Mix Of ( 1:1.5:3 ) In Lintel With Approved Quality Of Stone Chips ( 20Mm To 6Mm Size ) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing ( But Excluding The Cost Of Reinforcement ) , Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of ( 1:1.5:3 ) Chhajja With Approved Quality Of Stone Chips ( 20Mm To 6Mm Size ) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position, Vibrating, Striking, 6Mm Cement Plaster ( 1:4 ) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing ( But Excluding The Cost Of Reinforcement ) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E / I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab / Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C / C ( 1:2:4 ) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E / I. , Providing 12 Mm Cement Plaster ( 1:4 ) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 12 Mm Cement Plaster ( 1:6 ) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 6 Mm Cement Plaster ( 1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 12 Mm Cement Plaster ( 1:3 ) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 19 Mm Water Proof Cement Plaster ( 1:3 ) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water, Scaffolding, Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E / I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall, Scaffolding, Curing And Taxes All Complete As Per Building Specification & Direction Of E / I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E / I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly, Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E / I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C / C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C / C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Distribution Network & House Connection60 - 80 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 80 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 80Mm Dia. , 63Mm Dia. , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 80 Mm Hdpe Pipe , 63 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 32 Mm Dia And Weight Not Less Than 700 Gms , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5.Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanised Chain Link Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Eartrh Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing P.C.C.M-150 In Nominal Mix Of ( 1:2:4 ) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Compelete As Per Building Specification Direction Of E / I. , Labour Cost Offitting And Fixing Galvanised Chain -Link Mess Up Height Of 2 Mincluding Cost Of Staples ( But Excluding The Cost Of Cement Concrete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6 Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc.As Per Building Specification And Direction Of E / I. , Labour For Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150 Mm Compelete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Compelete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Fitted Onm.S. Angle Frame With Two Diagonals Having 25 X 25 X 5 Mm Size Angleincludingcost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In Angle Post, , Applying A Priming Red Lead Paint Over Steel Work, Taxesexcluding The Cost Of Galvanised Chain -Link Mess All Complete. , Cost Of Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Wt Not Less Than 3.1 Kg / Sq M , Cost Of 50 X 50 X 6 Mm M.S. Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Add 12 % Gst , Adding Labour Cess @ 1% Of Estimated Cost

Key Value

Document Fees
INR 10000 /-
EMD
INR 118600.0 /-
Tender Value
INR 59.29 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail