Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #31282710

PROVISION OF TECHNICAL FACILITIES FOR TELEMEDICINE AND AUDIOMETRY EQUIPMENTS ROOM IN MI ROOM AT PARUNDU AND CERTAIN SANCTIONED AND MINOR WORKS AT KATTABOMMAN AND PARUNDU 8202/E8

Issued by Statutory Bodies & Commissions/Committees · Ramanathapuram, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Mar 2022
0 days left
EMD
89000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ramanathapuram → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

PROVISION OF TECHNICAL FACILITIES FOR TELEMEDICINE AND AUDIOMETRY EQUIPMENTS ROOM IN MI ROOM AT PARUNDU AND CERTAIN SANCTIONED AND MINOR WORKS AT KATTABOMMAN AND PARUNDU 8202/E8

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Mar-2022 Amendment Other 21-Mar-2022
2 11-Mar-2022 Revised BOQ BOQ 21-Mar-2022
3 21-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-Mar-2022

BOQ

Name of Work:PROVISION OF TECHNICAL FACILITIES FOR TELEMEDICINE AND AUDIOMETRY EQUIPMENTS ROOM IN MI ROOM AT PARUNDU AND CERTAIN SANCTIONED AND MINOR WORKS AT KATTABOMMAN AND PARUNDU 8202/E8
Sl. No. Item Description
1SCHEDULE \"A\" PART-I [E/M WORKS]
2Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 4 Sqmm(nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 25mm dia (ISI marked) andaccessories, wall / surface (concealed) on ceiling with sunken type pressed steel / welded terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly for One 3/6 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
3Material and labour for Sub main wiring with PVC insulated unsheathed1100 volts FRLSgrade single core multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III)/casing capingfixed in walls (Concealed) and all accessories along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly including taking down old complete all as specified and as directed. Note: 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
4M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20 ampincluding taking down old unserviceable item complete all as specified and as directed by the Engineer-in-Charge.
5Supply and fixswitch Socketcombination 5 Amps / 16 amps, 5 in 1 flush type 240 Voltscomplete all as specified and as directed.
6Supply and fixMCB SP 5 A to 32 A, B curve, 10 kAcompleteall as specified and as directed.
7Supply and fix LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor 4 core 16 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches inpanel board, testing and commissioning etc complete all as specified and directed.
8Material and labour for Sub main wiring with PVC insulated unsheathed1100 volts FRLSgrade single core multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III)/casing capingfixed in walls (Concealed) and all accessories along with 2 run of 4 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly including taking down old complete all as specified and as directed. Note: 2 runs of 4 sqmm cable along with 2 run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
9Supply and fix surface mounted industrial socket 3 Pin 32A , IP 66/67 complete all as specified and as directed.
10Supply and fix surface mounted industrial socket 5 Pin 32A , IP 66/67complete all as specified and as directed.
11Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB with Degree of ProtectionIP 54 Suitable for MCCB\"s upto 125A as incomer complete all as specified and as directed.
12Supply and fix sheet metal enclosure powder coated double door for Distribution Board,VTPN 6 way DB with Degree of ProtectionIP 54 Suitable for MCCB\"s upto 125A as incomer complete all as specified and as directed.
13Supply and fix in repairMCB TP25A - 63 A, C curve 10 kAcompleteall as specified and as directed.
14Supply and fix in repair MCCB4 pole 415 volts, 80 Amps, with rupturing capacity 16 KA completeall as specified and as directed.
15Supply and fix in repair MCCB4 pole 415 volts, 100 Amps, with rupturing capacity 16 KA completeall as specified and as directed.
16Supply ,install and testingsplit Air conditioner of 1.5 TR capacity BEE 5 star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor ,completeall as specified and as directed. Make :VOLTAS/ BLUESTAR/CARRIER/ O GENERAL/HITACHI. Note :Rate quoted is inclusive of the following:-(i) Drain pipe UPVC with insulation from indoor unit (at any floor) to ground floor level and is to be fixed with necessary clamps complete.(ii) Drilling hole on the brick wallto facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit.(iii) Sealing the hole from outside ,after installation, with white cement.(iv) Pressure testing , cooling performance check and product demonstation.(v) 4core cable of any requiredlength for connecting indoor and outdoor unit.(vi) Material and labour for fixing Remote stand in wall.(vii) Copper pipe, 1/2\" dia and 1/4 \" dia upto 3.00 Mtr each.
17Supply and fixing of GI powder coated brackets ,for fixing of split AC\"s including grouting with suitable size fastners complete all as specified and directed.
18Supply and fixing Copper pipe 1/2\" diawith foam insulation including connecting complete all as specified and directed.
19Supply and fixing Copper pipe 1/4 \" mm diawith foam insulation including connecting complete all as specified and directed.
20Supply, Install ,testing and commisioningpump set, centrifugal, electric driven,5 HP inclusive ofjoining suction and delivery pipes to pump and foundation for pumpset complete all as specified and directed.
21Supply and Install DOL Controllerfor 5 HP Pumpset including necessary wiring to motor and connecting input power cable complete all as specified and directed.
22Supply and laying, ofgalvanised steel water tubes, medium grade 65mm bore with and includingall necessary GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/ceiling including testing complete all as specified and as directed.
23Supply and laying, ofgalvanised steel water tubes, medium grade 50mm bore with and includingall necessary GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/ceiling including testing complete all as specified and as directed.
24Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes/cables and getting out in any type ofsoil, complete all as specified
25Supply and laybricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to thelength of the brick; complete all as specified and directed.
26Demolition, Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
27M & L for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe/cable line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
28Supply and laying GI tubing Light grade of size40 mm dia bore laid in trenches / on floors / walls/ceilingfor protection of UG cable complete all as specified and as directed.
29Earthing complete with GI earth plate electrode 600 x 600 x 6.0mm buried directly in ground vertically to a depth not less than 2.25 M below GL with top edge of the earth plate not less than 1.5 M below normal GL connected with GI earth wire 4mm dia by means of bolts, nuts check nut and washers of GI and earth wire protected by GI pipe 40mm bore light grade and watering pipe 20mm bore GI pipe medium grade including one test point for testing purpose with funnel and connected to switch/control board upto 7.5m away from earth electrode including earth work, PCC (1:3:6) type C-1 chamber, RCC (1:2:4) type B-1cover slab 50mm thick with 8mm dia TMT bars reinforcement both ways at 140mm C/C, charcoal, salt, water pipe, wire mesh, lugs etc and testing complete all as applicable and as per Plate No. 3 of SSR 2009 and all as specified. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh,40mm dia light grade GI protection pipe for earth strip etc., complete.The rate quoted shall be deemed to include for Earth continuity conductor and GI protection pipe upto 7.5m.
30Supply, installation,commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz 300 Ltrs capacity complete all as specified and as directed.
31Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 300 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
32Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 240 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
33Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 185 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
34Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 150 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
35Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 70 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
36Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 50 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
37Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 35 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches inpanel board,etc, testing and commissioning cable etc complete all as specified and directed.
38Earthing complete with GI earth plate 600mmX600mm x 6 mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts and washers of GI earthingstripprotected by GI pipe i.e. light grade 40mm dia all as shown in electric plate No.5 of MES SSR Part I connected to earthing test point, testing complete including necessary earth pit PCC 1: 3: 6 chamber and 50mm thick PCC 1 : 2: 4 chamber cover and with 6mm dia mild steel re-enforcementof 10Cm C/L spacing both ways in lieu of CI cover refilling of soil ncluding taking down old complete Earthing system etc complete all as directed by Engineer-in-Charge. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth plate etc., complete
39Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a) MCCB4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 No)OUTGOING(a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 Nos) (b) MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA -(02 Nos) (c) MCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3. -01 Nos(e) LED Multifunction meter with CT - 01 No
40Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a)MCCB4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. - (01 Nos) OUTGOING(a) MCCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. -(02 Nos) (b) MCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA. - (02 Nos) (c) LED Indicating lamp RYB - Set of 3.-01 Nos(d) LED Multifunction meter with CT - 01 No
41Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a)MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. - (01 Nos) OUTGOING(a)MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. -(02 Nos) (b) MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA. As - (02 Nos) (c) LED Indicating lamp RYB - Set of 3.-01 Nos(d) LED Multifunction meter with CT - 01 No
42Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a) MCCB 4 Pole 320 Amp, 50 Hz, 415 V with rupturing capacity 50 KA - (01 Nos) OUTGOING(a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 Nos) (b) MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (04 Nos) (c) MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA as - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos(e) LED Multifunction meter with CT - 01 No
43Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING(a) MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (05 Nos) (b) MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos(e) LED Multifunction meter with CT - 01 No
44Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a)MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING(b) MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (04 Nos) (c) MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos(e) LED Multifunction meter with CT - 01 No
45Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 250 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.OUTCOMING(a) MCCB4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) (b) MCCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (04 Nos) (c)MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos(e) LED Multifunction meter with CT - 01 No
46Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 Nos) OUTGOING(b) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (c) MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) (d) MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (e) LED Indicating lamp RYB - Set of 3.-01 Nos(f) LED Multifunction meter with CT - 01 No
47Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING(b)MCCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (05 Nos) (c)MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos(e) LED Multifunction meter with CT - 01 No
48Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a)MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING(b)MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (c)MCCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) (d)MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (e) LED Indicating lamp RYB - Set of 3.-01 Nos(f) LED Multifunction meter with CT - 01 No
49Supply installation, commissioning and testing of factory made out door typeLT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitablesize includingPVC insulated and sheathed copper cable complete includingpowder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board.INCOMING(a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING(b) MCCB4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (c) MCCB4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (d) MCBTPN32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (e) LED Indicating lamp RYB - Set of 3.-01 Nos(f) LED Multifunction meter with CT - 01 No
50Taking down unserviceable ACSRConductor/ MS Channel / insulators from 9 Mtr poles of any size complete all as specified and directed.
51Excavation in trenches not exc. 1.5 m wide and not exc.1.5 m deep for laying of cable, pipe and for erecting of steel tubular swaged pole etc, and getting out in hard/dense soil complete all as specified and directed.
52Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as directeed.
53Removing excavated material not exc 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting points in soil all as directed by Engineer-in-Charge.
54Supply, spreading and compacting of riddled earthfor cable cushion on both top and bottom of cable, including ramming as specified and directed by Engineer-in-Charge.(Note :- Punned thickness only will be measured)
55Supply and layburnt bricks for cable protection of sub class \"B\" standard size in trenches all as specified.
56Supply and laying GI tubing Light grade of size100 mm dia bore laid in trenches / on floors / walls/ceilingfor protection of UG cable complete all as specified and as directed.
57Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
58Schedule of credit amount brought back from Ser Page No.34- Rs. 55,680.00 will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR

AI Tender Summary

OUR REF NO 31282710
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 28-03-2022
Authority
Authority Name Military Engineer Services
Work Description PROVISION OF TECHNICAL FACILITIES FOR TELEMEDICINE AND AUDIOMETRY EQUIPMENTS ROOM IN MI ROOM AT PARUNDU AND CERTAIN SANCTIONED AND MINOR WORKS AT KATTABOMMAN AND PARUNDU 8202/E8
Basic Detail
Tender No GE/TVL/8202
Bidding Type Tender
Location
City Ramanathapuram
State Tamil Nadu
Key Dates
Publish Date 21 Mar 2022
Submission Date 28 Mar 2022
Open Date 30 Mar 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 89000
Exemption Not Available
Document List
68349898-b240-4c0b-9aff-8109a75c0b4f.html
8202TenderDocuments.pdf
BOQ_571255.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 21, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 21, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 21, 2022
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 28, 2022
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 28, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 30, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

68349898-b240-4c0b-9aff-8109a75c0b4f.html

pdf

8202TenderDocuments.pdf

xls

BOQ_571255.xls