Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi Supplying, Installation, Co

Issued by Government Departments · dhurwa, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
02 Mar 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dhurwa → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi

BOQ

Name of Work: Supplying, installation, commissioning & testing of 2 MVA outdoor type power transformer with all safety device and other standard accessories for 33/11 KV New Sub-Station under D.W. & S. Mechanical Urban Division, Ranchi.
Sl. No. Item Description
1Supply of Tubular pole of 11 Mts.as per IS 2713/80 in three sections Bottom 5.60 mts. Middle 2.7 Mts. And top 2.7 mts. Total wt. 256 Kg. as per 410-SP-57
2Supply ofof 9 Mtrs. H. Poleof weight 405 Kg.
3Supply, of 6 Mtrs. H. Pole for Post Insulators
4Supply Installation, testing & Commissioning of iron D.P. Channel with support clamp, nuts and bolts all complete.
5Supply, Installation, testing & Commissioning of ACSR Panther Conductor
6Supply Installation, testing & Commissioning of triple pole 33KV, 800 Amps out door type gang operated A.B switch triple pole (Horizontal strike) with 3 post/pin type insulator per phase mounted on provided cross arm with adequate length of G.I pipe for operating handle erected on extended square shaft the operating handle provided with lock and key at suitable height from ground with necessary clamp as per IS : 9921.
7Supplying and fitting of 33 KV outdoor type VCB:-
8Supplying, fitting & installation of 11 KV Indoor type VCB :- 11 KV 630 Amp., 25 KA Indoor type VCB suitable for control circuit voltage24 V DC, SPRING CHARGE MOTOR FOR 230V AC- 01 no., closing &Mechanism- 230 V AC single phase 50 Hz motor – 01 no., 11 KV CB with 06 nos., Insulator 01 set, panel Illumination lamp with door limit switch – 01 set, Door limit switch – 01 set, Space Heater with thermostat & switch – 01 setThermal blocks – 01 set, 13 N/o + 13 N/C Auxiliary contacts – 01 set, Thermostat setting – 01 no., Breaker control switch – 01 no., conforming to IEC 62271-100. Make – ABB/ Crompton / Schiender / Kirloskar.
9Supplying and laying 400 mm2x 3 core, 11 KV XLPE, HT aluminum cableXLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable from sub- station to 11 KV VCB panel. Make- polycab/ Havells/KEI/Anchor
10Supplying all materials, labour, tools and tackles for making Foundation for VCB and structure.
11Supplying, Installation, Testing & Commissioning of Indoor type Oil cooled, Potential Transformer Ratio: 33000/v3/110V/v3 V 3 Phase, 50 Hz, Class 1, Suitable for 33 KV Line, ISI Mark, with all labours, tools & tackles and doing all line connections etc all complete. Make: Everest or ISI Marked.
12Cost towards Supplying Installation Testing & Commissioning of Indoor type Oil cooled , Current Transformer Ratio: 150/1-1 Amp. 3 Phase, 50 Hz, Class 1, Suitable for 33 KV Line, ISI Mark, with all labours, tools & tackles and doing all line connections etc all complete. Make - Everest or ISI Marked.
13Cost towards Supply, installation & testing of D.O fuse for 33KV system (1 set = 3Nos.).
14Supplying, Installation, Testing & Commissioningof 33 KV Lightening Arrester Metal Oxide type.
15Supplying, Installation, Testing & Commissioning of all required material for Maintenance free chemical earthing including with all accessories & earth cone & connected with accessories for HT equipment’s in substation area.
16Supplying, Installation, Testing & Commissioning of Connectors of Different Types and Sizes as per the requirement of site conditions.
17Supplying & laying copper conductor PVC Control Cable Size : 29 Core x 2.5 Sq.mm. Make- Havells/Polycab/KEI
18Supply, Installation, Testing & Commissioning of 33 KV disc insulator complete with all fasteners and Hardware for Panther Conductor. (1 Set = 3 Nos.)
19Supply, Installation, Testing & Commissioning of 33 KV pin insulator complete with pin & fasteners
20Supply, Installation, Testing & Commissioning of Cross Bracing with Clamp and Nuts &Bolts all complete
21Supply, Installation, Testing & Commissioning of 33 KV post insulator complete with Structure of 6 ft. with plate & all fasteners and foundation
22Supply, Installation, Testing & Commissioning of 150 mm dia B class GI pipe.GI pipe to be used/laid as per site requirment.
23Cost towards Supplying and fitting of Stay set complete with stay wire and stay clamp & foundation as required
24Supply, Installation, Testing & Commissioningof outdoor type Transformer of 33/11KV, 2MVA with OLTC & all safety device & other standard accessories with bushing arrangement. Make- Kirlosker/Simens/Crompton Greaves
25Cost towards Providing Discharge Rod for 33 KV and 11 KV with required materials at site for operation of 33/11 KV substation ,1 No. for each
26Cost towards Providing of Hand Gloves Heavy Duty for operation of 33/11 KV sub station33KV and 11 KV(1 no. each)
27Cost towards Providing and fixing of 33 KV/ 11 KV Danger Board as per standard specification.
28Cost towards Supply of Insulated rubber mat for 33 KV 100cmx100cmx2cm
29Supply, Installation, Testing & Commissioning of Firefighting equipment 5 Kg dry type
30Cost towards Making cable trench including excavation, earth work with brick. PCC work as required.
31Trickle Battery Charger with 24 Volt 100 AH Battery for VCB with stand.
32Supplying, Installation, Testing and commissioning of 11/.433 V, 25 KVA copper wounded 3 phase, 50 Hz, at full load and temp. rise not exceeding 45°Cby thermometer in oil and 50°Cby theresistance in winding after continuous run at full load rating. Transformer shall be latest manufacturing standers as per amended IS specification and the load and No load losses shell be limited to the valves given below or as per IS or Norms issued by JSEB.
33Cost of construction ofDP structure for 25 KVA transformer, supplying and erectingsteel tubular pole, top bracket channel, back clamp, 11 KV disc insulator with hardware , MS nut and bolt, MS angle, G.I wire, clamp for transformer base, top channel, D.O fuse angle, outdoor type horn gap fuse with insulator, AB switch of rotating type etc. all complete as per the site requirement and as per the direction of E/I.
34Supply, Installation and commissioning of Power control cum distribution cubical LT panel board, made of 2 mm thick, MS sheet of suitable size, dust & vermin proof consisting of Bus bar – 4 pole 200 A, 415 V copper strip bus bar enclosed in MS sheet Incoming feeder – 100 A TPN 415 V MCCB thermal release range, adjustable and breaking capacity with rotary operating mechanism handle – 01 no., Outgoing feeder – 32 A TPN 415 V MCCB thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ Siemens/ BCH – 06 no.all complete job. Voltmeter (0-200) V voltmeter with selector switch, Ammeter – (0-100) A C.T operated with selected switch, Indicating lamp and all type of relays with internally wired with suitable size of copper control wire/cable etc. all complete Panel should be duly painted with two coats super enameled paints of approved color one coat of red oxide primer.
35Supplying and Laying 35 mm2 3 core, HT Aluminum XLPE insulatedarmoured cable and overall PVC sheathed cable conforming to IS : 7098/II/85 with latest amendments. From main transformer to 25 KVA Transformer. Make :- polycab/Havells/KEI.
36Providing and erectingof 36/28 mm Aluminum pipe for swing bus bar.

AI Tender Summary

OUR REF NO 31227363
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 02-03-2022
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi
Basic Detail
Tender No e-Quotation No. 20/2021-22 (2nd Call)
Bidding Type Tender
Location
City dhurwa
State Jharkhand
Key Dates
Publish Date 25 Feb 2022
Submission Date 02 Mar 2022
Open Date 03 Mar 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
aee2d104-956f-4a97-930c-69e140cc0d46.html
BOQ_76202.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 25, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 02, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 03, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

aee2d104-956f-4a97-930c-69e140cc0d46.html

xls

BOQ_76202.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders