Repair / Maint To Various Summer Cooling Appliances, Refgn And Ac Machinery / Equipment And Connected Works At Jhansi Cantt, Caleb Vihar, Aau And Mil Station Nowgong Under Age E/M At Ge Jhansi Repair / Maint To Various Summer Cooling Appliances, Refgn And, jhansi-Uttar Pradesh

Military Engineer Services-MES has published Repair / Maint To Various Summer Cooling Appliances, Refgn And Ac Machinery / Equipment And Connected Works At Jhansi Cantt, Caleb Vihar, Aau And Mil Station Nowgong Under Age E/M At Ge Jhansi Repair / Maint To Various Summer Cooling Appliances, Refgn And. Submission Date for this Tender is 12-03-2022. Air Conditioner Tenders in jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

31223743
Corrigendum : Repair / Maint To Various Summer Cooling Appliances, Refgn And Ac Machinery / Equipment And Connected Works At Jhansi Cantt, Caleb Vihar, Aau And Mil Station Nowgong Under Age E/M At Ge Jhansi Repair / Maint To Various Summer Cooling Appliances, Refgn And
Open Tender
Indian
Uttar Pradesh
jhansi
12-03-2022

Tender Details

Repair / Maint To Various Summer Cooling Appliances, Refgn And Ac Machinery / Equipment And Connected Works At Jhansi Cantt, Caleb Vihar, Aau And Mil Station Nowgong Under Age E/M At Ge Jhansi Repair / Maint To Various Summer Cooling Appliances, Refgn And Ac Machinery / Equipment And Connected Works At Jhansi Cantt, Caleb Vihar, Aau And Mil Station Nowgong Under Age E/M At Ge Jhansi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work :Repair / Maint to various summer cooling appaliances, REFGN & AC machinery /equipment and connected works at Jhansi Cantt, AAU area & Military Station Nowgong (BKD) Under AGE E/M at GE Jhansi
Sl. No. Item Description
1M&L for Servicing of window type AC 1.5 / 2.0 TR capacity, any type/make, by carefully taking down from window / wall,removing power connection, front PVC grill, air filters and applying air blower to remove all dust, washing, cleaning, removing dirt, including cleaning and washing of cooling and condenser coil, re-assembling the dismantled components,refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
2M&L for servicing of split type AC of 1.5 / 2.0 TR capacity, any type/make, in situ at installed location, removing power connection, carefully opening the indoor and outdoor unit, removing filters, applying blower in both the units to remove all dust, cleaning, washing, removing dirt, including cleaning and washing of evaporator coil of indoor cooling unit and condenser coil of outdoor unit, re-assembling the dismantled components,refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
3Supply and fix in replacement of set of PVC filters suitable for window type AC / indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
4Supply and fix in replacement of following spare parts suitable for indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
5Blower bush
6Blower fan blades
7Blower motor
8PCB
9Display unit
10Swing motor
11Capacitor 1.0 mdf to 2.5 mfd suitable for blower motor
12Supply and fix in replacement of suction / discharge valve, brass, of size 1/4"" to 3/4"" suitable for outdoor unit of split type AC 1.5 Ton / 2.0 TR capacity / suction / discharge valve of package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge.
13Supply and fix in replacement of thermostat temperature sensor suitable for indoor unit of split type AC / window type AC 1.5 Ton / 2.0 TR capacity of existing model / package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge.
14Supply and fix in replacement of PCB with display unit suitable for window type AC 1.5 TR / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
15Supply and fix in replacement of following spare parts suitable for window type / outdoor unit of split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
16Hermetically sealed reciprocating type / rotary type compressor unit 1.5 TR capacity including gas charging complete
17Hermetically sealed reciprocating type / rotary type compressor unit 2.0 TR capacity including gas charging complete
18Running capacitor 35 mfd to 60 mfd
19Fan motor, copper wound
20Fan blades
21Fan capacitor 4.0 mfd to 6.0 mfd
22Supply and fix in replacement of copper condenser coil suitable for outdoor unit of 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
23Supply and fix in replacement of single phase contactor suitable for 1.5 / 2.0 TR capacity split type Air conditioners / Walk-in-cooler of existing model complete all as specified and directed and by Engineer-in-Charge.
24Supply and fix in replacement of window AC Kit, company made, consist of metal sheet enclosure / housing, cooling coil, condenser coil, PVC front grill, wiring kit, Fan motor, condenser fan and blower, PCB and remote hand set etc complete, suitable for air conditioner of 1.5 TR capacity complete all as specified and directed by Engineer-in-Charge.
25M&L for gas charging of Air Conditioner window / split type / walk-in-cooler of capacity 1.5 / 2.0 TR with R - 22 / R-32 /R-410a or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/brazing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge.
26Supply and fix in replacement of copper tube of size 1/4"" to 1/2"" suitable for 1.5 / 2.0 TR capacity split type Air conditioners / walk-in-cooler / Central / package type AC of existing model complete all as specified and directed and by Engineer-in-Charge.
27Supply and fix in replacement of nitrile rubber foam insulation of size 1/4"" to 1/2"" suitable for 1.5 / 2.0 TR capacity split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
28Supply and fix in replacement of PVC front grill suitable for 1.5 / 2.0 TR capacity window type Air conditioners of existing make / model complete all as specified and directed and by Engineer-in-Charge.
29Supply and testing in replacement of remote control unit with batteries suitable for 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge.
30Supply and fix in replacement of PVC insulated and PVC sheathed 3 core x 1.5 sqmm stranded copper conductor conforming to IS:694 complete all as specified and directed by Engineer-in-Charge.
31Supply and fix in replacement of indoor cooling unit complete with evaporator coil, blower motor with fan, PCB with display and remote control unit suitable for split air conditioner of 1.5 TR capacity with and including making connection etc complete all as specified and directed by Engineer-in-Charge.
32All as per item No. 18.00 here-in-before but of capacity 2.0 TR.
33Supply and fix in replacement of 20A rated metal clad plug, 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC complete all as specified and directed by Engineer-in-Charge.
34Supply and fix in replacement of 20A rated metal clad socket, 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC complete all as specified and directed by Engineer-in-Charge.
35Supply and fix in replacement of MCB, SP, 6-32A, "C" curve complete all as specified and directed by Engineer-in-Charge.
36Supply and fix in replacement of Plug top, 3 pin, 20 Amps, single phase, 230 volts, 50 Hz complete all as specified and directed.
37Supply and fix in replacement of heavy duty Mild Steel powder coated wall mount bracket with grouting bolts complete set suitable for wall mounting of outdoor unit of 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge.
38Supply and fix in replacement of PVC drain pipe 1/2"" size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge.
39Material and labour for shifting of Split type AC 1.5 / 2.0 TR capacity of any make / model from one location to the other location alongwith stabilizer by carefully taking down the indoor and outdoor unit, copper piping with insulation, drain pipe, wall mount bracket etc and installing the same at new location including testing & commissioning complete all as directed by Engineer-in-Charge. Note : 1. The cost of making hole for passing through inlet / outlet copper pipes, drain pipe and electrical cable and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.2. Extra copper piping if required at new location will be measured and paid separately under respective items.
40Material and labour for shifting of window type AC of any type/make / model of 1.5 / 2.0 TR capacity alongwith stabilizer from one location to other location complete with and including making of suitable opening in wall or cutting and removing steel grill from existing window, with and including supply and fixing of new wooden frame / plywood of suitable size and thickness for proper fixing of outer chassis of AC at new location including painting with matching colour, making good of disturbed surface as original etc, including testing & commissioning, complete all as directed. Note : The cost of making suitable opening in brick wall or removing steel grill and/or glass pane from existing window and making good of surface at both location as original by brick work, plastering / whitewash / colour / distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
41Supply and fix in replacement of split AC outdoor unit Kit of 1.5 TR capacity, company made, consist of metal sheet enclosure / housing, condenser coil, wiring kit, condenser fan motor, condenser fan and blower, PCB etc completecomplete all as specified and directed by Engineer-in-Charge.
42All as per item No. 28.00 here-in-before but of capacity 2.0 TR.
43Material and labour for gas charging of deep freezer of capacity up to 310 Liters with R - 22 / R-134A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge.
44Supply and fix in replacement of following spare parts suitable for deep freezer of capacity up to 310 Liters of existing model complete all as specified and directed and by Engineer-in-Charge:-
45Hermetically sealed reciprocating type / rotary type compressor unit including gas charging.
46Compressor start relay.
47Overload relay
48Starting capacitor 40/60 mfd to 100/120 mfd
49Running capacitor 10 mfd to 30 mfd
50Copper condenser coil
51Thermostat
52LED indication lamp Red / Green
53ON / OFF switch
54Supply and fix in replacement of aluminium body shaded pole motor, 220/240V, 50-60Hz, 1300-1500 RPM of suitable rating for deep freezer of capacity up to 310 Liters / water cooler of capacity up to 150 liters capacity of existing model complete all as specified and directed and by Engineer-in-Charge.
55Supply and fix in replacement of 4"" x 4"" exhaust fan, 220/240V, 50Hz suitable for deep freezer / refrigerator of capacity up to 310 Liters of existing model complete all as specified and directed and by Engineer-in-Charge.
56Supply and fix in replacement of refrigerant filter drier suitable for deep freezer of capacity up to 310 Liters / water cooler of capacity up to 150 liters of existing model complete all as specified and directed and by Engineer-in-Charge.
57Material and labour for gas charging of refrigerator of capacity up to 310 Liters with R - 22 / R-134A / R-438A / R-600A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge.
58Supply and fix in replacement of following spare parts suitable for refrigerator of capacity up to 310 Liters, single phase, 230 V, 50 HZ, AC of existing model complete all as specified and directed and by Engineer-in-Charge.
59Hermetically sealed reciprocating type / rotary type compressor unit including gas charging
60Compressor start relay
61Overload relay
62Copper condenser coil
63Thermostat
64Refrigerant filter drier
65Heater
66PCB
67Freezer unit
68Timer
69Bimetal
70Material and labor for gas charging of water cooler of capacity 40 / 80 Liters to 150 / 150 Liters with R - 22 / R-134A or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/bracing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge.
71Supply and fix in replacement of following spare parts suitable for water cooler of capacity 40 / 80 Liters to 150 / 150 Liters of existing model complete all as specified and directed and by Engineer-in-Charge.
72Hermetically sealed reciprocating type / rotary type compressor unit for 40 / 80 Liters capacity including gas charging.
73Hermetically sealed reciprocating type / rotary type compressor unit for 60 / 120 Liters capacity including gas charging.
74Hermetically sealed reciprocating type / rotary type compressor unit for 150 / 150 Liters capacity including gas charging.
75Compressor start relay
76Overload relay
77Copper condenser coil
78Thermostat
79Chromium plated self closing push cock tap 15mm with all fixing accessories complete
80PVC waste water pipe
81Float valve with rod, ball and fixing accessories complete of 15mm
82Material and labour for tinkering work to water storage steel tank of water cooler by welding / bracing to arrest the leakages including grinding and polishing to make smooth surface complete all as directed by Engineer-in-Charge.
83Material and labour for Mild Steel work such as channels, angles, bracings, supports, clamps and back plates of any size fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint of approved colour complete all as specified and directed by Engineer-in-Charge.
84Material and labour for servicing of central / package type air conditioning plant of capacity 3 x 5.5 TR (Make: Bluestar) by carefully dismantling the unit (without making any damage), at installed location, removing filters, applying blower to remove all dust, cleaning, washing, removing dirt, washing and cleaningof evaporator including dismantling condenser unit and cleaning all condensing tubes and replacing gasket, nut, bolt, washers etc as per site requirement, re-assembling the dismantled components,refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
85All as per item No. 41.00 here-in-before, but of plant capacity 3 x 11 TR (Make: Bluestar)
86Material and labour for descaling of central / package type air conditioning plant of capacity 3 x 5.5 TR (Make: Bluestar) by running descaling compound for not less than 6 hours through pump and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
87All as per item No. 43.00 here-in-before, but of plant capacity 3 x 11 TR (Make: Bluestar)
88Material and labour for gas charging of central / package type air conditioning unit of capacity 5.5 TR (Make: Bluestar) with R - 22 or any other recommended refrigerant gas, including detecting of leakage, repairing using welding / brazing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge.
89All as per item No. 45.00 here-in-before, but of unit capacity 11 TR (Make: Bluestar)
90Supply and fix in replacement of following spare parts suitable for Central / package type air conditioning plant of capacity 5.5 TR / 11 TR of Bluestar make, AC, 3 Phase, 50 Hz, of existing model complete all as specified and directed and by Engineer-in-Charge.
91Hermetically sealed scroll compressor unit 5.5 TR capacity including gas charging with recommended refrigerant of required quantity complete
92HP / LP cut out unit
93Single phase Transformer 230V AC / 13 V AC, 500 mA
94Four pole, 415 V, 50Hz cable terminal connector block
95Four pole power contactor, 415 V, 50Hz
96Thermal overload relay
97NC / NO auxiliary contactor
98Copper expansion valve
99Refrigerant filter drier
100V" belt for blower motor
101Supply and fix in replacement of Mild Steel Pipes heavy grade with all fittings such as socket, coupling, bend, Tee, reducer etc laid in floors or fixed to walls and ceilings etc of size 25mm dia nominal bore, plain end as per IS:1239 (I), including cutting, welding, threading and joining etc as per site requirement and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer including taking up / down of existing unserviceable pipe of any description complete all as specified and directed by Engineer-in-Charge.
102All as per item No. 48.00 here-in-before, but of size 40mm nominal bore.
103All as per item No. 48.00 here-in-before, but of size 65mm nominal bore.
104All as per item No. 48.00 here-in-before, but of size 80mm nominal bore.
105Supply and fix MS slip-on weldable flange suitable for 65mm / 80mm NB pipe complete all as specified and directed by Engineer-in-Charge.
106Material and labour for flange joint with rubber or fibre board gasket including suitable bolts, nuts and washers for 65mm / 80 mm NB pipe complete all as specified and directed by Engineer-in-Charge.
107Supply and fix in replacement of CI Butterfly valve of size 40mm nominal bore as per IS 13095, PN 16, wafer type without lugs, suitable for clamping between flanges as per ANSI B 16.1 CI-125, including flanges, fittings, gasket, nuts, bolts, washers etc. including taking up / down of existing unserviceable butterfly valve of any description complete all as specified and directed by Engineer-in-Charge.
108All as per item No. 54.00 here-in-before, but of size 65mm nominal bore.
109All as per item No. 54.00 here-in-before, but of size 80mm nominal bore.
110Supply and fix in replacement of Cast Iron Non Return Valve (NRV) of size 65mm NB with flanged ends swing type / ball type ISI marked including necessary packing material, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.
111All as per item No. 57.00 here-in-before, but of size 80mm nominal bore.
112Supply and fix in replacement of dial type pressure gauge 0-14 Kg / Cm2 with all fixing accessories complete all as specified and directed and by Engineer-in-Charge.
113Supply and fix in replacement of vertical scale type dual scale (°F & °C) hot water thermometer with all fixing accessories suitable for fixing on hot waterpipe line in central air conditioning plant complete all as specified and directed and by Engineer-in-Charge.
114Supply and fix in replacement of forged brass ball valve of size 25mm NB with screwed female ends complete all as directed.
115Material and labour in replacement of duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 25mm andincluding the following:- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leak proof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 meter.
116Supply, assemble and erection in replacement of HVAC duct, GI sheet with TDF flange rectangular/square duct made out of "L" shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge all as specified and as directed by Engineer-in-Charge.
117Supply and fix in replacement of finned strip heater, 3 KW, 230 Volts, 50 Hz, made of Stainless Steel, GP Sheathing having the heat Resistance Chrome nickel 80/20 heating element protected under the best insulation to avoid the leakage of current and to ensure the long life of the heaters. Finns to increase the output of heat to the maximum dissipation and having screw type terminals on one end for proper connection complete all as specified and directed by Engineer-in-Charge.
118Supply, connecting and testing in replacement of Stranded Annealed Bare Copper Conductor /950° Mica Tape Wrapped/Xlpe Insulation/Cores Laid up together/Fibre Glass Tape Wrapped/FRLS Inner Sheathed/GI Wire Strip Armoured/ FRLS Outer sheathed Fire Survival Cable of size 4 core x 10 sqmm complete all as specified and directed by Engineer-in-Charge.
119Removing of monoblock electric driven water pump set of any make and capacity up to 5 HP from its installed position by disconnecting suction and delivery lines, fixing dummy plate to both suction & delivery pipe, disconnecting electrical cables, earth strips and dismounting the pump and motor from base channel and shifting to civil workshop for Overhauling of pump set by opening the pump and motor, replacing the worn out/defective spare parts, making good of shaft and shaft sleeve, cleaning internally, lubricating the rotating parts, reassembling the pump and motor duly replacing the all the packing material, "O" rings, worn out bolts, nuts, washers etc and bringing back and reinstalling in its original position, checking alignment, reconnecting the water mains and electric connections and testing on completion for satisfactory performance complete all as directed. Note: Rewinding of motor and spare parts required shall be measured and paid separately under relevant items of BOQ.
120Cutting and removing burnt out winding from electric motor of any make up to 5 HP and rewinding with super enameled copper winding wire of existing gauge and number of turns including varnishing, heating etc and testing for satisfactory performance complete all as specified and directed.
121Supply and fix in replacement of ball bearing suitable for monoblock pump set of any make and capacity up to 5 HP all as per sample suitable for existing model of pump set and as specified and directed.
122Material and labour for preparation of old painted steel surfaces of monoblock pump set of capacity up to 5 HP and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
123Supply and fix MCCB 160A, 3 Pole, 36 KA with adjustable thermal magnetic setting (Ics = 100% Icu) with sheet steel enclosure with built in neutral link including connecting up incoming and outgoing cables with suitable stainless steel cable glands and aluminium cable lugs and fixing on wall surfaces including taking down existing unserviceable main switch of any description complete all as specified and directed by Engineer-in-Charge.
124All as per item No. 77.00 here-in-before but of MCCB 200A, 3 Pole, 36 KA with adjustable thermal magnetic setting (Ics = 100% Icu)
125Material and labour for servicing of walk-in-collar of capacity 2.0 TR, of Bluestar make, in situ at installed location, removing power connection, carefully opening the indoor and outdoor unit, removing filters, applying blower in both the units to remove all dust, cleaning, washing, removing dirt, including cleaning and washing of evaporator coil of indoor cooling unit and condenser coil of outdoor unit, re-assembling the dismantled components,refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
126Supply and fix in replacement of blower fan motor, 75W (1/10 HP), 230V, 50Hz, 1 ph, AC with 900 RPM speed, copper wound complete all as specified and directed by Engineer-in-Charge.
127Supply and fix in replacement of Hermetically sealed reciprocating type CR 30 compressor unit 2.0 TR capacity including gas charging complete suitable for walk-in-cooler of existing model complete all as specified and directed and by Engineer-in-Charge.
128Supply and fix in replacement of refrigerant filter drier suitable for walk-in-cooler of capacity 2.0 TR existing model complete all as specified and directed and by Engineer-in-Charge.
129Supply and fix in replacement of PCB with display unit suitable for existing model Central / package type air conditioning unit of capacity 5.5 TR / 11 TR / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge.
130Supply and fix in replacement of complete set of PVC honeycomb fills and eliminators suitable for Delta Cooling Tower of central type air conditioning plant of capacity 3 x 5.5 TR / 3 x 11.0 TR complete all as specified and directed by Engineer-in-Charge.
131Supply and fix in replacement of Aluminium Rotary Sprinkler suitable for Delta Cooling Tower of central type air conditioning plant of capacity 3 x 5.5 TR / 3 x 11.0 TR complete all as specified and directed by Engineer-in-Charge.
132Supply and fix in replacement of Aluminium Fan suitable for Delta Cooling Tower of central type air conditioning plant of capacity 3 x 5.5 TR / 3 x 11.0 TR complete all as specified and directed by Engineer-in-Charge.
133Supply and fix in replacement of Rotary Switch (90° operation complete rotation), 4 pole ON-OFF, 32 Amps rating, motor duty switch suitable for panel mounting complete all as specified and as directed by Engineer-in-Charge.
134All as per item No. 80.00 here-in-before but of rating 63 Amps.
135S&F in replacement of automatic voltage stabilizer for low and high voltage cut-off, single phase, AC, 50 HZ, 4 Amps rating, suitable for input voltage range 135V - 280V for Water Cooler complete all as specified and directed by Engineer-in-Charge.
136S&F in replacement of wall mounted type voltage stabilizer 5 KVA, Copper Wound, Single Phase suitable for input voltage range 130 V to 280 V with time delay of 3Min ± 20 Sec and output voltage stabilized to 220 V ± 10% with high voltage cut-off and thermal overload protection complete with smart digital display suitable for inverter type split ACs, complete all as specified and directed.
137S&F in replacement of wall mounted type voltage stabilizer 4 KVA, Copper Wound, Single Phase suitable for input voltage range 130 V to 280 V with time delay of 3Min ± 20 Sec and output voltage stabilized to 220 V ± 10% with high voltage cut-off and thermal overload protection complete with smart digital display suitable for inverter type split ACs, complete all as specified and directed.
138Material and Labour for sub main wiring with 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire) with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed by Engineer-in-Charge for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) Notes:- (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
139Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail