Construction Of Underground Utility Ducts And Redevelopment Of Residency Road At Srinagar City, srinagar-Jammu And Kashmir

Smart City Development Limited has published Construction Of Underground Utility Ducts And Redevelopment Of Residency Road At Srinagar City. Submission Date for this Tender is 09-03-2022. Duct Work Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

31268184
Corrigendum : Construction Of Underground Utility Ducts And Redevelopment Of Residency Road At Srinagar City
Open Tender
Indian
Jammu And Kashmir
srinagar
09-03-2022

Tender Details

Construction Of Underground Utility Ducts And Redevelopment Of Residency Road At Srinagar City

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2022 Amended BOQ Item Description Financial Bid 09-03-2022
2 05-Mar-2022 Corrigendum No 01 Technical Bid 09-03-2022
3 05-Mar-2022 Extension Notice No 01 Date 09-03-2022

Key Value

Document Fees
INR 20000 /-
EMD
INR 7970000.0 /-
Tender Value
INR 39.85 Crore /-

BOQ Items

Name of Work:CONSTRUCTION OF UNDERGROUND UTILITY DUCTS AND REDEVELOPMENT OF RESIDENCY ROAD AT SRINAGAR CITY
Sl. No. Item Description
1Civil Works:
2Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Char: All kinds of soil :
3Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres,
4In All kind of Soil:
5For depth from 0 to 1.50 m
6For depth from 1.50 m to 3.00 m
7For depth from 3.00 m to 4.50 m
8In Ordinary or Hard Rock
9For depth from 4.50 m to 6.00 m
10Demolishing cement concrete of all mixes manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge.
11Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material upto a lead of 1 kilometer, as per direction of Engineer-in-charge.
12Taking out existing kerb stones of all types from footpath/ central verge,including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge.
13Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge.
14Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge:
15Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads & lifts
16Disposalof bituminous waste, Lime, moorum, all sorts of rubbish upto 10 km Lead
17Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in mouldings as in cornices, windows sills etc. including setting in cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and curing but excluding the cost of reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
18Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, in all respect etc. complete: PE-100, 6 Kg/Sq. cm, Dia: 110 mm
19Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II, Dia.: 110 mm
20Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
21Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge
22Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
23Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge
24Providing and applying tack coat using bitumen emulsion conforming to IS: 8887, using emulsion pressure distributer including preparing the surface and cleaning with mechanical broom.
25Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. 40/50 mm compacted thickness with bitumen of grade VG-30 @5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in drum Type Hot Mix Plant of 60-90 TPH capacity.
26Providing and laying seal coat of premixed fine aggregate (passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface including rolling and finishing with road all complete.
27Providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/colour using hot thermoplastic material by fully/semiautomatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications
28Centering and shuttering including strutting, propping etc. and removal of form work for foundations, footings, bases for columns
29Providing and fixing G.I. pipes of medium class - B, complete with G.I. fittings excluding trenching and refilling etc. (external work)
30ND 15 mm
31ND 20 mm
32ND 25 mm
33ND 32 mm
34ND 40 mm
35Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge.
36Providing and laying in position specified grade of cement concrete excluding the cost of centering and shuttering, All work up to plinth level 1:2:4 (1cement: 2 coarse sand : 4 graded stone aggregate (20mm nominal size)
37Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4(1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
38Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of the joints except at sharp curve shall not to be more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
39Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead :With cement mortar 1:4 (1 cement : 4 fine sand)
40Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
41Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
42Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge
43Constructing brick masonry road gully chamber of specified size with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design:
44Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality. EHD 35, 560 mm internal dia.
45Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete
46250 mm dia RCC Pipe
47Constructing of RCC manhole size 1200 mm x2000 mm and upto a depth of 900 mm including 200 mm thick RCC foundation in M-20 Grade RCC over Base concrete150 mm thick in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) along with 150 mm thickRCC wallsand 150 mm thick RCC Slab inM-20 Grade of Reinforced Cement concrete as per approved Drawing.Inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, and making necessary channel/Cunnet in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design. Including providing and Fixing S.F.R.C. cover and frame (heavy duty,HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, including centering, shuttering all complete.It also inclues the safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm@300 mm C/C but excluding the excavation.
48Constructing of RCC manhole size 1200 mm x1200 mm and upto a depth of 2000 mm including 200 mm thick RCC foundation in M-20 Grade RCC over Base concrete150 mm thick in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) along with 150 mm thickRCC wallsinM-20 Grade of Reinforced Cement concrete as per approved Drawing.Inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, and making necessary channel/Cunnet in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design. Including providing and Fixing S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.It also inclues the safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm@300 mm C/C but excluding the excavation.
49Constructing of RCC manhole size 1200 mm x1200 mm and upto a depth of 3000 mm including 200 mm thick RCC foundation in M-20 Grade RCC over Base concrete150 mm thick in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) along with 150 mm thickRCC wallsinM-20 Grade of Reinforced Cement concrete as per approved Drawing.Inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, and making necessary channel/Cunnet in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design. Including providing and Fixing S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.It also inclues the safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm@300 mm C/C but excluding the excavation.
50Constructing of RCC manhole size 1200 mm x1200 mm and upto a depth of 4000 mm including 200 mm thick RCC foundation in M-20 Grade RCC over Base concrete150 mm thick in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) along with 150 mm thickRCC wallsinM-20 Grade of Reinforced Cement concrete as per approved Drawing.Inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, and making necessary channel/Cunnet in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design. Including providing and Fixing S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.It also inclues the safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm@300 mm C/C but excluding the excavation.
51Constructing of RCC manhole size 1200 mm x1200 mm and upto a depth of 5000 mm including 200 mm thick RCC foundation in M-20 Grade RCC over Base concrete150 mm thick in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) along with 150 mm thickRCC wallsinM-20 Grade of Reinforced Cement concrete as per approved Drawing.Inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, and making necessary channel/Cunnet in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design. Including providing and Fixing S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.It also inclues the safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm@300 mm C/C but excluding the excavation.
52Constructing of RCC manhole size 1200 mm x1200 mm and upto a depth of 6000 mm including 200 mm thick RCC foundation in M-20 Grade RCC over Base concrete150 mm thick in 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) along with 150 mm thickRCC wallsinM-20 Grade of Reinforced Cement concrete as per approved Drawing.Inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, and making necessary channel/Cunnet in cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design. Including providing and Fixing S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.It also inclues the safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25 mm and over all minimum length 263mm and width as 165mm@300 mm C/C but excluding the excavation.
53Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: For pipes 100 to 250 mm diameter
54Manufacturing supplying and fixing retro reflective sign boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity ncapsulated type heat activated retro reflective sheeting conforming to type-IV of ASTM-D-4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC : 67-2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminum alloy rivets @ 20cm c/c to back support frame ofM.S. angle iron of size 25x25x3mm along with theft resistant measures mounted and fixed with 2 nos. M.S. angles of size 35x35x5mm to a vertical post made upto M.S. Tee section ISMT 50x50x6mm welded with base plate of size 100x100x5mm at the bottom end and including making holes in pipes, angle flats, providing and fixing M.S. message plate of required size steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical M.S.-Tee support to be painted in black and white colours). Backside of aluminum sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coats including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge.
55Mandatory / Regulatory sign boards of 900 mm diameter with support length of 3750 mm.
56Cautionary/warning sign boards of equilateral triangular shape having each side of 900 mm support length of 3650mm.
57Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with thef resistant measures including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawing, specification and direction of Engineer-in-charge (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage.Cantiliver,Rectangulat Gantries.
58Pre-casting & Placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. pipe 40mm dia and 450mm long with 150x150x6 mm M.S. plate welded at bottom and embeded 150 mm in cement concrete 1: 3: 6 (1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing.
59Providing and fixing post delineators made of ABS round body fitted with 2nos. 100mm dia high reflective and reflectors and mounted on M.S. pipe of 65mm dia duly powder coated with anti-rust and anti-theft steel to be installed as per direction of Engineer-in-charge.
60Providing and fixing Glow studs of size 100x20mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite) or HIP (High impact Polystyrene) or ABS having electronically welded micro-prismatic lens with abrasion resistant coating as approved by Engineer-in-charge. The Glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro-reflective surface shall be 35 +/- 5 degrees to base. The reflective panels on both sides with at least 12cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS : 873 part 4 : 1973. The studs shall be fixed to the road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
61Supplying and installation of delineators (Roadway Indicators, Hazardmarkers, Object markers) 80 to 100cm high above ground level, painted black and white in 15cm widestrips, fitted with 80x100 mm rectangular or 75mmdia. Circular reflectorised panels at the top, buried or pressed into the ground and confirming to I.R.C.79 and the drawings Size: 900mm x 300mm.
62Supplying and installation Yellow and Black Rubber Rumble Strip, onRoad of material ABS with load bearing capacity of 20 - 60 Tons, size 500x125x25 mm of weigth 3.8 kg of approved make and as per direction of Engineer-in-charge.
63Supplying and installation Solar Traffic Blinker at Pedestrain crossing of 300 mm Solar Blinker, LED – 216, Solar Panel 30-Watt, Battery - 12 AH. Pole Shall be made of ERW Tubes, Swaged, welded as per IS: 2713 with ideal height of 8m and pole diameter of 210mm fixed in cement concrete foundation of 300x300x450mm in 1:2:4.
64Supplying and installation of mild steel chain link between Bollardsincluding straightening, cutting, placing in position and binding all complete as directed by Engineer incharge
65Providing and Fixing Bench 0.50 M wide x 2.0 M Long. GI Pipe (Medium) 65 mm diafor Legs fixed in cement concrete foundation of 300x300x450mm in 1:2:4, MS Plate 12 mm Thick Vertical support, MSPlate for Legs 6 mm Thick, MS Rectangular Tube (70x50x4mm) for Base support & MS Rectangular Tube (50x50x3mm) for Base. Including painting, carriages of materials, fitting, fixing, welding, taxes etc. as approved and directed by Engineer Inchage.
66Providing and Fixing Celestial Twin Bins of loading capacity 40 Lts each, Stainless Steel Waste Containers or Rigid liners as per Specifications, made from High Quality Stainless Steel, conforming to IS 12402 including fixing at site as per the direction of manufacturer and engineer in charge.
67Supplying and stacking of good earth at site including royalty (earth measured in stacks will be reduced by 20% for payment)
68Rough dressing of the trenched ground including breaking clods.
69Grassing with selection no. 1 grass including watering & maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds & fit for mowing including supplying of good earth if needed (the good earth shall be paid separately.) with grass turf
70Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 part of stacked volume of earth after reduction by 20% :1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish & surplus earth, if any with all leads & lifts (cost of sludge, manure or extra good earth, if needed, to be paid for separately)
71Holes 90 cm dia & 90 cm deep
72Holes 60 cm dia & 60 cm deep
73Providing and stacking of Pinus longifolia (Pinus)vail , Chinar, Sweet Winter, Willlow, cuprous , logas kuniya, spairiya, keras japan , forusphia, queens japan standing rose , st rose, abiliya , Hamilayan charee, serinangaof height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge.
74Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy plant in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge
75Providing and fixing M.S. flat iron tree guard 60 cm dia. and 2 m high above ground level formed of 4 nos. 25x6 mm, 2.25m long and 8 nos. 25x3 mm 2 m long vertical M.S. flats riveted to 3 nos.25x6 mm MS flat iron rings in two halves, fixed together at site with required 6 no. of 8 mm dia. and 30 mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered with the approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of the tree guard in pits of suitable dia. and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction on direction of Officer-in-charge
76Providing and fixing Precast R.C.C. grating with frame 500x450 mm horizontal grating for Avenue Plantation complete in all respect as per satisfaction on direction of Officer-in-charge
77Street Lighting
78Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation.
79Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball.
80Providing and erecting galvanised 1000mm double arm sword type bracket ( One bracket at 9 Mtr for 120 Watt Fitting and other one bracket at 6 Mtr for 28 Watt Fitting) with FRP dome and ball.
81Supplying, erecting & marking SPN MCB 6A to 32A, B- series (for lighting) in provided distribution board.
82Supplying and erecting LED street light fitting 150 W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete.
83Supplying and erecting LED street light fitting suitable above 26W to 36W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete.
84Supplying and erecting mushroom shaped integral 12W-16W LED decorative bollard upto 680mm with IP65 protection on provided foundation complete.
85Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete.
86Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia.G.l. Rod complete with all materials.
87Supplying and erecting G.I. strip of required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint in an approved manner with joint required.
88Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
89Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
90Supplying, erecting & terminating XPLE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
91Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
92Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
93Supplying, erecting & terminating XLPE armoured cable 4 core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
94Supplying, erecting & terminating XLPE armoured cable 4 core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe .
95Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places.
96Supplying & erectingG.I. pipe‘A’ class25 mmdia.erectedfor enclosingPVCarmouredcable on wall/pole.
97Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
98Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto the max load of 12 kW on provided iron frame / CC foundation complete.
99Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete.
100Supplying and erecting 20 m (clear height) High Mast (Top-150mm,Bottom- 460mm) with lowering and raising motorized unit, Vertical lantern carriage assembly suitable for max. 12 nos. luminaries and its control gear box, lightning finial arrangement for fixing aviation light and foundation bolts on provided foundation.
101Supplying and erecting Outdoor Stand Mounted Feeder Pillar for highmast of the same manufacturer with 63A TPN MCB incomer,single dial timer switch, 45A TP contactor for automatic switching of luminaries, 2 nos 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self-lock, gasket and slanting top erected with CC foundation complete.
102Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 20 m raising lowering high mast) .
103Supplying and erecting LED Flood light fitting of 200W,including lamp,with PF > 0.95,class IP 65 and above Housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete.
104Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe.
105Supplying, erecting & terminating XLPE armoured cable 3½ core120 sq. mm. aluminium conductor with continuous 12.97 sq.mm. (8 SWG) G.I. earth wire complete erected with glands & lugs,on wall/ trusses/pole or laid in provided trench/ pipe.
106Supplying and erecting Three phase smart energy meter DLMS compliance with 3x240V 50 cycles AC supply 10-60 A, ISI mark, accuracy class 1.0 with backlit LCD display, measuring & display V, I, kW, kWh, PF, kVA, kVAr, MD, day, week, month & with communication module configurable for GSM/Wi-Fi, IrDA/Bluetooth, complete provided panel with calibration certificate from manufacturer & duly wired with required size of PVC wires.
107Supplying & laying (including excavation) 25 cm Dia half round RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for enclosing provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
108Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable up to and including 16 sq. mm complete.
109Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete.
110Supplying and erecting mini feeder pillar triple pole with 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A consists of aluminium bus bar 500 V 200 A complete erected in 14 gauge CRCA sheet box with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation .
111Underground Cabling
112HT Works
113Supply, Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11kV, Single core 630 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (with Three spare cables-Total 6 Runs, One Main Circuit and One Spare Circuit) in provided cable duct bank in proper dressing of the cable in an approved maner,complete as required,as per guidelines,detailed JJKPDD Specifications and as per direction of Engineer in charge.The item includes providing of necessary clamps and hardware for Cable laying.
114Supply, Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11kV, Single core 400 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (with Three spare cables-Total 6 Runs, One Main Circuit and One Spare Circuit) in provided cable duct bank in proper dressing of the cable in an approved maner,complete as required,as per guidelines,detailed JJKPDD Specifications and as per direction of Engineer in charge.The item includes providing of necessary clamps and hardware for Cable laying.
115Supply, Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11kV, Single core 120 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (with Three spare cables-Total 6 Runs, One Main Circuit and One Spare Circuit) in provided cable duct bank in proper dressing of the cable in an approved maner,complete as required,as per guidelines,detailed JJKPDD Specifications and as per direction of Engineer in charge.The item includes providing of necessary clamps and hardware for Cable laying.
116Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Straight Through Joints : Heat Shrinkable type single core H.T. Cable straight Through Joints along with boots ( SILCAB - T) to accommodate following size of 11 KV XLPE(E) aluminium cable size 630,400 & 120 mm2 complete with all kit contents including earth continuity connection along with 3 Nos.Crimping type aluminium lugs/thimbles of suitable capacity incluiding making joints etc.in an approved manner complete as required & as per JKPDD Specification
117supply and installation of Route marker along the cable/cable duct bank in complete manner as per requirement & as per JKPDD Specification
118Supply, Laying and fixing of warning Tape in complete manner as per requirement & as per JKPDD Specification.
119Supply, Laying, Testing & Commissioning of Cable Termination Kits (indoor/outdoor) : Heat Shrinkable type ( Indoor/Outdoor) termination along with necessary accessories to accommodate for single core 630,400 & 120 mm2 ,11 Kv ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required & as per JJKPDD Specification
120Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. Pipe Earthing : Earthing With G.I. Strip,G.I.earth pipe 4.5 meter long,40mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required Complete as per JKPDD Specification
121RMU 3 WAY TYPE
122Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11 kV, 1 core (4 runs) 50 sq.mm, Al conductor,XLPE, insulated, armoured cable (from the RMU to the transformer) as per JKPDD Specification
123Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11kV, Single core 120 mm2 Aluminium round wire Armoured XLPE Cable , FRLS (with Three spare cables-Total 6 Runs) in provided cable duct bank/trench in proper dressing of the cable in an approved maner, complete as required & as per JKPDD Specification.
124Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 3 Way Out door type 11 kV,Ring Main Unit, SF6 Insulated, out-door type, Extensible type,breakingcapacity 25 KA for five seconds with SF6 circuit breaker / VCB self powered with O/C + E/F Relay comprising of a) Two (2) Nos. 11kV 630 Amp Motorised isolator including earthing Switches with making capacity 52kA, having mechanical ON/OFF, earth indications with fault current Indicator. b) One (1) Nos. 11kV ,200 Amp motorisedSpring operated, Circuit breakers with earthing switches, connecting the RMU to Supply transformer. c).Copper Bus Bar of 630 Amp rating. d). 1 No Numerical Aux. Powered relay having non directional O/C and E/F protection (for each ciruit breaker). d). The Circuit Breaker enclosures shall be outfitted with a communicable-type numerical (feeder protection) relay, i.e., one for each circuit breaker. The relay shall also interface via an RS 485 port in order to send, as a minimum, real-time phase current , readings using the MODBUS protocol. e) Incomming Isolatorhaving FPI with electrical reset Contact /facility with O/C,E/F protection. f) All necessary Potential free contacts for indications relevant to RMU monitoring and control . g) Capacitor voltage dividers serving Live-Line Cable indicators in each breaker and Isolator.CBCT with O/C,E/F relay.RMU must be SCADA enabled with interlocking arrangement between LBS and TCB. As per JJKPDD Specifications and directions of Engineer Incharge.
125Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11kV 3 phase indoor terminating kit to be used with cables - 630 Sqmm, 400 sq.mm, 120 Sqmm (Whatever Cable Size in Use) : Heat Shrinkable type (Indoor) termination along with necessary accessories to accommodate for single core 11 Kv ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required & as per JJKPDD Specification
126Supply, installation testing,and commissioning icluding labour, carriage, friegt, taxes, duties etc. of 11kV 3 phase outdoor terminating kit to be used with cables - 630 Sqmm, 400 Sq.mm, 120Sqmm (Whatever Cable Size in Use): Heat Shrinkable type (Outdoor) termination along with necessary accessories to accommodate for single core 11 Kv ( XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required & as per JJKPDD Specification
127supply and installation of Route marker along the cable/cable duct bank in complete manner as per requirement & as per JKPDD Specification
128Excavation in any type of soil including hard laterite soil as per site condition in complete manner as required & as per PWD Specification
129Refilling of excavated soil as per site condition in complete manner as required & as per PWD Specification
130Supply and filling in excavated trenches the required quantity of Sand for cushioning of the cables in the trench including labour,carriage,freight,taxes,duties etc whenever nesessary as per site condition in complete manner as required & as per JKPDD Specification
131Providing and laying . of Cement Tiles of size 300mm length x250mm width x 37mm thick as a protective cover for underground cables as per site condition in complete manner as required & as per JKPDD Specification.
132Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Earthing of RMU : Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size50 mmx6 mmfor connection of rmubodyas per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per JKPDD Specification
133Providing and laying of cement concrete. of1:2:4 (1 cement : 2 coarse sand: 4 graded aggregate 40 m nominal size for foundations) as required in complete manner & as per PWD Specification
134Providing and fixing of Centering and shuttering including struttings, propping etc and removal of formwork for civil work in complete manner as required & as per JKPDD Specification
135Cement plaster. of 15 mm cement plaster in 1:4 (1 - cement: 4 -fine sand) for foundations of RMU, complete in all respect and as per the directions of Engineer.
136Constructing masonry chamber : 600x600x900mm.inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse s&) including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23kg & weight of frame 15 kg) & RCC top slab 1:2:4 mix (1 cemenf :2 coarse s& : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine s& : 10 graded stone aggregate 40 mm nominal size) &inside plastering with cement mortar 1:3 (1 cement : 3 coarse s&) 12 mm thick, finished with a floating coat of neat cement complete as per st&ard design with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 as per JKPDD Specification.The location of each chamber will be decided by Engineer in Charge.
137Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. Foundation Work & Barricating of 3 Way RMU & Compact Substation: a) Earth work in excavation for ordinary rocky soil including disposal of excavation earth,lead up to 50 m & lift up to 1.5 m,disposed earth to be neatly dressed. b) Cement contrete 1:4:8 for foundation ,Plinth & barricating works. c) Providing & Laying in position specified grade of reinforced cement concrete,excluding the cost of centering,shuttering.finishing & reinforced work for RCC raft. d) Four Iron & Mild Steel using flats squre bars tees & channels ladders grattings framed window guards iron door openable or fixed staircase or parapet or any other type of railings gates &tree gurds etc. including cost of screws & welding fabrication work complete fixed in position. e) Providing & fixing of wire mesh jali around the RMU & CSS of size upto 8"x 4" made out of wire mesh 1"x1" squre including fixing in cement 1:2:4 including welding cutting etc. complete in all respect. f) Provision & fixing of 140 mm dia. HDPE pipes for cables alloy,etc. As per JKPDD Specification
138LT Works
139Supply, Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 630 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type(3-? ,1N and 1 Circuit spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as required & as per JKPDD Specification
140Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 400 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type(3-?, 1N and1 Circuit spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as required & as per JKPDD Specification.
141Supply,Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 185 mm² 3 1/2 Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (with 3-?, 1N and 1 Circuit spare) working voltage upto 11000 volt to be laid in cable duct complete in manner with necessary connection in an approved manner complete as required & as per JKPDD Specification.
142Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Straight Through Joints for cables. Heat Shrinkable type Straight Through Joints along with necessary accessories to accommodate for Three core 630,400 & 185 mm2 ,3 1/2 1100 Volt, XLPE(E) aliuminum cable complete with all kit contents including earth continuity of suitable capacity including making joints etc. in an approved manner complete as required & as per JKPDD Specification
143Supply, installation of Route marker along the cable/cable duct bank in complete manner as per required & as per JKPDD Specification
144Supply, Laying,fixingof warning Tape in complete manner as per required & as per JKPDD Specification
145Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Cable Termination Kits (indoor/outdoor) Heat Shrinkable type ( Indoor/Outdoor) termination along with necessary accessories to accommodate for single core 630,400 & 185 mm2 ,3 1/2 Kv. XLPE(E) aliuminum cable complete with all kit contents including earth continuity along with 3 Nos. crimping type aluminium lugs of suitable capacity including making joints etc. in an approved manner complete as required & as per JKPDD Specifications.
146Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Earthing Complete. Earthing With G.I. Strip,G.I.earth pipe 4.5 meter long,40mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required Complete as per JKPDD.
147Sub Distribution Pillar Feeder for LT Cable
148Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. 8 Way Feeder Pillar : Kiosk Boxes for Housing (MCB, 200A Busbars, Digital Energy Meters) for Distribution of Supply to consumers Complete for 8 way as per JKPDD Specification
149Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. 12 Way Feeder Pillar : 3 phase, 415V, 1 no of 250 Amps incoming 3 TP MCCBs (Breaking 50KA) fitted with outgoing 03 No 100 Amps SP MCCBs, 1No.100Amps 3 pole MCCB for outgoing LT cables, Distribution feeder Pillar suitable for outdoor installation , made out of CRCA sheet painted through 7-tank process with PU painted Busbars 4P, Aluminium with heat shrinkable sleeves and adequate capacities complete with all accesories 12 way Distribution Feeder Pillar as per JKPDD Specification
150Supply, installation and fixing of Galvanised angle frame and legs (50 mm x 50 mm x 6 mm) for Distribution Feeder Pillar , leg height 1m with 0.3m in soil approx 7 m @ 4.50Kg per mtr. as per site condition in complete manner with cutting, bending, fabrication as required in complete manner &as per JKPDD Specification
151Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of Earthing Complete Earthing With G.I. Strip,G.I.earth pipe 2.5 meter long,20mm dia including accessories & providing masonry enclosure with cover plate having locking arrangment & watering pipe etc.with charcoal & salt as required Complete as per JKPDD Specifications
152Cement grouting for support angle legs for LT fedder pillar as per approved drawing in complete manner as required & as per JKPDD Specification
153Supply, Laying, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 25/16 Sqmm (2-C) unarmoured PVC cable for service mains of Consumer as per direction given by authority in complete manner, complete as required,as per guidelines,detailed JJKPDD Specifications and as per direction of Engineer in charge.The item includes providing of necessary clamps and hardware for Cable laying.
154Compact Substation
155Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. Packaged Substation - 630kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 630kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 1000 A load break switch & 1 no. 1000A tee off with SF6circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digitalelectronic meter, C.T" etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 630 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HTside , off lead tap, oil cooled type transformer with Cu winding an st&ard fittings C) 1 No. 433V, 300A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp.each. Including 3phase 4 wire energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from MainL.T Bus bar to each compartment of MCCB so as to enable the executing agency at site forconnection with MCCB & when required. As per JKPDD Specification
156Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. Packaged Substation - 400 kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 400 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 600 A load break switch & 1 no. 600 A tee off with SF6circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digitalelectronic meter, C.T" etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 400 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HTside , off lead tap, oil cooled type transformer with Cu winding an st&ard fittings C) 1 No. 433V, 600 A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp.each. Including energy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from MainL.T Bus bar to each compartment of MCCB so as to enable the executing agency at site forconnection with MCCB & when required. As per JKPDD Specification
157Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. Packaged Substation - 100 kVA: Supply, Erection on existing C.C. foundation, Testing &Commissioning of 11kV Outdoor type Package Sub-Station consisting of 11/0.433kV, 100 kVA Oil type transformer, MV panel, LT panel inside GI sheet steel /Metallised Epoxy enclosure with interconnections, fully type tested as per the IEC-1330 complete in all respect each consisting of following items & as per detailed technical specifications: A) 3way Non - Extensible unit RMU with 2no. 200 A load break switch & 1 no. 200A tee off with SF6circuit breaker / VCB self powered with O/C + E.F. Relay, M.V Metering arrangement with digitalelectronic meter, C.T" etc. to complete as required to entire satisfaction of Engineer-in-charge. B) 1 no. 11 kV / 433V, 100 KVA three phase, DYN11, +5% to - 5% in steps of 2.5% at line end of HTside , off lead tap, oil cooled type transformer with Cu winding an st&ard fittings C) 1 No. 433V, 200A LT devices with PVC sleeved Aluminium busbars. D) One no. 4pole 1000A, 25kA MCCB with microprocessor Based Release. E) Adequate compartment to accommodate Five nos. Four Pole MCCBs of maximum capacities of 400Amp.each. Includingenergy meter F) The provision for solid connection with aluminium strips with heat shrinkable sleeves from MainL.T Bus bar to each compartment of MCCB so as to enable the executing agency at site forconnection with MCCB & when required. As per JKPDD Specification
158Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of MCCB as required for the outgoings of the existing PAC.Sub stations withnecessary arrangement as required of specifications 400 Amp., 4 pole, 433 V, 25kA, as per JKPDD Specification
159Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of MCCB as required for the outgoings of the existing PAC.Sub stations withnecessary arrangement as required of specifications 200 Amp., 4 pole, 433 V, 25kA, as per JKPDD Specification
160Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab beddingstructure for 630 KVA DT, as per JKPDD Specification
161Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab beddingstructure for 400 KVA DT, as per JKPDD Specification
162Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of prefab beddingstructure for 100 KVA DT, as per JKPDD Specification
163Supply, installation testing,and commissioning icluding labour, carriage, freight, taxes, duties etc. of 11KV Trivectormeter including all accessories like CT/PT Unit , power cables etc., as per JKPDD Specification
164Dismantling works
165Dismantling of existing ACSR 100/50 SqmmHTandtransportation back to Divisional Stores. As per Instructions of Electrical Incharge.
166Dismantling of existing ACSR 125/100 SqmmHTand Dismantling of existing transportation back to Divisional Stores. As per instruction of Electrical Incharge.
167Dismantling of existing ACSR 50/30 SqmmHTand Dismantling of existing transportation back to Divisional Stores. As per instruction of Electrical Incharge.
168Dismantling of existing MS Channel Iron 4/5 Feet long and Dismantling of existing transportation back to Divisional Stores. As per instruction of Electrical Incharge.
169Dismantling of existing 11 kV Pin Insulators complete and Dismantling of existing transportation back to Divisional Stores. As per instruction of Electrical Incharge.
170Dismantling of existing 11 Disk Set and Dismantling of existing transportation back to Divisional Stores.As per instruction of Electrical Incharge.
171Dismantling of existing ABC cable 11 KV of Sizes and Dismantling of existing transportation back to Divisional Stores. As per instruction of Electrical Incharge.
172Dismantling of existing XLPE (3-C) 11 KV and Dismantling of existing transportation back to Divisional Stores. As per instruction of Electrical Incharge.
173Dismantling of existing ST 8/9 Mtr Long Pole and transportation back to Divisional Stores. As per instruction of Electrical Incharge
174Dismantling of existing ST 8/9 Mtr (Cmposite) Long Pole and transportation back to Divisional Stores. As per instruction of Electrical Incharge.
175Dismantling of existing PCC/Wooden Poleand transportation back to Divisional Stores. As per instruction of Electrical Incharge.
176Dismantling of existing ST poleand transportation back to Divisional Stores. As per instruction of Electrical Incharge.
177Maintainance and Repairs of all the equipments and installations inluding all civil/Electricaland mechnical items for a Period of 5 years