}

Cwe / Hsr-38 Of 2021-22 Provn Of Rcc Underground Sump, Pump House Bldg, Alogwith Pump Sets And Connected Items For Augmentation Of Water Supply System At Dhan Singh Thapa Vihar At Hisar Mil Station Provn Of Rcc Underground Sump, Pump House Bldg, Alogw, hisar-Haryana

Military Engineer Services-MES has published Cwe / Hsr-38 Of 2021-22 Provn Of Rcc Underground Sump, Pump House Bldg, Alogwith Pump Sets And Connected Items For Augmentation Of Water Supply System At Dhan Singh Thapa Vihar At Hisar Mil Station Provn Of Rcc Underground Sump, Pump House Bldg, Alogw. Submission Date for this Tender is 22-04-2022. Submersible Pump Tenders in hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

31240750
Corrigendum : Cwe / Hsr-38 Of 2021-22 Provn Of Rcc Underground Sump, Pump House Bldg, Alogwith Pump Sets And Connected Items For Augmentation Of Water Supply System At Dhan Singh Thapa Vihar At Hisar Mil Station Provn Of Rcc Underground Sump, Pump House Bldg, Alogw
Open Tender
Indian
Haryana
hisar
22-04-2022

Tender Details

Cwe / Hsr-38 Of 2021-22 Provn Of Rcc Underground Sump, Pump House Bldg, Alogwith Pump Sets And Connected Items For Augmentation Of Water Supply System At Dhan Singh Thapa Vihar At Hisar Mil Station Provn Of Rcc Underground Sump, Pump House Bldg, Alogwith Pump Sets And Connected Items For Augmentation Of Water Supply System At Dhan Singh Thapa Vihar At Hisar Mil Station

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Mar-2022 CWE/ HSR-38 OF 2021-22 Date 01-04-2022
2 24-Mar-2022 Critical Dates CWE/ HSR-38 OF 2021-22 Date 15-04-2022
3 04-Apr-2022 CWE/ HSR-38 OF 2021-22 BOQ 15-04-2022
4 15-Apr-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-04-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 76300.0 /-
Tender Value
INR 38.13 Lakhs /-

BOQ Items

Name of Work :PROVN OF RCC UNDERGROUND SUMP, PUMP HOUSE BLDG, ALOGWITH PUMP SETS AND CONNECTED ITEMS FOR AUGMENTATION OF WATER SUPPLY SYSTEM AT DHAN SINGH THAPA VIHAR AT HISAR MIL STATION
Sl. No. Item Description
1Site Clearane in Soft/ Loose Soil (for clearing bushes, vegitation, weeds etc.
2M&L for hard core of broken bricks of gauge nexc 63mm deposited and spread and levelled in layers nexc 15cm tick watered and rammed to a true surface
3M&L for PCC 1:4:8 type D2 using 40mm graded stone graded aggregate as in foundation.
4M&L for brick work with sub class B bricks ,straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified.
5M&L formwork to sides of concrete foundation footing, bases of columns & plinth beams.
6M&L formwork to sides and soffits of floors & roof, walls, beams beam haunchings, girders etc.
7M&L formwork to sides of pillars, posts, struts, columns & stanchiours etc.
8M&Lformwork to soffit of suspended slabs,such as roof slabs, floor slabs,landing and simillar work n.exc 200mm thick(Horizontal/Sloping).
9M&L RCC Design mix M25 using 20mm graded stone aggregate as in columns pillars and struts etc.
10M&L RCC Design Mix M25 using 20mm graded aggregate as in foundations, including, footings, rafts, plinth beams and mass concrete.
11M&L RCC Design Mix M25using 20mm grated stone aggregate as in beam, contilevers, lintels over 1:5m span.
12M&L RCC Design Mix M25 using 20mm graded stone aggregates as in slab.
13S&F TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified
14-do- but 8mm dia and over up to 10mm dia in stirrrups, spaeers and binders etc complete.
15–Ditto- abovebut 5 mm dia and over upto and inc. 10 mm dia in stirrups
16M&L15mm thick cement plaster on the fair face of brick or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement,all as specified .
17M&L15mm thick cement plaster on the fair face of brick or concrete surface in cement mortar 1:4 with WPC@ 200 ml per bag of cement finished even and smooth without using extra cement,all as specified . Note :- WPC shall be measured and paid separately
18Rendering 5mm thick on ceiling surfaces of brick or concrete in CM 1:3 finished even & smooth without using extra cement.
19M&L preparing new plastered surfaces of walls and applying two coat of oil bound distemperover one coat of primer complete.
20M&L preparing new plastered surfaces of walls and applying three coat of cement base paintandcomplete.
21M&L preparing new plastered surfaces of ceiling and applying three coat of white washcomplete.
22S & F for pressed steel frames of size 105 X 60 mm with one or more rebates including necessary fixing lugs/Hold Fast, hinges, locks strike plate etc(thickness ofsheet shall be 1.25mm) and making good the plaster of wall in CM 1:6.
23M&L for PCC 1:3:6 type C-1 (using 20mm Graded Stone Aggregate) as in filling of Chowkhatsand complete all as spd and directed .
24S&F Factory made 40 mm thickFlush Shutter, solid core construction with particle board care and plywood face panels commercial type on both side complete all as specified and as directed.
25S&F steel window box type with side hung shutters Factory made including box type hinges with steel handle and steel peg stay complete with glazing bars devetailed or welded.The rates include for painting with one shop coat of zinc chromate primer. Note:- Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3.
26S&F steel window box type with side hung shutters Factory made including box type hinges with steel handle and steel peg stay complete w/o glazing bars devetailed or welded. The rates include for painting with one shop coat of zinc chromate primer. Note:- Details of box type window shall be given on HQ CEJZ drawing No TD/2013/01 sheet 1/3, 2/3, 3/3.
27S & F GIwire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed in steel windows and wooden shutters.
28S&F 3 mm thick sheet glass, ordinary quality & glazing with oil putty in square n.exc 0.5 sqm each pane
29M&L Preparation of wood and wood based surfacesexceeding 10 cms width or girth and applying two coats of synthetic enamel paintoveronecoat of pink primer all as specified.
30M&L Preparation of steeland iron surfacesexceeding 10 cms width or girth and applying two coats of synthetic enamel paintoveronecoat of red oxide zinc chromeprimer, all as specified.
31S&F stainless steel butt hinges medium weight 100 mm size all as specified.
32S&F MS Sliding door bolts plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts & nuts, four on bolt plate and two on staple plate 250mm long all as specified.
33S&F Aluminium anodised, barrel tower bolts of extruded section 150mm long
34S&F Aluminium alloy handles, fabricated type, anodised 150mm size all as specified.
35Material and labour for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate, 75mm thick as in sub base cemplete all as directed and specified
36M&L for Machine cut kota stone slab flooring 18-20mm thick of size not less than 0.30 Sqm of each slab over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including 15mm thick screed bed or bedding in cement mortar 1:6 complete all as specified and directed.
37M&L for Kota stone slab 15mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in 10mm thick CM (1:3) to receive Kota Stone complete all as specified and directed
38M&L for spreading of 25mm thicklayer of sand cushioning all as specified and directed by Engr in Charge.
39M&L Machine pressed precast concrete interlocking paver block with grey cement and pigmentany shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified.
40M&L for providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerbs, Roof padding all as specified.
41M&L Screed bed or bedding layer of mortar 15mm thick in cement mortar 1:3 and finishing even and smooth with mixing of liquid WPC @200 ml per bag of cementon roof surfaces. Note : WPC shall be measured and paid seperately.
42Supply only liquid water proofing compound.
43M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3mm thick) weighing not less than 3.50Kg per Sqm, consisting of 90 micron center core HMHDPE (High molecular high density polyethylence)laid by torch application method ofoverlap 100 on length and 100mm on the width side as per manufacture"s instructions over a coatof hot air blown grade bitumen 85/25 @ 1.20Kg/Sqm over a coat of approved cold applied bituminous oil based primer (IS-3384) @ 300 gm/sqm complete and applying two coats of aluminium paint over APP membrane all as specified and directed by engineer-in-charge
44Excavation over areas not exc 1.5 mtr depth and getting out in any type of soil
45Excavation over areasexc 1.5 mtr and not exc 3mtr depth and getting out in any type of soil
46M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer-in-Charge.
47M&Lfor cement concrete M30 (Design Mix)as in foundation, including rafts, footings,foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
48M&Lfor cement concrete M30 (Design Mix)as in Walls
49M&Lfor cement concrete M30 (Design Mix)as in columns
50M&Lfor cement concrete M30 (Design Mix)as in beams
51M&Lfor cement concrete M30 (Design Mix)as in slabs
52Returning, filling in including, spreading, levelling, watering and well ramming in layers n.exc 25 cm thick soil all as specified.
53Removing of surplus excavated soilto a distanceexceeding 250 mtrs but not exc 500mtr and depositingwhere directed at a level not exc. 1.5 metreabove the starting point all as directed by Engineer-in-charge.
54M&L rendering 10mm thick in CM 1:4 on fair faces of brick or concrete surfaces using water proof compound
55M&L rendering 12mm thick in CM 1:4 on fair faces of brick or concrete surfaces using water proof compound
56M&L rendering 10mm thick in CM 1:4 on fair faces of brick or concrete surface of ceiling
57M&L Cement concrete 1:3:6 type C1 using 20mm graded stone aggregate in plinth protection, 50mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.
58Supply only water proofing compound
59S&F aluminium ladder upto 3mtr height
60Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs for manholes (square / rectangular / circular of any type and size with Angle iron bend to shape of manhole etc, shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 including necessary use and waste of formwork and demolition of existing RCC cover slabs complete (reinforcement / XPM / angle iron required to be measured separately)
61M&L 250mm dia Cast Iron pipe and bend as in vent pipe incl wire mesh fitting
62Surface excavation n.exc 30cm deep and averaging 15 cm in deep and getting out any type of soil
63M&L for 100mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate
64M&L Machine pressed precast concrete interlocking paver block with grey cement and no pigmentany shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade complete all as specified.
65M&L for PCC 1:2:4 type B0 using 20mm graded aggregates as incopings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed incl use and waste of form work.
66Supply, installing,testing and commissioning of Pumping sets, centrifugal,with electric driven Induction Motor Squirrel cage of capacity 40 HP, 3 phase, 415V,Head 35 to 40 metre, Discharge 2000-2500 LPM and of suitable rpmincluding necessary PCC foundation as recommended by OEM with antivibration Pad as required on site complete all as specified and directed.
67S&F PVC insulated multistranded Copper conductorcable of size 10 sqmm Single core, 415V complete all as specified and directed.
68Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.
69S& F automatic star delta starter with electronic timer and MNX 40 contactor for pump set as complete all as specified and directed.
70Supply, installation, commissioning and testingof feeder pillar box cubicaltype, factory made, CPRI approved ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) duly mounted on iron leg of size 50x50x6mm, Indoor type,double door,weather and vermin proof (Protection Class IP-54),with ventilation louvers and 2.0 mm thickMS CRCA sheet and angle iron frame work with both side hinged opening for external, rubber lining, locking arrangement, Powder Coated externally and internally over a coat of red oxide primer complete including grouting of frame with PCC mortor for installation of panel of following : -(For Pump House Panel) (a)Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed, capacity not lesss than 1.5 times of incomig MCCB with colour coding in separate sheet steel enclosure. (c) Panel mounted Digital Voltmeter , three phase,96mm X 96 mm square flush mounted-1 No (d) Panel mounted Digital Ammeter , three phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-1 No (e) LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos (f) MCCB415 Volts, 125 Amp, rating4 Pole,thermal adjustable type,Service Breaking Capacity 25 kA-1 No(incoming) (g) On load change over switch 100Amp ,4 pole -01 Nos (h) MCCB415 Volts, 100 Amp, rating4 Pole,thermal adjustable type,Service Breaking Capacity 25 kA-2 Nos (Out going) (h) Internal wiring with multistranded copper conductor cable/ PVC Insulated aluminium Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (j) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. (k) Automatic phase corrector and Phase preventor 380-440V, + 20 % with trip setting and time delay mode VSP- 02-1 Job. Note :-MCCBs should be connected with spreader terminalsof suitable size.
71Supply and fixing pipe ERW steel including all fittings, specials,nominal dia. 250 mm. as per IS 3589(1981) thickness 6 mm complete all as specified and directed..
72Supply, Laying, jointing and testing mild steel pipe 100 mm bore,heavy grade, ISI marked, with all fittings like sockets flanges, unions, bends, elbow etc laid in trenches or along walland in floors etc including necessary welding and fabrication works complete all as specified and as directed(Note: Excavation and earth work shall be measured and paid for separately)
73M & L for laying, jointing and testing Ductile iron (DI) Pipe 150 mm bore with spigot & socketed ends (ISI marked) centrifugally cast of class "K-9" and in any length, laid in trench including rubber gasket joints complete all as specified and directed.
74M & L for laying, jointing and testing Ductile iron (DI) Pipe 100 mm bore with spigot & socketed ends (ISI marked) centrifugally cast of class "K-9" and in any length, laid in trench including rubber gasket joints complete all as specified and directed.
75Supply, Laying, jointing and testing galvanized iron tubes 15 mm bore medium gradewith all fittings confirming toIS-1239, laid in trenches or alongwall or roofs and in floors etc complete all as specified .
76Description same as per srl item No. 5 herein before but GI tubing of size 20 mm bore.
77Supply, layingand jointing cast iron sluice valve of class PN-1.6 IS-14846 marked 150 mm bore with steel spindle, & cast iron wheel having both flanged and drilled ends including rubber gasket, nut bolt andwasher heavy duty 16mm dia etccomplete all as specified and directed.
78Description same as per srl item No. 12 herein before but of size 100 mm bore.
79Description same as per srl item No. 12 herein before butPN-1.0 of size 80 mm bore.
80M&L cast iron/DI fittings or specials for flanged / spigot socketed end pipe upto 300 mm bore conforming to IS-1538 and ISI marked such as bends , tapers, tee pieces (single & double branch) any type, and angle/radios amd Straight connecting pieces but all ends flanged complete ll as directed (joints, excavation andearth work shall be measured and paid separately)
81M&L for cutting cast iron 150 mm bore pipes for insertion of new tees, branch and reducing to required length complete all as specified (Both sides cut shall be measured as one unit) excavation andearth work shall be measured and paid separately)
82M&L for cutting cast iron 100mm bore pipes for insertion of new tees, branch and reducing to required length complete all as specified (Both sides cut shall be measured as one unit) excavation andearth work shall be measured and paid separately)
83Description same as per srl item No. 17 herein before but of size 80 mm bore.
84M&L for run lead joint for 150 mm bore cast iron pipe and fittings including material like lead, spun yarn, caulking etc complete all as specified.in new pipes / in leaking joints including dewatering the trenches/ pits where ever required
85Description same as per srl item No. 19 here-in-before butsize of CI pipe & fittings 100 mm bore.
86Description same as per srl item No. 19 here-in-before butsize of CI pipe & fittings 80 mm bore.
87Supply and fix (in repair) Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 15 mm bore fixed in repair/replacement complete.
88Description same as per srl item No. 22 herein before but GI tubing of size 20 mm bore.
89Supply, laying and joining Non return Valve of class PN-1.6, 150 mm bore having both flanged and drilled ends including rubber gasket, nut bolt and washer heavy duty 16mm dia etc complete all as specified and directed.
90Supply, laying and joining Non return Valve of class PN-1.6, 100 mm bore having both flanged and drilled ends including rubber gasket, nut bolt and washer heavy duty 16mm dia etc complete all as specified and directed.
91M&L for Cast Iron foot Valve(Flanged) with conical Strainer as in replacement Suitable for100mm dia CI/GI pipeincluding all accessories complete.
92M&L construction of brick masonry valve pit of size 1500 mmX 1500 mm X 1250mm(internal dimensions of chamber)depth to be reckoned from the top ofPCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCCfoundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified
93M&L construction of brick masonry valve pit of size 1200 mmX 1200mm X 1200mm(internal dimensions of chamber)depth to be reckoned from the top ofPCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCCfoundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified
94Material & Labour for fixing LED flood light luminaries of cap 70 watt external with lense, 240 volt,Pressure die cast housing with IP 66 protection,heat resistant toughtened clear glasswith frame complete with accessories , pre wired up to a terminal block including PVC insulated ,twin core,Aluminium conductor cable of size 1.5 sqmm and mounting attachment complete all as specified and directed.
95M&L for making good to the disturbed surfce of foot path by refixing the interlocking tiles and roundels on the path with necessry cement and PCC work complete all as specified and directed
96M&L for Point wiring with 1.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with 3 mm thick bakelite sheet top cover including 1.5 sqmm (22/.3mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified.
97All as per Sl item No 31 above herein before but one socket out let 5 pins 5 Amp on the independent board complete all as specified and directed.
98All as per Sl item No 31 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
99All as per item No.31 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLScopperearth wire for switch socket combination 3 pin 15 amps on independent board
100S&F Socket out letflush type 3/6 pinsuitablefor 15 Amp plug top Multipurpose 230 V all as specified & directed.
101S & F Socket out letflush type 5 pinsuitablefor 5 Amp 230 V all as specified & directed.
102S & F Switch Piano flush type 5 amp single Pole one way 230 V all as specified & directed.
103S & F Switch Piano flush type 15 amp single Pole one way 230 V all as specified & directed.
104S&F Lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.
105Supply and fixing LED bulb of capacity 9/10 W all as specified.
106S&F Ceiling rose surface bakelite surface 65 x 50mm, 3 terminals all as specified & directed.
107Supply & Fixing LED light fitting 18 W batten for Retro LED Energy saving tube light , high efficiency PMMA diffuser gives soft glare free light environmental friendly, energy ef?cient ready to use pack, Cat part no LHEWEBP7IN1W020 of Havells or Cat part no SLE BT 20 of Suryaor equivalent and Tube rod of 18/20W of Cat part no SLE TL-DS 18P OF SURYA all as specified and directed.
108S & F electronic ceiling fan regulator stepped typeheavy duty suitable to work on 230 volts complete all as specified.
109S & F ceiling fan of 1200mm sweep 230 V complete all as specified and directed.
110S & F MCB single pole, 240 volts, 6 Amps to 32 Amp breaking capacity 10KA(type "B")
111Supply&Fixing MCB SPN, 240 Volts, 32 Ampsbreaking capacity 10 KA (type B curve).
112S & F sheet metal enclosure MCB DBSPN 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthingcomplete all as specified and directed.
113M&L in replacement of UNSV sub main wiring with 2 single core PVC insulated unsheathed cable, 1100 V with FRLS PVC 4 sqmm copper multi stranded conductor drawn through and including ISI marked PVC conduit 25 mm dia complete, fixed on walls/ceilings with saddles as per IS including of 4 sqmm dia FRLS PVC copper cable green colour as earth wire connnected to earth all as specified and directed by Engineer-in-Charge.
114M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40 mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh, CI cover with frame, PCC chamber pit with PCC(1:3:6) type C-2 excavation and earth work all as shown in electrical plate No-3 connected to earthing test point all as all as specified & directed.
115Excavating trenches.in soft/loose soil exc. 1.5 mtrwide and not exceeding 1.5 mtr in depth forlaying of cable etc and for foundation of poles, stays etc n exc 10 Sqm on plan and n exc 1.5 in depth and getting out complete all as specified.
116Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in any type of soil after the existing water pipe lines have been taken up/out and new existing pipe line laid and tested complete all as specified and directed.
117Removal of surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from starting point complete all as specified and as directed.
118Material & Labour for sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and directed.(Note :- Punned thickness of sand will be considered for payment purpose)
119Material & Labour for bricks covering to under ground electric cable using sub class "B" bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail