| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches, drains, pipes and cables etc. (not exceeding 1.5mtr in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5mtr including getting out excavated soil and disposal of surplus soil as directed, within a lead of 50 mtr. All kinds of soil. |
| 2 | Providing and laying of dry stone soiling of any thickness in horizontal level, hand packed including cost of stones. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size).Nallah Stones. |
| 4 | Random Rubble masonry with hard stone from nallah in foundation and plinth including levelling up with cement concrete 1:6:12 (1 Cement: 6 coarse sand: 12 graded stone aggregate 20mm nominal size) upto plinth level with: cement mortar 1:6 (1 Cement: 6 coarse sand) |
| 5 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 course sand 4 graded stone aggregate 20mm nominal size Crushed |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutmen\"ts, posts ans sturts, etc. upto floor five level excluding cost of centring, shuttering, fmishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size. |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo Mechanically Treated Bars. |
| 8 | Centring and shuttering including strutting, propping etc. and removal of form for· Foundations: footings, bases of columns etc. for mass concrete. |
| 9 | Centring and shuttermg including strutting, propping etc. and removal of form for·Columns, Pillars, Piers, Abutments, Posts and Struts |
| 10 | Centring and shuttering including strutting, propping etc. and removal of form for: (a)Lintels, beams, plinth beams, girders, bressumers and centilevers. |
| 11 | Centring and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform. |
| 12 | Providing and fixing upto floor five level precast cement concrete solid blocks including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centring, shuttering and complete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) Crushed |
| 13 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood. |
| 14 | Providing and fixing of local ladakhi ornamental shingtsak, including polishing and complete job. |
| 15 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including lSI marked M.S. pressed Butt hinges bright finished of required size with necessary screws excluding panelling which will be paid for separately,al! complete as per direction of engineer- in charge.Second kail wood. For Door. |
| 16 | Providing and fixing glazed shutters for doors, windows- and clerestory windows using 1 Okg/sqm (4mm thick) float Rate for thickness of glass panes including lSI marked M.S. pressed butt· shutters in mm per sqm hinges bright finished of required size with necessaryscrews.First kail wood. For Window: |
| 17 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand) |
| 18 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete and lining out plaster to imitate stone or concerte blocks walling |
| 19 | Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. |
| 20 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m. |
| 21 | Providing and fixing Paraquet wooden flooring (lead made) composite size 16\" x 48\" x 12mm using 2mm thick themocole includfing cutting , placing in position all complete job as per Engineer-in-charge. |
| 22 | Providing, fixing and applying plaster of paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, -i suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab including providing and fixing expanded metal of size 5.25mmx1.25mm thickness welded to main runner and applying POP (calcium sulphate semihydrate variety)to the expanded metal of thickness not less than 1 Omm finished smooth to line and level including necessary supports scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. fiame work and suspenders complete. |
| 23 | French spirit polishing with Two or more coats on new works including a coat of wood filler: |
| 24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeNew work (two or more coats) over and in -eluding priming coat with cement primer |
| 25 | Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand . : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 50 mmthick with 20mm nominal size stone aggregate. (a) Crushed. |
| 26 | Carriage of cement and steel from an average lead up to 20 km mechanical transport. |
| 27 | Carriage of sand and coarse aggregatefrom an average lead upto 15km by mechanical transport. |
| 28 | Carriage of stones from an average lead upto 20 Km by mechanical transport. |
| 29 | Wiring for light point fan/exhaust fan/call bell point/ amp socket point with 1.5mm FR/PVC insulated copper cable in existing/recessed PVC conduit but without control/switch, without box as required. |
| 30 | Wiring for 16amp socket outlet with 2.5mm FR PVC insulated copper conductor cable in existing recessed PVC conduit including sheet as required. |
| 31 | Supplying and drawing circuit wire for light and 6/16amp switch outlet with 4.0sqmm FR PVC insulated copper conductor single core cable in the recessed/surface PVC conduit pipe and sheet as required |
| 32 | Supplying and fixing of inch 3/4 inch PVC conduit casing/capping along with accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit and sheet as required. |
| 33 | Supply and fixing of a 6 amp 240 Volt single pole grid plate mounted switch indicator with molded copper plate including recessed 2inch M.S Box complete as required including connection. |
| 34 | Supply and fixing of combined 3pin 240Volt 6amp socket outlet with safety shutter and 10amp 240Volt single pole mounted in recessed including M.S Box complete as required. |
| 35 | Supply and fixing of combined 3pin 240 Volt 16 amp socket outlet with safety shutters and 20amp 240volt single pole plate mounted switch with molded cover plate recessed including M.S Box and sheet complete as required. |
| 36 | Supply and fixing of following single pole and neutral sheet steel MCB distribution board 240volt on surface recess complete with tinned busbar neutral link earth bar, tin bar, detachable glaud plates, double door interconnected including pointing etc as required 16 way double door SPN. |
| 37 | Supply and fixing of the following light fixtures including all accessories like electronic ballasts comps etc., complete as required concealed/Tube lighting LED 15w Luminaries as per Philips. |
| 38 | Supply of 1100Volt grade aluminum conductor XPLE insulated PVC sheath arranged complete as per specification as required 50 sq mm, 3.5 core. |
| 39 | AC Stabilizer for 1.5 ton capacity working range :130-280 VAC(DigitalDisplay) Make V-GUARD, PHILIPS, or Similar range. With AC Single phase Starter switch. 11.08a to 18.0A 240V 50Hz AC C12M01 H |
| 40 | Wiring for changeover 100amp and installation with complete accessories and holes on the wall as required. |
| 41 | Supply and fixing of single telephone cord socket outlet with back lite sheet in recessed box complete as required. |
| 42 | Supply and Fixing of TV Cable R-G6 wire with cord and switch (TV/Switch) in recessed box, complete as required. |
| 43 | Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc. as required: Single Pole 6/10/20 Amp |
| 44 | Double Pole 40Amp |
| 45 | Double Pole 63Amp |
| 46 | Supply and fixing of 1.5 tonne hot and cold inverter split AC 5 star rating, 7.9amp power inut 1730 watt , 3.80w/w power of 240 v 50 Hz , of approved brand and manufacturer ( LG, SAMSUNG, PANASONIC ETC) as required. |