Design Engineering Supply Fabr Erect Const Of Peb Shed Warehouse With Mezzanine Floor Smoke Detection Sprinkler Syst Along With Associated Allied Civil Struct Elec Instru Mech Works At Scfp Tadepalli Ap Design Engineering Supply Fabr Erect Const Of Peb Sh, Mumbai Suburban-Maharashtra

Indian Oil Corporation Limited-IOCL has published Design Engineering Supply Fabr Erect Const Of Peb Shed Warehouse With Mezzanine Floor Smoke Detection Sprinkler Syst Along With Associated Allied Civil Struct Elec Instru Mech Works At Scfp Tadepalli Ap Design Engineering Supply Fabr Erect Const Of Peb Sh. Submission Date for this Tender is 22-03-2022. PEB Tenders in Mumbai Suburban Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

31234902
Corrigendum : Design Engineering Supply Fabr Erect Const Of Peb Shed Warehouse With Mezzanine Floor Smoke Detection Sprinkler Syst Along With Associated Allied Civil Struct Elec Instru Mech Works At Scfp Tadepalli Ap Design Engineering Supply Fabr Erect Const Of Peb Sh
Open Tender
Indian
Maharashtra
Mumbai Suburban
22-03-2022

Tender Details

Design Engineering Supply Fabr Erect Const Of Peb Shed Warehouse With Mezzanine Floor Smoke Detection Sprinkler Syst Along With Associated Allied Civil Struct Elec Instru Mech Works At Scfp Tadepalli Ap Design Engineering Supply Fabr Erect Const Of Peb Shed Warehouse With Mezzanine Floor Smoke Detection Sprinkler Syst Along With Associated Allied Civil Struct Elec Instru Mech Works At Scfp Tadepalli Ap

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Mar-2022 Corrigendum 1 for Pre Bid Links for VC Other 22-03-2022

Key Value

Document Fees
Refer document
EMD
INR 549000.0 /-
Tender Value
INR 5.97 Crore /-

BOQ Items

Name of Work: Design, engineering, supply, fabrication, erection and construction of PEB (PRE-ENGINEERED BUILDING) shed / warehouse with mezzanine floor with smoke detection & Sprinkler system along with the associated allied civil, structural, electrical & instrumentation and mechanical works at SCFP Tadepalli (Andhra Pradesh)
Sl. No. Item Description
1Design, Engineering, Supply, fabrication, transporting, assembling & erecting in place, the Pre-designed, Pre-Engineered Prefab Structure including all columns, rafters, purlins, portals, trusses, beams, plates, sag rods, etc., with all primary & secondary structural members, etc complete for PEB shed having dimension of 50 M x 28 M with clear span of approx. 28 M, and catilever portion of 30 M x 5 M as per drawing. All structure to be painted with approved painting scheme as per the enclosed IOCL specifications. All fasteners to be used for fitting the roof and holding surface should be of non rusting coated. This item also includes Design, Preparation and submission of design details, detailed fabrication drawings for Pre Engineered Building. The design and drawings to be provided as per the IS norms in applicable zone and shall be finalized by IOCL/ consultant. Item also includes designing of entire structure and suitable foundation in line with enclosed specification & annexure. The job also includes providing monkey ladder in approved design, section thickness for safe access to roof. The design should be such that weather shade of effective widths & span, over openings are built within the form itself. Major Fabrication work shall be carried out at Shop/Factory. For Fabricated Plate Girder Steel Plates conform to IS 8500 Gr 540B Fe shall be used. All Rolled section shall conform to IS2062 Gr Fe 410 WA. Only connection/ fittings shall be permitted at site as directed by IOCL/ Consultant. The rate includes welding weights, site connection, nut & bolts, required dia anchor / foundation bolts with templates as per structure design and same will not be measured for payment. Only theoretical Weight of as built Structural members shall be measured for payment purpose. The rate also include vetting of complete structural design by two govt. approved structural design engineers or consultants ( preferably govt institutes like IIT / VJTI etc.) and submission of structural stability certificate as per the requirement of MIDC or IOCL. Painting scheme shall be as: a) Surface preparation by shot blasting conforming to SA 2.5 (to be done at shop) b) Prime coat of Epoxy Based Zinc Ethyle Silicate Primer (min. 60% vol. solids), one coat of 75 - 80 micron DFT. (to be done at shop c) Intermediate coat of TWO PACK EPOXY HIGH BUILD MIO COATING (min. 60% vol. solids). one coat of 100 -125 micron DFT (to be done at field after touch up primer on welded surfaces). d) Final coats ofTWO PACK ALIPHATIC ACRYLIC POLYURETHANE (min. 52% vol. solids), Two coats of combined 60 -70 micron DFT (to be done at field/Shop).Total DFT shall be 275 micron. Painting shall be done strictly as per the instruction of IOCL/CONSULTANT. Intermediate/Final Coat may be required to provide at Shop/field as directed by IOCL engineer in charge. (Rate shall include cost of supply of paint, primer, surface preparation, scaffolding all complete as per instructions of CONSULTANT/IOCL Engineer-in-Charge). Primer & paint shall be of approved make as specified by CONSULTANT/IOCL.
2Approvals for construction work Liasoning with APIIC /APCRDA and any other statutory body ( if applicable), preparation and submission of the drawings / documents, vetting of drawings / documents from Licensed Surveyor & Licensed Structural Engineer for obtaining the fire NOC, building plan approval (BPA) from APIIC for developmental work, commencement certificate, Environment Clearance, MPCB clearance, CGWA and any other statutory approval required for construction of shed and for obtaining the OC / CC ( Occupancy certificate or completion certificate ) has to be arranged by successful bidder. APIIC fee/ developmental charges or any other statutory fee shall be paid by IOCL directly against the demand letter or can be reimbursed to vendor against the actual receipts. Work under Part B and Part C has to be carryied out from the Approved Licensed Agencies of Directorate of Maharashtra Fire Services or similar Licensed Agencies for Fire services of Andhra Pradesh, having license for that work.
3Demolishing C.C. /R.C.C.work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a leadof1000m,stackingserviceableandunserviceable material separately includingcutting reinforcement bars.
4Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside site at unobjectionable place & as/direction of Engineer-in-charge.
5Demolishing stonemasonry manually/ by mechanicalmeans including stacking serviceable material & disposal of unserviceable material out of site at unobjectionable place and as per direction of Engineer-in-charge:
6Excavation & Backfilling in All Types of Ordinary soil including blackish brown clayey soil, upto 1.5 m depth below FGL/NGL: Excavation and backfilling around foundation and trenches/pits in all types of soil viz. earth, sand, gravel, clay, soft & hard murum, Asphalt, WBM etc. (excluding soft/hard rock) for footings, steps, plinth beams, equipment foundations, drains, trenches, manholes, underground tanks/pits, etc including shoring strutting, dewatering wherever required (until foundation work is complete). Item also includes carting, stacking if required, filling, Spreading, levelling and compacting / consolidating, disposal of surplus materials outside IOCL premises to an unobjectionable place following local rules or as per instructions of CONSULTANT/IOCL Engineer In Charge (Rate includes removal of any vegetation, small shrubs etc.) All Excavation Work has to be carried out Strictly as per Specification for Earthwork in Excavation.
7Excavation & Backfilling in All Types of Ordinary soil including blackish brown clayey soil, from 1.5 m to 3.0 m and more depth below FGL/NGL: Excavation and backfilling around foundation and trenches/pits in all types of soil viz. earth, sand,gravel, clay, soft & hard murum, Asphalt, WBM etc. (excluding soft/hard rock) for footings, steps, plinth beams, equipment foundations, drains, trenches, manholes, underground tanks/pits, etc including shoring strutting, dewatering wherever required (until foundation work is complete). Item also includes carting, stacking if required,filling, Spreading, levelling and compacting/ consolidating, disposal of surplus materials outside IOCL premises to an unobjectionable place following local rules or as per instructions of CONSULTANT/ IOCL Engineer In Charge (Rate includes removal of any vegetation, small shrubs etc.). All Excavation Work has to be carriedout Strictly as per Specfication for Earthwork in Excavation.
8Filling with available good excavated earth (Excavation excluded, rock excluding) Filling the sides of foundations, sub-structures, Plinth/below Grade Slab for development of plot etc. with approved quality of earth laid in layers not exceeding 300 mm in loose thickness including levelling, watering, ramming, rolling, compacting with 10-12MT mechanical roller / hand compactor/ mechanical rammer to 95% Modified Proctor Density etc as per specification in Earthwork in Filling. complete with any lead within 1 KM from IOCL premises as directed and instructed by CONSULTANT / IOCL Engineer In charge. The item includes cost of dewatering if required including payment of Royalty to Owner of borrow pit, if applicable; payment of applicable royalties, taxes, etc to Statutory Authority. All Filling Work shall be carried out Strictly as per Specification for Earthwork in Excavation.
9Filling with imported murrum in Plinth/below Grade Slab Supplying and filling with good quality of approved earth with PI (Plasticity Index) of 1 to 7 (Low plastic) containing not more than 20% cohesive fines namely clay and Max. dry density of material not less than 1.80 gm/cc below grade slab / within plinth, including identifying & locating of borrow pits, excavation at borrow pits outside Plant premises; including payment of Royalty to Owner of borrow pit, if applicable; payment of applicable royalties, taxes, etc to Statutory Authority for operating the borrow pit; loading at borrow pit end; including transportation from borrow pit to IOCL Premises; removing debris, organic matter, etc; spreading in layers not exceeding 300 mm loose depth; rolling, compacting with 10-12 MT mechanical roller / hand compactor/mechanical rammer to 95% Modified Proctor Density etc as per specification in Earthwork in Filling, dewatering during course of filling, watering, compacting the murum or sand to obtain 95% of modified proctor maximum laboratory dry density all complete as per specifications and instructions of IOCL Engineer-in-Charge. All Filling Work shall be carried out Strictly as per Specification for Earthwork in Excavation.
10Sand Filling: Supplying and filling locally available good quality river sand in trenches, pits etc and under foundations in layers of 150 mm thick including watering and compacting to achive 95 % Modified Proctor Density etc all complete as per instructions of IOCL/CONSULTANT Engineer-in-Charge.
11Anti-termite treatment "Anti termite treatment to bottom surface (in case of masonry foundation and basements) and the sides (upto a height of 300 mm from bottom) of the excavated trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration)with water by weight at the rate of 5 litres per sq.m. area. The work shall be carried out as per specification described in 6.2.1 of code IS-6313 (part - II) 1981. (Mode of measurement will be the plan area of foundation treated).
12PCC (1:4:8) Providing and laying Plain Cement Concrete of nominal volumetric mix 1:4:8 (1 Cement: 4 Sand: 8 Crushed stoneaggregates) with 40 mm and down size graded aggregates below RCC foundations and grade slab & any other work as per requirement including any required permanent brick /stone masonry including shuttering, dewatering, tamping, ramming, curing, etc with all leads & lifts and all complete as per instructions of CONSULTANT/IOCL Engineer-in- Charge. All PCC Work shall be carried out Strictly as per Specification for Plain & Reinforced Cement Concrete.
13PCC (1:3:6) Providing and laying Plain Cement Concrete of nominal volumetric mix 1:3:6 (1 Cement: 3 Sand: 6 Crushed stone aggregates) with 40 mm and down size graded aggregates below RCC foundations and grade slab & any other work as per requirement including any required permanent brick /stone masonry including shuttering, dewatering, tamping, ramming, curing, etc with all leads & lifts and all complete as per instructions of CONSULTANT/IOCL Engineer- in-Charge. All PCC Work shall be carried out Strictly as per Specification for Plain & Reinforced Cement Concrete
14PCC (1:2:4) Providing and laying Plain Cement Concrete of nominal volumetric mix 1:2:4 (1 Cement: 2 Sand: 4 Crushed stone aggregates) with 40 mm and down size graded aggregates below RCC foundations and grade slab & any other work as per requirement including any required permanent brick /stone masonry including shuttering, dewatering, tamping, ramming, curing, etc with all leads & lifts and all complete as per instructions of CONSULTANT/IOCL Engineer- in-Charge. All PCC Work shall be carried out Strictly as per Specification for Plain & Reinforced Cement Concrete.
15DPC 40 mm thick with CC 1:2:4 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement. Applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square meter on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil.
16230mm thk. Rubble Soling with manual compaction Providing, supplying and placing 230 mm thick dry rubble stone packing/soling under floor, foundation, pavement, roads, steps, ramps & other similar locations, handset vertically in rectangular lines, interstices filled in with smaller stone chips including watering, compacting/consolidating & finishing to the required levels and lines etc with manual compaction etc complete as directed by CONSULTANT/IOCL Engineer-In- Charge. (Blinding layer shall be of metal, sand or murrum supplied by contractor)
17WBM Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer
18RCC M 30 Below Plinth (Below FFL) Providing and laying in position ready mixed concrete of M30 grade, manufactured in fully automatic batching plant and transported to site of workin transit mixer for all structures, equipment foundations, columns, beams, floors, slabs, roof slabs, buildings lintels, gutters staircases, fins, chajjas, pardis, sills, copings, projections, column/ beam encasings etc. all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including thecostofcentering,shutteringfinishing but excluding the reinforcement including cost of admixtures in recommended proportions as per IS:9103toaccelerate/retardsettingofconcrete,improveworkability withoutimpairingstrengthanddurabilityasper direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 340 kg/cum.
19RCC M 30 above Plinth (Above FFL) Same as RCC M30 Below plinth but Concrete for RCC works at all levels above plinth level for all structures, equipment foundations, columns, beams, floors, slabs, roof slabs, buildings lintels, gutters staircases, fins, chajjas, pardis, sills, copings, projections, column/ beam encasings etc.(up to a ht.of 8 mts.) above plinth level.
20HYSD Bars of Grade Fe 415 /500 TMT for reinforcement Supplying and placing in position High Yield Strength deformed TMT Bars conforming to IS: 1786, Fe415/500 for beams, slabs, columns, etc at all levels and locations of RCC work with all leads & lifts. including transporting the steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per specifications, binding with Contractor"s own 16 gauge SWG binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, spacers, etc. all complete as per Bar bending schedule approved by CONSULTANT/IOCL Engineer-in-Charge. Separate measurement will be made under this item for authorised laps only as per approval of IOCL/Consultant. All Reinforcement Work shall be carriedout Strictly as per Specification for Plain & Reinforced Cement Concrete. The weight of reinforcement shall be calculated as per theoretical weight given in standard steel table and wastage/ unauthorized overlaps/binding wires shall not be payable extra.
21Providing & laying design mix cement concrete of M-30 grade, in roads driveways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as/approved & specified design criteria,providing dowel bars with sleeve/ tie bars wherever reqd, laying at site, spreading & compacting, mechanically by screed board vibrators, vacuum dewatering process and finally finished by floating,brooming with wire brush including steel form work with sturdy MS.channel sections, curing making provision for contraction / expansion, construction and longitudinal joints( 10 mm wide x 50 mm deep ) by groove cutting machine, providing and filling joints with approved joint filler and sealants,complete all as/direction of Engineer -in- Charge (Dowel & tie bars to be paid separately under reinforcement) Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess / less cement used as / design mix is payable/ recoverable separately.
22Providing & laying 80mm thick factory made Pre-cast cement concrete interlocking paver block of M 40 grade made by block making machine with strong vibratory compaction & of approved size and design/ shape shade and manufacturers and as per IOCL"s specifications. The paver block will have peripheral chamfer,with average crushing strength more than 40 N/Sq.mm as/ BS6717 Part -1(1986), maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length & width and +/- 3mm on on thickness. The job includes supplying & laying a layer of 50mm thick clean course sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand,compacting with machine vibrator to required line and level, etc. complete.(Payment for provision of edge restraints shall be made separately);- Grey or Coloured 80mm thick paver blocks
23Structural works Pipe Racks/ Pipe Supports & other Miscellaneous work: Supplying, fabricating, welding and/or bolting, as required, erecting and fixing in position all types of structural steel work viz Beams, columns ,plates, bracings shop fabricated including all accessories viz. nuts, bolts, cleats, gussets,base plate, etc as per specification complete as directed by CONSULTANT/IOCL Engineer in charge. All Plates and Rolled Section Shall conform to IS 2062 Gr Fe 410The rate to include for welding weights, site connection, nut & bolts and same will not be measured for payment. This item includes the two coat of red oxide and one coat of synthetic enamle paint. Only theoretical Weight of Structural members shall be measured for payment purpose. All Structural Work shall be carried out Strictly as per Specification for Structural Steel Work.
24Structural steel work inbuilt up sections/ framed workin gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position. All Painting Work shall be carried out preferably at Shop or as directed by IOCL Engineer in charge as per painting scheme given for above for PEB work. Final Touch up Paint may be provided at site after erection as directed by IOCL/CONSULTANT. - (Rate shall include cost of supply of paint, primer, surface preparation, scaffolding all complete as per instructions of CONSULTANT/IOCL Engineer-in-Charge). Primer & paint shall be of approved make as specified by CONSULTANT/IOCL
25230 thk Brick Masonry in CM 1:4 Supplying & constructing 230 thk brick masonary walls using bricks of first class burnt clay (class 5.0 as per IS:1077, Compressive strength of Brick 50 kg/cm2) of approved source at all locations and levels with cement mortar (1:4) including scaffolding, racking of joints, watering, but excluding cement plaster finish complete as directed and instructed by IOCL/Consultant Engineer incharge. Brickwork shall be carried out strictly as per Specification for Brick Masonry Work.
26115 thk half Brick Masonry in CM 1:4 Supplying and constructing 115mm thick burnt clay brick masonry in super structure using first class bricks (class 5.0 as per IS:1077, Compressive strength of Brick 50 kg/cm2) of approved source in cement mortar (1:4) including necessary scaffolding, racking of joints, providing horizontal reinforcement mesh comprising of ms flats of section 3X25 or ms round bars of 6 to 8mm dia in every third or fourth course to increase its lateral stability and for anchoring with load bearing wall, watering but excluding cement plaster finish complete as directed and instructed by IOCL Engineer in charge.(up to a lift of 12 mts.) Transoms & mullions shall be provided in the brick work when length or height of wall exceeds 2M. Transoms shall be provided at lintel/door height. Spacing of mullions shall not exceed 1.5M c/c. Size of transoms/ mullions shall be 115mm x 115mm with M15 grade concrete using 10mm & down graded aggregate only. Supplying and placing formwork etc for transoms/ mullions etc shall be included in the quoted rate
27Random rubble masonry below plinth Random rubble masonry with hard stone in superstructure below plinth level, including levelling up with cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20mm nominal size) with cement mortar 1:6 (1 cement: 6 sand ) as directed by IOCL/Consultant
28Random rubble masonry above plinth Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20mm nominal size) with cement mortar 1:6 (1 cement: 6 sand ) as directed by IOCL/Consultant.
29Colour Coated Profile Sheet for roofing/wall cladding Providing & fixingcolour coated Klippon Galvalume steel profilesheets(size, shape and pitch of corrugation as approved by Engineer-in-charge) ofbare metal thickness 0.50mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, with 5-7 micron epoxy primer and polyester top coat of 15-18 micron on both sides,total coated thickness(TCT) of 0.58mm.Sheet shall have protective guard film of25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6 m or as desired by Engineer-in-charge. The fixing of sheet shall be complete as per manufacturer"s specification including provision of Clip, washer, bolts, nuts, self drilling high grip screws with integral washeras necessary for fixing all complete as directed & instructed by CONSULTANT / IOCL Engineer. The item also includes supply and fixing of Polycarbonate Translucent sheet of 2 mm thk having top surface plain & bottom surface textured and profile compatible with Zincalume /galvalume sheet with all accessories. The area of Polycarbonate Translucent sheet will be approx. @ of 5% of total covered area for lighting in both roofing & Cladding in matching profile of galvalume sheet as decided by IOCL. The measurement for payment shall be only for covered area for considering Polycarbonate and Galvalume sheets (i.e. net of covered area).
30Supplying, erecting and fixing in position plain sheet 600 mm wide Colour coated galvalume ridge cap and corner flushing rolled from 0.58 mm TCT BHP Zincalume AZ-150 High tensile steel (Minimum yield strength of 275 Mpa) including fixing to Sheets stiched by(4.8 x 16 mm) Hex head stitch screws with metal bounded EPDM washers complete in all respects inclusive of cost of all labour, materials, tool, tackles etc. as per specification and direction of Site Engineer/ Engineer-in-Charge. The specification of plain sheet for Ridge shall be the same as of clip-on sheet.
31Same as above but Plain Sheet for Gutter (600 mm over all girth) with all the necessary accessories required including brackets, welding clamps, bolts, nuts galvanised iron and bituminious washers, drop ends, nozzles, stop ends etc. laid to required slopes making joints water tight, testing etc.complete as specified and directed. The specification of plain sheet for Ridge shall be the same as of clip-on sheet.
32Turbo Air Natural Ventilator at Roof : Providing & Fixing of Turbo Air Natural Roof Ventilator with 2 mm thk UV Stabilized FRP Base profile to match with Galvalume roof sheeting with adequate overlaps in all sides to avoid seepage/ leakage of water. The FRP Base of the Turbojet will be Tapering from minimum 750 to achieve 600m throat at top. The height of the Turbojet shall be about 600 mm. The ventilators shall have Vanes made out of Hi-Grade Industrial Aluminium and top plate & bottom ring of stainless steel.The turbojet shall have permanently lubricated & sealed type double bearing such as 6001ZZ of SKF and it should be maintenance free & leak proof. Turbojet shall be installed as per manufacturer specification and as directed by IOCL/CONSULTANT Engineer in charge.
33Internal Cement plaster 12mm thk. Providing & applying cement plaster in C.M. 1:4 mix to all RCC & masonry work at all levels and locations including grooves, pattas,drip moulding, scaffolding, watering, raking out joints in masonary or concrete work as per masonry & plaster specification. The rate to include providing and fixing of 200mm wide chicken wire mesh of 26G & 12mm mesh size at the junction of different construction materials. The cement used shall be Portland Pozzolana Cement (Uniform Blended Portland cement with fine pozzolana) conforming to IS:1489 Part 1 and Part 2
34Providing and applying external sand faced plaster 20mm thk consists of 12 mm thk in C.M. 1:6 first coat and 8 mm thk in CM 1 : 2 second coat to all RCC and masonry works at all locations and levels including required grain finishing, curing etc. complete as per specification and as directed and instructed by CONSULTANT / IOCL Engineer in charge. NOTE: The rates includes the cost of the base coat of not less than 12mm thk., external patta, drip moulds, curing and providing and fixing 200mm wide G.I. chicken mesh 26g thk. & 15mm mesh size at junctions of brick and RCC/PCC work etc. as well as providing and mixing waterproofing compound of approved make in both coats as per manufacturers specifications.
35Providing specified type of pointing in brick or stone masonry including curing etc. Raised and cut pointing on stone work with cement mortar 1:3 (1 cement: 3 fine sand)
36Epoxy Finished Flooring Epoxy Painting in Floor for marking as directed by IOCL/CONSULTANT Engineer in change and as per Manufacturer Specification
37Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately. For windows & ventilators with powder coated aluminium sections including providing fixing hings/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (fitting shall be paid for separately).
38Providing & Fixing Glazeing in with Toughened glass pans of 6mm thk.alluminium window EPDM rubber / new prene gaskate it is complected archti drg. And direction engg- in charage (cost of alliuminium snap bedding shall be paid in seperately.
39Rolling Shutters (Motor operated) Gear operated type-rolling shutters with gear box and crank handle at waist level on inside as well as outside Providing & fixing rolling shutter made out of 18 gauge steel sheets for laths, including bottom rail, guide channels, lock plates, locking arrangement, fixing bolts, pulling handles, hood, rolling arrangement, standard make springs in brackets, necessary bearings, etc. including fixing of frames with rag bolts, grouting of parts in position etc. and also including two coats of red oxide zinc chromate primer and two coats of synthetic enamel paint of approved colour, shade & brand etc. complete as per relevant IS standard or as per manufacturer"s requirements or as directed by IOCL. All fitted & fixed complete as per the drawings and instructions of CONSULTANT/IOCL Engineer In charge.(Measurement for the payment shall be the area of clear shutter size ). Approx. area of each Rolling shutter is 3 m x 3.5 m.
40MS grill : Supply & fixing of MS grill in 12x12 MS square bar or 25/5 flat , spacing will be 150 mm as per IOC specs including painting with one coat of synthetic enamel over one coat of primer.
41Exterior Paint: Providing and applying one coat of approved primer & two coats of Exterior Emulsion paint of Asian make (ACE Paint) or equivalent of approved shade to all external surfaces of cement plastered work or concrete including scaffolding, preparation of the surfaces as per manufacturers requirements, crack filling with approved filler material, curing etc. complete as per manufacturers specifications & as directed by CONSULTANT / IOCL Engineer in charge
42Interior Paint: Providing & applying one coat of primer, one coat of putty and three coats of acrylic Emulson paint of approved shade & make, carrying out the work as per manufacturer specification including cleaning, internal surface preparation, staging/ scaffolding etc. complete and as directed by CONSULTANT / IOCL Engineer incharge
43Design, engineering, manufacture/supply, fabrication, welding, installation, testing & commissioning of slope elevator for elevating empty containers/ buckets bags/ urea bags from ground level to the mezzanine floor as per direction of IOCL. The item rates are inclusive of provision of roller coveyor at ground floor of suitable size, belt conveyor having rough top belt-nylon impregnated PVC with moulded rubber embedded cleats or metal conveyor. Rollers shall be of SS304. This item is also inclusive of Roller lagging material, Rollers, free rollers, motors, support structure etc required at both the end. The entire structure should be of MS and to be powder painted as per the painting scheme.
