Spl Repairs To Roof And False Ceiling Of Bldg No P 201 And Certain Buildings And Provn Of One Garbage Disposal Pit Near Bldg No Np 16 At Mil Stn Dhrangadhra Spl Repairs To Roof And False Ceiling Of Bldg No P 201 And Certain Buildings And Provn Of One Garb
Tender Overview
Project Description
Spl Repairs To Roof And False Ceiling Of Bldg No P 201 And Certain Buildings And Provn Of One Garbage Disposal Pit Near Bldg No Np 16 At Mil Stn Dhrangadhra Spl Repairs To Roof And False Ceiling Of Bldg No P 201 And Certain Buildings And Provn Of One Garbage Disposal Pit Near Bldg No Np 16 At Mil Stn Dhrangadhra
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for manholes, septic tanks, wells etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out Hard dense of soil complete all as specified and directed. |
| 3 | Returning, fillingin, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation complete all as specified and directed. |
| 4 | Removing excavated material to a distance exc. 1.5 Km but not exc. 5.0 KM from starting point out side MD land complete all as specified and directed. |
| 5 | M&L for providing dry river sand as in floor uondations including watering and consolidation (50 mm thick sand cushioning) complere all as specified and directed. Note : Depth after punning shall be measured and paid. |
| 6 | M&L for hard core of gauge not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, spread, levelled and rammed to a true surface including watering complete all as specified and directed. |
| 7 | M&L for plain cement concrete (1:2:4) type B-1, using 20 mm graded stone aggregate as in padding on roof using integral water proofing compound @3% by weight of cement, finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed. |
| 8 | M&L for water proofing treatment to existing non-accessible roofslabs by providing 10mm thick bedding layer of cement morter 1:3 mixed with water proofing compound as per manufacturer\"s instruction and applying one coat of bituminous/polymerized primer confirming to IS-3384 @ 0.30 Ltr/Sqm and applying of one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm and laying of actetic polypropylene (APP) modified membrane pre-fabricated, reinforced with non-woven polyester of 3.50Kg/Sqm (minimum), 3mm thick (minimum), with minimum 75mm side overlaps and 100mmend overlaps and applying one coat of bituminous aluminium paint over APP membrane complete including taking down existing water proofing treatment with bedding layer of cement mortar complete and removal of debries out side MD land all as specified and as directed. |
| 9 | M&L for plain cement concrete (1:2:4) type B-2, using 40 mm graded stone aggregate asin bed blocks complete all as specified and directed. |
| 10 | M&L for plain cement concrete (1:4:8) type D-2, as in foundation filling and mass concrete complete all as specified and directed. |
| 11 | M&L for cement concrete (1:3:6), type C-1, using 20mm graded stone aggregate in coping and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed. |
| 12 | M&L for Pre-cast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in piers caps post boundary pillars blocks etc setting 1:4 complete all as specified and directed. |
| 13 | Supply only integral water proofing compound complete all as specified and directed. |
| 14 | M&L for walling of random rubble stone masonry, uncourced, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed. |
| 15 | M&L for granite of trap stone kerb of roughly squared stones of size 20cm x 30cm, all surfaces hammer dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 20mm jointed in cement mortar 1:6 and struck flush |
| 16 | M&L for mild steelframed work such as grills, gratings, etc. with ends of bars, shouldered and/or riveted, or forged into spikes, framed guard bars etc andsimilar work conforming toFe-290 (Gde-E-165) includingframed and hung as gates, pintel hinges, stops, hand-made sliding bolts etc complete all as specified and directed. |
| 17 | S&F, mild steel, rolled sections (Fe 410-W (Gde-E-250) quality-A) as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 18 | S&F, pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 19 | S&F, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 20 | Opening the separation cracks at the junction of RCC and masonry wherever directed and instructed into \"V\" grooves 2\" to 3\" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully/carefuly schiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the coonsultant as instructed and directed. |
| 21 | Moistening the cracks, providing and priming/bonding ciat if slurry made out of \"Polyalk EP\" and cement (or equivalent as specified in the list of brand name) in proporation 1.1 to surfaces prepared as instructed and directed.Filling the cracks/Grooes by providing and applying \"Polyalk EP\" polymer modified cement mortar (or equivalent as specified in the list of brand name) in proporation 1:5:15 (Polyalk EP : Cement Graded sand/quartz sand) on the prepared surface and finishing it in level with the existing plaster including hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed. |
| 22 | Drilling holes of required size upto 16mm diameter and up to 50mm depth in concrete and cleaning the same complete all as specified and directed. |
| 23 | Providing and fixing 12mm diameter aluminium/PVC injection nipples and securing the same as directed and providing and injecting cementitious frout using CEBEX-112 additive of Posroc at off 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete all as specified and directed. |
| 24 | Providing and fixing epoxy dipped shear keys of 10mm dia and 4\" to 6\" length in columns before jacketing, Micro concreting as per consultants instructions and directions complete all as specified and directed. |
| 25 | M&L for providing mild steel bars 10mm dia and over cut to length bend to shape required including cranking, bending spirallly for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 26 | Providing and laying super fluid microconcrete roffe crete requires (or equivalent as specified in the list of brand names) in beam bottom, columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm ida or securing with clips complete all as specified and directed. |
| 27 | S&F, in repair, false ceiling, at any height, 600 x 600mm grid with Armstrong \"Prelude XL 32\" grid system and 16mm thick mineral fibre acoustic tile \"RH - 99 Classic lite\" with suspension system complete all as specified and per manufacturer\"s instruction. Make : Armstrong or equivalent as approved by GE. |
| 28 | M&L for 75mm thick cement concrete 1:3:6 type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement,complete all as specified and as directed. |
| 29 | M&L for Cement concrete Type D2 1:4:8 (40mm graded aggregate) in sub base floor complete all as specified and directed. |
| 30 | M&L for 40mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floors and fixing of glass dividing strips, finishing the surface even and smooth with using extra cement complete all as specified and directed. |
| 31 | M&L for glass dividing strips, 3mm thick, width of strip 38mm and inserted in position, conform to design complete all as specified and directed. |
| 32 | M&L for machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size conforming to IS 15658- 2006 of 60mm thickness, M-35 grade complete all as specified and directed. |
| 33 | M&L for rendering 10mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair faces of brickwork surface finished even and smooth without using extra cementcomplete all as specified and directed. |
| 34 | M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of surface finished even and smooth without using extra cementcomplete all as specified and directed. |
| 35 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface, finished even and smooth without using extra cement mixel with water proofing compound complete all as specified and directed. (Note: Water proofing compound shall be measured and paid separately). |
| 36 | M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair faces of brickwork surface finished even and smooth without using extra cementcomplete all as specified and directed. |
| 37 | Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 38 | M&L for preparing new plastered or un-plastered walls surfaces and applying three coats of white wash complete all as specified and directed. |
| 39 | M&L for preparing new plastered or un-plastered walls surfaces and applying one coat of white wash complete all as specified and directed. |
| 40 | M&L for preparing of new plastered or un-plastered surfaces and applying two coats of oil bound distemper over a coat of primer over and including wall care putty complete all as specified and directed. |
| 41 | M&L for complete removal of existing treatment and preparation of old plastered or un-plastered surfaces of walls and applying two coats of oil bond distemper over a coat of primer over and including wall care putty complete all as specified and directed. |
| 42 | M&L for preparationof new plastered surfaces of wall and applyingtwo coats of cement base paint over a coat of primer complete all as specified and directed. |
| 43 | M&L complete removal of existing treatment of wall and preparation of old plastered or un plastered surfaces of wall and applying two coats of red oxide primer complete all as specified and directed. |
| 44 | M&L for preparing new plastered or un-plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed. |
| 45 | M&L for preparing old plastered or un-plastered surfaces and applying one coats of white wash on ceilings complete all as specified and directed. |
| 46 | M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 47 | M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 48 | M&L for adquate nos of coats painting to kerb stone of pavements and the like exc 10cm wide with road marking paint, white or golden yellow complete all as specified and directed. |
| 49 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed. |
| 50 | Demolition of concrete of any description and in any position not otherwise specifically provided for such as sunken floor, roof padding etc. complete all as specified and directed. |
| 51 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 52 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender