Pre Bid Tie Up For Supply And Services Of 400 Kv Gis For Powergrid Ss02 Khavda-3 Project Pre-Bid Tie Up For Supply And Services Of 400 Kv Gis For Powergrid Ss02 Khavda-3 Project , Supply- Gis : 420Kv, 63Ka For 1S, 3150A, Sf6 Gis Auxiliary Bus Module For Spare Transformer , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Bus Reactor Feeder Bay , Supply- Gis : 400Kv, 63Ka For 1S, 4000A Gis Bus Bar Module , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Tie Bay Without Pir , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Tie Bay With Pir , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Ict Feeder Bay , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Line Feeder Bay Without Pir , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Gis Line Feeder Bay With Pir , 420Kv, 3150 A, 63 Ka, Sf6 Gis Switchable Line Reactor Bay Module Asper Section-Project, Technical Specification , Supply- Gis : 400Kv, 63Ka For 1S, 3000A, Single Phase Gas Insulated Bus Duct Outside Gis Hall , Supply- Gis : 400Kv, 63Ka For 1S, 3150A, Single Phase Sf6 To Air Bushing , Supply- Gis : 400Kv, Controlled Switching Device ( Csd ) For Gis 3-Ph Circuit Breaker , Supply- Gis : Sf6 Gas Required For Placing Gis Into Successful Operation , Supply- Gis : Structure Material Including Foundation Bolts, Embedded Items, Rails And / Or Other Materials Etc. , Supply- Gis :Earthing Materials Including High Frequency Earthing ( As Applicable ) , Supply- Gis : Tools And Tackles , 400Kv Gis-Sf6 Gas Pressure Relief Device Assembly Of Each Type , Sf6pressuregaugecumswitch / Density Monitorsandpressureswitch As Applicable, Of Each Type-400Kv Gis , Couplingdeviceforpressuregaugecumswitchforconnectinggas Handling Plant Of Each Type-400Kv Gis , Rubbergaskets, O-Ringsandsealsforsf6gasforgisenclosure Of Each Type-400Kv Gis , 400Kv Gis-Molecular Filter For Sf6 Gas With Filter Bags ( 3 % Of Totalweight ) , Control Valves For Sf6 Gas Of Each Type-400Kv Gis , Locking Device To Keep The Dis-Connectors ( Isolators ) And Earthing / Fast Earthing Switches In Close Or Open Position In Caseof Removal Of The Driving Mechanism-400Kv Gis , Uhf Pd Sensors Of Each Type Along With Bnc Connector For 420Kv Gis , 400Kv Gis-Support Insulators ( Gas Through ) Of Each Type ( Complete Withmetal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis-Gas Barriers Of Each Type ( Complete With Metal Ring Etc. ) Along With Associated Contacts And Shields , 400Kv Gis- 3150A Sf6 To Air Bushing Complete In All Respect , Lcc Spares- Aux. Relays, Contactors, Push Buttons, Switches, Lamps, Annunciation Windows, Mcb, Fuses, Timers, Terminal Blocks Etc. Of Each Type & Rating-400Kv Gis , 400Kv Gis- Complete Circuit Breaker ( 1 Phase Unit ) Of Each Type & Rating Complete With Interrupter, Main Circuit, Enclosure And Marshalling Box With Operating Mechanism ( With Pir ) To Enable Replacement Of Any Type / Rating Of Cb By Spare ( As Applicable ) , 400Kv Gis-Complete Circuit Breaker ( 1 Phase Unit ) Of Each Type & Rating Complete With Interrupter, Main Circuit, Enclosure And Marshalling Box With Operating Mechanism ( Without Pir ) To Enable Replacement Of Any Type / Rating Of Cb By Spare ( As Applicable ) , Trip Coil Assembly With Resistor For420kv Gis Circuit Breaker ( As Applicable ) , Closing Coil Assembly With Resistor For420kv Gis Circuit Breaker ( As Applicable ) , Relays, Power Contactors, Push Buttons, Timers & Mcbs Etc. ( Asapplicable ) Of Each Type For 400Kv Gis Circuit Breaker , Auxiliary Switch Assembly Of Each Type For 420Kv Gis Circuit Breaker , 400Kv Gis Circuit Breaker-Operation Counter Each Type , Windowscope / Observing Window, 3 Nos. Of Each Type , 400Kv Gis Circuit Breaker-Hydraulic Operating Mechanism With Drivemotor ( For Hydraulic Operated Mechanism, If Applicable ) , Hydraulic Filter Of Each Type ( For Hydraulic Operated Mechanism, Ifpplicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker- Hose Pipe Of Each Type ( As Applicable ) ( Forhydraulic Operated Mechanism, If Applicable ) , 400Kv Gis Circuit Breaker - N2 Accumulator ( For Hydraulic Operatedmechanism, If Applicable ) , Valves Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pipe Length ( Copper & Steel ) Of Each Size & Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , Pressure Switches Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulicoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Hydraulic Oil ( 5% Of Total Oil Quantity ) ( For Hydraulic Operated Mechanism, If Applicable ) , Pressure Relief Device Of Each Type ( For Hydraulic Operated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , Ferrules, Joints And Couplings Of Each Type ( For Hydraulic Operated Mechanism, Ifapplicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis Circuit Breaker-Complete Spring Operating Mechanismincluding Charging Mechanism Etc. ( For Spring Operated Mechanism, Ifapplicable ) , 400Kv Gis Circuit Breaker- Complete Hydraulic-Spring Operatingmechanism Including Charging Mechanism Etc. ( For Hydraulic-Springoperated Mechanism, If Applicable ) , Pressure Switches Of Each Type For420kv Giscircuit Breaker ( Forhydraulic-Spring Operated Mechanism, Ifapplicable ) , Pressure Gauge With Coupling Device Of Each Type ( For Hydraulic-Springoperated Mechanism, If Applicable ) -400Kv Gis Circuit Brekaer , 400Kv Gis- Complete Set Of Single Phase 400Kv Dis-Connector Of Each Type, Dimension, Current & Voltage Rating Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc To Enable Replacement Of Any Type / Rating Of Isolator By Spare , 400Kv Gis- 1 No. Of Single Phase Maintenance Earthing Switch Of Each Type, Dimension, Current & Voltage Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc To Enable Replacement Of Any Type / Rating Of Earth Switch By Spare , 400Kv Gis - 1 No. Of Single Phase Fast Earthing Switch Of Each Type, Dimension, Current & Voltage Rating Including Main Circuit, Enclosure, Driving Mechanism And Support Insulator Etc To Enable Replacement Of Any Type / Rating Of Earth Switch By Spare ( If Applicable ) , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Disconnectorswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Maintenance Earthswitch , Open / Close Contactor Assembly, Timers, Key Interlock, Interlockingcoils, Relays, Push Buttons, Indicating Lamps, Power Contactors, Resistors, Fuses, Mcbs & Drive Control Cards Etc. ( As Applicable ) Oneof Each Type For One Complete Mom Box For 400Kv Gis Fast Earthingswitch , Limit Switches And Aux. Switches For One Complete Mom Box Fordisconnector-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box Formaintenance Earthing Switch-400Kv Gis , Limit Switches And Aux. Switches For One Complete Mom Box For Fastearthing Switch ( If Applicable ) -400Kv Gis , Drive Mechanism For 400Kv Gis Disconnector Switch , Drive Mechanism For 400Kv Gis Maintenance Earth Switch , Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Motor For Drive Mechanism For 400Kv Gis Disconnector Switch , 400Kv Gis- Motor For Drive Mechanism For 400Kvgis Maintenance Earth Switch , 400Kv Gis- Motor For Drive Mechanism For 400Kv Gis Fast Earthing Switch , 400Kv Gis- Complete Pt Of Each Type And Rating With Enclosure To Enable Replacement Of Any Type / Rating Of Vt By Spare ( If Applicable ) , 400Kv Gis- Single Phase Vt With Associated Enclosure Complete In All Respect , Services- Gis : 400Kv, Supervision Of Erection Of Gis , Services- Gis : 400Kv, Supervision Of Erection Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Supervision Of Erection Of Sf6 To Air Bushing , Services- Gis : 400Kv, Supervision Of Erection Of Csd Complete In All Respect , Services- Gis : 400Kv, Testing & Commissioning Of Gis , Services- Gis : 400Kv, Testing & Commissioning Of Gas Insulated Bus Duct , Services- Gis : 400Kv, Testing & Commissioning Of Sf6 To Air Bushing , Services- Gis : 400Kv, Testing & Commissioning Of Csd , Services- Gis : 400Kv, Final Successful Hv / Power Frequency Testing Of Gis Including Arranging Of Hv Test Kit Along With Operator , Services- Gis : Insulation Co-Ordination Studies For Gis System , Reference Unit Price Spares- Gis : 400Kv, 63Ka For 1S, 4000A, Single Phase Bus Bar , Reference Unit Price Spares- Gis : 400Kv, Gis Metallic Enclosure , Reference Unit Price Spares- Gis : 400Kv, Expansion Bellows / Joints , Reference Unit Price Spares- Gis : 400Kv, Tee Bend , Reference Unit Price Spares- Gis : 400Kv, Angle Bend ( 135° ) , Reference Unit Price Spares- Gis : 400Kv, L-Bend , Reference Unit Price 400Kv Gis- Single Phase Of Current Transformer ( 3 Cores, Type-Cta ) With Associated Enclosure And Primary Conductor Complete In All Respect , Reference Unit Price 400Kv Gis- Single Phase Of Current Transformer ( 2 Cores, Type-Ctb ) With Associated Enclosure And Primary Conductor Complete In All Respect , Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Services For Supervision Of Erection Of Gis , Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Services For Testing & Commissioning Of Gis , Services- Gis : 400Kv, Ref. Unit Price Of Gis Individual Item / Equipment - Hiring Charges Of Hv Test Kit With Operator , Services- Gis : Training For Gis At Site , Services- Gis : Training For Gis At Manufacturer Works