Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi Supplying, Installation, Co
Tender Overview
Project Description
Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi Supplying, Installation, Commissioning And Testing Of 2 Mva Outdoor Type Power Transformer With All Safety Device And Other Standard Accessories For 33 / 11 Kv New Sub-Station Under D.W. And S. Mech. Urban Division, Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Tubular pole of 11 Mts.as per IS 2713/80 in three sections Bottom 5.60 mts. Middle 2.7 Mts. And top 2.7 mts. Total wt. 256 Kg. as per 410-SP-57 |
| 2 | Supply ofof 9 Mtrs. H. Poleof weight 405 Kg. |
| 3 | Supply, of 6 Mtrs. H. Pole for Post Insulators |
| 4 | Supply Installation, testing & Commissioning of iron D.P. Channel with support clamp, nuts and bolts all complete. |
| 5 | Supply, Installation, testing & Commissioning of ACSR Panther Conductor |
| 6 | Supply Installation, testing & Commissioning of triple pole 33KV, 800 Amps out door type gang operated A.B switch triple pole (Horizontal strike) with 3 post/pin type insulator per phase mounted on provided cross arm with adequate length of G.I pipe for operating handle erected on extended square shaft the operating handle provided with lock and key at suitable height from ground with necessary clamp as per IS : 9921. |
| 7 | Supplying and fitting of 33 KV outdoor type VCB:- |
| 8 | Supplying, fitting & installation of 11 KV Indoor type VCB :- 11 KV 630 Amp., 25 KA Indoor type VCB suitable for control circuit voltage24 V DC, SPRING CHARGE MOTOR FOR 230V AC- 01 no., closing &Mechanism- 230 V AC single phase 50 Hz motor – 01 no., 11 KV CB with 06 nos., Insulator 01 set, panel Illumination lamp with door limit switch – 01 set, Door limit switch – 01 set, Space Heater with thermostat & switch – 01 setThermal blocks – 01 set, 13 N/o + 13 N/C Auxiliary contacts – 01 set, Thermostat setting – 01 no., Breaker control switch – 01 no., conforming to IEC 62271-100. Make – ABB/ Crompton / Schiender / Kirloskar. |
| 9 | Supplying and laying 400 mm2x 3 core, 11 KV XLPE, HT aluminum cableXLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable from sub- station to 11 KV VCB panel. Make- polycab/ Havells/KEI/Anchor |
| 10 | Supplying all materials, labour, tools and tackles for making Foundation for VCB and structure. |
| 11 | Supplying, Installation, Testing & Commissioning of Indoor type Oil cooled, Potential Transformer Ratio: 33000/v3/110V/v3 V 3 Phase, 50 Hz, Class 1, Suitable for 33 KV Line, ISI Mark, with all labours, tools & tackles and doing all line connections etc all complete. Make: Everest or ISI Marked. |
| 12 | Cost towards Supplying Installation Testing & Commissioning of Indoor type Oil cooled , Current Transformer Ratio: 150/1-1 Amp. 3 Phase, 50 Hz, Class 1, Suitable for 33 KV Line, ISI Mark, with all labours, tools & tackles and doing all line connections etc all complete. Make - Everest or ISI Marked. |
| 13 | Cost towards Supply, installation & testing of D.O fuse for 33KV system (1 set = 3Nos.). |
| 14 | Supplying, Installation, Testing & Commissioningof 33 KV Lightening Arrester Metal Oxide type. |
| 15 | Supplying, Installation, Testing & Commissioning of all required material for Maintenance free chemical earthing including with all accessories & earth cone & connected with accessories for HT equipment’s in substation area. |
| 16 | Supplying, Installation, Testing & Commissioning of Connectors of Different Types and Sizes as per the requirement of site conditions. |
| 17 | Supplying & laying copper conductor PVC Control Cable Size : 29 Core x 2.5 Sq.mm. Make- Havells/Polycab/KEI |
| 18 | Supply, Installation, Testing & Commissioning of 33 KV disc insulator complete with all fasteners and Hardware for Panther Conductor. (1 Set = 3 Nos.) |
| 19 | Supply, Installation, Testing & Commissioning of 33 KV pin insulator complete with pin & fasteners |
| 20 | Supply, Installation, Testing & Commissioning of Cross Bracing with Clamp and Nuts &Bolts all complete |
| 21 | Supply, Installation, Testing & Commissioning of 33 KV post insulator complete with Structure of 6 ft. with plate & all fasteners and foundation |
| 22 | Supply, Installation, Testing & Commissioning of 150 mm dia B class GI pipe.GI pipe to be used/laid as per site requirment. |
| 23 | Cost towards Supplying and fitting of Stay set complete with stay wire and stay clamp & foundation as required |
| 24 | Supply, Installation, Testing & Commissioningof outdoor type Transformer of 33/11KV, 2MVA with OLTC & all safety device & other standard accessories with bushing arrangement. Make- Kirlosker/Simens/Crompton Greaves |
| 25 | Cost towards Providing Discharge Rod for 33 KV and 11 KV with required materials at site for operation of 33/11 KV substation ,1 No. for each |
| 26 | Cost towards Providing of Hand Gloves Heavy Duty for operation of 33/11 KV sub station33KV and 11 KV(1 no. each) |
| 27 | Cost towards Providing and fixing of 33 KV/ 11 KV Danger Board as per standard specification. |
| 28 | Cost towards Supply of Insulated rubber mat for 33 KV 100cmx100cmx2cm |
| 29 | Supply, Installation, Testing & Commissioning of Firefighting equipment 5 Kg dry type |
| 30 | Cost towards Making cable trench including excavation, earth work with brick. PCC work as required. |
| 31 | Trickle Battery Charger with 24 Volt 100 AH Battery for VCB with stand. |
| 32 | Supplying, Installation, Testing and commissioning of 11/.433 V, 25 KVA copper wounded 3 phase, 50 Hz, at full load and temp. rise not exceeding 45°Cby thermometer in oil and 50°Cby theresistance in winding after continuous run at full load rating. Transformer shall be latest manufacturing standers as per amended IS specification and the load and No load losses shell be limited to the valves given below or as per IS or Norms issued by JSEB. |
| 33 | Cost of construction ofDP structure for 25 KVA transformer, supplying and erectingsteel tubular pole, top bracket channel, back clamp, 11 KV disc insulator with hardware , MS nut and bolt, MS angle, G.I wire, clamp for transformer base, top channel, D.O fuse angle, outdoor type horn gap fuse with insulator, AB switch of rotating type etc. all complete as per the site requirement and as per the direction of E/I. |
| 34 | Supply, Installation and commissioning of Power control cum distribution cubical LT panel board, made of 2 mm thick, MS sheet of suitable size, dust & vermin proof consisting of Bus bar – 4 pole 200 A, 415 V copper strip bus bar enclosed in MS sheet Incoming feeder – 100 A TPN 415 V MCCB thermal release range, adjustable and breaking capacity with rotary operating mechanism handle – 01 no., Outgoing feeder – 32 A TPN 415 V MCCB thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ Siemens/ BCH – 06 no.all complete job. Voltmeter (0-200) V voltmeter with selector switch, Ammeter – (0-100) A C.T operated with selected switch, Indicating lamp and all type of relays with internally wired with suitable size of copper control wire/cable etc. all complete Panel should be duly painted with two coats super enameled paints of approved color one coat of red oxide primer. |
| 35 | Supplying and Laying 35 mm2 3 core, HT Aluminum XLPE insulatedarmoured cable and overall PVC sheathed cable conforming to IS : 7098/II/85 with latest amendments. From main transformer to 25 KVA Transformer. Make :- polycab/Havells/KEI. |
| 36 | Providing and erectingof 36/28 mm Aluminum pipe for swing bus bar. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender