Repair / Maint Of Lt Panel / Cable And Earthing And Cleaning And Periodical Services To O / H Tank And Underground Sump And Pump House Bldg At Af Station Bhowali And Lkt Under Age ( Af ) Bhowali Repair / Maint Of Lt Panel / Cable And Earthing And Cleani, bhowali-Uttarakhand

Military Engineer Services-MES has published Repair / Maint Of Lt Panel / Cable And Earthing And Cleaning And Periodical Services To O / H Tank And Underground Sump And Pump House Bldg At Af Station Bhowali And Lkt Under Age ( Af ) Bhowali Repair / Maint Of Lt Panel / Cable And Earthing And Cleani. Submission Date for this Tender is 12-03-2022. Electrification Work Tenders in bhowali Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

31225399
Repair / Maint Of Lt Panel / Cable And Earthing And Cleaning And Periodical Services To O / H Tank And Underground Sump And Pump House Bldg At Af Station Bhowali And Lkt Under Age ( Af ) Bhowali Repair / Maint Of Lt Panel / Cable And Earthing And Cleani
Open Tender
Indian
Uttarakhand
bhowali
12-03-2022

Tender Details

Repair / Maint Of Lt Panel / Cable And Earthing And Cleaning And Periodical Services To O / H Tank And Underground Sump And Pump House Bldg At Af Station Bhowali And Lkt Under Age ( Af ) Bhowali Repair / Maint Of Lt Panel / Cable And Earthing And Cleaning And Periodical Services To O / H Tank And Underground Sump And Pump House Bldg At Af Station Bhowali And Lkt Under Age ( Af ) Bhowali

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF LT PANEL/CABLE AND EARTHING AND CLEANING AND PERIODICAL SERVICES TO O/H TANK AND UNDERGROUND SUMP AND PUMP HOUSE BLDG AT AF STATION BHOWALI AND LKT UNDER AGE (AF) BHOWALI.
Sl. No. Item Description
1Dismantling & taking out LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar/ street light pole box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed.
2M&L for dismantling of of old damaged /cracked PCC coping and prepare the new copingfor steel/PCC pole using PCC 1:3:6 type D-2 with 20 mm graded stone aggregate making collar aboveground level on existing foundation of pole size 450x450x300 mm high and plastering with 1:4 cement sand mixter for smooth look incl curing to achieve the strength and breaking/removing existing old damaged coping complete all as specified and directed .
3Repair of earth pit incl required excavation ,earth work and PCC work to make good damaged /disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B1 using 20 mm graded stone aggregate reinforced and lifting handle on RCC cover with 8 mm bars at 150 mm centre to centre both ways incl supply & fixing of wire mess and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts washer complete all as specified and directed
4Trimming/cutting of tree /removal of bushes/removal of vegetation growth/cutting trunk portion protruding over ground, digging out rootsarround 2 mtr radius ofLT panel and removal from site all as directed Note : this job may be repeated after three month at the same location.
5M & L for spray painting of old/existing out door LT panel/feeder piller box any size/type( with powder coated paint usinglight grey paint in outerside areaof complete panel after cleaning and preparing surface incl sign writing & writting of panel No complete all as specified & directed
6M&L for boring under road horizontaly of size 50/80 mm bore of GI pipe for passing of cable in road in hard/soft/ loose soilcomplete all as specified and directed.
7Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out in hard/ dense soil for electric cable complete in any type of soil complete
8Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point
9Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete .
10Supply and laying sub class "B" bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
11M & L for sand cushioning with Ganga Sand to underground cable (10 cm thick before laying and 15 cm thick after laying the cable complete
12Checking, identifying the defect /faulty point ofLT cable using Cable fault locator machine or by manual excavation and taking out bricks from the trench uptofaultpoint along cable routeand re-layingthe sameusing old bricks/sand incl returning filling and making goodsurface after rectification of defect complete all as directed for the following lengthof cable :
13(a) 0 -150 mtr
14(b) 0 - 200 mtr Note- (i)Cable fault locator machine with all T&Prequired for identifying the faulty point will be arrange by contractor and thecost isincluded in unit rate for finding of fault using machine or by manualy
15Repairing/overhauling of existingOut door type LT panel board/feeder pillar box of any size/type fixed on PCC block incl cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors withproper fixing & locking arrangement &necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to PCC workas require at site and including disconnection of all cable from the bus bar and insulating the naked portion ofAl conductorand re-connect the sameafter repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
16Description all as per item No. 13 above butindoor type panel fixed at power house & pump houses complete all as specified and directed.
17Repairing/overhauling of existingindoor type LT panel board/bus bar / V-TPN DBs of any size/type fixed on building wallincl cleaning with compressed air, tightening of all electric connection to the bus bar& switch gears , refixing of loosed doors withproper fixing & locking arrangement &necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster workas require at site and including disconnection of all cable/ sub main from the bus bar and insulating the naked portion ofAl conductorand re-connect the sameafter repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
18M& L for preparing door of existingLT panel / feeder pillar box withlocking arrangement & gasketedmade of CRCA sheet 2 mm thick including hing & welding work complete all as specified and directed.
19M & L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI earth wire 4mm dia by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade,funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point/equipment and testing complete
20Description all as per item No. 17 above but with GI strip 32 x 6mm as earthing lead (earth strip will be protected by using 40mm bore GI pipe "light grade") complete all as specified and directed.
21Description all as per item No. 17 above but using 600x600x3.15 mm copper plate including 20x3 mm earthing lead (earth strip will be protected by using 40mm bore GI pipe "light grade) complete all as specified and directed.
22S&F (in replacement ) MCB DB SPN 2 way double door type , comprising of one MCB SPN 16 Amp "B" series 415 volt incl fixing of DB on pole/ wallwith suitable arrangement for the garden light incl making wall surface smooth as existing using plastering and white wash complete all as specified and directed.
23Disconnecting of all electric and water connections from RO water purifier of any capacity and make, opening the same and repairing the same after replacement of defective spare parts and re-connecting all electrical and water connections after repairs complete all as specified and directed. NOTE: - All spare parts shall be measured and paid separately under respective items of this schedule as ‘Supply only’. (a) Adopter. (b) Sediment filter. (c) Pump (d) Membrane. (e) Carbon filter.
24Cleaning of RCC water reservoir (sump) and PVC tank of any capacity, drain out water partly, removing all scale and dirt etc from sump/tank, cleaning by using wire / coir brush with bleaching powder and water etc complete all as directed, re-writing the letter not exceeding 25 cm on high as ‘Tank Cleaned on indicating date, month and year of cleaning with synthetic enamel paint white in colour on black base complete for the following locations all as directed by the Engr in charge. a)Under ground sump in 2 halfs Near pump house No 1 at Nainital b)Water storage sump of 50,000 Ltrs capacity above ground level at Pump house No 2 at Pines c)Water storage sump of 5,000 Ltrs capacity above ground level at Pump house No 2 at Pines d) Water storage PVC tank of 60,000 Ltrs capacity above ground level at Pump house No 3 at pines to LKT road e) Water storage PVC tank of 25000 Ltrs capacity above ground level at Pump house No 4 at Pines to LKT road f) Water storage PVC tank of 25000 Ltrs capacity above ground levelat LKT g) Water storage PVC tank of 75000 Ltrs capacity above ground level at LKT h) Static water storage tank open type of capacity 50000 ltrs at LKT
25Supply and fixing in repair Fully automatic Star Delta motor starter in sheet steel enclosure 15/20 HPmax out put at 415 Volt, 3 phase, relay range-14 to 23 Amp , 415Volt,50 Hz,3phase,Make- L/T MK 1 or Equivalent, with all electrical connections as specified and as directed.
26Supply, installation, commissioning and testing of 415 volts, 50 Hz, 3 phase fully automatic motor starter oil immeresed type star delta motor starter suitable for 15 / 20 HP duly in-housedin sheet metal enclousere alongwith over load protector relay of 14 to 23 Ampere with and including dismantling of old unserviceable one complete all as specified and directed.
27Supply only Ortho Tollidine solution for water testing, in 500 ml bottles complete all as speicified.
28Supply only water testing Kit with all accessories, samples in tubes from 0.1 ppm to 5 ppm from reputed manufacturer complete all as specified.
29Supply only Calcium based high strength granular chlorination chemical for treatment of drinking water (Calcium Hypo chlorite 65% to 70% chlorine content) in 45 Kg PVC sealed drum complete allas specified and directed. Make:- Traditional product ofmake "Puri Chlor" manufactured by Shree Rayalaseema Hi-Strength Hypo Ltd OR Potter & Watts OR of any other make as approved by E-in-C"s Branch, New Delhi.
30Collection of water sample from the bore well and testing of the same for potability (bacteriological and chemical analysis) of drinking purpose from the Uttrakhand Jal Sansthan Nainital or any other Govt. recognized lab for testing of potable water and submission ofreport to the department complete all as specified and directed.
31M & L for opening of top and bottom cover of vertical type pressure feed filtration plant of capacity 20000 Litres per hour at Pump House No. 02 (Pines) including taking out old filter media and strainer etc and depositing the same to a distance not exceeding 50 metres complete all as specified and directed.
32M&L for Scrapping and cleaning of the inner and outer surfaces of the filter bed of the shell for complete removal of scales, rust old paint etc and painting with two coats of anti corrosive bituminous paint suitable for storage of potable water for internal / external surfaces and two coats of synthetic enamel paint of approved colour forhorizontal type pressure feed filtration plant of capacity 20000 Litres per hour complete all as specified and directed.
33Laying only gravel of different sizes for vertical type, pressure feed filteration plant of capacity 20000 Litres per hour in different layers complete all as specified and directed.
34Dismantling & taking out defective LT PVC/XLPE cable from trenches with cutting and removing defective parts and supply & making cable joint using strait through joint cold shrink type and making connection of LT cables, meggering & re-storation of electric supply complete including jointing materialfor the following sizes of cable :- Joint make- Reychem
35(a) 25 sqmm 3.5 core to 70 sqmm, 3.5 core
36(b) 95 sqmm 3.5 core to 240 sqmm 3.5 core
37S&F (in replacement) following items in the existing out door/ indoor LT panelsand connection with using aluminum lugs/ferruls incl disconnection & connection of cable andmaking necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :- (Note :-Make of MCCB/MCB : Schneider/L&T/ABB/Havells)
38(a) MCCB 4 Pole100 amps rating, 25 KA breaking capacity, 415 Volt
39(b) MCCB 4 pole 125 amps rating, 25 KA breaking capacity with spreaderat both side
40(c) MCCB 4 pole150/160 amps rating, 35 KA breaking capacity with spreaderat both side
41(d) MCCB 4 pole 200 amps rating, 35 KA breaking capacity with spreaderat both side
42(e) MCCB 4 pole 250 amps rating, 35 KA breaking capacitywith spreaderat both side
43(f)MCCB 4pole 315 amps rating, 35 KA breaking capacity with spreaderat both side
44(g) MCCB 4 pole 400 amps rating, 50 KA breaking capacity with spreader at bothe side
45(h) Volt meter (0 to 500 volts) anologtype with selector switch for three phase
46(j)Amp meter (0 to 500 amps) anolog type,witch selector switch for three phase measurement .
47(k) CTs of existing ratio and capacity fixed in LT panels and connect with ammeter
48(l) Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar.
49(m) MCB TPN 100 amps, "C" series, 415 volt
50Disconnecting & dismantling of damaged/unsv cable any type /make and Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for following size :- (Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid seperately)
51(a) 25 Sqmm 4 core
52(b) 35 Sqmm4 core
53(c) 50 Sqmm 3.5 core
54(d) 70 Sqmm 3.5 core
55(e) 95 Sqmm 3.5 core
56(f) 120 Sqmm 3.5 core
57M&L (in replacement) for GI tubing "light grade" with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for following sizes :-
58(a) 50 mm bore
59(b) 80 mm bore
60M & L for busbar chamber box of 1.6 mm sheet with tinned plated 04 Nos copper bars of following bus bar and following box size, factory made, suitable for pole/wall mounted including all connections with aluminum strips/lugs, glands to be provided at cable entries, powder coated paint complete for the following rating:-
61(a) Bus bar of rating 100 amps
62(b) Bus bar of rating 200 amps
63S&F MCCB 4 pole, 415 volts with suitable size of sheel metal enclosure and connection with using aluminum lugs and making arrangement to fix on wall or on PCC(1:2 :4) Bock complete for the following capacity/rating:-
64(a) 63 amps rating, 25 KA breaking capacity with bothe sidespreader for cable connection
65(b) 100 amps rating, 25 KA breaking capacity with bothe sidespreader for cable connection
66Supply only new washed, cleaned, dust free graded pea gravels of following sizes suitable for use in filteration plant of following sizes: -
67(a) 1.50 mm to 3.00 mm size.
68(b) 3.00 mm to 6.00 mm size.
69(b) 6.00 mm to 15.00 mm size.
70S & F of 6 mm thick rubber gasket suitable for filteration plant complete all as specified and directed.
71Cleaning of RCC overhead water reservoir of capacity 1,80,000 Litres in Adm area, drain out water partly, removing all scale and dirt etc. from tank, cleaning the same by using wire / coir brush with bleaching powder and water, re-writing (at bottom) the letter not exceeding 25 cm on hight as ‘Tank Cleaned on indicating date, month and year of cleaning with synthetic enamel paintwhite in colour on black base block including removal of sludge and vegitation inside or out side and depositing the same in low lying area complete all as as specified and directed.