44Grid False Ceiling Providing & Fixing 15mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture pintone/cosmos / Hexa or equivalent of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main "T" runner suitably spaced at joints to get required length and of size 24x38mm made from 0.33mm thick (minimum) sheet, spaced 1200mm centre to centre, and cross "T" of size 24x28mm made out of 0.33mm (Minimum) sheet, 1200mm long
45160 mm dia UPVC rain water down take pipe Providing, supplying, clamping and fixing 150mm Dia (6 kg/sqcm) UPVC rain water down take pipes from terraces to the ground level including fittings & providing of all required accessories etc complete as per drawings
46110 mm dia UPVC rain water down take pipe Same as above but 110 mm dia
47Sanitary and Water Supply Fittings Note: All catalogue nos. referred in various items of sanitary fittings are as per Hindustan Sanitary ware catalogues Water Closet---- Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat lid with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend 20mm over flow pipe with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
48Providing and fixing in position white vitreous ‘Hindustan’ Parryware or other approved make flat back urinals small size 355 x 465 large size 400 x 610 consisting of the following and inclusive of making water and drain connections. a) C.P. brass waste coupling. b) C.P. brass bottle trap with extension piece and wall flange. c) High Level 1st quality P.V.C. flushing cistern ‘Commander’ , ‘Champion’ or ‘Parryware’ ‘Slimline’ make with all accessories like C.I. or M.S. fixing brackets, overflow pipe, waste coupling, C.P. brass chain and handle, 15 dia C.P. brass angle stop cock and 10 dia C.P./P.V.C. connector pipe. d) Flush valve (push button and 0.53 GPF/2.0LPF. e) C.P. flush pipe with C.P. distribution arms and C.P. spreaders for set of one, two and three urinals. All above items are required for 1 Set of Urinal
49Partition wall between Urinals Supplying & fixing granite partition 16 mm thick between urinals.(Size 1000x600) as per direction of IOCL/CONSULTANT Engineer in charge
50SW Pipes Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : for 150 mm dia pipe.This also includes Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design for 150 mm SW Pipe
51Providing and fixing CP brass bib cock: 15 mm dia.
52Providing and fixing CP brass Stop cock : for 15 mm dia.
53Providing and fixing G.I. Pipes--25mm
54Providing and fixing G.I. Pipes---15mm
55Providing and fixing G.I. Pipes---40mm
56PIPE CONNECTION 25MM TO 40 MM
57PIPE CONNECTION 15MM TO 25 MM
58Wash Basins--460 dia circular or oval
59Toilet Paper Holder
60mirror 600x450 size
61Liquid Soap Container
62C.P. Towel Rail--20 mm dia 600 mm long
63Hand Jet Spray
64Providing and fixing in position 25 litres instant type water heater
65Towel Ring
66RO water purifier with storage of min. 5 lit water. Make Eureka forbes or Kent or equivalent.
67Water Cooler
68RCC inspection chamber size 900 x 450 and depth upto 600mm
69RCC conical manhole 1200 mm dia at bottom and 530 mm dia at top and depth of 1.5 mtr.
70Sintex or equivalent water tanks 5000 litre
71SW Trap--150 mm dia.
72Providing gola 75x75 mm in cement concrete 1:2:4
73Making khurras 45 cm x45 cm with average min thickness of 5 cm cement concrete 1:2 :4
74RCC Hume Pipes - 300 mm dia. R.C.C. pipe Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
75Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen
76Supply and fixing DB in steel sheet enclosure with 4-pole MCCB ofbreaking capacity 16 KA of 100Amp, as per specifications and direction of Engineer in Charge
77MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusiveofMCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) 4 way DB with 63A FPRCBO, 300 mA sensitivity as incoming - 1No.& 6 to 16A SP as outgoing - 4 Nos. for each phase.
78Supply & Laying horizontally and vertically of PVC/XLPE insulated cables of following sizes on cable trays, supported on steel structures, in ready made trenches and / or to pull-through pipes. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, etc, including transportation from supply store to the place of installation, unpacking and return the cable drums to site stores with all labour and materials as per the standard specifications, drawings and directions of Engineer-in-charge.
793.5 C x 95 Sq. mm, "A2XFY" cable with FRLS insulation
803.5 C x 150 Sq. mm, "A2XFY" cable with FRLS insulation
814C x 25 Sq. mm, "A2XFY" cable with FRLS insulation
824C x 16 Sq. mm, "A2XFY" cable with FRLS insulation
833C x 2.5 Sq. mm, "YWY" cable ( For Lighting Circuits) with FRLS insulation
84Power Cables: 650/1100V grade, XLPE insulated, Al/Cu. conductor armoured, extruded PVC inner sheathed & extruded FRLS PVC outer sheathed conforming to IS 7098 (Part 1). 1C x 630 sq.mm A2XWaY
85Termination of PVC/XLPE insulated cables of different sizes and connection of the Leads including supply of weather proof double compression type cable glands and tinned copper lugs, including cutting / stripping of cable insulation, fixing of cable glands, crimping of the cable cores, marking with wire number ferrules, etc., including all labour and materials, as per standard specifications and cable drums to site stores with alllabour and materials as per the standard specifications, drawings and directions of Engineerin- charge.
863 .5C x 95 Sq. mm, "A2XFY" cable
873 .5C x 150 Sq. mm, "A2XFY" cable
884C x 25 Sq. mm, "A2XFY" cable
894C x 16 Sq. mm, "A2XFY" cable
903C x 4 Sq. mm, "YWY" cable
913C x 2.5 Sq. mm, "YWY" cable
92Industrial type double compression nickel plated brass cable gland, crimping type tinned copper lugs & termination/fixing of the same including supply of crimping type tinned copper lugs & PVC/XLPE cable hoods etc for the following cable sizes. 1C X 630 A2XWaY
93PERFORATED GI CABLE TRAY Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of Engineer in charge.
94S/F/I Perforated GI trays of 150mm x 50mm x 2mm with bends, tees, cross members etc. as per
95S/F/I Perforated GI trays of 300mm x 50mm x 2mm with bends, tees, cross members etc. as per
96Supply,Installation, connection and testing of following lighting fixtures with suitable lamps and "junction box (100mmx100mm) provided for point wiring, with lamps and suitable control gear box, "including supply of all hardware like anchor fasteners, bolts, etc. required for installation, labour and "materials as per standard specifications,drawings and directions of Engineer-in-charge.
97Industrial type high bay fixture suitable 120W LED lamp with integral Diver and glass cover with IP-54 class of protection,equivalent to Bajaj Catalogue no.-BJHFL120LED, "catalogue no.-LH01-102-XXX-50-XXCrompton Catalogue no.:-LHB120CDL/60, Wipro
98Industrial type surface mounted low bay type fixture suitable 90W LED lamp with integral Driver and IP-54 class of protection,equivalent to Bajaj Catalogue no.-BJHFL80LED, Crompton Catalogue no.:-LHB90CDL/61, Wipro catalogue no.- LH01-751-XXX-50-XX
99120W LED Street light type fixture with integral driver suitable for IP-66 class of protection, equivalent to Bajaj"Catalogue no.-BRTFG120LED, Crompton Catalogue no.:-LSTN120CDL, Wipro catalogue "no.-LR02-132-XXX-57-XX
100Point wiring of the light points, ceiling fans, exhaust fans and power plug points from the lighting panels / control switch-boxes to the various light / fan / power plug points, using Medium duty 25mm dia PVC conduits and conduit fittings. Embedding the same in R.C.C. slabs, beams and walls in concealed manner, with 1100V grade FRLS type PVC insulated, colour coded, 2.5 / 4 sq.mm stranded copper conductorwires from approved makes for phase and neutral conductors and 1.5/2.5sq mm FRLS PVC Insulated copper wire forearth conductor The switch-boxes shall be embedded in wall and be made of 14SWG M.S. sheet with milky white / matching colour PVC covers with brass / rust-proof wall fixing screws, as approved by Engineer-in-charge. Switches, Setp type "Electronic fan regulator, etc., on the same phase shallbe housed in the same switch-box. Switches shall be modular Piano type and from approved makes only. The mode of mesurement of wiring to the various points will as under. Each switch / MCB and the corresponding point shall be considered as one full point. Where one switch / MCB controls more than one point, the first point from the switch / MCB shall be considered as one full point and the other points in the group shall be considered as half point each. The wiring "specified here will cover the circuits from switchbox/ lighting panel to the point outlets only.
101Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
102Switch-box (excluding the supply of switch-box and switches) -- Half points ( From switchbox to switchbox)
103Light points (with 2.5 sq.mm. cu. wire)---- Full points
104Light points (with 2.5 sq.mm. cu. wire)------Half points
1056 Amps. Plug Point(with 2.5 sq.mm. cu. wire) ---- Full points
1066 Amps. Plug Point(with 2.5 sq.mm. cu. wire) ----- Half point (installed on switchbox, etc.)
1076/16 Amps. Plug Point(with 4 sq.mm. cu. wire)---- Full points
1086/16 Amps. Plug Point(with 4 sq.mm. cu. wire) ---- Half point
10920A, 1 phase metalclad, polycarbonate body power plug point with DP ELMCB, plug and socket. The enclosure shall be 14SWG, M.S., milky white powder coated type.
110Providing earthing with 80 mm dia, 3.8 M long GI (Heavy duty) perforated pipe as per IS:3043 (with latest amendment) including providing suitable earth bus for interconnection, providing a mixture of salt & charcoal, making earth pit chamber with chequered plate cover as per standard Drwng. etc. all complete as per specif. & direction of Engineer-In-charge.
111Supply, installation, testing and commissioning of Hot Dipped G.I. (85 Micron thick) /Copper earthing loop / grid conductors of following sizes along the cable trenchs / cable trays / on the wall or structures / buried in ground (500mm depth) including excavation and back filling. Installation shall include the welding at joints and providing anti corrosive point (black butimine) at the welded portion and clamping using G.I. clamps and necessary hardware and materials as per standard drawings, specifications and directions of Engineer-in-charge.
11250 x 6 mm Hot dipped GI Strip.
11325 x 3 mm Hot Dipped G.I. Strip
1148 SWG Hot dipped G.I wire
115Supply and installation of 19 mm dia. Hot dipped G.I. (85 micron thick) lightning rod, 1200mm long, on & the highest point of the building / structure / chimney, etc., complete with all hardwares, labour and materials, as per standard drawing, specifications and directions of Engineer-in-charge
116Supply and Installation of 200x200mm Power coated LA junction box fabricated from 2.5mm thick Sheet
117Supply and installation of the following items including supply of necessary hardware, as per directions ofEngineer-in-charge.
118Shock Treatment chart complete with frame and glass
119First aid box with standard consumables inside
120Sand buckets with stand (3 nos. buckets in a stand )
121Caution board a) 415 V Grade
122Rubber hand gloves a) 415 V Grade
123Supply and laying of 900 mm wide, 6 mm thick rubber floormat.
124Supply, Installation, testing, Commissioning of 600 mm dia. 240V, 1-Ph, AC heavy duty non flameproof, air circulator fan including starter, kaul, mounting bracket and other accessories. (Suitable for wall/structure mounting type).
125Providing & fixing roof mounted solar tubular day lighting system of 750 mm dia (Tube) consisting(i) Light Collector of UV stabilized optical grade 2 mm clear transparent Polycarbonate dome with/without light management deflection panels. (ii) Factory made metal kerb with 2 seal system or UV stabilized moulded FRP roof kerb/adopter with water breaker arrangement and to be fixed onto metal sheet roof. The adoptor/kerb base should be flat, roof hugging and 100% matching with corrugation profile of base roof sheet. (iii) 1200 mm long anodised & PVD coated Light transfer tubing system of 2 mm thick (min) Aluminiumalloy sheet without joint (iv) Double glazed diffuser of UV stabilized optical grade Polycarbonate material along with injection moulded ABS plastic or FRP ring. The diffuser can also be of semi clear 2 mm (min) prismatic Polycarbonate dome shape with one side plain and surface structure on one side. The design and shape of solar light shall be as per manufacturer"s specifications and fixing of the whole system shall be completely leak proof. The solar day lighter shall provide at least 200 LUX at ground when installed at approx. 10 M height under clear sky conditions of ambient light of 1,00,000 LUX .
126Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50mm including strengthening with 2mm dia GI wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge using hot dipped galvanised wire of 4mm dia (The rate for civil works for excavation, brick masonry, PCCshall bepaid separately)
127Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer in charge.
128Supply and fixing High Density Polymer Water pipe as per IS 4984, PE-63 grade,10 Kg/sqcm rating for borewell including all fittings etc. 40mm dia HDPE pipe for borewell at a depth above 100m
129Supply Installation testing and commissioning of urea crusher machine.Horizontal Hydraulic Press with powerpack for urea breaking specification: All structure fabricated in M.S. I.S.2062 with epoxy paint . Platform 4 feet X 4 feet with SS Cladding with safety pressure switch & safety limit dispensing alarm. 25 tons hydraulic cylinders X 500mm stroke.
130Providing & fixing of ACP sheet (6 mm)in partition for control room including powder coated aluminium sections, epdm gasket etc complete. Glass sections provided (if any) shall be paid additional as applicable.
131Providing & fixing of false celling light fixture suitable 36W LED lamp with integral Diver and glass cover with IP-54 class of protection, equivalent to Bajaj Catalogue no.-BJHFL120LED, "catalogue no.-LH01-102-XXX-50-XXCrompton Catalogue no.:-LHB120CDL/60, Wipro
132Providing & fixing of false celling light fixture 6W LED lamp with integral Driver and IP-54 class of protection, equivalent to Bajaj Catalogue no.-BJHFL80LED, Crompton Catalogue no.:-LHB90CDL/61, Wipro catalogue no.- LH01-751-XXX-50-XX
133Providing and laying, fixing of vitrified floor tiles 600mmx600mm in control roomwith 20mm cement mortar at base of tiles.
134Providing and fixing of barbedwire with 600mm dia. Concentrina with all assoceries as per instructions of IOCL site incharge / IOCL Consultant.
13520 A Industrial Switch socket of approved makes
13632 A Industrial Switch socket of approved makes
137Supply, installation, testing & commissioning of Flow Switch of size : 80 mm dia (UL listed / FM approved )
138Supply & Fixing of mezzanine deck slab GI sheet of 0.8 mm thickness in mezzanine floor as per technical specification.
139Supply,erection,testing & Commissioning of submersible water pump of minimum 67 LPM 186m head (as per site requirement) with starter panel board, non return valve, gate valve etc. complete.
140Making straight through joints for medium voltage PVC armoured 1C x 630 Sq mm power cables(upto 1.1 KV grade) including cutting, stripping of cable insulation, including supply of cast resin straight through cable jointing kit of Mahindra /CCI/ approved equivalent make with ferrules. All complete with labour and materials as per drawings, specifications and directions of Engineer-in-charge
141Part B. Addressable Smoke detection with Fire alarm panel Work under Part B has to be carryied out from the Approved Licensed Agencies of Directorate of Maharashtra Fire Services or similar Licensed Agencies for Fire services of Andhra Pradesh, having license for that work.
142ADDRESSABLE 4 LOOP FIRE DETECTION ALARM PANEL - Supply, installation, testing & commissioning of Microprocessor based Intelligent and electronically addressable, modular,expandable, networkable, fire Alarm system panel for combined smoke detection system at Warehouse as well as office buildings. The panel shall have 4 loop capacity having distributed memory, the panel shall have LCD display unit, The panel shall have 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 48 hours normal working and then be capable of operating the system for 15 minutes during emergency condition, capacity to store minimum 1000 history events. Panel shall have minimum 32 bit micro-processor; each loop should support at least 99 detectors & 99 devices. (Make : Morley Honeywell, Schrack,or equivalent)
143Active Repeater -Supply, Installation, Testing and Commissioning of Active Repeaters at three positions – Location In Charge Cabin, warehouse office and Security cabin. Functions – Silence, Mute, reset, Accept, Evacuate and test controls. Should be compatible with the main Fire Alarm panel. The repeater panel shall duplicate all the audio-visual annunciations initiated at the main panel.Battery back up along with the charging facility as that of main panel shall be provided for uninterrupted operation for atleast 8 hours. (Make : Morley Honeywell, Schrack,or equivalent)
144Supply, Installation, testing & commissioning of Intelligent Analogue Addressable optical smoke Detector with floating sensitivitycomplete with all accessories like base, base box, etc. to be installed in Office, warehouse. interconnecting to loop cable complete as required. (Make : Morley Honeywell, Schrack,or equivalent)
145Multi sensor type Smoke Detectors - Supply, Installation, Testing and Commissioning of Addressable intelligent Multi sensor type smoke detectors along with mounting base for panel and electric room. (Make : Morley Honeywell, Schrack, or equivalent)
146Heat Detectors - Supply, Installation, Testing and Commissioning of Addressable Heat detectors along with mounting base for Pentry and Kitchen area. (Make : Morley Honeywell, Schrack, or equivalent)
147Supply, Installation, testing & commissioning of Intelligent Analogue Addressable optical Beam Smoke Detector with Transmitter-Receiver & Reflectorcomplete with all accessories like base, base box, etc. to be installed under / above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete as required. (Make : Morley Honeywell, Beam LRK, or equivalent)
148Supply, Installation, testing & commissioning of Analogue Addressable strobes cum hoooters (conventional hooters + control module ) (Specification :- 110 cd light & 85 dB with adjustable DB)at different locations complete with all fixing accessories, etc under false ceiling roof, wall etc. interconnecting to loop cable complete as required. (Make : Morley Honeywell, Schrack, or equivalent)
149Manual Call Points - Supply, Installation, Testing and Commissioning of addressable manual call points along with mounting back base complete with push button, enclosed in box with provision for cable or conduit coupling. The unit to be painted fire red outside, white inside. The unit shall be located near the exits/ staircase / strategic locations, should be wall mounted with break the galss/pull down cover type. The unit shall be addressable and communicate with main panel like other detectors. (Make : Morley Honeywell, Schrack, or equivalent)
150Supply, Installation, Testing and Commissioning of Addressable intelligent type fault isolator module with LED indicator for isolating shorted, de-wired and loose circuits between two successive fault isolators with auto reset arrangement.(Make : Morley Honeywell, Schrack, or equivalent)
151Response Indicators – Visual - Supply, Installation, Testing and Commissioning of visual indicators when the detector in that particular area/zone has been activated due to smoke of fire. The control room of the plant should be provided with separate visual alarm. (Make : Morley Honeywell, Schrack, or equivalent)
152Response Indicator – Audio/Hooter - Supply, Installation, Testing and Commissioning of 1 Number of Hooter/ Siren for 1 km distance to be installed at the roof top of the plant.The alarm should be of horn cum strobe type and should be intelligent addressable with main panel. (Make : Morley Honeywell, Agni, Kheraj or equivalent)
153Supply, Installation, Testing and Commissioning of Addressable Control Module. (Make : Morley Honeywell, Schrack,or equivalent)
154Supply, Installation, Testing and Commissioning of Addressable Monitor Module. (Make : Morley Honeywell, Schrack,or equivalent)
155Supply, Installation, Testing and Commissioning of LED base Emergency Exit signage with 3 hours battery backup etc. as required. (Make : ANG / Prolite / Autolite / MDS or equivalent).
156Supply and Laying (Underground/on wall mounting/depending upon the location/path) along with proper protection of 2 Core x 1.5 Sqmm copper conductor FRLS armored red color cable along with clamping or on existing cable tray with clamping wherever required.The laying also includes the civil work wherever required. (Cable Make – Polycab or equivalent)
157Part C. Automatic Sprinkler System Work under Part B has to be carryied out from the Approved Licensed Agencies of Directorate of Maharashtra Fire Services or similar Licensed Agencies for Fire services of Andhra Pradesh, having license for that work.
158Supply, cutting, welded, Installation, testing & commissioning of class ‘C’ heavy duty G Ipipe conforming to IS 1239 including fittings like internal threaded coupling suitable for sprinklers,elbows, tees, flanges, tapers, nuts bolts, gasket etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint (after applying etch primer as per specifications) of required shade of Fire Red complete as required.The item also includes fully welded 200 mm saddle/pad plate of same pipe in 1/4th perimeter at bottom over supports. Structural steel required for pipeline support or laying on wall / ceiling or columns etc shall be paid under separate item. The connection/welding job of Sprinkler system with main hydrant line will also be part of this item.
159150NB
160100NB
16180NB
16265NB
16350NB
16440NB
16532NB
16625NB
167Supply, cutting, laying GI pipe of 40mm/50 mm under Fire hydrant pipeline.
168Supply, Installation,Testing, Commissioning of Hand Wheel Operated Gate Valves rising spindle type of following sizes on the pipeline including supply and fixing 3mm thk CAF gaskets, studs/ nuts, flanges, making flanges joint etc of approved make for the following sizes as per specifications and site instructions.
169150 mm dia
170100 mm dia
171Supply, installation , testing and comissiong of 25 mm dia automatic air release valve with isolation valve, all acesories as required.
172Supply, installation testing & commissioning of 150 mm dia cast ironY Type strainer as requird.
173Supply, Installation, testing & commissioning of butterfly valve of 150 mm dia confirming to IS 13095 PN 16complete with CAF gasket, GI bolts, nuts washers etc as required.
174Supply,Installation,Testing, Commissioning of Ball valves of 25 NB on the pipeline including Supply and fixing 3mm thk CAF gaskets, studs/ nuts etc of approved make for the following sizes as per specifications and site instructions.
175Supply, Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box ball valves, MS pipe of reqd. size, flanges, orifice plate, gasket etc. of size 150 mm dia as reqd. (UL listed / FM approved )
176Supply, installation, testing & commissioning of Flow Switch of size : 150 mm dia (UL listed / FM approved )
177Supply, installation, testing & commissioning of Swing type wall mounting Fire Hose Reel conforming to IS:884 consisting of Red colour Powder coated metallic drum, 20 mm dia inlet, 20 mm dia x 30 m long high pressure nylon braided Rubber Hose Pipe as per IS: 444 or Thermoplastic Hose Pipe as per IS: 12585 with isolating valve and Brass/Bronze nozzle with chrome plated and other required accessories complete in all respect with Nuts/bolts. The make may be of NewAge, SBJ, Safegaurd etc.
178Supply, Installation, testing & commissioning of 20 mm size Pendent type sprinklers of brass/bronze with chrome plated of standard design having K-115, Quartzoid bulb of rating680 C, Quick Response (QR) with other accessories as required. The sprinklers shall be UL listed or FM approved. Sprinkler to be fitted with Teflon Tape and must be leak proof/leak tight. The make may be of NewAge, HD Fire, Spraysafe, Tyco, Viking etc The work shall be carried out in a warehouse at all heights upto 12 M.
179Supply, Installation, testing & commissioning of 15 mm size Pendent type sprinklers of brass/bronze with chrome plated of standard design having K-80, Quartzoid bulb of rating680 C, Standard Response (SR) with other accessories as required. The sprinklers shall be UL listed or FM approved. Sprinkler to be fitted with Teflon Tape and must be leak proof/leak tight. The make may be of NewAge, HD Fire, Spraysafe, Tyco, Viking etc The work shall be carried out ina warehouse at all heights upto 12 M.
180Supply, Installation, testing & commissioning of 15 mm size Sidewall type sprinklers of brass/bronze with chrome plated of standard design having K-80, Quartzoid bulb of rating680 C, Standard Response (SR) with other accessories as required. The sprinklers shall be UL listed or FM approved. Sprinkler to be fitted with Teflon Tape and must be leak proof/leak tight. The make may be of NewAge, HD Fire, Spraysafe, Tyco, Viking etc The work shall be carried out ina warehouse at all heights upto 12 M.
181Supply, Installation, testing & commissioning of UL approved S S Braided flexible drops 25 mm dia capable to with stand maximum working pressure of 175 psi with all fittings for making connection to sprinklers and with the branches.1.2 mtr length.
182Supply, Installation, testing & commissioning of S.S. Rossate plates suitable for below false ceiling sprinkler - for office area
183Supply, installation, testing and commissioning of pressure gauge of 100 mm dia , 0-21 kg/sq.cm range with15 mm dia stop cok valve, piping etc as required
184Supply, Installation, testing & commissioning of butterfly valve of 100 mm dia confirming to IS 13095 PN 16complete with CAF gasket, GI bolts, nuts washers etc as required.
185Supply, Installation, testing & commissioning of butterfly valve of 80 mm dia confirming to IS 13095 PN 16complete with CAF gasket, GI bolts, nuts washers etc as required.
186Supply, Installation, testing & commissioning of butterfly valve of 65 mm dia confirming to IS 13095 PN 16complete with CAF gasket, GI bolts, nuts washers etc as required.
187Supply, Installation, testing & commissioning of butterfly valve of 50 mm dia confirming to IS 13095 PN 16complete with CAF gasket, GI bolts, nuts washers etc as required.
188Supply, Installation, testing & commissioning of 63mm Dia. Oblique type Double headed GM Hydrantvalvewith female type instantaneous coupling includingrubber gasket, nuts, bolts, washers etc. with matching flanges asper IS 5290& as per specs.
189Supply, Installation, testing & commissioning of M.S. hoseboxes suitable for storing 2 Nos. hosesand 1 No. GMbranch pipe, hose boxes shall be made of 16 SWGM.S.sheet & duly painted with two coats ofFire red colorfrom outside &white from inside with lockingarrangement & front glass &white from inside with lockingarrangement & front doors with 6mm thick glass complete as per specifications.
190Supply, Installation, testing & commissioning of 15 mtr 63mm Dia. RRL type fire hoses as per IS 636 Type Awith female and male GM coupling.
191Providing and fixing Gun-metal 65mm dia. Short branch pipe with 20mm dia. Nozzle , ISI marked (IS:903).
192Supply, installation commissioning of water cum foam monitor with 225 LPM throw length 18-25 mtrs / 450 LPM throw length 20-28 Mtr mixing tube with control handle ISI marked (IS 2097)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail