Infrastructure Development Modernization Digitalization And Reformation Of Oidc Warehouses Godowns At Plot No 20 Masat Dnh ( 2Nd Call ) , Daman and Diu-Daman And Diu

Omnibus Industrial Development Corporation-OIDC has published Infrastructure Development Modernization Digitalization And Reformation Of Oidc Warehouses Godowns At Plot No 20 Masat Dnh ( 2Nd Call ) . Submission Date for this Tender is 03-03-2022. Infrastructure Work Tenders in Daman and Diu Daman And Diu. Bidders can get complete Tender details and download the document.




Tender Notice

31220167
Infrastructure Development Modernization Digitalization And Reformation Of Oidc Warehouses Godowns At Plot No 20 Masat Dnh ( 2Nd Call )
Open Tender
Indian
Daman And Diu
Daman and Diu
03-03-2022

Tender Details

Infrastructure Development Modernization Digitalization And Reformation Of Oidc Warehouses Godowns At Plot No 20 Masat Dnh ( 2Nd Call )

Key Value

Document Fees
INR 1770 /-
EMD
INR 3557615.0 /-
Tender Value
INR 25.57 Crore /-

BOQ Items

Name of Work: Infrastructure Development, Modernization, Digitalization and Reformation of OIDC’s Warehouses/Godowns at Plot no. 20, Masat, DNH (2nd Call).
Sl. No. Item Description
1Providing, Driving & installing Bored cast in situ Reinforced Cement Concrete piles of specified diametre and legth below pile cap in M-25 grade Design mix cement concret, using 20 mm graded crushed stone aggregate and coarse sand of approved quality, to carry asafe working load not less than specified, excluding the cost of casing pipe but including the cost of shoe and length of pile to be embeded in pile cap etc complete, concreting by machine batching, machine mixing, scaffolding, using admixture in recommended proportion (as per IS 9103) if approved in designmix, placing with tremie pipe, chipping off of pile top to remove laitance concrete above cut off level etc, pumping & bailling out water, with all labour material complete including crossing of tracks if required, as per approved drawing, specification & direction of the engineer in charge. Length of the pile for payment shall be measured up to the bottom of pile cap excluding the mud mat. Payment for casing pipe & reinforcement shall be paid extra.
2Conducting load testing of single pile upto following capacity in accordance with IS 2911 (Part IV) including platform and preparation of pile head or construction of test cap and dismantalling of test cap after test etc with all labour,material, tool & plants, equipment, machinery etc complete as per drawing and specification, as directed by the Engineer Inchrage.
3Pulse Echo Test (PET) for integrity testing of pile with contractor"s men, materials and machines. The rate includes cost of Inspection of site, preparation of pile head and any other unforseen cost required for the test, submission of reports in triplicate as per satisfaction of the Engineer in Charge at site.
4Providing, fabricating and installing of casing pipe for bored piles for all diametres with specified thickness of steel plate including all labour, materials, pumping & bailling out water where ever requred, complete as per technical specifications as directed in cjharge. This will include the weight of plate only and no cognizance will be given for the fittings i.e rivets & welding etc.
5Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
6Filling in foundation and plinth with murrum or selected soil in layers of 20cm. thickness including watering, ramming and consolidating etc. complete.
7Providing and filling rubbles including hand packing and filling interstices with quarry spallsas directed by the Engineer-In-Charge.
8Providing and laying cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- Graded brick bat aggregate 40mm normal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton)
9Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete.
10R.C.C. WORK. Providing and casting in situ cement concrete M-25 of trap/granite/quartzite gneiss metal for reinforced cement concrete Pile of 400 mm dia. as per detailed designs and drawing or as directed by engineer in charge.
11Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts, upto floor two level.
12Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level.
13Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level.
14Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (C) Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level.
15Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level
16Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)
17PLASTERING WORK Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (i)Cement mortar 1:3
18Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (i)Cement mortar 1:3
19EXTERNAL PLASTER Providing 20mm thick cement plaster in single coat on single or half brick walls for interior plastering upto floor two level and finished even and smooth in (i) Cement mortar 1:3 (1 cement:3-sand)
20Providing and applying two coats of apex paint of approved colour and shade to external plastered surfaces including scaffolding if necessary cleaning and preparing the surface (with additional primer coat) complete.
21Providing and applying two coats of dulux velvet touch paint of approved colour and shade to internal plastered surfaces including scaffolding if necessary cleaning and preparing the surface (with additional primer coat) complete.
22Providing cement based water proofing treatment to terrace (Indian water proofing or a like) with brick bats laid in required slope to drain the water for any span after cleaning the base surface applying a coat of cement slury and mixed with approved watering etc.
23P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for light shade.
24P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for light shade
25Trimix Flooring: Providing and laying in situ cement concrete trimix flooring M-30 grade ( 175 mm thick) with groove cuttings & sealant filling for Ground floor. Vaccum dewatering of all types & grade concrete by mechanical means including draining out the sucked excess water from concrete & then finishing the surface smooth with michanical trowelling with suitable equipment etc. complete. Carrying out mechanical trowelling of cocrete surface so as to obtain smooth shrinkage cracks free surface by providing ironite hardner or equivalent suitable hardner. Methodology to be adopted as per user manual of the equipment & as directed by Engineer- in-charge.
26Demolition and disposal of unserviceable materials with all lead and lift.(i) Lime concrete.
27Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work
28Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (
29Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) G.I.sheet roofing.
30Dismentling steel work including distempering and stacking the materials with all lead and lift.
31Providing and fixing solid core flush door in single/double leaf 35 mm. Thick, decorative types, of exterior grade, as per detailed drawing including country teak wood door frame (100 mm x 80 mm ), approved P.V.C. laminate on both faces with/without glazing etc.
32Providing and fixing window having extruded aluminum Colour Powder Coated section frame main outer size 95mm x 24mm x 1.17mm (of Jindal Section no:2459 @ wt.of 0.738 Kg/mt), horizontal Three track member size 92mm x 31.75mm x 1.30mm (of Jindal Section no:8688,@ Wt.1.07 Kg/mt), vertical member of size 92mm x 31.75mm x 1.50mm (of Jindal Section no:8933,@ Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size 40 mmx18mm x1.29mm (of Jindal Section no:8947@ wt.of 0.456 Kg/mt), vertical member of size 40mm x 18mm x 1.29 mm (of Jindal Section no:8949 @ wt.of 0.456Kg/mt/ with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc
33Providing anti termite treatment for foundation & plinth for treating soil & back filling material in emmediate contact of foundation by spreading 0.5% emulsion concantrate with the insecticide like chloropyripe as Heptachor, chlordane or as specified in etc.
34Providing and laying marble stone slab flooring over 20mm (average)base of cement mortar 1:6 (1-cement : 6 coarse sand) or L.M. 1:1.5(1- lime putty : 1.5 - coarse sand) laid and jointed with gray cement slurry including rubbing and polishing complete. (A) Marble slab 25mm thick
35Structural steel work ( Confirming to IS 4923-1997) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per the structural designs and directions of Engineer in charge
36Providing and fixing Galvanized iron sheet above truss (size, shape & pitch for corrugation as approved by Engineer -in- charge) The sheet shall be fixed using self drilling/ self tapping screws/fastners of sizewith EPDM seal-washers, complete upto any pitch in horizontal/ verticalor curved surfaces and including cutting size and shape wherever required.
37Supplying and fixing reinforced concrete heavy duty nonpressure pipes with collars for culverts including setting and joining the pipes in C.M. 1:2 watering and laying (To level of slops of I.S. 458 / 1971 Class NP4 of following internal diameter. (i) 300 mm dia.
38Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mmnominal size) foundation concrete 1:3:6 mix (1-cement : 3-coarse sand :6-Brick bats 40 + 50mm size) inside plastering15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and makingchannels in cement concrete 1:2:4 mix (1-Cement :2-Coarsesand :4-stone aggregate 20mm nominal size) finished smoothcomplete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth 0.90 metre for 150mm diameter sewer.
39Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
40Shuttering For beam. Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
41Shuttering For Slab. Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (B) Flat surfaces such as soffits of supspened floors slabs Landings and the like. (1) Floors etc.upto 200 mm in thickness.
42Shuttering For COLUMN. Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (G) Columns PillarsPosts and struts. (1) Square Rectangular Polygonal in plan.
43Shuttering For RCC Pardi Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. (C) Vertical surface such as walls (any thickness) partitions and the like including attached buttresses & string course & the like. SEPTIC TANK,SOAK PIT, DG, TRANSFORMER, EXTERNAL FLOORING (PARKING) AND DEMOLIATION WORK
44Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(A) 20mm
45Providing and fixing to wall ceiling and floor 6.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(B) 25mm
46Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia.Low density, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(C) 32mm
47Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (ii) 20mm dia.
48Providing and fixing Urinal of approved quality including connection with trap and with integral longitudinal flush pipe.(A) Squating plate pattern white earthenware 550mm x 300mm.
49Providing and fixing Kitchen sink with C.I. or M.S. brackets, painted white including cutting holes in walls and making good the same but excluding fittings. (C) Vitreous China Sink.(i) 600mm x 450mm x 150mm size
50Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm
51150 MM THK BRICK WORK Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(A) Modular (upto 10 ton)
52100 MM THK BRICK WALL Providing & constructing of 100 mm thick brick work in cm 1:4usingstandardbricks(compressivestrengthnot less than 35 kg/ cm2) well soaked in water, in true line, level, plumb,withallcourseslaidtrulyhorizontalin header bond having fully filled 10mm mortar joints, all vertical (in alternatecourse)includingM-20concrete bands100mm thick with 2Nos. 8mm dia. bars longitudinally and 8mm dia. distribution bars @ 250 c/c for width and length of wall at bottom and at 1.50m ht. ofwallabovefloorlevelincludingrakingofjoints, necessary scaffolding, finishing,curing, etc at all heights complete to the satisfaction of the Engineer-in- charge.
53GRANITE JAMB Providing & fixing of mirror polished Grey /blackgranite door frame made of aprox 3” to 5" wide stepped patta fixed with araldite over aprox. 150mm to 250mm wide (wall thickness) base patta including edge polishing, making holes etc complete as per intractions by the Site Incharge.
54LEDGE WALL IN TOILET AREA Providing & fixing of ledge 110mm thk. wall with bricks and 1: 4 sand cementand 1 side cement plastertop finish must be granite stone as per instructions and details drawings by the SITEEngineer-in-charge. And required w.c pipe shoud pass in it.
55INTERNAL PLASTER WORK Providing 10mm thick cement plaster in single coat on brick/concrete walls for interior plastering upto floor two level and finished even and smooth in (i)Cement mortar 1:3 (1- cement:3-sand)
56EXTERNAL PLASTER Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (iii) Cement mortar 1:6 (1-cement:6-sand)
57PCC ON FLOORING Providing and laying cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- Graded brick bat aggregate 40mm normal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton)
58BRICK BAT COBA AND WATER PROFING (TOILETS) Providing & fixing of Laying brick-bat coba -with approprate water proofing treatment of 112 mm average thickness consisting of 12 mm thick layer in cement mortar 1:3 with ROFF make Hyproofwater-proofing compound at the rate of one kg. per bag of cement as base. Constructing and laying brick bat coba in cement mortar 1:5 with water proofing compound at the rate of one kg. per bag of cement and having average thickness of 80 mm and finishing with 20 mm cement plaster in cement mortar 1:3 with approved waterproofing compound at the rate of one kg. per cement bag, including all leads and lifts and laid in proper slope to drain off water entirely including watta at junction of parapet and work up to height of 300mm or as directed and including finishing the top layer of waterproofing compound treatment with false marking of 30 cm x 30cm. or as directed.THIKNESS 150MM. approved by Client/Site Incharge
59PEST CONTROL ADMIN BUILDING 1ST AND 2ND FLOOR) Providing & fixing of Preconstructional Antitermite treatment by treating the bottom surface and the sides of excavation at the rate of 3 ltrs. Of emulsion concentrate of one percent concentration of CHLORPYRIFOC 20% EC, ISI approved confirming (IS 8944), (i.e. by diluting 5 ltr. of chlopyrifoc 20% EC, with 95 ltr. of water) and spraying by high volume sprayer on one square meter surface area. approved by Client/Site Incharge
60FLOORING : REVER WASH GRANITEENTRANCE STAIRES AND LANDING (ADMIN BUILDING 1ST AND 2ND FLOOR) Providing & fixing of flooring19mm thick River polished rever wash Graniteas 600MM x1200MMlaid on sigle piece with only machine cut and laid with cement mortar 1:3 and joined with cement slurry at all elevations including preparation of base, laying under bed, jointing, curing, testingincluding grinding, rubbing, polishing etc. complete in all respect as per drawing and as directed by Engineer-in-charge/deatil drawings. Basic Price RS 180/Sq.ft WASH RS 100/Sq.ft
61REVER WASH KOTA STONE ENTRANCE STAIRES AND LANDING (RATES ONLY) Providing & fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : as per drawing and as directed by Engineer-in-charge/deatil drawings
62ITALIAN MARBLE FLOORING ON STAIR (ADMIN BUILDING 1ST AND 2ND FLOOR)(RATES ONLY) Providing & fixing of Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick baseof cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing completeas per drawing and as directed by Engineer-in-charge/deatil drawings
63REVER WASH GRANITESKIRTING 75MM HT" Providing and laying on Skirting 19 mm thick River polished sGraniteas per slablaid on sigle piece with approved slab sizeonly machine cut and laid with cement mortar 1:4 and joined with cement slurry at all elevations including preparation of base, laying under bed, jointing, curing, testing including grinding, rubbing, polishing etc. complete in all respect as per drawing and as directed by Engineer-in-charge.
64REVER WASH KOTA STONE SKIRTING 75MM HT(RATES ONLY) Providing and laying on flooring19mm thick River polished kota as 600MM x600MMlaid on sigle piece with only machine cut and laid with cement mortar 1:3 and joined with cement slurry at all elevations including preparation of base, laying under bed, jointing, curing, testing including grinding, rubbing, polishing etc. complete in all respect as per drawing and as directed by Engineer-in-charge and detail drawings.
65ITALIAN MARBLE SKIRTING75MM HT (RATES ONLY) Providing and laying of Italian approved marble by Client/Site Incharge as per specification and 3 coat mirror polish,work will complete as per completion on site and approved by the site incharge
66TREAD AND RISER REVER WASHFINSIH ON STAIR CASE Providing and fixing machine cut machine polished 19MM thick app.Rever wash granitestone for Treads and Risers of steps of approved colour and shade with Chamfermoulding and TWO V" grooved line for the treads on bed of 1:3 cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete work to be done and instructions by the Site engineer/I.desiger.
67TREAD AND RISER ITALIAN MARBLEFINSIH ON STAIR CASE (RATES ONLY) Providing and laying of Italian approved marble by Client/Site Incharge with 3 times mirror polish complete work to be done and instructions by the Site engineer/I.desiger.
68SKIRTING ON TREAD AND RISER FINSIH IN REVERWASH GRANITESTAIR CASE (RATES ONLY) Providing and fixing of machine polished 19MM thick app.rever wash granite 100mm ht on starcase both side as per detail drawings and instructions by the project incharge
69SKIRTING ON TREAD AND RISER FINSIH INREVER WASH KOTA(RATES ONLY) Providing and fixing machine polished 19MM thick app.rever wash kota100mm ht on starcase both side as per detail drawings and instructions by the project incharge
70SKIRTING ON TREAD AND RISER FINSIH INITALIA MARBLE (RATES ONLY) Providing and laying Italian approved marble by Client/Site Incharge with 3 times mirror polish approved by Client/Site Incharge
71PAVING (tentative quantity) Making and fixing of heavy duty paver blocks of appropriate brand as per selection , after completing earthing, laying waste water pipes and all other related work, in mix of 1:3 cement mortar ration. approved by Client/Site Incharge
72VITRIFIED TILES 600MM X 600MM Laying and fixing ofapp.vitrified double glazed tiles including cutting toshape and level set in minimum 19 mm thick cement and sand mortar of 1:3 backing pointing flush with colored cement and grout work complete as per site instructor.as per selection)approved by Client/Site Incharge
73VITRIFIED TILES SKIRTING Laying and fixingof app.vitrified double glazed 75MM Ht,. skirting tiles including cutting toshape and level set in minimum 12 mm thick cement and sand mortar of 1:3 backing pointing flush with colored cement and grout work complete as per site instructor. (Johnson Brand as per selection) approved by Client/Site Incharge
74SADA TILE FLOORING Laying and fixingof sada tiles Gujrat make flooring with 12MM sunk as per detail drawingsincluding cutting toshape and level set in minimum 12 mm thick cement and sand mortar of 1:3 backing pointing flush with colored cement and grout work complete as per site instructor. (Sada tiles ) approved by Client/Site Incharge
75VINYLFLOORING Laying and fixing of 6MM thk carpet on sada tiles withapp.adhesive and trasition strips as per Instructions by the Site Incharge/Client.approved by Client/Site Incharge
76VINYLFLOOR SKIRTING Laying and fixing of Vinayle same shade 75mm ht modular skirting as per approvalby Client/Site Incharge
77WOODEN FLOORING (ENGENEER WOOD) (RATES ONLY) Laying and fixing of 8MM thk carpet on sada tiles withapp.adhesive and trasition strips as per Instructions by the Site Incharge/Client
78WOODEN SKIRTING (RATES ONLY) Laying and fixing of Engeneer wood same shade as flooring 75mm ht modular skirting as per approved by Client/Site Incharge
79FALSE FLOORING Laying and fixing false flooring as per detail drawings size 600MM X 600MM aluminium sections with cuttings fixing Work complete as per Instructions by Site Engineer/I.designer.
80BASIN COUNTER IN APP.GRANITE STONE Making and fixing of double Granite (As per selection) top with fixing in wall and kadappa suport as per detail drawings work complete with cutting, polishing,drilling hole for passing pipesand fixing. approved by Client/Site Incharge
81BASIN COUNTER IN APP.MARBLE (RATES ONLY) Making and fixing of double Italian Marble(As per selection) top with fixing in wall and kadappa suport as per detail drawings work complete with cutting, polishing,drilling hole for passing pipesand fixing. approved by Client/Site Incharge
82WALL DADO (TOILET) Providing and fixing of vitrified wall tiles of Kajaria/ Nitco/ Johnsonor equivalent make, required size and thickness for dado in required position with cementmortar of approved quality on plaster of 1:4 cement mortar including joint filling with white / colour cement slurry grout cleaning curing complete. Required full height two lines in highlighter tiles.BASIC RATE-RS 60/Sq.ft. approved by Client/Site Incharge
83ANTI SKID FLOORING TOILET AREA Providing and layingof 10 mm thk non-skid fully vitrified tiles of make Kajaria/Nitco/Johsonof BOSS Profile limited" or equivalentin flooringand skirting over 30 mm thick under bedof 1 part cement and 3 parts coarse sand by weight mixed with sufficient water, complete as per specification and selection by the Site Engineer or I designer detail drawings and instructions.BASIC RATE 85/Sq.ft. approved by Client/Site Incharge
84PANTRY ABOVE COUNTER DADO TILE Providing and fixing of 300mm x 600mm wall dado tiles above kitchen counter of Kajaria/Johnson/Nitco as per selection on 12mm thick bed in cement mortar ratio of 1:3. work finish with cutting,fixing,and grouting.BASIC RATE-RS 60/Sq.ft. approved by Client/Site Incharge
85PANTRY BELOW COUNTER SADA DADO Providing and fixing 12mm thick 300mm x 300mm wall dado tiles below kitchen counter of ivory white Gujrat make on 8mm thick bed of cement mortar ratio of 1:3. approved by Client/Site Incharge
86PANTRY COUNTER Making and fixingof Granite (As per selection) top with fixing in wall and kadappa suport as per detail drawings work complete with cutting, polishing,drilling hole, front facia for passing pipesand fixing. approved by Client/Site Incharge
87PLUMBING AND SANITARY INTERIOR WORK ONLY Providingandfixing ofin positiontestedheavydutytype chromium plated(CP) brasslongneck bib cocksincludingsockets,union,nutsetcallcomplete-15mm nominal bore.,PILLAR COCK Make:JAQUAR-CON-CHR 189KN (LONG NECK) or PARRY Ware make can be considered ,BIB COCK Make: JAQUAR-CON-CHR 037KN,ANGLE COCK Make:JAQUAR-CON-CHR 053KN Providingand fixing in positionheavy dutybrass stop cock of approvedquality including all specials etc all complete - 15mmnominal bore.Make:JAQUAR-CON-CHR 069KN, 20 mm dia,25 mm dia,50 mm dia,Providingandfixing 610mmx127mmx6mm thkclear glasswithC.P Guard rails and mountedonC.P. brackets etc all complete., Providing and fixing 20mmdiameterstainlesssteeltowelrails(600mmX20mm) all complete.Make:JAQUAR-ACN-CHR-1111NM,Providing and fixing 20mm dia chromium plated M.S. pipeswall mounted towel rod withC.P.Brackets etc all complete.Make:JAQUAR-ACN-CHR-1121BN,Providing and fixing C.P. soap holder mounted with C.P. screws etc all complete. Make:JAQUAR-ACN-CHR-1131N Providingand fixing stainless steel / C.P. liquid soapdispenser. Dispenser shall be round and easily revolving with removable threadednozzle andmountedon C.P. brackets etc all complete. Make:JAQUAR-ACN-CHR-1135N Providing and fixing glazed vitreous wall mounted paper holder with suitable cover cum cutter fitted with CP screws etc. sllcomplete.Make:JAQUAR-ASH-CHR-1551,Providing and fixing chromium plated brass Health Faucets with 15 or 20 mm inlet all complete.CERA:F8030101 , 5000litres capacity 2 nos. SANITARY WORKS WASH BASIN MODEL NAME AND NUMBER :White, Jaguar Range :Florentine, Code :FLS-WHT-5701 Description : Under counter Basin with Fixing Accessories, Size: 555x425x195mm, Shape : Oval,BOTTLE TRAP MODEL NUMBER:aquar Brass Bottle Trap Heavy (Chrome Finish, 10x10x10 cm) Providing and fixing stainless steel kitchen sink of size 16""x16""x8"" anti sound conforming to IS: 13983 including all fittings etc. all complete. USE Neelkanth Inset NK SL 10 SB 2 10 Single Bowl, Floor mounted MAKE:JAQUAR Florentie :FLS-WHT-5953UFSM,jaquar 32 mm Flush Valve Dual Flow FLV-CHR-1039 wall mounted, 75mm dia pipes of SWR Grade,110mm dia pipes of SWR Grade,160mm dia PVC pipes 6kg/Cm2,200mm dia PVC pipes 6kg/Cm2, 150mm dia,250mm dia,300mm dia,500mm dia",#VALUE!,"Providing and fixing circular heavy duty C.I. manhole cover of 600 mm diaof minimum 50 Kg rating with frame etc. all complete. 100x100mm P or S Type.,150x100mm P or S Type.,150x150mm P or S Type., Providingand fixing C.I. floor traps withC.P jalli Anti Cockroches (Chilli Brand or equivalent all complete.,Providingand fixing heavy duty UPVC floor traps withC.P jalli all complete.,Providing and installing approved brand single tap water cooler of 150 L cooling capacity all complete. Incase single Tap is unavaliable use Double Tap ofBlue star or equivalent
88ROLLING SHUTTERS Providing and fixing of M.S rooling shutters as per 18 guage sheet for the façade opning rate shall include transportation on site fixing on site as per instructions by the Site Incharge Size 1500mmx3100mm
89WOODEN DOOR( D1) SIZE: 1200MM X 2400MM Providing and fixing of Door Frame: 100mmx 50mmHard wood timber door frame ,melamine polishedShutter:38mm flush door finished with 1.2MM thk Merino Brand Laminate as per Selection by the Site Incharge Hardware :,Hinges - Floor spring with path fittings - Dorma ,Lockset - Dorma with key opening on the outside.,Door handle - Dorma DPH 207 T (STRAIGHT) both inside and outside. Size - 3" long ,view pane: 48"" x 6"" x 1 nos each leafwith 6mm toughned glass fixing with beading wooden patti finish with polish
90DOUBLE LEAF OPNABLE DOOR WITH VIEW PANEL (D2) SIZE ; 1200MM X 2400MM Providing and fixing of Door Frame 230mmx 19mm thk, double patti App.Granite frame Indianpolished finish as per detail drawings ,Shutter: 38mm flush door finished with 1.2MM thk Merino Brand Laminate as per Selection by the Site Incharge Hardware :,Hinges -Palladium hinges. ,Lockset - Cylindrical lock fixed in granite jamb.Dorma Brand/Godrej,Door handle -Dorma DPH 207 T (STRAIGHT) both inside and outside. Size 18"",view pane: 18""x 9"" x 2 nos with 6mm toughned glass fixing with beading wooden patti finish with polish
91DOOR WITHVIEWPANEL (D3) 900MM X 2400MM Providing and fixing of Door Frame: 100mmx 50mmHard wood timber door frame ,melamine polished,Shutter: 38mm flush door finished with 1.2MM thk Merino Brand Laminate as per Selection by the Site Incharge,Hardware :,Hinges - Floor spring with path fittings - Dorma ,Lockset - Dorma with key opening on the outside.,Door handle - Dorma DPH 207 T (STRAIGHT) both inside and outside. Size - 18" long ,view pane: 48""x 6"" x 1 nos with 6mm toughned glass fixing with beading wooden patti finish with polish s per detail drawings and instrutions by the site incharge
92DOOR FOR CABINS (D4) 900MM X 2400 Providing and fixing of Shutter: 38mm flush door finished with 1.2MM thk Merino Brand Laminate as per Selection by the Site Incharge,Hinges - Floor spring - Dorma ,Lockset - Dorma with key opening on the outside.,Door handle - Dorma DPH 207 T (STRAIGHT) both inside and outside. Size - 18" long
93EMERGENCY DOOR (E1) 1200MM X 2400MM Providing and fixing of Door Frame 230mmx 19mm thk, double patti App.Granite frame Indianpolished finish as per detail drawings Shutter: 38mm flush door finished with 1.2MM thk Merino Brand Laminate as per Selection by the Site Incharge
94TOILET DOORS : D5-SIZE750MM x 2100MM Providing and fixing of Door Frame 150mmx 19mm thk, double patti App.Granite frame Indianpolished finish as per detail drawings Shutter : 35MM thk Solid Flush Door with both side 1.2MM thk Marino Laminates as per Selection By the Site Incharge. Hardware :Hinges - Palladium 5"" lenghth Hinges.,Door handle - Dorma THtype 123 with lock.,Door Closer: Concealed Dorma Door closer ITS 96
95WINDOW SLIDINGWITH MOSQUITO NET (2100MMX 1100MM) Providing and fixing of SS Mosquito mesh in anodisedAluminium section (anodic film must not be less than 15 microns i.e. AC-15 as per IS, the anodising must be scaleted by keeping the anodized section in boiling de-anodized water for a period of one hour) aluminium shutter fixed in sliding / openable / fixed windows conforming to IS:1948-1961 as per drawing and directed by Engineer In Charge. (Note: For Aluminum Sections, total weight shall be upto 3.5 kg/sq.m.)
96WINDOW JAMB IN GRANITE FOR TOILET DOORS Making and fixing of granite jamb in windowsinsideapproved granite and external indian marble work complete with all cutting polishing fixing on site with detail drawings and instructions by the Project incharge.
97VINTILATION WINDOWS WITH LOUVERS AND EXHOUST WINDOWS (SIZE-2"-0" X2"-6") Providing and fixing of openable window as per detail drawings with aluminium frame and frosted glass
98GRILL FOR WINDOWS SIZE ( 8"-0"X 4"-0") Providing and fixingof 10MM squarebar M.s grill with details drawings and required 2 coat of redoxide work complete with all cutting grinding fixing etc and instructions by the project incharge
99EXHAUST DUCT WITH GRILL Making and fixing of 230mmx230 mm MS duct for exhoust fans inside the pop with all cuttings fixing weldings and holes in wall, the work will complete as per instructins by the Site incharge and detail drawings.
100FURNITURE WORK WOODEN PARTITION Making and fixing of 65mm aluminium boxsections partition with 600MM x 600MM framing with screwing fixing 12mm play on both sidesheets and finish with laminate as per detail drawings
101GLASS PARTITION Providing and fixingof 12MM thk toughned glass on Aluminium heavy profile chanel in botton and above woodenframe work will complete with all nessesary fittings and hardware finish with frosted dsigner film as per detail drawings
102PARTITION ABOVE CEILING Making and fixing of wooden partition above gypsum ceiling with toung and grove fitting finish with polishby the Site incharge and detail drawings.
103HILUX DOUBLE GLAZE PARTITION (RATES ONLY) Making and providing of65mm aluminium section with 12mm thk Hilux doble glaze partition as per detail drawings and instructions by the Site incharge
104CASH COUNTERS Making and fixingof cabin in MR 710 ply with aluminium sections grid finish with app. Laminate 1.2mm internaly and externaly and ply door will be hang with door hinges finish with beading atti and polish , lock cylendrical,above cabinet 12 mm thk glass partition with viewing provision and beding wooden patti finish with app polish, the work completeas per detail drawings and instructions by the Project Icharge
105BOTTLESDISPLAY UNIT Making and fixingof full ht disply unit with 19MM MR 710 gradeply with all necessaryjoints and finishes as per detail drawings which includes 19mm thk. ply on front side, internal laminates and external 1.2MM thk laminates/veneer finish bottom of unit will be storage with opnable shutters hanges on Z" poladium brand or equal brandhenges,above part shutters will be in 8mm toughned glass shutters all work complete as per detail drawings and instructions by the Site incharge.
106DISPLY COUNTER Making and fixing ofdisplay counter in 19mm thk ply with drawers and shuttersinternal lainate will be .8mm and external laminate will be 1.2mm thk ss handles as per approvaland above part will make in 12mm glass fixing in 2"2" wooden patti all work will finish as per detail drawings and instructions by the Project inchargesize 3191mm x 800mm deep 500mm
107WORKINGTABLEWITH SIDE CREDENZA (MANAGERS CABIN) Making and fixing of Managers and executiontable with 19MM ply with all necessary joints and finishes as per detail drawings which includes 40MM double ply on front side, internal Egg white internal laminates and external 1.2MM thk laminates internal .8mm thk laminateand necessary all hardwares hettech/Godrej/dorma hardware finish as per detail drawings and instructions by the PROJECT INCHARGE Top of 2100MM X 750MM HT750MM single piece with water-cut edge binding. PVC edge banded, with wire manager on top.,Keyboard Rollout Tray.,6MM thk, Tinted Mirroron top of table with adge polish ,SIDE CREDENZA,with side credenza 2"6"" x 1"4"" x 2"6"" refer detail drawings or as per Architects instructions.
108MODULAR POPUP BOX Making and fixing ofRequired 5"x 10" modular popup box for switch and sockets box on table as per detail drawings and Instructions by the Site Incharge SIZE OF TABLES F.Incharge cabin 1 NOS -2100MMX750MMX750MM CABIN 1-1730MMX750MMX750MM -1NOS CABIN 2-2100MM X750MM X750MM 1-NOS
109RECEPTION TABLE Making and fixing ofL" shape Reception table with 19MM ply with all necessary joints and finishes as per detail drawings which includes 40MM double ply on front side, double ply hand restinternal laminates and external 1.2MM thk laminates/3MM veneerinternal .8mm thk laminateand top and facia will finish in corian necessary all hardwares hettech/Godrej/dorma hardware finish as per detail drawings and instructions by the PROJECT INCHARGE size 2400MM X 700MM X H 1500MM Required 5"x 10" modular popup box for switch and sockets box on table as per detail drawings and Instructions by the Site Incharge
110L" SHAPE WORKING TABLE WITH SIDE CREDENZA (WORKS STAITION) Making and fixing of with 19MM 710 mr ply with all necessary joints and finishes as per detail drawings which includes 40MM double ply on front side, internal Egg white laminates and external 1.2MM thk Green Lamlaminates and internal .8 mm thk laminate necessary all hardwares hettech/Godrej/dorma hardware finish as per detail drawings and instructions by the PROJECT INCHARGE Top of 1200MM X 600MM TOP 750MM HTsingle piece with water-cut edge PVC edge banded, with wire manager on top, Keyboard Rollout Tray.
111SIDE CREDENZA with side credenza 900MM x 450MMx 750MM making in 19mm thk mr ply 710 finish with 1.2mm Green lam or equivalent laminate from out side and internal .8 mm laminate marino brand refer detail drawings or as per Architects instructions. Providing and fixing POPup electrical box as per discribedTabletop Hydraulic Pop Up Box / Cable Cubby 8 Module Multi-Functional Desktop Pop up Box
112LENEAR WORKS STATION TABLES (RATES ONLY) Making and fixingModular with 19MM mr 710 ply with all necessary joints and finishes as per detail drawings which includes 40MM double ply on front side, internal Egg white laminates and external 1.2MM thk laminates and necessary all hardwares hettech/Godrej/dorma hardware finish as per detail drawings and instructions by the PROJECT INCHARGE Top of 1200MM X 600MM TOP 750MM HTsingle piece with water-cut edge PVC edge banded, with wire manager on top. Keyboard Rollout Tray. PEDESTRAL 2 NOS 150MM HT DRAWERSAND 1NOSFILE HT DRAWR
113Provisding and supply Godrej ale M.s Working table with all locks and keySize-1200m x 600mm height as per standard ADD 2 NOS TABLE FOR CASH COUNTERS as per above spesification and detail drawings Providing and fixing POPup electrical box as per discribed Tabletop Hydraulic Pop Up Box / Cable Cubby 8 Module Multi-Functional Desktop Pop up Box
114SECURITY CABIN WORKING TABLE Making and fixingof Modular with 19MM mr 710 ply with all necessary joints and finishes as per detail drawings which includes 40MM double ply on front side, internal Egg white laminates and external 1.2MM thk laminates and necessary all hardwares hettech/Godrej/dorma hardware finish as per detail drawings and instructions by the PROJECT INCHARGE Top of 2500 MM X 600MM TOP 750MM HTsingle piece with water-cut edge PVC edge banded, with wire manager on top. Keyboard Rollout Tray. PEDESTRAL 2 NOS 150MM HT DRAWERSAND 1NOSFILE HT DRAWR as per standards Providing and fixing POPup electrical box as per discribed Tabletop Hydraulic Pop Up Box / Cable Cubby 8 Module Multi-Functional Desktop Pop up Box
115FULL HEIGHT DOCUMENT STORAGE Making and fixingofFull ht, document storage Double leaf shutter with internal selves and drawer with includes 19MM thk ply and back 9MM ply ,internal .8MM egg white and external 1.2MM thk app. marino brand app.laminate finish with includes tower bolt,godrej locks,paladium hinges handles by dorma work complete as per detail drawings and instructions by the project incharge 1- size 2638mm x 3770mm DEEP 450MM 2- Size-2270mm x H 3770MM DEEP 450MM
116PANTRY UNDER COUNTER AND ABOVE COUNTER STORAGES Making and fixing of Under counter storage in 19MM thk.ply with Drawers,shutters, kitchen trolleys 210 GRADE SS ,profilehandles , etc. all nessesary joinery and fixing finish with internal 0.8MM Marino brand app.laminate and External 1.2MM thk Laminate as per Kitchen detail drawings and Instructions by the Site incharge Making and fixing middle counter and above counter as per detail drawings with Hydrolic maruti henges paladium henges and internal and external laminates finish as per detail drawings and Instructions by the site Incharge OIDC PANTRY -SIZE 1200MMX 800MM -DEEP 600MM MIDDLE 1200MM X 500MM DEEP 300MM OVER HEAD STORAGE -1200MMX 600MM-300MM
117HALF HT STORAGE Making and fixing of HALF ht, document storage 19MM thk701 ply and back 9MM plywith internal selves and drawer with includes internal .8MM egg white and external 1.2MM thk app. Marino brand laminate finish with includes tower bolt,godrej locks,paladium hinges handles by dorma work complete as per detail drawings and instructions by the site incharge. SIZE 3700MM X 1200MM X DEEP 450MM 1000MM X 1200MM X DEEP 450MM X 2 NOS
118UNDER COUNTER STORAGE TOILETS Making and fixing of 19MM thk MARIN710 ply with all nesessary heavy poladium dorma or euivalant brandfittings and hardware includes J" handles as per instructions by the Architect and site engineer OIDC- GENTS TOI. SIZE 1649MM X 600MM OIDC-LADIES TOI. SIZE 900MM X 600MM DD- COMMON TOI. SIZE 1200MM X 600MM
119CEILING: MODULAR CEILING Supply , installation , testing & commissing of Armstrong/ Everest Ceiling/grid ceiling Providing fabricating and fixing of false ceiling at all height as directed of 600 mmx 600 mmx 15 mm Armstrong/ Everest mineral fiber tegular ceiling tiles laid on Armstrong/ Everest prelude XL exposed grid system with 9 mm wide T section flanges color white. The frameworkcomprises of main runner spaced at 1200 mm centre. Hanger (GI wire) to be fixed by approved roof plug and screws etc. The last hanger at the end of each main runner should not be greater than 450 from the adjacent wall. Flush fitting 1200 mm long cross tees (with double stitching )to be interlocked between main runner at 600mm center from 1200x600mm modules. Cut cross tees longer than 600mm to be supported independently 600mm x 600 mm modules to be formed by fitting 600 mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong/ Everest wall angle secured to walls at 450 mm maximum centers.
120CALCIUM SILICATE CEILIG (RATES ONLY) Providing and fixing Calcium silicate sheets with all spacifications and standards with detail drawings and instructins by the Site Incharge.
121METEL SHEET CEILING (TOILET AREA) Providing and fixing of Metel sheet ciling with all nessesari grids as per standards and instructions by the Site incharge
122FALSE CEILING Providingand Fixing12mmthick Gypsumboardplain/perforatedfalse celing channel grid (600x600mm)of India Gypsumor equivalentmake in plan or elevation with aluminiumgrid, metal suspension system, anchor fastener adjustable hangers etc. including two or more coats of acrylic emulsion paint of approved colour to give an evenshadewithsmooth finishallcomplete.as perarchitectural designand detail.metal suspension system as per ASTM C-635 shall be hot dipped M.S.galvanized (grade 180 as per is :277) nominal size of T-section shall be 24 x 38 mmor 24 x 25 mmcross runners.24mmwide exposedflange surfaceshall be permanently color coated.suspension system shall be as per manufaturer"s specificationsupportedovermovmentplatform.Theworkto be completeas per specifications,drawings and direction of engineer.
123L Shape vertical band for cove light in POP Providing and fixing of 38mm ht L shape border for cove lightas per detail drawings and instruction byf the site Engineer in gypsum sheet.
124NICHE IN POP FOR PROJECTEDBLIEND WITH CURVE LIGHT PROVISION Making and fixing niche in pop ceiling as per drawings with chanel suport and
125GROVE IN POP (TENTATIVELY) Required 6MMx6MM grove with finish as per instructions by the Architect/site incharge
126GALA CUTTING (RATES ONLY) Making and cutting gala for ceiling light and finish with pop as per given sample by the client.Work complete with all cutting filling and adjustablibility.
127POP PUNNING ON NEW WALLS Providing and applying plaster of paris ( super fine quality ) punning with minimum thickness of 12 mm and finish the surface smooth in line and level including scrapping and hacking the existing finished surfaces, scaffolding etc. complete .
128PLASTIC PAINT Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
129LUSTER PAINT Laying and applying of The wall surface shall be prepared by applying Birla putty. Lambi finish shall be given 3 times.Ready the base with applying proper polish with paper.Primer sahll be applied to the wall surface.3 coat approved Luster paint by Asian paints shall be applied.the rate should be include cleaning,removing paint patches etc.
130ROYAL BY ASIAN PAINT (RATES ONLY) Laying and applying of Royal paint by Asian Paints brand ON walls as per all conditions and specifications or instructions by the Site Incharge.
131EXTERNAL PAINTING (RATES ONLY) Providing and applying of Finishing wall with water proofing cement paint of on wall surfaces (Two coats) to give an approved brand and manufacture and of required shape even shade after thoroughly brushing the surface to remove all dirt and remains of loose powered materials.
132ENAMEL PAINTING.(RATES ONLY) Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint, interior to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping.
133WALL PAPER Providing and fixing of Prepering various surfaces for fixing of wall paper. Applying double coat of primer on plywood surfaces with cleaning and masking of fixed wall paper complete. Follow-up with appointed vendorfor wall paper for confirming his timings shall be in contractors scope.
134ROLLER BLINDS Providing and fixing ofapproved colour and patterns Roller bliends withroad as per selection by the Project incharge/Client
135FABRIC CURTAINS (RATES ONLY) Providing and fixing & approved of clour,pattern and model of cutains with fixing details as per selection by the Project Incharge/Client
136PUSH BACK REVOLVING CHAIR (FOR MANAGERS AND ABOVE) Providing and fixingof FULLback revolving chair with approval by the project inchargand instructions suplaying to site as per selection by the Project Incharge/Client
137STAFF ROVOLVING CHAIRS Providing and fixingof Half back revolving chair with approval by the project incharge and instructions suplaying to site as per selection by the Project Incharge/Client
138CHAIR BENCHES Providing and fixingof 3-Seater Waiting Area BenchChair Metal Chair with PU Cushion Leatherette Office Visitor Chair  as per selection by the Project Incharge/Client
139NAME BOARDS Supply and fixing18"x12" X 3letters and 12"x8" x 13 letters respectivelyapp font leters in Acrylic with light provision in it and fixing with 1.5" hollow M.Sbox sections frame with welding,fixing,screwing all work complete as per detail drawings
140AQUAGUARD (FOR OIDC OFFICE PANTRY) Providing and instalingof Aquaguard Select Dr aquaghar + UV Hot comes equipped with unique e-boiling+ technology that ensures every drop of water is as healthy and safe as water boiled for a minimum of 20 minutes. For areas with low TDS water (<200 ppm) Aquaguard Select Classic+ UV Hot helps you to get on demand Hot, Warm & Ambient water 3 Customised installation options Unique e-boiling+ technology Auto shut off Intelligent purity sensor system Equipped with most advanced Technologies Active Copper Maxx™, Biotron™ and Mineral Guard™ -BASIC RATE 16000
141WATER COOLER FOR DRIVERS AND LABOURS providing and fixingof Storage water dispenser - Floor mount model / Suitable to be connected with water purifiers - 80 ltrs storage capacity - Hot / Cold / Ambient Water dispense - Food grade Stainless Steel Tank ( SS304 ) - LED display Features - Stainless steel tank for corrosion resistance and better hygiene - Long lasting plastic front panel and faucets - Conveniently removable drip tray - Efficient cooling even in hot climatic conditions - Power consumption - 1575 Watts - Smart Ergonomic Design - Quiet operation - Child lock for hot water outlet
142Providing and fixing LCD disply screen on showroom area with light provision inside and data cable.as per instructions by the Project Incharge
143GLASS PARTITION IN URINAL Providing and fixing 30"x 18" 12mm thk, toughnedmachine polish and support brackets Size 850mmx400mm as per detail drawings
144MIRROR fixing in Toilets providing and fixingof 1500mm x 1580mm 6mm thk mirror with SS studs as per instructions by the Site incharge. Size : 1) 1200mmx 1580mmx 2 nos 2) 900mm x 1580mm - 1nos
145DUSTBIN Supplying and fixing of 2 seator wooden shade without back 5" long and 18" height with 16 " to 20" wedth out door benches with plant box provision as per refrence image work complete as per instructions by the Project Inharge Basic coat-Rs 15000
146Stair case M.Sdouble/ single flates Making and fixing m.S stair casewith 38mm chanel and angles and 4 mm thick M.S sheet anti skid on treadsand 1000mm height railing with 2 nos 19mm square .ms pipe and 1 round 50m dia round shape hand support pipe on both sides of stair horizontally running through the stairs as per detail draings and Instructions by the Site Incharge
147HAND RAILIG M.S Providing and fixing M.S hand railing made of hollow tubes channels,plates etc including welding grinding buffing polishing and curvature(whertever required) and fittting the same with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
148ELECTRICAL LIASON WORK SCOPE OF ELECTRICAL LIASON CONTRACTOR : GETTING LOAD SANCTION FOR THE PROPOSED OMNIBUS INDUSTRIAL DEVELOPMENT CORPORATION AT MASAT-SILVASA, TRANSFORMER CAPACITY: 11/0.433kV, 315kVA CONNECTED LOAD:353.55kW & CONTRACT DEMAND:215.36kVA, Preparation of application for power sanction & submit it to SEB -Assist client to arrange & prepare all the required documents to be submitted to SEB alongwith application.-Make necessary changes, if required by SEB, in the electrical drawings, already made by our consultants, so that these shall be submitted for necessary approval to SEB.-Preparing the feasibility report. - Follow up with SEB & getting power sanction in scheduled time.- Follow up with SEB & getting the consumer power agreement signed within scheduled time. - Follow up with SEB in getting required rating of CT/PT, HT meters tested, installed on site providing & fixing with all accessories, again testing on site & sealing the meters for taking into service inclusive of satisfactory load tests by SEB Testing Team. All follow up not mentioned in above scope but required to complete the job in totality with SEB. All technical, regulatory assistance & guidance to M/S.OMNIBUS INDUSTRIAL DEVELOPMENT CORPORATION( Client ) to achieve the target date of power. Client & liaison authoruty shall agree to a schedule for completion of above activities & getting power sanction & power release for the same.( Including all charges for gettingpower supply upto company premissess )
149Liasioning with Electrical Inspector for approval of distribution scheme & drawings. - Liasioning with Electrical Inspector for approval of Electrical Installation at site & obtain clearance for energizing Power.
150HT SWITCH YARD Supply, Installation, testing & commissioning of of 11kV GOS with two pole structure at HT yard point of supply. Including Following Scope…...... 11kV GOS 20A rating 31.5kA with centre post rotating,horizontal double break isolators, upright mounting manually operated with mechanism operated from the floor level with earth switch required for normal operation. 11KV CT & PT Unit A set of nine stack support insulators,each stack consists of one basic units of 11kV solid core insulators for a BILof 325kV having suitable creepage distance and cantilever strength of 6KN/25mm. A set of 6 nos rigid type bimetallic terminal connectors suitable for single ACSR ZEBRA conductor Hard dipped galvanized lattic type mounting steel structure completed with hardwares. GOS & All Accessories including Structral Steelshall be suitable for Outdoor Application & its make-model no as per SEB approval. Make - KIRON TEXTILE / PACTIL / PRAGATI
151INSTALLATION OF COMPACT SUBSTATION (CSS) Installation, testing & commissioning of 315 kVA, 11 /0.433kV outdoor type CSS having 11kV RMU, 315kVA oil type transformer with ON load tap changer & LT Breaker compartment scope including unloading,shifting to intermediate stores, if site is not ready or to installation at site, checking of foundation level, welding of stoppers on foundation channels, topping up with oil, testing of oil for dielectric strength including all labour and materials. Following precommissioning tests are included ,in scope of contractor,Insulation test,Ratio test,Oil dielectic test,Vector Group Test,H.T.test for termination,Functional Test Fortransformer protection device.,Approximate Dimensions:-4500 ( L ) X 2500 ( D ) X 2400 ( H ) in mm. Make - VOLTAMP / SUDHIR / RAKESH TRANSFORMER / KIRLOSKAR
152Supply & spreading, Levelling & rubble soiling the open switchyard with 1"size round metal 150mm thick layer at point of supply for two pole structure yard.
153Chain Link Fencing with Gate for Two Pole/ CSS & DG Set Supply & Installation of Chain Link Fencing with Door as per Local Electricity Board Norms at point of supply for two pole structure yard.Immobilizer security system in the event of emergency stop or power failure.
154LOW VOLTAGE SWITCHGEAR INSTALLATION, TESTING AND COMMISSIONING OF PTA TYPE LT PANELS AS PER IS 60439-I Installation, testing and commissioning of following 415 voltswitchboards / control panelsincluding unloading, shiftingto intermediate stores, if site is not ready and/or to installation site,unpacking, physical inspection, assembly under supervisionand instruction of panel manufacturer. Switch Board Designation MAIN PCC PANEL Voltage :415 V. Construction :Single Front Ref. SLD No.DT-22101-EL-09-101-Rev-1 Date - 09.11.2021 Ref. Speci.:- Doc. No. Approximate Dimensions:- 2500 ( L ) X 800 ( D ) X 2400 ( H ) in mm. Approximate Weight:- 3500 Kgs
155Switch Board Designation:130kVAR THYRISTOR BASED APFC PANEL Voltage :415 V. Construction : Single Front.Ref. SLD No.DT-22101-EL-09-102, Rev-0,Date -09.11.2021 Ref. Speci.:-Doc. No. Approximate Dimensions:- 2500 ( L ) X 1000 ( D ) X 2400 ( H ) in mm. Approximate Weight:- 2000 Kgs
156MCB DISTRIBUTION BOARDS Supply,Installation , testing and commissioning of following distribution boards. MCB distribution boards shall be totally enclosed with double door, vertical, surface/recessed mountingtype,outer door shall be hinged type with push in type spring / magnetic lock, inner door shall be fixed up with screws with cutouts for MCB operation,copper busbar of at least 1.5 times the rating of incomer MCB / MCCBwith adequate space for termination of incoming and outgoing cables, removable undrilled top & bottom gland plates,suitable for wall, column mounting type. The incoming MCCB shall be provided in separate compartment. The MCCB shall have front drive mechanism and door interlock. The DB shall be fabricated out of 1.2 mm thick CRCA sheet steel . DB shall be completely wired up, upto incoming and outgoing terminals by PVC insulated flexible copper wire of adequate rating. All ELCB installed inLDB shall be rated for 30 mA leakage current. All MCB in LDB shall be suitable for Lighting Power ( Curve B ) Note:-KA Rating of DB having Incomer asMCB shall be 10kA& DBhaving incomer as MCCB shall be 25kA for Incomer MCCB, DB & for its all outgoing MCB kA rating shall be 10kA.Make- LEGRAND / SIEMENS / SCHNEIDER / L&T only . Lighting Distribution Board 12 WAY E-TPN DB WITH PPI KIT , IP 43,Tag No. : LDB #,Incomer : , ? 63 A TPN MCB ,Outgoing :,? 3 Nos 63A DP MCB+ELCBone in each Phase 30mA,? 24 Nos. 16 A SP MCB Eight in each phase,The above complete with interconnections, etc.
157Lighting Distribution Board ( For 1 No Warehouse & 1 No Admin ),12WAY E-TPN DB WITH PPI KIT , IP 43,Tag No. :LDB #,Incomer : , ? 32 A TPN MCB ,Outgoing :,? 3 Nos 32A DP MCB+ELCBone in each Phase 30mA,? 18 Nos. 16 A SP MCB Six in each phase,The above complete with interconnections, etc.
158Lighting Distribution Board 08 WAY E-TPN DB WITH PPI KIT , IP 43,Tag No. :LDB #,Incomer : , ? 32 A TPN MCB ,Outgoing :,? 3 Nos 32A DP MCB+ELCBone in each Phase 30mA,? 12 Nos. 16 A SP MCB Four in each phase,The above complete with interconnections, etc.
159Lighting Distribution Board for Normal / Emergency ( For Warehouse & Admin ),12 WAY SPN DB , IP 43,Tag No. : SUB LDB # / SUB ELDB # ,Incomer : , ? 32 A DP MCB + ELCBin Phase 30mA,Outgoing :,? 8 Nos. 16 A SP MCB Eight in phase,The above complete with interconnections, etc.
160Lighting Distribution Board for Normal / Emergency 12 WAY SPN DB , IP 43,Tag No. : SUB LDB # / SUB ELDB # ,Incomer : , ? 32 A DP MCB + ELCBin Phase 30mA,Outgoing :,? 6 Nos. 16 A SP MCB Six in phase,The above complete with interconnections, etc.
161Lighting Distribution Board for Normal / Emergency 08 WAY SPN DB , IP 43,Tag No. : SUB LDB # / SUB ELDB # ,Incomer : , ? 32 A DP MCB + ELCBin Phase 30mA,Outgoing :,? 4 Nos. 16 A SP MCB Four in phase,The above complete with interconnections, etc.
162Switch Board Designation:Street Light Distribution Board ( for External Lighting ) Voltage :415 V.,Construction :Single,Incomer : ,? 32 A TP+N MCB with O/L &, S/C Protection. 10kA for 1 sec.,Outgoing :,? 8 Nos. 10 A TP+N MCB ,Rest of materials like. .. Timer, Accessories & etc as per attached SLD. ,Location :Security Cabin,Ref. SLD No. DT-22101-EL-E05-101
163Power Distribution Board Supply,Installation , testing and commissioning of following distribution boards. MCB distribution boards shall be totally enclosed with double door, vertical, surface/recessed mountingtype,outer door shall be hinged type with push in type spring / magnetic lock, inner door shall be fixed up with screws with cutouts for MCB operation,copper busbar of at least 1.5 times the rating of incomer MCB / MCCB,with adequate space for termination of incoming and outgoing cables, removable undrilled top & bottom gland plates,suitable for wall, column mounting type. The incoming MCCB shall be provided in separate compartment. The MCCB shall have front drive mechanism and door interlock. The DB shall be fabricated out of 1.2 mm thick CRCA sheet steel . DB shall be completely wired up, upto incoming and outgoing terminals by PVC insulated flexible copper wire of adequate rating. All ELCB installed inPDB and TPDB shall berated for30mA( As per mention in SLD) leakage current. All MCB in Power DB shall be suitable for Motive power ( Curve C ) Note:-KA Rating of DB having Incomer asMCB shall be 10kA& DBhaving incomer as MCCB shall be 25kA for Incomer MCCB, DB & for its all outgoing MCB kA rating shall be 10kA.Make- LEGRAND / SIEMENS / SCHNEIDER / L&T only .Power Distribution Board- Single Phase( Miscellaneous Raw SPDB ) 16 WAY E-TPN DB WITH PPI KIT , IP 43,Incomer : ,63 A TPN MCB,Outgoing :,? 3 Nos, 63A DP MCB+ELCBone in each Phase 30mA,36 Nos, 20 A SP MCB Twelve in each phase,The above complete with interconnections, etc.
164Power Distribution Board- Single Phase(Miscellaneous Raw Power SPDB ) 12 WAY E-TPN DB WITH PPI KIT , IP 43,Incomer : ,63 A TPN MCB,Outgoing :,? 3 Nos, 63A DP MCB+ELCBone in each Phase 30mA,24 Nos, 20 A SP MCB Eight in each phase,The above complete with interconnections, etc.
165Power Distribution Board- Single Phase(Miscellaneous Raw Power SPDB ) ( For warehouse ) 08 WAY E-TPN DB WITH PPI KIT , IP 43,Incomer : ,63 A TPN MCB,Outgoing :,? 3 Nos, 63A DP MCB+ELCBone in each Phase 30mA,12 Nos, 20 A SP MCB Four in each phase,The above complete with interconnections, etc.
166Power Distribution Board( SPDB +TPDB ) Incomer : 08 WAY V-TPN MCCB DB WITH PPI KIT , IP 43,125 A TPN MCCB With O/L, S/C & External Earth Fault Protection,Outgoing :,? 3 Nos, 63A DP MCB+ELCBone in each Phase 30mA,12 Nos, 20 A SP MCB Four in each phase,03 Nos, 32A TP MCB,The above complete with interconnections, etc.
167Power Distribution Board- Single Phase ( UPS Power USPDB) 12 WAY E-TPN DB WITH PPI KIT , IP 43,Incomer : ,63 A TPN MCB,Outgoing :,? 3 Nos, 63A DP MCB+ELCBone in each Phase 30mA,24 Nos, 20 A SP MCB Eight in each phase,The above complete with interconnections, etc.
168Power Distribution Board- Single Phase( UPS Power USPDB) ( For Admin ) 12 WAY E-TPN DB WITH PPI KIT , IP 43,Incomer : ,63 A TPN MCB,Outgoing :,? 3 Nos, 63A DP MCB+ELCBone in each Phase 30mA,18 Nos, 20 A SP MCB Six in each phase,The above complete with interconnections, etc.
169Power Distribution Board - Three Phase( Miscellaneous Raw PowerTPDB- #) ( For warehouse ),Incomer : ,FLEXY MCB DB 14 MODULE X 4 ROWS, ? 125 A TPNMCCB With O/L, S/C & External Earth Fault Protection,Outgoing :,? 12 Nos. 32 A3P MCB30mA,The above complete with interconnections, etc.
170ISOLATOR SWITCH FOR UPS & INVERTER MCB Distribution Boards- For UPS & Inverter I/P & O/P Isolation Supply, installation of Legrandmake ,SINGLE PHASE10 KA,10A 2P ELMCB 30mA with rotary handle in enclosure & padlocking arrangement made up of 1.2mm thick CRCA sheet, pretreated in seven tank process, powder coated with paint thickness not less than 100 micron ( Shade RAL 7032 ). Cable end box shall be provided for incoming and outgoing cables, complete as per instruction of Engineer In Charge.. ( For Inverter ) Make- LEGRAND / SIEMENS / SCHNEIDER / L&T only
171MCB Distribution Boards- For UPS & Inverter I/P & O/P Isolation Supply, installation of Legrandmake ,THREE PHASE10 KA,16A 4P ELMCB 30mA with rotary handle in enclosure & padlocking arrangement made up of 1.2mm thick CRCA sheet, pretreated in seven tank process, powder coated with paint thickness not less than 100 micron ( Shade RAL 7032 ). Cable end box shall be provided for incoming and outgoing cables, complete as per instruction of Engineer In Charge.. ( For UPS ) Make- LEGRAND / SIEMENS / SCHNEIDER / L&T only
172MCB Distribution Boards- For UPS & Inverter I/P & O/P Isolation Supply, installation of Legrandmake ,THREE PHASE 10 KA,25A 4P ELMCB 30mA with rotary handle in enclosure & padlocking arrangement made up of 1.2mm thick CRCA sheet, pretreated in seven tank process, powder coated with paint thickness not less than 100 micron ( Shade RAL 7032 ). Cable end box shall be provided for incoming and outgoing cables, complete as per instruction of Engineer In Charge.. ( For UPS ) Make- LEGRAND / SIEMENS / SCHNEIDER / L&T only
173MOTORS Testing & commissioning of 415V three phase AC TEFC squirrel cage induction motor. Contractor"s scope under this item shall include noting Name-plate detail, checking IR value and winding resistance of the motor, drying wherever required, recording the same in history sheet, connecting and commissioning the motorif found healthy,changing direction of motor if required. No load testing of motor for minimum of 2 hours. This shall include checking of backup fuse, measurement of voltage, starting current, no load current, Over load setting, testing & commissioning. For motors rated upto & including 5 KW DOL 5 KW to 10 KW - DOL,Testing & commissioning of 415V three phase AC TEFC squirrel cage induction motor
17411 KW to 25 KW - DOL,Testing & commissioning of 415V three phase AC TEFC squirrel cage induction motor
17525KW to100 KW - DOL,Testing & commissioning of 415V three phase AC TEFC squirrel cage induction motor
176CABLE SYSTEM : SUPPLY, INSTALLATION, TESTING & COMMISIONING OF HT CABLE (Supply As per IS 7098 & Installation IS 1255) Supply, Installation, Laying, Testing & commissioning of following size of 11 KV grade of H.T.,XLPE, 3 Core Aluminium conductor ROUND / FLATarmoured Earthed cable underground /through the ready Cable trench including all accessories,labour etc.complete.Excavation,bricks & sand excluded. Make:- POLYCAB / RR KABELS / KEI Only. 11 KV grade of H.T.,XLPE,Alu cable Cable - 3C X 150sqmm
177Earthed Cable - 3C X 185sqmm
178Earthed Cable - 3C X 240sqmm
179Cable - 3C X 300sqmm ( For four pole structure to CSS )
180"LT POWER, CONTROL & SIGNAL CABLES: SUPPLY, INSTALLATION, TESTING & COMMISIONING OF LT CABLE (Supply As per IS 7098 & Installation IS 1255) Supply, Laying, Testing & Commissioningof cables oncable trays, through pendants, on structural supports or clamping on wall / ceiling, include unloading,shifting upto site.The scope includes clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out of M.S. strip 3 mm thick, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium strip and 75x20 mm in size with cable number and size punched on it. Cable tags shall be tied to cables at every 20 meter interval and at both the ends.Empty cable drums shall be returned to stores. In case of laying unlistedcables, rate of cable whose outer dia is closest to the cablesizes quoted shall be applicable. The same shall hold good for cable termination also. Make:- POLYCAB / RR KABELS / KEI Only. 1.1 KV, PVC / XLPE FRLS insulated copper/aluminium conductor armouredcables of following sizes:" 1C x 4 Sqmm YY
1811C x 10 Sqmm YY
1821C x 16 Sqmm YY
18319C x 1.5Sq. mm CU XLPE
18419C x 2.5Sq. mm CU XLPE
18524C x 2.5Sq. mm CU XLPE ( For control )
1864C x 1.5Sq. mm CU XLPE ( For control )
1873C x 2.5 Sq. mm CU XLPE ( For warehouse light fixtures )
1883C X 1.5 Sq.mm CU XLPE
1894C x 2.5 Sq. mm CU XLPE
1903C x 4Sq. mm CU XLPE ( For warehouse single phase power point )
1914C x 4Sq. mm CU XLPE ( For warehouse three phase power point & Street lighting )
1923C x 6Sq. mm CU XLPE( For Inverter to ELDB )
1934C x 6Sq. mm CU XLPE
1943C x 10 Sq. mm CU XLPE
1954C x 10 Sq. mm CU XLPE ( For LDB & USPDB )
1963C x 16 Sq. mm CU XLPE
1974C x 16 Sq. mm CU XLPE
1984C x 16 Sq. mm AL XLPE
1994C x 25 Sq. mm AL XLPE
2003.5C x 25 Sq. mm AL XLPE ( For SPDB & Street Light DB )
2013.5C x 35 Sq. mm AL XLPE
2023.5C x 50 Sq. mm AL XLPE ( For Fire Fighting )
2033.5C x 70 Sq. mm AL XLPE ( For TPDB )
2043.5C x 95 Sq. mmAL XLPE
2053.5C x 120 Sq. mmAL XLPE ( For Mobile Racking )
2063.5C x 150 Sq. mm AL XLPE
2073.5C x 185 Sq. mm AL XLPE ( For APFC Panel & Ambiator unit )
2083.5C x 240 Sq. mm AL XLPE ( For CSS to PCC & DG to PCC )
2093.5C x 300 Sq. mm AL XLPE
210SUPPLY, INSTALLATION, TESTING & COMMISIONING OF LT CABLE (Supply As per IS 7098 & Installation IS 1255) Supply, Installation, Testing, Commisioning, Laying of FLEXIBLE CABLESoncable trays, through pendants, on structural supports or clamping on wall / ceiling, include unloading,shifting upto site.The scope includes clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out of M.S. strip 3 mm thick, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium strip and 75x20 mm in size with cable number and size punched on it. Cable tags shall be tied to cables at every 20 meter interval and at both the ends.Empty cable drums shall be returned to stores. In case of laying unlistedcables, rate of cable whose outer dia is closest to the cablesizes quoted shall be applicable. The same shall hold good for cable termination also. Make:- POLYCAB / RR KABELS / KEI Only. 1.1 KV, PVC insulated copper conductor un -armoured multisrandedFRLS Flexible Cable of following sizes: 4C x 6 Sq. mm YY
2113C x 6 Sq. mm YY
2124C x 4 Sq. mm YY
2133C x 4 Sq. mm YY
2144C x 2.5 Sq. mm YY
2153C x 2.5 Sq. mm YY ( For warehouse JB to Light Fixtures )
2164C x 1.5 Sq. mm YY
2173C x 1.5 Sq. mm YY
2181C x 16 Sqmm YY
2191C x 2.5 Sqmm Copper Wire
220CABLE TERMINATION. SUPPLY & INSTALLATION OF HT CABLE TERMINATION Cable end termination of following PVC/XLPE insulated copper/aluminium conductor armoured cables including supply of all materials, drilling of gland plates and dressing of cables inside panel. HT Cable termination. Makes- RAYCHEM/3M- Supply & Installation of indoor & outdoor type termination kit & HT cable joining for 11 KV, 3Cx 300 Sq. mm XLPE cable. Indoor type. ( CSS )
221Outdoor type. ( Four Pole Structure )
222"SUPPLY & INSTALLATION OF LT CABLE TERMINATION SUPPLY, INSTALLATION, TESTING & COMMISIONING OFINDOOR TERMINATION WITH DOUBBLECOMPRESSION TYPE BRASS-NICKEL MATERIAL, LUGS & PVC HOOD. Makes-a) Cable Gland:- Make - COMMET, BRACO only b) Lugs:- Make- DOWELLS OR BRACO only. " 1C x 4 Sqmm YY
2231C x 10 Sqmm YY
2241C x 16 Sqmm YY
22519C x 1.5Sq. mm CU XLPE
22619C x 2.5Sq. mm CU XLPE
22724C x 2.5Sq. mm CU XLPE ( For control )
2284C x 1.5Sq. mm CU XLPE ( For control )
2293C x 2.5 Sq. mm CU XLPE ( For warehouse light fixtures )
2303C X 1.5 Sq.mm CU XLPE
2314C x 2.5 Sq. mm CU XLPE
2323C x 4Sq. mm CU XLPE ( For warehouse single phase power point )
2334C x 4Sq. mm CU XLPE ( For warehouse three phase power point & Street lighting )
2343C x 6Sq. mm CU XLPE( For Inverter to ELDB )
2354C x 6Sq. mm CU XLPE
2363C x 10 Sq. mm CU XLPE
2374C x 10 Sq. mm CU XLPE ( For LDB & USPDB )
2383C x 16 Sq. mm CU XLPE
2394C x 16 Sq. mm CU XLPE
2404C x 16 Sq. mm AL XLPE
2414C x 25 Sq. mm AL XLPE
2423.5C x 25 Sq. mm AL XLPE ( For SPDB & Street Light DB )
2433.5C x 35 Sq. mm AL XLPE
2443.5C x 50 Sq. mm AL XLPE ( For Fire Fighting )
2453.5C x 70 Sq. mm AL XLPE ( For TPDB )
2463.5C x 95 Sq. mmAL XLPE
2473.5C x 120 Sq. mmAL XLPE ( For Mobile Racking )
2483.5C x 150 Sq. mm AL XLPE
2493.5C x 185 Sq. mm AL XLPE ( For APFC Panel & Ambiator unit )
2503.5C x 240 Sq. mm AL XLPE ( For CSS to PCC & DG to PCC )
2513.5C x 300 Sq. mm AL XLPE
252"SUPPLY & INSTALLATION OF LT CABLE TERMINATION SUPPLY, INSTALLATION, TESTING & COMMISIONING OFINDOOR TERMINATION WITH DOUBBLECOMPRESSION TYPE BRASS-NICKEL MATERIAL, LUGS & PVC HOOD. Makes-a) Cable Gland:- Make - COMMET, BRACO only b) Lugs:- Make- DOWELLS OR BRACO only. " 4C x 6 Sq. mm YY
2533C x 6 Sq. mm YY
2544C x 4 Sq. mm YY
2553C x 4 Sq. mm YY
2564C x 2.5 Sq. mm YY
2573C x 2.5 Sq. mm YY ( For warehouse JB to Light Fixtures )
2584C x 1.5 Sq. mm YY
2593C x 1.5 Sq. mm YY
2601C x 16 Sqmm YY
261The scope shall be including of Light Fittings internal wiring assembly its connection & termination of all outgoing wires at Light Fitting & etc end. Inclosing supply & providing of PVC ferrules / tagging to wires.providing of Power Supply Path Idendification, Numbering with Glow Sign Stickers at Light Fittings. Supply & Installation of Integral, SMD 2x2 LED, IP65, 42W LED Recess mounted Bottom Opening Clean Room fixture with System efficacy of more than 100 lm/W. Luminaire shall be made up of CRCA Housing with CRCA Powder Coated Screwless Bottom Frame. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). Supply, Installation, Testing & Commissioning Of Light Fitting,COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be CRCA constructed, Isolated type, multistage Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
262Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply & Installation of Integral SMD2x2 30W LED Luminaire suitable for recessed grid/POP ceiling with System efficacy of more than 95 lm/W. LED luminaire shall be made up of White Powder Coated Housing & frame in CRCA Sheet. The luminaire shall have high optically efficient HET (PMMA) diffuser. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Everlite Taiwan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. LED luminaire shall use multiple LEDs to ensure proper heat dissipation from LEDs. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs. The LEDs used in the 2’X2’ Luminaire should be ANSI standard Rated LED with CCT of 5700K and CRI of Minimum 80. LED luminaire should be suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C. ( For Admin ) Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
263Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply & Installation of Integral SMD2x2 30W LED Luminaire suitable for Surface Mounted with System efficacy of more than 95 lm/W. LED luminaire shall be made up of White Powder Coated Housing & frame in CRCA Sheet. The luminaire shall have high optically efficient HET (PMMA) diffuser. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Everlite Taiwan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. LED luminaire shall use multiple LEDs to ensure proper heat dissipation from LEDs. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs. The LEDs used in the 2’X2’ Luminaire should be ANSI standard Rated LED with CCT of 5700K and CRI of Minimum 80. LED luminaire should be suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 2 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C. Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
264Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply & Installation of 18W +/- 10% surface mounted IP40 LED Circular Down lighter luminaire with system lumen output =1800 lm. Luminaire shall be made up of die cast aluminium housing with 145 mm dia of cutout. Luminaire shall have Optical Grade High Efficiency Translucent Optical compartment for very high efficiency. Luminaire should Hvae IP rating of IP40 with IK 05 as protection.Optical compartment shall have Unique HET diffuser for wider and uniform distribution. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Ever light should be provided.Luminaire shall use multiple LEDs of less than 1W Class for better diffusion and heat management. The LEDs shall be driven at maximum 600mA for higher reliability. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs. (Complete LM 80 test report for LED should be submitted). The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 5700K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for Photo Biological Safety of humans and Report of the same from LED Manufacturer shall be submitted. Isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 90V to 265V (nominal rated voltage – 240V) with minimum 2KV surge protection, Power factor = 0.95 and total harmonic distortion (THD) of = 10% should be integral to the luminaire. Driver shall be made in India for better service and availability. Driver output voltage shall be less than SELV limits for safe DC operation and maintenance. LM79 Test Report from Third Party NABL Lab to be submitted in the event of order to confirm above parameters. Light Fixtures should be suitable for 0 to 45 Deg. C. Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
265Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply& Installation of 18W +/- 10% recessed mounted IP40 LED Circular Down lighter luminaire with system lumen output =1800 lm. Luminaire shall be made up of die cast aluminium housing with 145 mm dia of cutout. Luminaire shall have Optical Grade High Efficiency Translucent Optical compartment for very high efficiency. Luminaire should Hvae IP rating of IP40 with IK 05 as protection.Optical compartment shall have Unique HET diffuser for wider and uniform distribution. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Ever light should be provided.Luminaire shall use multiple LEDs of less than 1W Class for better diffusion and heat management. The LEDs shall be driven at maximum 600mA for higher reliability. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs. (Complete LM 80 test report for LED should be submitted). The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 5700K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for Photo Biological Safety of humans and Report of the same from LED Manufacturer shall be submitted. Isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 90V to 265V (nominal rated voltage – 240V) with minimum 2KV surge protection, Power factor = 0.95 and total harmonic distortion (THD) of = 10% should be integral to the luminaire. Driver shall be made in India for better service and availability. Driver output voltage shall be less than SELV limits for safe DC operation and maintenance. LM79 Test Report from Third Party NABL Lab to be submitted in the event of order to confirm above parameters. Light Fixtures should be suitable for 0 to 45 Deg. C.( For Admin ) Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
266Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply & Installation of Integral, SMD LED, IP65, 40W Surface / Pendant mounted totally enclosed LED luminaire with System efficacy of more than 100 lm/W. LED luminaire shall be made up of Sturdy vandal resistant light grey polycarbonate body with polyurethane gasket. The luminaire shall have LED grade UV stabilized polycarbonate diffuser. The luminaire shall have Sturdy polycarbonate clips for fixing diffuser to housing. The luminaire shall have Waterproof cable gland ensuring good ingress protection. LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Everlite Taiwan / Osram Germany should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum five years. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be CRCA constructed, Isolated type, multistage Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3.5 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 20% should be integral to the luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 ( For LT Panel room & External Canopy ) Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
267Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply & Installation of Integral, SMD LED, IP65, 80W LED Surface/Suspend Mounted Round Mid-Bay / High-Bay fixture with System efficacy of more than 130 lm/W. Luminaire shall be made up of Die Cast Aluminium Housing. Luminaire shall have Polycarbonate high transmitivity diffuser for Uniform illumination and wider light distribution. The innovetive design with Aeroflo Technology ensures flow of free air through the Housing and keep the heat away from Electrical Components . LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 100000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be CRCA constructed, Isolated type, multistage Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 4 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
268Supply, Installation, Testing & Commissioning Of Light Fitting COMMERCIAL AND INDUSTRIAL LIGHT FIXTURE Supply & Installation of Integral, SMD LED, IP65, 100W LED Surface/Suspend Mounted Round Mid-Bay / High-Bay fixture with System efficacy of more than 130 lm/W. Luminaire shall be made up of Die Cast Aluminium Housing. Luminaire shall have Polycarbonate high transmitivity diffuser for Uniform illumination and wider light distribution. The innovetive design with Aeroflo Technology ensures flow of free air through the Housing and keep the heat away from Electrical Components . LM 80-08 compliant LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 100000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be CRCA constructed, Isolated type, multistage Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 4 KV internal surge protection, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Make - WIPRO / PHILLIPS / BAJAJ / CROMPTON
269UPS & INVERTER SYSTEM Supply & Installation of 5 KVA Inverter, 3Phase input & 3 Phase output with 30.0 Minutes Battery back up time SMF batteries with overload, short circuit protection. Make:- MICROTECH / CONSULE NEOWATT / SWASTIK
270UPS & INVERTER SYSTEM Supply & Installation of 2 KVA Inverter, 3Phase input & 3 Phase output with 30.0 Minutes Battery back up time SMF batteries with overload, short circuit protection. ( For Warehouse & Admin Emergency Light ) Make:- MICROTECH / CONSULE NEOWATT / SWASTIK
271UPS :-Make:- SCHNEIDER ( APC )/ CONSULE NEOWATT / VERTIV / EATON / SOCOMEC Supply & Installation of 10 KVA UPS, 3Phase input & 3 Phase output with 15.0 Minutes Battery back up time SMF batteries with overload, short circuit protection. ( For Warehouse & Admin UPS Power )
272Supply & Installation of 5.0 KVA UPS, 3Phase input & 3 Phase output with 15.0 Minutes Battery back up time SMF batteries with overload, short circuit protection. ( For server )
273INDUSTRIAL SWITCH BOXES & PLUG SOCKET OUTLET Supply, Installation, testing and commissioning of industrial surface mounting, powder coatedmetal clad socket and control MCB/ MCCB combination enclosed inenclosure made out of 1.2 mm thick sheet steel enclosure, pretreated and painted with two coats of primer and two coats of epoxy paint. MCB and socket shall be wired up upto outgoing terminals. Make - a) Encloser :- LEGRAND / VEEDHI INTERNATIONAL / PUSTRON b) Switch-Gears:- Make-LEGRAND / SIEMENS / SCHNEIDER / L&T only "32A , Three Phase, 5 pin Industrial type socket ( IP 44 ) with 32A TP+N MCB & 5 pin plug top, 10KAenclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated .( For Warehouse three phase Miss. Raw Power, dock leveler & rolling shutter )
274"25A, single Phase, 3 pin Industrial type socket ( IP 44 ) with 25A SP MCB & 3 pin plug top, 10KA enclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated .( For Warehouse single phase Miss. Raw Power & Battery charging )
27520A, single Phase, 3pin Industrial Metal Clad type socket( IP 44 ) 10KA enclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated along with Industrial Metal Clad Type 20A Plug Top.
2761No- 16A SinglePhase, SP MCB Industrial type( IP 44 ), 10KAenclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated. ( For Warehouse Lighting )
2772No- 16A SinglePhase, SP MCB Industrial type( IP 44 ), 10KA enclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated. ( For Lighting )
2783No- 16A SinglePhase, SP MCB Industrial type( IP 44 ), 10KAenclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated.
279LOCAL CONTROL STATION(START AND STOP PUSH BUTTON) enclosed in 1.2mm thick,CRCA sheet steel box with MS Cover powder coated front plate. ( For Equip. Raw Power )
280Supply,installation of Hensel IP65 Polycarbonate Junction Box, Waterproof, Weatherproof, Flameproofjunction boxes with shrouded 16 amp. Terminals- 4Nos, Knock outs for cable entries- 4 Nos. (With 2 Earthing Studs) Sizes as below: Make:-PUSTRON / HANSEL Only. 100x100x50 mm with four terminals. ( For Warehouse, canopy & panel room lighting )
281Supply,installation, Testing & Commissioning of Push Button Station Make:-LEGRAND / SIEMENS / SCHNEIDER / L&T Only. Push button station with start and lockable stop in aluminium diecast enclosure IP 55 protection suitable for outdoor installation.(2 Cable entries with plugs & 2 Earthing studs.)
282POINT WIRING Supply, Installation & Laying copper multistrand conductor 660/1100Vgrade PVC FRLS insulated wire The scope shall be including of its connection & termination of all incoming & outgoings wires at both end. Inclusing supply & providing of PVC ferrules / tagging to wires. Make - POLYCAB / RR KABELES / KEI / FINOLEX 1100 volt grade 2 nos. single core 2.5 sq.mm. + 1 No. 1.5 sq.mm
2831100 volt grade 2 nos. single core 4 sq.mm. + 1 No. 2.5sq.mm
2841100 volt grade 4 nos. single core 4 sq.mm. + 2 Nos. 2.5sq.mm
2851100 volt grade 4 nos. single core 6 sq.mm. + 2 Nos. 4 sq.mm
286MODULAR TYPE SWITCH SOCKET Supply, installation of Modular switches, socket outlets, mounting of associated junction box concealed in wall and press fit flush type PVC/ SS front plate. Make - LEGRAND / MK / NORTH-WEST / ANCHOR ROMA 1 No.16 A, 230 V single pole modular type switch with GImetal box with press fit flush type PVC front plate complete with all accessories.
2871 No.20 A, 230 V single pole modular type switch with GImetal box with press fit flush type PVC front plate complete with all accessories for AC.
2882 No. 16 A, 230 V single pole modular type switch with GImetal box with press fit flush type PVC front plate complete with all accessories.
2893 No.16 A, 230 V single pole modular type switch with GImetal box with press fit flush type PVC front plate complete with all accessories
2904 No. 16 A, 230 V single pole modular type switch with GImetal box with press fit flush type PVC front plate complete with all accessories.
291Power Socket :1 no. 6 / 16 Amps modular type 5 pin Socket with switch in common GImetal box with press fit flush type PVC front plate
292Power Socket :2 no. 6 / 16 Amps modular type 5 pin Socket with switch in common GImetal box with press fit flush type PVC front plate
293Power Socket :1 no. 25 Amps modular type 5 pin Socketin common GImetal box with press fit flush type PVC front plate for AC.
2941 No. Bell push with GImetal box with press fit flush type PVC front plate complete with all accessories.
295Telephone and Computer Outlets: Make:- LEGRAND, AMP, SYSTIMAX only. Supply and installation of TV Socket connector with box &PVC front plate. ( For Admin )
296SUPPLY & INSTALLATION OF PVC CONDUIT OF FOLLOWING Make:- PRECISION, POLYCAB, CIRCLARC, PUSTRON only Supply& Installation of PVC conduit, conduit accessories likepull wire, end check nuts, washers, couplings, smooth bends, junctionboxes etc.for concealed wiring or exposed wiring. 25 mm PVC conduit
29732 mm PVC conduit
298SUPPLY & INSTALLATION OFFLEXIBLE PVC CONDUIT OF FOLLOWING Make:- PRECISION, POLYCAB, CIRCLARC, PUSTRON only 25 mm Flexible PVC conduit
29932 mm Flexible PVC conduit
300Supply & Installation of MS CONDUIT of following Supply& Installation of MS conduit, conduit accessories likepull wire, end check nuts, washers, couplings, smooth bends, junctionboxes etc.for concealed wiring or exposed wiring. Make:- VIMCO, BEC, PUSTRON only. 25 mm MS PVC conduit
30132 mm MS PVC conduit
302Supply & Installation of GI CONDUIT of following Make:- VIMCO, BEC, PUSTRON only. Supply& Installation of GI conduit, conduit accessories likepull wire, end check nuts, washers, couplings, smooth bends, junctionboxes etc.for concealed wiring or exposed wiring. 25 mm GI PVC conduit
30332 mm GI PVC conduit
304Supply & Installation, Testing & Commissioning Of External Light Fitting on Poles Make - WIPRO/ PHILLIPS / BAJAJ / CROMPTON Supply & Installation of 45W +/- 5% LED Street Light luminaire with System efficacy of more than 100 lm/W and with System Lumen Output 4500 Lumen. LED Street Light shall be made up of pure polyester powder coated Pressure Die Cast aluminium housing suitable to be mounted on external pole dia up to 40-60 mm. Luminaire shall have two separate compartments for LEDs and driver and both compartments should be hermitically sealed to achieve IP 66 ingress protection. Optical compartment shall be provided with heat resistant clear Polycarbonate LENS to withstand IK 07 impact rating. The luminaire shall have potted type driver. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Osram Germany / Citizen Japan / Bridgelux USA should be provided. LED optical lens should be properly fixed to MCPCB and should not be only fixed by glue. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current and at 100 Deg C Ambient temperature (Complete LM 80 test report for LED should be submitted for 9000 hrs of testing). EXTERNAL / STREET LIGHT FITTINGS ANDPOLES External Light FittingMounted On Street Light Pole The LEDs used in Street Light should be ANSI standard Rated LED with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted Isolated type, multistage Constant Current topology driver suitable to operate in input voltage range of 120V to 300V (nominal rated voltage – 240V) with 4 KV internal surge protection in both CM and DM mode, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Driver shall have Low Voltage Cutoff and High Voltage Cutoff . Driver shall withstand 440V for 8 Hrs. The Driver output shall be SELV type (< 60V DC) to ensure safe operating and maintenance operation. LED driver shall have output short circuit & over voltage protection inbuilt. Driver shall be BIS Registered and preferably shall be of same make of luminaire. Light Fixtures should be suitable for 0 to 45 Deg. C.
305Supply & Installation of 90W +/- 5% Top Maintainable LED Street Light luminaire with System efficacy of more than 110 lm/W and with System Lumen Output 9900 Lumen. LED Street Light shall be made up of pure polyester powder coated Pressure Die Cast aluminium housing suitable to be mounted on external pole dia up to 55 mm. Luminaire shall have two separate compartments for LEDs and driver and both compartments should be hermitically sealed to achieve IP 66 ingress protection. Optical compartment shall be provided with heat resistant clear toughened glass to withstand IK 07 impact rating. The luminaire shall have potted type driver. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Osram Germany / Citizen Japan / Bridgelux USA should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current and at 100 Deg C Ambient temperature (Complete LM 80 test report for LED should be submitted for 9000 hrs of testing). The LEDs used in Street Light should be ANSI standard Rated LED with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be Isolated type, multistage Constant Current Constant Voltage topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 120V to 300V (nominal rated voltage – 240V) with 4 KV internal surge protection in both CM and DM mode, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Driver shall have Low Voltage Cutoff and High Voltage CutoffDriver shall withstand 440v for 8 Hrs. . LED driver shall have output short circuit & over voltage protection inbuilt. Light Fixtures should be suitable for 0 to 45 Deg. C. Wipro Model No. LR02-102-XXX-57-G2
306Supply & Installation of 45 W LED Post Top luminaire with System efficacy of more than 90 lm/W. LED Post Top Light shall be made up of Die Cast aluminum housing for better heat dissipation. Luminaire shall have compartments for LEDs and driver and both compartments should be hermitically sealed to achieve IP 65 ingress protection. Optical compartment of LED Post Top shall be made up of clear acrylic reflector to reduce glare and to provide uniform light distribution. LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Citizen Japan should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. LED should be fixed to MCPCBonly. The LEDs shall be driven at minimum 500mA to 800mA. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs (Complete LM 80 test report for LED should be submitted) at ambient temperature of more than 85 Deg C. The LEDs used in Post Top should be ANSI standard Rated LED with CCT of 5700 K and CRI of Minimum 70. Isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with minimum 3KV surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. The driver should be fully designed and manufactured in India. Light Fixtures should be suitable for 0 to 45 Deg. C.
307Supply of 10W, IP65 Bollard LED Fixture with pressure die cast aluminium housing with pipe, powder coated dark grey and polycarbonate diffuser. The luminaire shall be suitable for illuminating pathways, parking lots in the area like hotels, resorts, housing complexes. Luminaire shall have a CCT of 5000K. LED Driver should be CC, isolated and multistage for better protection. Luminaire Manufacturer shall provide LM79, LM80 Reports.
308Street Lighting Pole With Civil Work Including Foundation etc… as per attached Drawing Supply,Installation, Testing & Commissioning Of Street Light Poles Supply, installation of street light pole of following specification with all civil workinclusive foundation, etc. and painting (2 coats of red oxide and 2 coats of Aluminium paint).The rate shall also include cost of 2 nos. 1.5 mtr. Longrod electodes for earthing of EACH pole Make:-INDIA POLES, BOBAY POLES, UTKARSH INDIAIS Code : 410 - SP 7.5 Mtr. Height Street Light Pole CURVED AT TOP with 2 nos. 1.5 mtr. Earth pipe Electrode (above ground) as per IS code IS WP 2
3097.5 Mtr. Height Street Light Pole with double CURVED AT TOP with 2 nos. 1.5 mtr. Earth pipe Electrode (above ground) as per IS code IS WP 14
310Supply, Installation, Testing & Commissioning of 3.0 Meter wall mounted light poles suitable to fixing of 45W LED Street Light Fixture Make:-INDIA POLES, BOBAY POLES, UTKARSH INDIA Supply & fixing of 3.0 Meter wall mounted light poles suitable for above 45W LED Street Light Fitting complete with accessories. The Pole shall be swagged poles, 50 dia base. Rate includes all required accessories for fixing on wall with necessrry Earthing. The Pole shall have Weather Proof junction Box IP 65 3 way with 06A DP MCB provision in the Pole & 08 Nos of 16 A Elmex Connector Terminals for Loop in loop out.
311Junction Box Make:- a) Encloser:- SINTEX Make only b) Switchgears:- LEGRAND / SIEMENS / SCHNEIDER / L&T Supply, Installation, testing & commissioning of Marshalling box. The Box shall be mounted at 600mm from G.L. Marshalling box shall be a weather proof enclosure made up of Al. diecast junction box with powder coated finish & shall contain one 10A DP MCB & 8 Nos, 32A Elmex connector for R, Y, B & N phases. 2Nos M10 earthing stud shall be provided from both side of JB
312GI CABLE TRAY Supply,Installation of prefabricated hot deep galvanized (IS 2629:1989)Coverage as per IS 4759:1984. Min. 610 gms./Sq. Mtr. for trays minimum thickness of zinc deposits on all points shall be 75 microns.), ladder/ perforated type cable trays of minimum 2.5 mm thick. Prefabricated, bends and couplers with G.I. Nuts and bolts. Gas cutting of cable trays at site is not permitted. If any welding (As per IS 816:1969) is to be done on cable trays, the welded part shall be touched up with anti-corrosive primer and silver paint. The running rate shall include bends and couplers. Cable tray supports shall be paid extra. Coupler plates shall be made out of 3 mm thick steel sheet, shall be hot dip galvanised conforming to IS 4759:1984, IS 2629:1985 and IS 2633:1986. Coupler plates shall have 8 Hole; 4 holes and 4 slots) Hardware: M8 x 25 long GI bolt, Nut with 2 plain washers and 1 spring washer - Suitable for coupler plates. Make:- INDIANA OR BILMET OR GLOBE OR PROFAB 50 x 50 mmwide cable tray perforated type
313100 x 50 mmwide cable tray perforated type
314150 x 50mmwide cable tray perforated type
315300 x 50mmwide cable tray perforated type
316300 x 100mm wide cable tray ladder type
317450 x 100 mm wide cable tray perforated type
318750 x 100mm wide cable tray ladder type
319GI CABLE TRAY COVER Supply, Installation of cable tray covers fabricated out of 2mm thick Aluminium sheet along with fixing arrangement. The cable tray cover shall be removable type, with powder coating. Make:- INDIANA / BILMET / GLOBE / PROFAB GI CABLE TRAY Cover for 50mm
320GI Cable Tray Cover for 100mm
321GI Cable Tray Cover for 150mm
322GI Cable Tray Cover for 300mm
323GI Cable Tray Cover for 450mm
324GI Cable Tray Cover for 600mm
325Structural steel work ( Confirming to IS 4923-1997) riveted, bolted or welded in builtup for all type sections, in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per the structural designs and directions of Engineer in charge ( For Light fixtures, Cable tray, DBs, LT panels & etc.. supports ) Make- JINDAL, JSW, TATA, SAIL only
326Supply &Installation of Anchor Fastner of following sizes Make- HILTI, FISCHERS Only Anchor Fastner - 8mm Dia
327Anchor Fastner - 10mm Dia
328Anchor Fastner - 12mm Dia
329Supply &Installation of Threaded rod of following sizes , Threaded rod - 8mm, 10mm, 12mm with all its accessories Threaded rod - 8mm Dia
330Threaded rod - 10mm Dia
331Threaded rod - 12mm Dia
332Supply and Installation of Hume pipes NP2 Class for raod crossing 100mm dia. RCC Hume pipes
333150mm dia. RCC Hume pipes
334300mm dia. RCC Hume pipes
335Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(E) 40mm
336Providing and fixing to wall, ceiling and floor galvanised Mild steel tubes (Medium grade) of the following nominal bore, tube fitting and clamps including making good the wall ceiling and floor.(C) 25mm
337Providing , Chiseling in wall/ RCC and plaster of chasing work as directed by Client /PMC team Chiseling of brick wall.(75mm wide x 75mm deep)
338Chiseling of RCC wall.(50mm wide x 50mm deep)
339Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
340Dense or Hard soil
341Supply & Laying of following of Bricks/ Tiles with LT markings ( for CSS to LT Panel room & street lighting cable )
342Supply & Laying of following of River sand (per cu. Meter) ( for CSS to LT Panel room & street lighting cable )
343Air Curtain Supply, Installation, Testing and Commissioning of following air curtains Make- EURONICS, TECHNOCRAT, ALMONARD Only 230V, 1 PhaseM.S powder coated air curtain with air velocity of 12 to 14m/s Sutiable for Door Width- 800mm
344230V, 1 PhaseM.S powder coated air curtain with air velocity of 12 to 14m/s Sutiable for Door Width- 750mm
345Insect Killer Supply, Installation, Testing and Commissioning of 230V wall/ceiling mounted M.S Insect killer with philips 2x20W tube. Make- PESTO-PLASH, TECHNOCRAT Only
346WALL MOUNTING FAN Make - ALMONARD, CROMPTON , ORIENT Only Supply, Installation, Testing and Commissioning of 18 inch dia Industrial Type Wall Fan
347Supply, Installation, Testing and Commissioning of 24 inch dia Industrial Type Wall Fan
348EXHAUST FAN Make - REMI, CROMPTON Only Supply Installation, Testing and Commissioning of IndustrialType Single Phase 600mm Dia Exaust Fan of Reputed Make
349Supply Installation, Testing and Commissioning of IndustrialType Single Phase 450mm Dia Exaust Fan of Reputed Make
350Supply Installation, Testing and Commissioning of IndustrialType Single Phase 300mm Dia Exaust Fan of Reputed Make
351Supply Installation, Testing and Commissioning of IndustrialType Single Phase 150mm Dia Exaust Fan of Reputed Make ( For Admin WC )
352Manpower Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
353Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
354Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
355Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
356Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
357Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
358Supply of Manpower for Electrical work on daily basis for 8Hrs (Skill & Quantity as per site requierment and at actuals on the basis of Log register)
359EARTHING: Supply Installationof hot dipped galvanized (GI)/copper bare earth conductorbar / flexible wire /strip offollowing sizes. The installation shall include drilling of holes,connection & supply of adequate lugs, clamping, hardware material, Welded joints (As per IS 816:1969) shall be used for G.I. strips. Welded joints after welding shall be painted with anticorrosive black bitumen paint, excavation & refilling of soil for burrying the strip wherever applicable is included in the rate. Make:- AS PER IS STANDARD Only 25 x 3 mmcopper strip
36025 x 6 mmcopper strip
36150 x 6 mmcopper strip ( For CSS, DG & UPS )
36232 x 6 mm G.I. Strip
36325 x 10mmG.I. Strip
36425 x 6mmG.I. strip (For CSS, DG, two pole & Grid)
36525 x 3mmG.I. strip ( On Cable Tray for DB, equipmennts, panels )
3668 SWG GI wire ( For DB, Switch & Sockets )
36712 SWG GI wire ( For DB, Switch & Sockets )
3688 SWG CU wire
3691C x 2.5 Sqmm Copper conductor green earth wire
3701C x 4 Sqmm Copper conductor green earth wire
3711C x 6 Sqmm Copper conductor green earth wire ( For Inverter )
3721C x 10 Sqmm Copper conductor green earth wire ( For UPS )
3731C x 25 Sqmm Copper conductor green earth wire ( For Lightning Protection )
374EARTH PIT(COPPER ELECTRODE ) Preparation and commissioning of Chemical earth pits with 80 mm dia 3.0 mtrs deep Cu Rod electrode and with watering arrangement of chamber & funnel, charcoal salt etc.The electrode shall be connected with 40 mm x 3 mm thick Cu Strip and terminated into the chamber with nut bolt arrangement.The rate shall include cost of the earthing strip upto the chamber. As per attached specification. Make- ASHLOK, INDELEC,ERRICO Only
375EARTH PIT(COPPER ELECTRODE ) Supply and installation of earthing station as per IS 3043 complete with 600x600x6 mm copper earthing electrode plate,salt, charcoal, 2 nos. 50x6 mm copper. Conductor upto test link, 19 mm dia G.I. watering pipe with funel,test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc. Make :-AS Per IS ( For CSS, DG & UPS )
376EARTH PIT(GI ELECTRODE ) Supply and installation of earthing station as per IS 3043 complete with 600x600x6 mm GI earthing electrode plate,salt, charcoal, 2 nos. 25x6 mm GI. Conductor upto test link, 19 mm dia G.I. watering pipe with funel,test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc. ( For CSS, DG, two pole & Grid )
377EARTH PIT(GI ELECTRODE ) Supply Installation of Boring Earthing for Earth Pit Masonary Work / Earth pit Coverand Connecting Links for Boring Earth Electrodes of 150 Dia and entire Boring Activity including installation of 150 mm Dia G I Pipe Electrode As Complete as Required.
378EARTH PIT(GI ELECTRODE ) Preparation and commissioning of Chemical earth pits with 80 mm dia 3.0 mtrs deep GI Rod electrode and with watering arrangement of chamber & funnel, charcoal salt etc.The electrode shall be connected with 40 mm x 3 mm thick GI Strip and terminated into the chamber with nut bolt arrangement.The rate shall include cost of the earthing strip upto the chamber. As per attached specification.Make- ASHLOK, INDELEC,ERRICO Only
379LIGHTNING ARRESTER : Supply, Installation, Testing & Commissioning of M/s Indelec Lightning Arrester system make with all kind of hard wears as per IS approved code. It include supervision of M/s Indelec Lightning Arrester system supervisor. Model S 4.5 Make- Indelec
380Supply, Installation, Testing & Commissioning of Lightining Flash Counter as instracted by Client /PMC
381SUPLY & INSTALLATION OF SAFETY ITEMS Make:- AS PER IS STANDARD Only Sand buckets with stand. (set of 3 buckets) AS PER IS 2546 : 1974 ( For HT Yard )
382Caution boards (11KV) of std. Size. AS PER IS 2151 ( For HT Yard )
383Caution boards (433V) of std. Size.AS PER IS 2151 ( For Panel Room )
384Insulating Mat at panel room 11KV Grade,1mtr. Wide As Per IS 15652 : 2006 Make - VIDUT, ELECTROMAT
385Insulating Mat at panel room 415V Grade, 1mtr. Wide As Per IS 15652 : 2006 Make - VIDUT, ELECTROMAT ( For Panel Room )
386Shock treatment chart as per electricity board.
38711 KV rating rubber hand gloves. AS PER IS 4770 : 1991
388500V rating rubber hand gloves.
389First aid box with standard items. AS PER IS 13115.b.1991
39011 KVHT cable route marker.
391500v LT cable route marker. ( For CSS to Panel Room )
392Lock-Out - Tag Out Station with Lock & Tags
39311kV Earth Discharging Rod
394REMOVING, DISMENTLING, SHIFTING, LOADING & UNLOADING OF EXISTING LT PANELS Removing, Dismentling , Shifting, Loading & Unloading of following 415 voltswitchboards / control panels. Including Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge, Switch Board Designation: EXISTING LT PANEL Voltage :415 V.,Construction :Single Front.,Approximate Dimensions:- 2000 ( L ) X 400 ( D ) X 2000 ( H ) in mm.,Approximate Weight:- 750 Kgs
395REMOVING, DISMENTLING, SHIFTING, LOADING & UNLOADING OF EXISTING DISTRIBUTION BOARDS Removing, Re-Installation, testing and commissioning of following 415 voltswitchboards / control panels. Including Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge Distribution Board The above complete with interconnections, etc.
396Removing, of existing cables of following size of 1.1 KV grade of L.T.,XLPE / PVC, FRLS Cu/ AL conductor armoured/unarmoured cable from underground /through the ready Cable trench / cable tray including removing of all accessories,labour etc.complete.removing of Excavation,bricks & sand etc. 1.1 KV, PVC / XLPE FRLS insulated copper/aluminium conductor armouredcables of following sizes: 3C x 2.5 Sq. mm CU XLPE
3973C X 1.5 Sq.mm CU XLPE
3984C x 2.5 Sq. mm CU XLPE
3993C x 4Sq. mm CU XLPE
4004C x 4Sq. mm CU XLPE
4014C x 6Sq. mm CU XLPE
4024C x 10 Sq. mm CU XLPE
4033C x 16 Sq. mm CU XLPE
4044C x 16 Sq. mm CU XLPE
4054C x 16 Sq. mm AL XLPE
4063.5C x 25 Sq. mm AL XLPE
4073.5C x 35 Sq. mm AL XLPE
4083.5C x 50 Sq. mm AL XLPE
4093.5C x 75 Sq. mm AL XLPE
4103.5C x 120 Sq. mm AL XLPE
4113.5C x 185Sq. mm AL XLPE
4123.5C x 240 Sq. mm AL XLPE
413Removing, Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge of following Cable end termination of following PVC/XLPE insulated copper/aluminium conductor armoured cables. INDOOR TERMINATION WITH DOUBBLECOMPRESSION TYPE BRASS-NICKEL MATERIAL, LUGS & PVC HOOD. 3C x 2.5 Sq. mm CU XLPE
4143C X 1.5 Sq.mm CU XLPE
4154C x 2.5 Sq. mm CU XLPE
4163C x 4Sq. mm CU XLPE
4174C x 4Sq. mm CU XLPE
4184C x 6Sq. mm CU XLPE
4194C x 10 Sq. mm CU XLPE
4203C x 16 Sq. mm CU XLPE
4214C x 16 Sq. mm CU XLPE
4224C x 16 Sq. mm AL XLPE
4233.5C x 25 Sq. mm AL XLPE
4243.5C x 35 Sq. mm AL XLPE
4253.5C x 50 Sq. mm AL XLPE
4263.5C x 75 Sq. mm AL XLPE
4273.5C x 120 Sq. mm AL XLPE
4283.5C x 185Sq. mm AL XLPE
4293.5C x 240 Sq. mm AL XLPE
430Removing Of Light Fixtures Removing, Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge of indoor & outdoor type light fittings. Surface mounting high bay 80/100/120/150 W luminaire
43140W Surface mounting CFL type capsule polycarbonate housing polycarbonate diffuser luminaire
43236W Surface/Recess mounting 2’X2’ Luminaire
43345/90W Street Light fixtures with 1.5M pole & its accessories.
434200/300W flood Light fixtures
435Removing Of Cable tray Removing & Reinstallation including Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge of indoor cable tray. 50 x 50 mmwide cable tray perforated type
436100 x 50 mmwide cable tray perforated type
437150 x 50mmwide cable tray perforated type
438300 x 50mmwide cable tray perforated type
439300 x 100mm wide cable tray ladder type
440450 x 100 mm wide cable tray perforated type
441600 x 100mm wide cable tray perforated type
442Removing, Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge of RLS PVC conduit, conduit accessories likepull wire, end check nuts, washers, couplings, smooth bends, junction boxes etc. 25 mm
44332 mm
444Removing, Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge ofModular type switch & sockets board 5/16 A, 230 V, 18 Module modular type switch & socket with PVCbox with PVC front plate complete with all accessories.
4455/16 A, 230 V, 12 Module modular type switch & socket with PVCbox with PVC front plate complete with all accessories.
4465/16 A, 230 V, 8 Module modular type switch & socket with PVCbox with PVC front plate complete with all accessories.
4475/16 A, 230 V, 6 Module modular type switch & socket with PVCbox with PVC front plate complete with all accessories.
4485/16 A, 230 V, 4 Module modular type switch & socket with PVCbox with PVC front plate complete with all accessories.
449Power Socket :1 no. 6 / 16 Amps modular type 5 pin Socket with switch in common GImetal box with press fit flush type PVC front plate
450Power Socket :1 no. 20 Amps modular type 5 pin Socket with 25A SP MCB in common GImetal box with press fit flush type PVC front plate
451Removing, Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge of FAN Removing of existing FAN
452REMOVING OF EARTHING Removing of hot dipped galvanized (GI)/copper bare earth conductorbar / flexible wire /strip offollowing sizes. Including Shifting, Loading, Unloading & Store at suitable place as per direction of engineer incharge 25 x 3 mmcopper strip
45325 x 6 mmcopper strip
45450 x 6 mmcopper strip
45532 x 6 mmcopper strip
45650 x 6mmG.I. Strip
45732 x 6 mm G.I. Strip
45825 x 10mmG.I. Strip
45925 x 6mmG.I. strip
46025 x 3mmG.I. strip
461REMOVING OF EXISTING DG SET Removing of following DG Set. Including Shifting, Loading, Unloading at suitable place as per direction of engineer incharge. Removing of 1 Nos x 50KVA DG set (Included unloading & shifting). This scope Includes accoustic enclosure,Adaptor Box ,fuel tank, AVM Pad, Lube oil pump & etc.
462WMS software Supply, Installation, Testing & Commissioning of following equipments/System of Specifications for warehousing management system (WMS) 1. Operations and functionalities a. Receipt i. ASN upload into the WMS through excel file (1 format) ii. Amend ASN before GRN iii. GRN and confirmation of receipt against inward document iv. Connect the WMS with the weighing system v. Barcode labelling & scanning receipts vi. Ability to manage exceptions vii. Design a put-away plan b. Dispatch i. Orders to be booked in the WMS by customer (order amendment not permitted, only order cancellation to be permitted for a limited period). ii. Order approval to be obtained from OIDC – before the order is taken up for processing. iii. Allocation of stock as per batch, FIFO, FMFO iv. Manage orders in cases and pieces v. Scan and pick material vi. Create outer shipping box vii. Connect the WMS with the weighing systemviii. Confirm dispatch, and return un-dispatched stock to the warehouse c. Cycle count i. Create plans for stock verification and cycle count ii. Reconcile variances across bin-locations d. Bin to bin transfer i. Allow manual bin to bin transfer of inventory e. Stock adjustment i. Batch update ii. Block / unblock inventory f. MIS reports i. Stock report ii. Completed transaction report (inward, outward) iii. Pending transactions report iv. Expired stock report v. Damaged stock report vi. Bin utilization report g. Master data management i. Product master ii. Bin location master iii. Storage capacity master h. Payment processing i. Provide a link to a payment gateway (example: CCAvenue, Billdesk, etc) ii. Accept the payment confirmation / rejection from the payment gateway iii. Administrator shall have an option to reverse a payment (no integration with the payment gateway) iv. Exclusions: 1. User confidential information (such as credit card number, bank account, etc) will not be captured in the WMS. It shall be done on the payment gateway 2. Exceptions shall be managed outside the WMS. This includes disputes, failed payments, reversal of payments, etc 2. Administration a. User management i. User creation ii. Password policy iii. User role management b. User manual (PDF) to be available as a download 3. User interface a. Desktop / laptop with Windows OS i. WMS should support standard browsers – Chrome, Firefox b. Mobile smart phones and barcode scanners with Android OS i. Barcode scanning to be available on standard devices ii. Mobile phone app to be available for non-scanning operations 4. Data backup and recovery a. Daily backup of data i. Data backup to be automated, and at a minimum frequency of once in 24 hours 5. Support a. Support over phone and email during regular working hours i. Support email address to be available ii. Response and issue resolution (SLA) to be framed 6. Hosting a. WMS to be hosted on users’ web server 7. Data interface with external software a. WMS should interface with external software using web services or APIs WMS license (License and software cost for Silvassa w/h- 1 Nos Web server (Web server to host the WMS ) - 3 Nos Hardware Scanners (Barcode scanners with Android OS ) - 20 Nos Printers (Barcode label printers ) - 10 Nos
463Motorized Mobile Palletized Heavy Duty Racking Systems.(GODOWN-A) Supply, Installation , testing & commissing of the whole drive carriage assembly should be of knock - down design. In case of change in layout or design the same Drive carriage assembly should be utilized. The drive carriage Material of Construction should be as par IS:2062. The shaft mount bearing should be flange type with supporting circular collar and fixed with drive carriage and shaft with 4 nos. of heavy fasteners. It should be self-aligned and self-lubricated sealed type. The wheel material of construction should be graded as per IS : 1865 - 1991, IS:1608-2005, IS:1500-2005. The wheel assembly should not be open to avoid any accident happenings. The drive motor gear should be in line within the drive carriage. No projection above the drive carriage is permitted. Nopallet location should be lost or mis-aligned. Forward, reverse, emergency stop arrangements on the control panel. Limit switch, proximities and emergency stop arrangements on the base unit and vertical post. 1st stage electric motor directly connected with well - designed composite gear box. 2nd stage reduction is also carried out with the help of M.S. solid heavily constructed gear set.Any MHE can be used. if the MHE is having straddle Arm that also is possible 110 MM ground clearance is provided. Noise Level will be 80 db with acoustic sound. Movement speed will be 4 mtr/min. Motorized Mobile Palletized Racking System structure is mounted on the mobile trolleys. These trolleys are made very uniquely designed knockdown method.Each & every component can be separated / assembled. The rack load is transferred to wheel assembly and ultimately on Rails and Floor. Each unit is driven by 2 reduction geared motors which is linked to the wheels with solid M.S. 2nd stage reduction gears, gives extra ordinary strength to the power transmission as well as unbelievable smooth movement. Well-designed electric Motors conformance to Indian standards as well as international standards. First stage reduction gear box is mounted with the electric motor. 2nd stage reduction of motion is by way of properly designed CNC hobbling mechanized solid MS Gear. This combination results to carry the design load in comparison low motive power. The motors are placed within the height of the understructure. The motor is covered for preventing from damage and dust penetration, as chemical resistant. Soft start and soft stop feature of VFD provided jerk free operation of racks. In addition, this will improve the location power factor improvement. Shot circuit protection. Earth linkage protection. Over current protection. In case of motor overload or motor locking tripping of the system will take place. Whole systems Operate on 3 phase, 415V AC supply. 24V DC power supply for switching operation in Control panel. Proximity detectors controlled electronically through PLC. Individually indicatingflasher cum buzzer for each unit. Protection for each rack through proximity & limit switch.The Electric Motors are Delphi series in conformance to Indian standards IS : 1231, IS : 2223and International standards IEC 72-1. These Motors are multiple voltage, multi-frequency 50/60 Hz., F class insulation, S1 continuous duty service, IP55 protection, 1 or 2 efficiency class tropicalized. Integrated built-in Central Control Panels to operate the system and display its status. Each control panel have the HMI display unit. Overload protection for individual 3ph AC motors. Variable Frequency Drive (VFD) is provided for smooth start full motion and smooth stop for rack wheel motor / drive under carriage. Power Supply input output systems. Indicator Lamps. Proximity sensor along with reflector.PLC system to control with interlock for healthy operation. Anti-collision system is provided for smooth operation. (Retro reflective type proximity sensors). In case of failure of dc system, the unit bypass system is provided which will ensure uninterrupted work. Ethernet, Modbus inter unit communication. complete covered Control Panel. Electrical Cable covered by conduit pipe. All Proximities fully protected at each location. On each panel manual and auto mode switching operation is provided for the ease of operation. The infra-red photoelectric cell is placed at the base of each Drive Under Carriage, are composed of a projector and a receiver. When someone enters an aisle, the HPDS(Human Presence Detection System) detects their presence and automatically locks the maximus Motorized Mobile Palletized Racking System. The operator has to go to the central control panel press the RESET button. After only this the next operation or next movement will possible. When these push buttons are pressed the system immediately stops safely. The red emergency push buttons are located within each control board of the drive under carriage as well as on the control panel. Emergency push buttons shall be sealed for water and dust penetration, as chemical resistant. Emergency push buttons are provided on the upright channel in case of more than 3 bays. The drive under carriages are placed on the rails side by side. The spot control panels are mounted on the front of the racking super structure. 200 MM previous to the set of drive under carriages through beam sensor is provided. As soon as the System gets on this through beam sensor also gets on. if anybody try to cross this line this sensor detects the presence and stops the whole system immediately. on pressing the RESET BUTTON only you can again RESTART the system. All above safety sensors are connected to system in fail-safe mode. Each Mobile Rack is provided with push button panels at aisle entry point. Hence the Operators can always observe presence of any material / person in the racks while givingcommand to the racks to move. This system is having a safety gap of 200 to 300 mm between the two drive under carriages to have the safety of the person working in the aisles. The Drive Under Carriage, are provided with optical limit switch to stop the motion of the drive under carriage, will not allow to bang on each other.When Drive Under Carriage are move the blinking light and acoustic signal are automatically activated, as the warning signal for the operator.The acoustic signal starts on pressing the forward / Reverse button itself, thus allowing people to move or to press the emergency stop button in case of danger." Main Unit - Quantity : 54 Nos. Size :4800 MM H X 3480 MM W X 1000 MM D, Loading Level = 4,Load/Level = 1200 Kgs.UDL Size :- 33350 MM AddOn Unit - Quantity : 292 nos. Size :4800 MM H X 3480 MM W X 1000 MM D, Loading Level = 4,Load/Level = 1200 Kgs.UDL DRIVE UNDER CARRIAGE WITH PLC (DFMU-A) - Quantity : 11 Nos. Size :- 24680 x 2550 MM TRACK & BOLT - Quantity : 8 Nos DRIVE UNDER CARRIAGE WITH PLC (DFMU-B) - Quantity : 16 Nos. Size :- 21200 x 2550 MM TRACK & BOLT - Quantity : 14 Nos.
464Supply, Installation , testing & commissing of Space Maker Slotted Angle Rack.(LIQUID PAINT) SLOTTED ANGLE RACK.(F.F.) - Quantity : 426 Nos. Size :- 3000 H X 900 W X 450 D MM With 7 Panels 6 Compartment Load 150kgs.UDL TIE ANGLE - Quantity : 100 Nos.
465Supply, Installation, Testing & Commissioning of following equipments/System CANOPUS-ROLLER-3005 CANOPUS ROLLER Series Roller Chain Based Conveyor Conveyor Height (Infeed - Outfeed) (mm):800 +/- 50 mm Conveyor Length (mm):1000 Drive Type:Bonfiglioli Geared motor Load Capacity (kgs/mtr):50 Roller Width (mm):600 Conveyor Frame:MS Powder coated Side Guides Provided (Yes/No):NA Notes:Infeed Conveyor for Check Weigher (CV01) approved make - NIDO
466Supply, Installation, Testing & Commissioning of following equipments/System 60-1000X600 Check Weigher Conveyor Height (Infeed - Outfeed) (mm):800 +/- 50 Conveyor Length (mm):1080 Load Capacity (kgs/mtr):60 Roller Width (mm):600 Conveyor Frame:MS Powder Coated Side Guides Provided (Yes/No):na Notes:CV02 approved make - NIDO
467CANOPUS-ROLLER-3005 Supply, Installation, Testing & Commissioning of following equipments/SystemCANOPUS ROLLER Series Roller Chain Based Conveyor Roller Width (mm):600 Conveyor Frame:MS Powder coated Side Guides Provided (Yes/No):na Conveyor Height (Infeed - Outfeed) (mm):800 +/- 50 Conveyor Length (mm):1500 Drive Type:Bonfiglioli Geared motor Load Capacity (kgs/mtr):50 Notes:Ou??eed Conveyor + Pneuma??c Pusher (CV03) approved make - NIDO
468CANOPUS-ROLLER-3002 Series Supply, Installation, Testing & Commissioning of following equipments/System CANOPUS ROLLER Series Roller Gravity Conveyor Conveyor Height Range (mm):800 +/- 50 & 720 +/- 50 Conveyor Length (mm):1000 Load Capacity (kgs/mtr):50 Roller Width (mm):600 Notes:Gravity Conveyor (CV04)
469CANOPUS-ROLLER-3002 Series Supply, Installation, Testing & Commissioning of following equipments/System CANOPUS ROLLER Series Roller Gravity Conveyor Conveyor Height Range (mm):800 +/- 50 Conveyor Length (mm):1000 Load Capacity (kgs/mtr):50 Roller Width (mm):600 Notes:Rejection Gravity Conveyor (CV05)
470Supply, Installation, Testing & Commissioning of following equipments/Systemof AUX Auxillary Equipment Model:Videojet Print & Apply System with Conveyor/ Auxillary Equipment Model:NIDO Automatic Top Side Labelling Machine with Conveyor
471Supply, Installation, Testing & Commissioning of following equipments/SystemofCognex_DM363 Dataman Barcode Reader with kit - 363 series OEM Code:363 series Make:Cognex
472Supply, Installation, Testing & Commissioning of following equipments/System of control panel with laptop/desktop compatible to run the system complete with all detailing and as per the requirement.
473Supply, Installation, Testing & Commissioning of following equipments/Systemof Installation & Commissioning Charges
474Supply, Installation, Testing & Commissioning of following equipments/System Server (Admin area) IBM / Lenovo SR550: 7X04SFAM00: Intel Xeon Silver 42088C 85W 2.1GHz Processor , 32GB / 64 GB RAM Total)Ram , Open Bay , 2.5" SAS/SATA8-Bay Backplane, ThinkSystem RAID 530 -8i PCIe 12GbAdapter , Lenovo Xclarity Enterprise , 2 x 1G Port , 1 x 750w PSU + Additional 750 Redundant PSU, 3 Years 24x7  4Hr Response + KYD ( Keep your drive even if it fails ), Monitor 18.5", Keyboard /Mouse wired. Windows Svr 2019 Standard ROK 16C - Multi Lingual - 1 Nos ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD- 2 Nos ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD - 3 Nos Installation Charges Server - 1 Nos. location as per instructed by Client / PMC team.
475Network Switchs Providing & fixing of Switches:24 Ports: GS724Tv4 — 24-Port Gigabit Ethernet Smart Switch with 2 SFP Ports location as per instructed by Client / PMC team.
476Network Switchs Providing & fixing of KVM Switch location as per instructed by Client / PMC team.
477Providing & fixing of SECURITY FIREWALL Firewall Fortinet: FortiGate 40F Firewall. 5 x GE RJ45 ports (including 4 x Internal Ports, 1 x WAN Ports, with FortiGate 40F - FortiCare & FortiGuard location as per instructed by Client / PMC team.
478Providing & fixing of NAS STORAGE FOR BACKUP NAS Storage: SynologyDiskStation DS920+ Scalable NAS with 4 Drive Bays with 10TBEnterprise Hard Disk x 2 Nos.location as per instructed by Client / PMC team.
479Providing & fixing of UPS POWER BACKUP SYSTEM UPS 3 KVA with Backup 1 Hour: APC (Americal Power Conversion) 3KVASingle Phase with 12V / 100AH SMF x 6 Nos Exide Batterylocation as per instructed by Client / PMC team.
480Providing & fixing of All in one DESKTOP unit Personal computer design type All in One RAM Memory Installed Size 8GB licenced Operating System Windows 10 Home 64, English CPU Model Core i5 Make- Lenovo CPU Manufacturer Intel Screen Size 23.8 Inches location as per instructed by Client / PMC team.
481Providing & fixing ofLAPTOP system of following descripation Battery Cell-3 Cell with 65W- AC Adapter Processor - Core i7-1165G7 Processor, 11th Gen with Dedicated Graphic Memory Capacity-2 GB SSD Capacity-512 GB RAM-8 GB DDR4, Clock Speed-2.8 GHz with Turbo Boost Upto 4.7 GHz Graphic Processor-NVIDIA GeForce MX350 Port and Slot Features- Mic In, USB Port, HDMI Port, Multi Card Slot Screen size- 15.6 inch, Screen Resolution-1920 x 1080 Pixels Screen Type - Full HD LED Backlit Anti Glare Display (250 nits Brightness, 45% NTSC Color Gamut, IPS-level Panel) licenced Operating System Windows 10 Home 64, English location as per instructed by Client / PMC team.
482Providing & fixing of WIRELESS Router of following details Wifi +Access Points: Wifi Router Ceiling Mounted: Ruckus R310 Wifi Access Point with mounting Kit location as per instructed by Client / PMC team.
483Providing & fixing of EPABX / Telephony EPABX : Panasonic Hybrid IP PBX SystemModel KX NS 300 Rack Mount Kit - 1 Nos Panasonic KX T 7665 - 1Nos Panasonic KX DT 543(Panasonic digital PT with 6 lines LCD/24 FF Key) - 1Nos Panasonic Single Line Corded Integrated TelephoneModelKX-TS400 - 25 Nos MDF Box with Krone Module (100 Pair) - 1 Nos location as per instructed by Client / PMC team.
484Providing & fixing of Projector with Screen Epson Projector EB-E01 with5x7 Instalock Screen location as per instructed by Client / PMC team.
485Providing & fixing of Passive DATA AND VOICE Category 6 U/UTP Cable, LSZH, 1000 ft (305 m)-3050Mtrs,Category 6 U/UTP Information Outlet, Blue for Data and Voice-50Nos,Modular Shuttered Faceplate, Single port, white-19Nos,Modular Shuttered Faceplate, two port, white -14Nos,Modular Shuttered Faceplate, four port, white-1Nos,Cat6, 24 port Un-loaded Jack Panel-3Nos,Category 6 U/UTP Information Outlet,for Data and Voice-50Nos,Cat6 UTP Patch Cord, 7 ft (2Mtr) Blue Jacket-50Nos,Cat6 UTP Patch Cord, 3 ft (1 Mtr) Blue Jacket-50Nos location as per instructed by Client / PMC team.
486Providing & fixing of Passive CCTV Category 6 U/UTP Cable, LSZH, 1000 ft (305 m)-3660Mtrs,Category 6 U/UTP Information Outlet, Blue for Data and Voice-50Nos,Modular Shuttered Faceplate, two port, white - user end -25Nos,Cat6, 24 port Un-loaded Jack Panel-3Nos,Category 6 U/UTP Information Outletfor Data and Voice-50Nos,Cat6 UTP Patch Cord, 7 ft (2Mtr) Blue Jacket-100Nos location as per instructed by Client / PMC team.
487Providing & fixing of Fiber Back Bone 6 core Fiber SM armoured cable-280Mtrs,12F, 1U, LC SM OS2 , Loaded with Pigtails, Splice tray, adapter & splice protectors-1No.,6F, 1U, LC SM OS2 , Loaded with Pigtails, Splice tray, adapter & splice protectors-2Nos,LC-LC Singlemode Duplex Patch Cord, 3 Meter-4Nos location as per instructed by Client / PMC team.
488Providing & fixing of Extra material 9 U Wall mount Rack with all standard accessories 42 U Server Rack 800 x 1200 mm wih Standard Accessories 1" PVC Pipe with Accessories location as per instructed by Client / PMC team.
489Leased-line connection for internet supply, installation testing & commission of Fibre Leased Line 40 mbps2 Nos. - 2 Different ISP"s - 1:1 Dedicated Symmetric Data - Uptime 98% / Service Support Windows 24x7 - Charges inclusive installation. The point location instructed by client /PMC team. Note:- actual cost of this item will be arrived only after vendor onboarding and area served
490Installation & service charges Laying of Cat6 cables -6710Mtrs,I/O Terminations, faceplate/Jack Panel -200Nos,Modular Shuttered Faceplate, Single port, white-19Nos,Modular Shuttered Faceplate, two port, white -39Nos,Modular Shuttered Faceplate, four port, white-1No.,Cat6 UTP Patch Cord, 7 ft (2Mtr) Blue Jacket-150Nos,Cat6 UTP Patch Cord, 3 ft (1 Mtr) Blue Jacket-50Nos,6 core Fiber SM armoured cable-280Mtrs,12F, 1U, LC SM OS2 , Loaded with Pigtails, Splice tray, adapter & splice protectors-1No.,6F, 1U, LC SM OS2 , Loaded with Pigtails, Splice tray, adapter & splice protectors-2Nos,LC-LC Singlemode Duplex Patch Cord, 3 Meter-4Nos,Splicing of Fiber Core-24Nos,1"" PVC Pipe with Accessories-2780Nos,Testing of UTP Ports-50Nos,Patching, Dressing and Labelling of UTP ports-50Nos. Service Charges Installation Charges for NVR-1Nos,Installation Charges for cameras fixing with Connecotrs & Mounting Boxes & Accessories-25Nos. PROJECT MANAGEMENT Project management Charges-1set
491Supply, installation, Testing & commissing of Drive-Battery operated electric stacker (fork lift),Type of operation-Platform,Load Capacity-1600 kg,Load center-600 mm,Load distance, centre of drive axle to fork 647 mm,Wheelbase -1215 mm,Service Weight-1380 kg,Tyres-Polyurethane (PU),Tyre size, front -Ø230x70 (Ø X W (mm),Tyre size, rear-Ø85x75 (Ø X W (mm)),Support wheels-Ø150x54 (Ø X W (mm),Wheels, number front/rear(x=driven wheels)-1x+1/4,Lowered mast height(h1)-2108mm,Free lift(H2)= 1520 mm ,Lift height(h3) 4600mm,Extended mast height(H4)-5080 mm,Lowered height(h13)-90 mm,Overall length(I1)-1896 mm,Length to face of forks(I2) =746mm,Overall width(b1)=790 mm,Fork dimensions( L x W x T ) 1150 x 180 x 60 mm,Width over forks(b5)- 570 mm, Ground clearance, center of wheelbase(m2) = 28 mm,Aisle width for pallets 1000x1200 crossways (Ast)= 2325 mm,Aisle width for pallets 800x1200 lengthways (Ast)= 2290 mm,Turning radius Wa= 1420 mm,Travel Speed, laden/unladen = 7.0/8.0 km/hr,Lift speed, laden/unladen- 0.13/0.20 m/s,Lowering speed, laden/unladen-0.28/0.23 m/s,Max.gradient performance, laden/unladen- 6/12 %,Capacity @ max height -800 kg,Service brake- Electromagnetic,Drive motor rating (AC)- 1.4 KW,Lift motor rating (DC) -3.2 KW,Battery voltage, nominal capacity -24/280 V/Ah,Type of drive control-AC-Speed control,Controller make-ZAPI,Sound level-dB(A) <70
492Supply, installation, Testing & commissing of Battery operated Pallet Truck Power supply- Electric,operating type-Pedestrian/Stand,load capacity-2000Q kg,load center distance-600 C mm,weight(without battery)-650 kg,Axle loading,loaded drive end/load end-1110 / 1540 kg,Axle loading,unloaded drive end/load end-510 / 140 kg,tyres-Polyurethane,tyres size drive end-F210x70 mm,tyres size load end-F84x84 mm,balance wheel size-F100x40 mm,wheels number(x=drive wheel)drive end/load end-1X+2/4,lift height-120 mm,forks height,lowered-85 mm,height of handle in drive poistion(max/min)-950 / 1350 mm,overall length + platform-1790 mm,length to face of forks-640 mm,overall width-790 mm,fork dimensions-1150X173X55 mm,width over fork-540 mm,minimum ground clearance-30mm,aisle width for pallets 800x1200 lengthways-2290 mm,turning radius-1585 mm,travel speed loaded/unloaded-7.5 / 8 Km/Hr,lift speed loaded/unloaded-0025/0.030 m/s,lowering speed loaded/unloaded-030/.025 m/s .,max gradeablity loaded/unloaded-8 / 15 %,service brake-Electromagnetic,drive motor rating-1.4 AC kW,lift motor rating ( DC )-0.8 kW,battery voltage/nominal capacity-24V/210Ah V/Ah,type of drive control-Speed control,noise level at operator"s ear-DB(A) <69
493Supply, installation, Testing & commissing of Spare Battery for Electric Stacker Battery voltage/nominal capacity- 24/280 (V/Ah)
494Supply, installation, Testing & commissing of Spare Battery for Battery operated Pallet Truck BoPT Battery voltage/nominal capacity- 24V/210Ah (V/Ah)
495Supply, installation, Testing & commissing of Battery Changing Trolley
496Supply, installation, Testing & commissing of Hand Pallet Truck of Capacity-2500 kg,Lift height (h2)-200mm,Lowered fork height(H1)-85 mm,Fork length (L)-1150mm,Fork width-160mm,Width over the fork (W)-550mm,Steering whel (A)-Ø 200 mm,Fork wheel (B)-Ø 80 mm
497Supply, Installation, Testing & commissing of Injection Moulded Pallet dimension-size 1200 mm (l) x 1000 mm (w) x 160 mm,(h) approx.,length - 1200 mm width – 1000 mm,height – 160 mm,colour =blue / green,manufacturing process -one shot injection molded,material of construction -100% virgin food grade hdpe,type - non reversible, 3 longitudinal runners,surface -perforated top & bottom,entry -4 way entry, load bearing capacity-static – 4000 kg., dynamic – 1000 kg.,selective racking-750 kg,selective racking – 750 kg.,,mhe compatibility -suitable to handle with all kind of material handling equipments (manual pallet truck / forklift / reach truck and stackers
498Supply, installation, Testing & commissing of Strapping Belt
499Supply, installation, Testing & commissing of Waste Bin 240 liters
500GRC Design, fabrication, supply, installation, testing, protection, cleaning & handover of 15 - 20 mm thick GRC Panel cladding with filled joint system custom designed to withstand the design wind pressure confirming to IS -875 part III. (The system must pass the proof test at 1.5 times design wind pressure without any failure). The system should be designed to accommodate GRC panel of 15 - 20mm thick and minimum 40mm at fixing location using SDS Hilti make/equivalent, non staining weather sealants to seal the gaps between curtain wall and the building structure all complete required to perform as per specification and drawing in conjunction with BOQ. The system should be designed to accommodate surface temperatures up to 60°C and expansion contraction resulting from temperature differential of 60°C along with wind load, dead load and thermal loads. Any corner or junction slab which may be of smaller size should also be supported similarly. Rate should include to provide the GRC matching the groove / elevation lines , soffits , lintelsand sides to prevent water or any insects coming through the gap. The system should accommodatethe replacement possibility of damage GRC panel without disturbing any other panels. The complete system should be installed using proper scaffoldings. Any other form of access equipment if intended to be forwarded along with the structural stability and fit for safe working certificate by certified agency to PMC for their review and approval. Approval of such methods should be at description of PMC and client.
501M S fabrication Design, fabrication, supply, installation, testing, protection, cleaning & handover of required structural steel frame work in line with design drawings made out of MS pipe sections / I Beams / Channels / Plates of approved make make of first quality confirming to IS standard. The fixing of Frame structure should be either welded with main structure or with anchor fastener or as per design, The steel design should be accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure should be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron
502Semi unitized structural glazing system Design, fabrication, supply, installation, testing, protection, cleaning & handover ofthe Curtain wall / Semi unitized structural glazing system as per design intent and as per approved drawings, preparation of shop drawings, supply, fabricate the panel with the specified glass/Design pre-assembled aluminium Semi unitized Structurally glazed Panel with continuous framed panels / Strip window / Punched window system with split mullion to any shape and profiles shall be designed to with stand the design wind pressure as per IS code or relevant international code (Test pressure shall be 1.5 times of the design wind pressure)and fixed at horizontally / vertically / sloped / curved position etc as shown in the approved drawings by using Aluminium extrusions, Glass, Spacer tape, Gasket, Sealant etc. as specified. Contractor shall be responsible to determine the maximum design wind pressure and lateral forces, moments, stresses etc. applicable for the system. Negative / suction pressures if determined as per IS 875 and Lateral forces as per code IS 1893 shall make allowances as described in the code for corner effects on the system. System shall be designed with Air Pressure equalization chamber and concealed continuous gutter vertically and horizontally at all levels as self drainage barrier to achieve water tightness besides providing EPDM Gaskets on the frame and EPDM Gasket / Sealant on the external groove as air and water barrier. Submission of methodology for the Materials and assembly (Mock up & field test) supported by the copy of relevant codes & Standards and the same shall be got approved by the Client / PMC / Architect prior to testing. Protection of the System and Materials till handing over to the Client / PMC / Architect, removal of the unwanted materials, broken glass, Screws, bolts, Nuts, Packing Materials, debris etc
503FRP/GRP Pultrusion section Design, fabrication, supply, installation, testing, protection, cleaning & handover ofPultrusion section of 50x25 on Glass façade with both side adhesive tap and Adhesive/sealant dully filled for permanent fixing on Glass Façade as design indent, in requiredcolor. The Material shall have minimum 65% glass fiber and made in Isopthalic polyester resin UV added. The complete system shall be installed using proper scaffoldings. Any other form of access equipment if intended to be forwarded along with the structural stability and fit for safe working certificate by certified agency to PMC for their review and approval. Approval of such methods will be at description of PMC and client. Submission of methodology for the Materials and assembly (Mock up & field test) supported by the copy of relevant codes & Standards and the same should be got approved by the Client / PMC / Architect prior to testing.
504(A) FIRE ALARM SYSTEM: "Supply, installation, testing and commissioning of following as per specifications : FM /UL( 9 th edition),IntelligentAddressable Microprocessor supervised, modified two stage type with software package for programming based __ loop fire alarmcontrol panel expandable up to 10 loop & capacble of taking minimum 125 detectors and 125 devices per loop, and shall contain central processing unit, LCD display min 960 character with message transfer protocol arrangement to PA system and with Audio Source Unit w/ microphone fire fighters telephone jack provisions for telephone instrument as per the specification, complete with battery backup of 24 hours operation and 30 minutes alarm operation, with battery charger. The system shall have provision to integrate with life safety facilities i.e HVAC, lift or elevator by providing NO/NC contacts, IP based and BMS compatibility shall through MODBUS/ BACnet protocol. Panel shall be compatible for DC controllers & OFC integration with other manufacturer panel with necessary indications. Make - Edwards/Honeywell/Simplex/Siemens" 2 Loop Panel
505Supply, installation, testing and commissioning of following as per specifications ; Active Repeater panel with 960 Character LCD display complete system function keys for programming and control like system reset,Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc. as per specification. Make -Edwards/Honeywell/Simplex/Siemens
506Supply, installation, testing and commissioning of following as per specifications Intelligent Addressable Photo-electic type smoke detector (Above Fase ceiling / Below Fase floor) with bicolour 360 deg LED indication, electronic addressing,( no rotary or disp switches allowed) multiple sensitivity levels, pre-alarm option, non-volatile memory having provision for seld diagnostics and history log, dust and dirt resistant with dirft compensation, plug in design, with compatible mounting bases, Junction box and other accessories, as required and working on 19-24V DC supply, all complete as required. The detectors shall be UL Listed/ FM approved . Make - Edwards/Honeywell/Simplex/Siemens
507SITC Intelligent Addressable Heat detector with operating temperature of 57 deg C & 9 deg C rate of rise of temperature with bicolour 360 deg LED indication, electronic addressing,( No rotary or dip switches allowed) , multiple sensitivity levels, pre-alarm option, non-volatile memory having provision for seld diagnostics and history log, dust and dirt resistant with dirft compensation, plug in design, with compatible mounting bases, Junction box and other accessories, as required and working on 19-24V DC supply, all complete as required. The detectors shall be UL Listed/ FM approved. Make-Edwards/Honeywell/Simplex/Siemens
508SITC IntelligentAddressable Multi criteria detector with bicolour 360 deg LED indication, electronic addressing( no rotary or dip switch settings), multiple sensitivity levels, pre-alarm option, non-volatile memory having provision for self diagnostics and history log, dust and dirt resistant with dirft compensation, plug in design, with compatible mounting bases, Junction box and other accessories, as required and working on 19-24V DC supply, all complete as required. The detectors shall be UL Listed/ FM approved. Edwards/Honeywell/Simplex/Siemens
509SITC Addressable type Beam Detector of approved make, all complete as required with transmitter/ receiver & reflector. The unit shall be complete with Transmitter / receiver & reflectors, test stations.Edwards/Honeywell/Simplex/Siemens
510SITCAddressable Monitor Module, single output type, for monitoring the field devices, with LED status indication, automatic mapping device, electronic addressing and working at 24V DC and all othe accessories, all complete, as required. (for fire exit door panic bar alarm, fire pump monitoring). The module shall be UL Listed / FM approved. Make - Edwards/Honeywell/Simplex/Siemens
511SITCManual call point pull type, having dual pole (action) type combination of tripping contact one for loop and other for access controlled door and an integrally mounted addressable module, that monitors and reports the contact status. Make - Edwards/Honeywell/Simplex/Siemens
512SITCAddressable Electronic Hooter cum Strobe of 88dba/90dba and 15,30,75 & 110 cd, shall be UL Listed / FM approved with all required accessorieslike power supply. Make - Edwards/Honeywell/Simplex/Siemens
513SITC Addressable contol modules for Hooter cum Strobe with all required accessories Make - Edwards/Honeywell/Simplex/Siemens
514SITC Adressable Fault isolator module, capacble of monitoring shorted loop circuit and automatically restore communications, when shorted conditions are corrected with plug in arrangement, LED status indication and other accessories, all complete as required, working on 19 - 24V DC. The module shall be UL Listed / FM approvedMake - Edwards/Honeywell/Simplex/Siemens Make - Edwards/Honeywell/Simplex/Siemens
515SITC Response indicator with LED display for all detectors located above false ceiling Make - AGNI
516SITCAddressable Control Relay Module, for tripping the field devices, with LED indication, automatic mapping device, electronic addressing and working at 24V DC and all othe accessories, all complete, as required. (for AHU, Supply air fans, Exhaust fan, FCU, VHT systems). The module shall be UL Listed / FM approved . Make - Edwards/Honeywell/Simplex/Siemens
517SITC 2C x 1.5 mm2, Stranded Copper conductor, Type AST 1 PVC insulated, Armoured ZHFR Cable 650 V as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands, ABS Junction Boxes (wherever required), terminals, Ferruling complete. Make - KEI/Deepanjan/Saflex/RR Kabel/Polycab
518(B) PUBLIC ADDRESS SYSTEM SITC High quality type music speakers with fire dome to be fixed flushed with false ceiling with line matching transformer for direct connecting to 100/70 V output line. (EN54 approved) Ceiling speakers 6 Watts output with multiple tappings- EN 54 Approved with metal backbox
519SITC Metallic Grill, high quality type music speakers with fire dome to be fixed flushed with false ceiling with line matching transformer for direct connecting to 100/70 V output line. (EN54 approved). SITC Wall CabinetSpeakers Wall mounted - 6 Watts output with multiple tappings - EN54 approved
520"SITC Volume control - cum - ON - OFF switch flush mounted on wall along with other electrical switches with size & regulating knob matching the electrical fittings,upto 25 Watts Make - Ateis/Bosch/Honeywell"
521SITC 6 Zone Call Station with goose neck Microphone with zone selection & all call selection to be connected peer to peer with the network controller. Make - Ateis/Bosch/Honeywell
522" SITC of Master controller - 6 zone with following features- EN 54 Approved 6 ZONE VOICE ALARM CONTROLLER Microprocessor based MODBUS/IP or BACNET/IP Port for 3rd Party IBMS System Integration Accomodates 8 set of Amplifiers/ zones 2 Channel Operation for Simultaneous Evac & Alert Audio message broadcast 100% Redundancy in amplifier, Automatic Backup Switchover in case of failure of Main Amplifier. Accomadates 8 Zone Call stations &/or Touchscreen call station peer to peer Automated Evacuation message facility With all interconnecting Cables,rack mounted EN54-16 Compliant & Approved Make - Ateis/Bosch/Honeywell"
523SITC 480W Class D Power Amplifiers fully monitored speaker circuits MUILTI Channel + One redundant suitable to meet the speaker wattage230 VAC networkable with all interconnecting Cables - EN 54 Make - Ateis/Bosch/Honeywell
524SITC Rack to accommodate all above equipment with closed from 2 sides with 2 exhaust fans, powder coated complete-27U
525SITC2C x 1.0 mm2, Stranded Copper conductor, Type AST 1 PVC insulated, Armoured ZHFR Cable 650 V as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands, ABS Junction Boxes (wherever required), terminals, Ferruling complete. Make - KEI/Deepanjan/Saflex/RR Kabel
526SITC Rackmountable Music Source to play CD/ MP3/ Pendrive input
527(C) SPRINKLER SYSTEM: Supply, Errection and Testing of Heavy, ‘C’ class G.I. pipes IS 1239 with screwed or welded joints, preparation of Sprinkler pipe network as per plan, by cutting the pipes to correct lengths; and with G.I threaded or Socket Weld fitting used for pipe size up to 50 NB & below; and using butt welds for 65 NB & above. Presssure Testing of piping shall be given 10.5 kgs/cm2 pressure for 24 Hrs. Vendor shall submitt all the Manufacturing and Test certifiates with the delivery of pipes at site. MAKE - JINDAL / TATA / ZENITH : size: 25 NB
52832 NB
52940 NB
53050NB
53165NB
53280NB
533100NB
534150NB
535Supply Installation testing & comissioning of Pendant type sprinkler of 15 NB, Quartzoid bulb type 68 deg. Standard Response, with adjustable escutcheon plate in SS 304. MAKE - VIKING/TYCO
536Supply Installation testing & comissioning of Upright type sprinkler of 15 NB, Quartzoid bulb type 68 deg, Standard Response, with SS 304 sprinkler guard if required. MAKE - VIKING/TYCO
537SITCof Sprinkler Flexible drop pipes made of Corrugated, SS Braided Tubing to with stand 16 Bar pressure with welded reducer on one end to directly accommodate sprinkler & female check nut on the other end to connect to the branch pipe with supports complete with required accessories to fix on the False ceiling with adjustable SS bar and clamps.- UL LIsted MAKE - RAPIDROP/ TYCO/ VICFLEX / AGFLEX / YONGWONG Size: 1500 mm long
538SITC of Cast iron butterfly valve with Tamper Switch rated for pressure rating PN 16 kg/sqcm standard pattern (Horizontal / Vertical),with necessary flanged joints by providing necessary pair of M.S. flanges, nuts, bolts, gaskets, etc. all complete for MAKE - ZOLOTO/AUDCO/SIR Size: 150 NB
539100 NB
540SITC ofNon Return valves, dual Plate Type Body, Tested at 425 p.s.i. Hydraulic. low inertia disc design to enable the valve to open or close with a very low differential pressure at Sprinkler Tapoffs MAKE - ZOLOTO/AUDCO/SIR Size: 150 NB
541100 NB
542Supply, Installation, Testing and commissioning of Flow Switch Vane Type with dual potential free contact to monitored on the BMS system. MAKE - SYSTEM SENSOR/POTTER Size: 150 NB
543"SITC Providing and fixing 50 mm Test Valve Drain kit with sight Glass, Ball valve, Union & required fittings etc MAKE - ZOLOTO/GIACOMMINI
544SITC of 25mm dia Air Vent Valves at Sprinkler Tapoffs with Ball Valve.
545SITC of Pressure Guage 0 - 10 Kg / cm2, glycerin filled with mounting arrangement and ball valve. MAKE - FEIBIG/HGURU/OMICRON
546(D) ACCESS ONTROL SYSTEM: Supply and installation of Smart Card reader with read range of 3 to 4 inches (HID Compatible Readers) HID /SPECTRA / Honeywell / SmartI.
547SITC 32 BIT DOOR CONTROLLER Multiple card reading technologies supported, Proximity, Smart card, Biometric Variable card formats supported.Multiple facility codes supported Remote database administration Remote alarm monitoring Inbuilt database backup to facilitate offline use Local, Global, Soft, Hard Anti-pass back supported Automatic locking & unlocking of the doors HID /SPECTRA / Honeywell / SmartI. 2 DOOR SYSTEM
5484 DOOR SYSTEM
549SITC Biometric with Smart card Reader, Power supply with wiegand output fully networkable. (To include 1 set of Biometric enrolling kit complete ) HID /SPECTRA / Honeywell / SmartI.
550SITC Single Magnetic Lock with Door Position Switch
551SITC of Double Magnetic Lock with Door Position Switch
552SITC of Egress Switch
553SITC of Magnetic contacts and Piezo Sounders forFire Exits
554SITC Panic Bar with Hooters for all Emergency Exits / Local scare Alarm
555"SITC of Enterprise Access Control Software with 2 Client License loaded on Intel Xeon Server grade machine with 4 GB RAM & 240 GB Hardisk,with MS SQL Licensed Software & Operating System with following features: (Hardware in Client"s Scope)- iApp Integrated Application Muilticity,Muilti client Distributed intelligence for central & remote configuration. unlimited expansion Supports IP Series (Ethernet ready) controllers. Windows based Operator work stations. Automatic Server archive & back up ODBC Compliant Broadcast feature for central control on controllers & equipments Full reporting capabilities and custom reports Support upto 32 Clients HID /SPECTRA / Honeywell / SmartI.
556Supply installation, testing, commissioning of of AB Copper Armoured Cable PVC insulated/Flexible Cables in below Conduits shielded FRLS Sheathed Controller to Reader Cabling - 8C X 0.5 sq mm FRLS Shielded Armoured Cable
557Controller to EM Lock Cabling- 4C X 0.5 sq mm FRLS Shielded Armoured Cable
558Controller to Switch/Controller Cabling - 2C x 0.5 sq mm FRLS Shielded Armoured Cable
559Supply installation, testing, commissioning of Green ABS plastic Emergency Break Glass Units.
560Supply installation, testing, commissioning of EM RFID Cards suitable to work with installed readers.
561(E) FIRE EXTINGUISHER: SITC of ISI mark 4.5 KG CO2 fire Extingusher with wall mounting bracket. Make-Safex/Ceasefire/Minimax/Kanex
562SITC of ISI Marked 6 Kg ABC Type fire Extingusher with wall mounting bracket. Make-Safex/Ceasefire/Minimax/Kanex
563SITC of 10 KG Ceiling Suspended Modular Type Clean Agent Fire Extinguisher Make-Safex/Ceasefire/Minimax/Kanex.
564SITC of ISI mark 45 ltr Water type fire Extingusher with wall mounting bracket. Make-Safex/Ceasefire/Minimax/Kanex.
565Floor Mount MS Stands for the above extinguishers Make-Safex/Ceasefire/Minimax/Kanex
566(F) EXIT SIGNAGES: Supply installation, testing, commissioning of SURFACE MOUNT SINGLESIDED, Maintained 3 Watt LED, FIRE Exit luminaires, with Sheet metal Body, Painted to RAL 9010, Pictogram 280 (I) X 130 (W), Legend with clear acrylic/engraved pattern to be fully compliant with requirements of designing and installation to meet the fire and safety code of practice, IP 20 with NiCad 2 x 1.2V Battery Backup for 90 Minutes with operation in following formats as per Layouts :Right Arrow, Left Arrow, Down Arrow, Both sides etc. Input Supply : 220 V AC ±10% Make - Innoware / Cooper / Prolite
567Supply installation, testing, commissioning of FLUSH MOUNT DUAL SIDED, Maintained 3 Watt LED, FIRE Exit luminaires, with Sheet metal Body, Painted to RAL 9010, Pictogram 280 (I) X 130 (W), with spring supports, Legend with clear acrylic / engraved pattern to be fully compliant with requirements of designing and installation to meet the fire and safety code of practice, IP 20 with NiCad 2 x 1.2 V Battery Backup for 90 Minutes with operation in following formats as per Layouts :Right Arrow, Left Arrow, Down Arrow, Both sides etc. Input Supply : 220 V AC ±10% Make - Innoware / Cooper / Prolite
568Supply installation, testing, commissioning of A2 Size Fire Evacuation Maps with Acrylic sheet & necessary fitting for wall mounting. Make - Innoware / Cooper / Prolite
569Supply installation, testing, commissioning of Fire Extinguisher Signages Make - Innoware / Cooper / Prolite
570Supply installation, testing, commissioning of Aboveground Piping: Heavy, ‘C’ class M.S pipes , 6.3mm thick IS 1239 / IS 3589 with welded joints, including all fittings, MS rigid support for header and GI stud rod supports for branches, cutting the pipes to correct length jointing with M.S Butt Weld fitting, fixing with clamps to M.S. brackets / hangers including testing to 15 kgs/cm2 pressure , painting, inserted rubber gaskets with 2 coats of Zinc Dichromate primer and two coat of approved enamel paint.( PO red). MAKE - JINDAL / TATA / ZENITH Size: 80 NB
571Supply installation, testing, commissioning of Underground Piping: Heavy, ‘C’ class M.S pipes , 6.3 mm thick IS 1239 / IS 3589 with screwed or welded joints, including all fittings, MS rigid support for header and GI U bolt supports for header, cutting the pipes to correct length jointing with M.S Butt Weld fitting, fixing with clamps to M.S. bracketsGInutsbolts, washer including supporting/fixing. Pipe to be laid underground in 1 Mtr x 1 Mtr trench with 25mm sand bedding,with supply of sand & laying below the pipe including testing to 15 kgs/cm2 pressure , painting, inserted rubber gaskets with 15% of the field joints shall be radiographed for underground pipe if welding is permitted. MAKE - JINDAL / TATA / ZENITH Size : 150 NB
572SITC of 63mm Dia. Oblique type single headed Gunmetal Hydrantvalvewith female type instantaneous coupling includingrubber gasket, nuts, bolts,washers etc. with matching flanges asper IS 5290and as per specifications. Make - Shah Bhogilal / Newage / Monsher
573SITC of 63mm Dia. Oblique type double headed Gunmetal Hydrantvalvewith female type instantaneous coupling includingrubber gasket, nuts, bolts,washers etc. with matching flanges asper IS 5290and as per specifications. Make - Shah Bhogilal / Newage / Monsher
574SITC of 150mm dia, 4 - Way Fire Brigade inlet connection ,with Butterfly Valve complete Make - Shah Bhogilal / Newage / Monsher
575SITC ofProvidingand fixinglockable cabinet of size not less than0.9 x 0.6 x 0.5 mtr made out of MS Cabinet made from 2 mm thick MS sheet with glass door of thickness 6 mm central openingand with glass in doors embedded in EPDM (Two nos.)suitably markedon the outside with the letters "FIRE HOSE" including necessary lockingarrangement and shall be red in colour. The cabinet shall be painted with red color shade no. 536 as per IS: 5. A brick pedestal with brick wall with plaster shall also be constructed for supporting the FHC box. All surfaces shall be plastered with 1:4 ratio (1 cement: 4 fine sand) mortar. Make - Shah Bhogilal / Newage / Monsher
576SITC of non-percolating RRL fire hose pipe of Type II (as per IS : 636) of 63 mm dia and 15m length. The hose shall be rated for brust pressure of 42 Kg/sqcm. Hose shall be complete with ISI marked SS 304 male & femalecoupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire. Make - Shah Bhogilal / Newage / Monsher
577SITC of Gunmetal Male and female instantaneous type coupling as per I.S:903 withI.S. specifications
578SITC of Cast iron butterfly valve with Tamper Switch rated for pressure rating PN 16 kg/sqcm standard pattern (Horizontal / Vertical),with necessary flanged joints by providing necessary pair of M.S. flanges, nuts, bolts, gaskets, etc. all complete for MAKE - ZOLOTO/AUDCO/SIR HYDRANT SYSTEM Size: 150NB
579SITC ofNon Return valves, dual Plate Type Body, Tested at 425 p.s.i. Hydraulic. low inertia disc design to enable the valve to open or close with a very low differential pressure at Sprinkler Tapoffs MAKE - ZOLOTO/AUDCO/SIR Size: 150NB
580Supply, Installation , Testing and Commissioning of 44 KL Tank manufactured to International Quality Standards (AS 2304-2011 and AS/NZS 1170 - 2007) MOC shall be of TATA Bluescope/JSW Zincalume Corrugated WallTanks with following included: 44Kl Each - 5.6 Dia x 1.9 H Heavy duty corrugated Trapezoidal Galvalume dome roof with HDG roof trusses and lockable access hatch. Special quality Dust cum Vermin proof tape between the roof and tank wall. One 50mm scour drain assembly through floor of tank.One 150mm bell mouth over flow with assembly.M 12 HDG nuts and bolts covered internally with re-inforced tape. Special quality Mechanical Anchor Fasteners. One common external/internal ladder - hot dipped galvanized. INFINITY liner manufactured , re-inforced PE liner with METALLOCENE contact layer. ANSI/NSF - 61 certified.Supply of External Float and board type Level indicator. One special quality 400gsm Geosynthetic fabric on the base of the tank below the liner. All fitting and associated pipe work to be manufactured, Flanges to be A/S 2129 Table E and terminate 200mm from tank wall. Cost to be included with one interconnection between two tanks and 2/3 nozzles for each tank of 250mm size. All related civil works for foundation shall be included in the given offer. Any other required item to complete the above given scope for the fire water tank shall be included in the given offer. Level IndicatorMake - Rihno/Modular Tanks Pvt Ltd / Ben & Gaws 100 KL Each
581Supply, installation, testing & commissioning of Ambiator unit Two stage evaporative cooling system of blow through type with single tire arrangement with weatherproof canopy. Unit shall be in double skin construction made of Extruded Hollow Aluminium profile structure with Nylon connectors. AHU outer skin made of(22G) pre-coated galvanizedsheet steel of grey white color and Inner Skin made of(22G)Plain GI sheet steel. The panel should have CFC free PUF Insulation to density of 38-42Kg/m3 in double skin panels 23±1 mm thick. The unit bottom panel shall be made of 2mm thick Aluminium chequered sheet. The base frame shall made of of GI 16swg (1.6mm) with die cast AL. connectors. The unit shall have low leakage aluminum damper at outlet. Unit shall consists of following section viewing from fresh air entry side. 1.Filter section 10 micron filters section shall have GI louvers at fresh air suction for outdoor placed unit.The filters shall of panel type construction comprise of washable HDPE sandwiched media of 5 microns after wet section. The filters frame made of GI. The velocity across filters not more than 2.5 m/sec. Make -AAF/mechmaark 2.Blower and motor section The unit shall have dynamically balanced, AMCA certified PLUG type fan of suitable capacity to handle primary and secondary air. The secondary airtravels upwards through secondary paths thereby establishing the heat transfer process and exhausted out.The unit shall have limit switch shall be interlock with fan section. The motor shall beTEFC 4P, Class F insulation, Duty-S1 continuous, IP55 protection with VFD. Blower Make - Kruger/Nicotra/EQ. Motor make - ABB/Siemens, VFD Make - ABB / DANFOSS (HVAC SERIES) Accessories: Electrical control panel with PLC. The electrical panel should control temperature and Rh. Panel shall be Non - Compartmentalized panel and should have RYB indication -Indication lamps, Incomer-SFU Blower/Pump controls- Thru" -MPCB, Contactor with OLR, Digital display- VAF meter, PLC -for logic control, Sensor- Temp./Rh for logic control (4-20mA) Marine light with limit switch across fan section door shall be provided with switch for marine light on / off outside the unit. All Cable & pipes should be Roxtec flexible sealed type. Antivibration Rubbber Pads for MountingUnits Noise level should be less than 65db @ 1 mtrs Required nomenclature for each section of unit with direction Arrows indicating air flow. Make - HMX , DRI 3.Wet section a. Indirect (Sensible) heat exchanger section Air to air cross flow plate type heat exchanger made of Engineering polymer with thermally fused Non-woven-cartridges. The maximum efficiency of heat exchanger shall be 80% during peak summer design conditions. b. Direct (Adiabatic) heat exchanger section Made of Treated and impregnated special cellulose material with saturation up to 90%. The size of heat exchanger shall have thickness of 200 mm with 7mm flute. c. Tank - The water tank shall be made up of 18SWG (1.2mm) thick SS 304 plain sheet to house both sensible and adiabatic heat exchangers. d. Pump-The unit shall have two numbers of recirculation pump of submersible type and of approved make. Pump body, suction grill, seal housing disc and motor casing made of SS 304. The Impeller, nozzle and motor cover shall made of technopolymer reinforced with fibreglass. The pump motor shall have Class of insulation F, IP68 Protection rating and 230V ±10%, 50 Hz single phase voltage. The pump motor shall be minimum 1/3HP, 0.3 Kw, 230 Volts, 50 Hz single phase motor. The motor shall be supplied with built-in thermal protection with automatic reset and shall be rated for continuous duty. The unit shall have strainer for pump made of SS 304 with 2mm hole perforation. e. Piping - The piping shall be used of rigid UPVC material. Piping connections should be made so as to ensure uniform distribution of water. The sump shall be fitted with float valve. f. UV filters- Unit shall have UV filter for re-circulation line.UV filtration controls the bacterial disinfections in the supply water line thereby restricting the growth of algae and fungus. g. Mise eliminator- The unit shall have single bend mist eliminator made of GI precoated sheet.
582Supply, installation, testing and commissioning of Double Skin Ventilation unit for Exhaust HORIZONTAL, double skin air handling unit in 24±2 mm thick puff insulation complete with thremal break profile ,24 G insideGI sheet and 24 G GI outside sheet with pre-coating with flowing section.(Puff Density :-- 38±2 kg/cu.m) AHU frame work shall be of Anodized Aluminum construction with thermal break profile & internal covingComplete with fan section with Plug type fan,drive motors and accessories.,With Safety wire mesh guard for Motor. Along with Suitable capacity ofVFD(VFD Make - Danfoss)Pre filter section with G-4 (10µ)-90% Efficiency washable filter rating and PVC ports for pressure drop measurement as per specificationsUnit frame work shall be of Anodized Aluminum construction.Provide Digital Magnehelic gauges across the filters.(For BMS compatibility)Noise level should be less than 65db @ 1 mtrs
583Supplyinstallation testing and commissioning of GI Site Fabricated Ducting as per SMACNA & leakagetest as per SMACNA with RTV sealant & 3 mm thk food grade quality Neoprene Rubber gasket strips, GI nut-bolts etc. as per the following quantities : The ducting shall include GI threded supporting rods ,bends,tees, elbows,Y piece, taper pieces, turning vanes, reducer,expander, blind flanges etc.All MS parts should be painted with two coats of red oxide and two coates of black enamel paints.as per the following quantities GI Site Fabricated Ducting 18 Guage
584SITC of GI Site Fabricated Ducting 20 Guage
585SITC of GI Site Fabricated Ducting 22 Guage
586SITC of GI Site Fabricated Ducting 24 Guage
587Supplyinstallation testing and commissioning of GI Round duct Pre Fabricated Ducting 18 guage as per SMACNA & leakagetest as per SMACNA with RTV sealant & 3 mm thk food grade quality Neoprene Rubber gasket strips, GI nut-bolts etc. as per the following quantities : The ducting shall include supporting rods ,bends,tees, elbows,Y piece, taper pieces, turning vanes, reducer,expander, blind flanges etc.All MS parts should be painted with two coats of red oxide and two coates of black enamel paints.as per the following quantities SITC of GI Round duct Pre Fabricated Ducting 18 Guage
588SITC of GI Round duct Pre Fabricated Ducting 20 Guage
589SITC of GI Round duct Pre Fabricated Ducting 22 Guage
590SITC of GI Round duct Pre Fabricated Ducting 24 Guage
591Supplyinstallation testing and commissioning of Duct Insulation Supply air duct 19mm thk. with site-glued, Aluminum foil faced; Nitrile Rubber Insulation of suitable density (40 - 60 kg / m³) , class O insulation as per thickness specified (Measurment as per finished surface only. Not as per BIS) Recommended Makes: Armacell or equivalent.
592Supplyinstallation testing and commissioning of Duct Insulation Return air duct 13mm thk. with site-glued, Aluminum foil faced; Nitrile Rubber Insulation of suitable density (40 - 60 kg / m³) , class O insulation as per thickness specified (Measurment as per finished surface only. Not as per BIS) Recommended Makes: Armacell or equivalent.
593Supplyinstallation testing and commissioning of Duct Insulation 3mm thk. for joints and corners with site-glued, Aluminum foil faced; Nitrile Rubber Insulation of suitable density (40 - 60 kg / m³) , class O insulation as per thickness specified (Measurment as per finished surface only. Not as per BIS) Recommended Makes: Armacell or equivalent.
594Supply installation testing and commissioning of Supply Air Diffusers of Extruded Aluminium powder-coated complete with Volume controlled damper (VCD)
595Supply installation testing and commissioning of Return Air Diffusers of Extruded Aluminium powder-coated complete with Volume controlled damper (VCD)
596Supply installation testing and commissioning of Supply Air Diffusers of Extruded Aluminium powder-coated complete without Volume controlled damper (VCD)
597Supply installation testing and commissioning of Return Air Diffusers of Extruded Aluminium powder-coated complete without Volume controlled damper (VCD)
598Supply installation testing and commissioning of Supply Air Grill of Extruded Aluminium powder-coated complete with Volume controlled damper (VCD)
599Supply installation testing and commissioning of Return Air Grill of Extruded Aluminium powder-coated complete with Volume controlled damper (VCD)
600Supply installation testing and commissioning of Supply Air Grill of Extruded Aluminium powder-coated complete without Volume controlled damper (VCD)
601Supply installation testing and commissioning of Return Air Grill of Extruded Aluminium powder-coated complete without Volume controlled damper (VCD)
602Supplyinstallation testing and commissioning of Jet nozzles for Air washer unit complete with all necessary fittings and asscessories. SITC Jet nozzles 400mm dia.
603SITC Jet nozzles 300mm dia.
604SITC Jet nozzles 200mm dia.
605Supplyinstallation testing and commissioning of Fire Dampers with limit switcth fusible link type.interlocked with blower motor for RA (sutaible for actuator) complete with all necessary fittings and asscessories.
606Supplyinstallation testing and commissioning of Fusible link with cable terminal box for fire dampers complete with all necessary fittings and asscessories.
607Supplyinstallation testing and commissioning of Thyristor Controlled Electrical Heater (Tubular type) complete with all necessary fittings and asscessories. SITC Thyristor Controlled Electrical Heater (12 kw X 3 Nos)
608SITC Thyristor Controlled Electrical Heater (10 kw X 3 Nos)
609Supplyinstallation testing and commissioning of HVAC electrical panel boards for AHUs, re-heaters,exhaust fans, etc. Complete with incoming and outgoing feeders with ACB/SFU, Aluminium busbars, indicating lamps, digital type voltage, current & energy meters, etc. Necessary contactors, relays, changeover switches, etc. for interface with AHU Controller/Control System (BMS) to be provided as per requirement of the respective Controls/Control System. All AHU with the VFDs, also consider PID controller for Temp. & RH with sensor.
610Supplyinstallation testing and commissioning of Power Cabling: Armoured Aluminium/Copper power cabling between HVAC equipment, controls, controllers, HVAC panel boards; including terminations: All Cables XLPE. (*Indicative Cable sizes are given in Schematic Electrical Diagram. Contractor to be confirmed & quantified cables requirements based on HVAC Equipment locations.) Cabling from starter panel to AHU in HVAC contractor scope. Panels to be mounted near to AHU"s. Al armoured XLPE insulated cable 3.5 Core X 25 Sq.mm
611Al armoured XLPE insulated cable 3.5 Core X 35 Sq.mm
612Al armoured XLPE insulated cable 3.5 Core X 50 Sq.mm
613Al armoured XLPE insulated cable 3.5 Core X 125 Sq.mm
614Supplyinstallation testing and commissioning of Power Cabling: Armoured Aluminium/Copper power cabling between HVAC equipment, controls, controllers, HVAC panel boards; including terminations: All Cables XLPE. (*Indicative Cable sizes are given in Schematic Electrical Diagram. Contractor to be confirmed & quantified cables requirements based on HVAC Equipment locations.) Cabling from starter panel to AHU in HVAC contractor scope. Panels to be mounted near to AHU"s.: Cu armoured XLPE inulated cable 2 Core X 1.5 Sq.mm
615Cu armoured XLPE inulated cable 3 Core X 1.5 Sq.mm
616Cu armoured XLPE inulated cable 3 Core X 2.5 Sq.mm
617Cu armoured XLPE inulated cable 3 Core X 4 Sq.mm
618Cu armoured XLPE inulated cable 3 Core X 6 Sq.mm
619Cu armoured XLPE inulated cable 3 Core X 10 Sq.mm
620Cu armoured XLPE inulated cable 3 Core X 16 Sq.mm
621Cu armoured XLPE inulated cable 4 Core X 4 Sq.mm
622Supplyinstallation testing and commissioning of Control Cabling: Cu Shilded armoured XLPE insulated cable for control cabling between HVAC panel boards, equipment, controls, cutouts, interlocking, local isolators, etc Cabling from starter panel to AHU in HVAC contractor scope. Cu Shilded armoured XLPE insulated cable 2 Core X 1.5 Sq.mm
623Cu Shilded armoured XLPE insulated cable 3 Core X 1.5 Sq.mm
624Cu Shilded armoured XLPE insulated cable 4 Core X 2.5 Sq.mm
625Supplyinstallation testing and commissioning of Earthing: GI double earthing for HVAC equipment & controls complete with all fittings and accessories. 1 Core X 2.5 Sq.mm(green cable)
626SITC 25 x 3 mm GI flat
627Supplyinstallation testing and commissioning of Local Push Buttons: Weather-proof local ON-OFF push button stationwith lockable OFF button forunits located on terrace area (away from the respective panel boards for units) Complete with mounting stand. (Control cabling between push-buttons and respective panel board to be included in Control Cabling item)
628Supplyinstallation testing and commissioning of Airflow Sensor with transmitter: Duct mounted airflow sensor with transmitter to measure the cfm. The range from 250fpm to 15000 fpm. Probe must be aligned with airflow.
629Supplyinstallation testing and commissioning of Cable Trays: GI perforated cable trays in Utility room for chiller, cooling towers, pumps, AHUs, ventilation units etc., for laying power & control cables between HVAC panel boards & equipment; including hardware, accessories like bends, tee’s, supports, etc. GI Perforated 50 mm deep Cable Tray Upto 100 mm wide
630SITC GI Perforated 50 mm deep Cable Tray Upto 150 mm wide
631SITC GI Perforated 50 mm deep Cable Tray Upto 200 mm wide
632SITC GI Perforated 50 mm deep Cable Tray Upto 300 mm wide
633Split Air Conditioner Supply, Installation, Testing & Commissioning of Split Air conditioner complete with compressor, Air cooled condenser, first charge of refrigerent, refrigerant piping duly insulated of 5.0mt. length per circuit interconnecting IDU & ODU, expansion valves, filter. 5 star rating with green gas refrigerant. MAKE- DAIKIN,VOLTAS,LG. SITC Split Air Conditioner 1 TR
634SITC Split Air Conditioner 1.5 TR
635SITC Split Air Conditioner 2.0 TR
636SITC Split Air Conditioner 2.5 TR
637Copper Pipes Supply, Installation, Testing & Commissioning of copper Refrigerant Piping of OEM approved thickness suitabke for R410a refrigerant of suitable size as required and duly insulated with 19mm/13mm thick closed cell elastomeric nitrile insulation for gas/liquid pipes respectively.
638Supplyinstallation testing and commissioning of R410A Refrigerant Gas Charging with N2 Pressure Testing, Vaccuming etc including all fittings accessories complete with all material and labour as directed by the EIC
639Supplyinstallation testing and commissioning of Drain Pumps for Split Units including all fittings accessories complete with all material and labour as directed by the EIC
640Supplyinstallation testing and commissioning of U-PVC Pipe with U-trap for AHU drainand ambiator water supply with 9 mm thick nitrile rubber without Al foil complete with all material and labour as directed by the EIC UPVC Pipe 65 mm Dia.
641SITC UPVC Pipe 50 mm Dia.
642SITC UPVC Pipe 40 mm Dia.
643SITC UPVC Pipe 32 mm Dia.
644SITC UPVC Pipe 25 mm Dia.
645Supply installation testing and commissioning of 3 core x 2.5 sq.mm Cu armoured XLPE insulated cable between HVAC equipment, controls, controllers, HVAC panel boards; including terminations: All Cables XLPE. (*Indicative Cable sizes are given in Schematic Electrical Diagram. Contractor to be confirmed & quantified cables requirements based on HVAC Equipment locations.) Cabling from starter panel to AHU in HVAC contractor scope. Panels to be mounted near to AHU"s.
646Supply installation testing and commissioning of 2 core x 1.5 sq.mm Cu Shilded armoured XLPE insulated cable for controling cable between HVAC equipment, controls, controllers, HVAC panel boards; including terminations: All Cables XLPE. (*Indicative Cable sizes are given in Schematic Electrical Diagram. Contractor to be confirmed & quantified cables requirements based on HVAC Equipment locations.) Cabling from starter panel to AHU in HVAC contractor scope. Panels to be mounted near to AHU"s.
647Supplyinstallation testing and commissioning of PAINTING & TAGS Painting of the HVAC equipment & piping, equipment identification tags (stickers) for all HVAC equipment and directional arrows for ducts & pipes inclding all fittings, accessories, labour ,etc. complete as directed by the EIC.
648Supplyinstallation testing and commissioning of Structural Support inclding all fittings, accessories, labour ,etc. complete as directed by the EIC.
649Supplyinstallation testing and commissioning of DOCUMENTATION OF HVAC SYSTEM CHARGES FOR QUALIFICATION DOCUMENTATION ASSISTANCE OF ENTIRE HVAC SYSTEM IN ACCORDANCE TO TENDER SPECIFICATIONS. DOCUMENTATION). Mainly covers following inclding all fittings, accessories, labour ,etc. complete as directed by the EIC. DQ (Design Qualification) QAP (Quality Assurance Plan) IQ (Installation Qualification) OQ (Operation Qualification) PQ (Performance Qualification)
650Providing & fixing double skin partitions ofGPSP-G.I.(120GSM Zinc coated) polyester powder coated (Jouton or equivalent make 60-80 micron thickness) sheets of 0.8 mm thickness on both sides with infill of Puff (38 + 2 kg/cum density), silicon sealant filling at joints, heavy duty GI conduits 2 no"s every panel, include cut-out & flashing plate for fixing module, raised floor track for level adjustments, accessories, staging, scaffolding, all inclusive. Upto 4 Mtrs height Panel should be in single sheet only. Panel Thickness: 150 mm MODULAR PARTITIONS (PUFF INFILL)
651Providing & fixing of Curved double glazed view panelssize 900 X 1800 X 150 mm with jambs using 6mm toughened glass having 20mm ceramic paint black border & flushed on both sides with double side adhesive 3M tape and the edges sealed with silicon sealant, GPSP-GI powder coated 1mm thk sheets inside with curved corners, staging, scaffolding, all inclusive. (In case of similar width of view panel & partition panel, deduction for the view panel size will be done in measurements of the partition panel.)
652Providing & fixing ofQuick action-High speed rolling shutter door size 3000 x 3000 mm along with safety sensors, Transarent window. Side motor with controller along with motor cover, opening and closing speed as per standard. Control panel consist of adjustable timer, ON OFF push button and emergency button for stop. flexible curtain in self-extinguishing material (location -Internal use) Door in Partition (150 MM) (Clear opening)
653Supply, Installation, Testing & Commissioning of following equipments/System A-Solar PV Module (100 Kwp) Module-Polycrystalline / monocrystalline indian make / equivalent DCR Type-299Nos. B-Solar Inverter Solar String Inverter 100 KWp-1Nos.,Solar String Inverter 27 KWp0Nos.,Remote Monitoring System 0Nos. C-Module Mounting Structure Aluminium Structure Material with all Hardware & Accessories-1Lot,Aluminium Structure Material with all Hardware & Accessories-1Lot,Aluminium Structure Material with all Hardware & Accessories0Lot,HDG Structure Material with all Hardware & Accessories0Lot,FRP Walkway -300Mtr G-Earthing & Lightning Protection Earthing Kit (3 mtr x 17.2 mm Copper Bonded electrode) with 1 Chemical Bag -7Nos.,CI Earth Pith Cover -7Nos.,LA - ESE Type-1Nos.,GI Earthing Strip (25 mm x 3 mm)-140Kgs,35 sq. mm Copper Flexile Cable -10Mtr.,Insulators with Hardware for 25x3 Flat-200Nos.,Earthing Slevees-6Roll,5x15 mm Nut Bolt Set SS 304 (Module to Module Earthing)-540Nos.,SS Nuts and Bolts 8 mm x 25 mm (For Earthing Flat)-50set ,SS Nuts and Bolts 10 mm x 40 mm-10set. H-BOS Electrical : AC Side & DC Side Conduit Pipe-300Mtr.,Conduit Pipe Fitting _Bend_-35Nos.,Conduit Pipe Fitting_3Way Junction Box_Dia 32mm0Nos.,Conduit Pipe Fitting_4Way Junction Box_Dia 32mm0Nos.,Conduit Pipe Fitting_Coupler_-10Nos.,Flexible Conduit Pipe For DC Cabling_Dia 32 mm0Mtr. Saddle Clamp_20mm0Nos.,Conduit PipeFor DC Cabling( Pipe) Dia 25mm-50Mtr.,Conduit Pipe Fitting _Bend_Dia 25mm-30Nos.,Conduit Pipe Fitting_3Way Junction Box_Dia 25mm-15Nos.,Conduit Pipe Fitting_4Way Junction Box_Dia 25mm-15Nos.,Conduit Pipe Fitting_Coupler_Dia 25MM-15Nos.,Flexible Conduit Pipe For DC Cabling 0Mtr.,Saddle Clamp_25mm0Nos.,Conduit PipeFor DC Cabling( Pipe) Dia 20mm-210Mtr.,Conduit Pipe Fitting _Bend_Dia 20mm-60Nos.,Conduit Pipe Fitting_3Way Junction Box_Dia 20mm-15Nos.,Conduit Pipe Fitting_4Way Junction Box_Dia 20mm-15Nos.,Conduit Pipe Fitting_Coupler_Dia 20MM-30Nos.,Flexible Conduit Pipe For DC Cabling -50Mtr., Saddle Clamp_20mm-50Nos.,Cable Tray (75X50mmx1.2mm)-170Mtr.,Cable Tray (100x75mmx1.2mm)-25Mtr.,PVC jointing solution-3Nos.,300MM cable tie-15pkt. D-Civil Work (RCC Foundations) RCC Block Foundations Module Mounting for RCC Roof)0Nos.,LA Foundation-1Nos.,Earthing Chembers With Bricks-7Nos., E-ACDB, DCDB, Energy Meters & Others Electricals Panels DCDB (6IN - 6Out)0Nos.,ACDB (1IN - 1Out)-1Nos.,Solar Generation Meter -1Nos.,CT"s For Solar Genration Meter 250/5 A 0.5 S Class A -3Nos.,Encloser for Solar Genration Meter With MCCB & CT Provision-1Nos.,HT Net Meter-1Nos.,MCCB315 A -1Nos., F-Cables & Connectors (ACSide, DC Sides & Earthing) 1C X 4 SQMM Cu.cable (Array Interconnection to Inverter)-2600Mtr.,MC-4 Cable Connectors ( Pairs)-80Nos.,4C x 10 SQMM, Cu Flexible Cable (Inverter to ACDB)-8Mtr.,4C x 50 SQMM, Cu Flexible Cable (Inverter to ACDB)-8Mtr.,3.5C x 150 SQMM, AL XLPE armored Cable (ACDB- Generation Meter- Existing LT Panel )-50Mtr.,12 C x 2.5 Sq.mm Copper Cable for CT connections-8Mtr.,1Cx 4 Sq. Mm Cu Flexible Cable -100Mtr.,PG Gland - 4 x 10 Sqmm Cu Cable-2Nos.,PG Gland - 4 x 50 Sqmm Cu Cable-2Nos.,SS Gland D/C - for 4C x 150 SQMM Cable-4Nos.,Lugs_Cu_RT_10Sqmm-10Nos.,Lugs_Cu_RT_50Sqmm-10Nos.,Lugs_Alu_RT_150Sqmm-12Nos.,Lugs_Alu_RT_70Sqmm-4Nos.,Lugs_Cu_RT_2.5Sqmm-24Nos.,Lugs_Cu_RT_4Sqmm-540Nos. I-Data Acqusition Remote Monitoring & Control,CAT 6 Cable for Online Monitoring 0M,RJ 45 Connector- 0nos. J-Other Accessories : Insulation Tape (R, Y, B, Bl, G)-30Nos.,Ferrules-3set,Silicon Sealent -10Nos.,Caution Sticker-3Nos.,Zinc Spray -2Nos.,Al. Paint-2Ltr,Fastners-15Nos.,Do"s and Dont"s Board -1Nos. K-Installations/Commissioing Liasoning /Approvals-1LS,Travelling & Petty Cash for Engineers -1LS,Transportation of BOS & Misc. Materials -1LS,Installation and commissioning work -100.165KW
654Providing & fixing of 6mm White Acrylic Be ground& Logo 8mm & Fitting your Sideas per your Requirements. ( Size In Inches 18” x 15” )(450mm x 381mm). complete as per instruction of Engineer In Charge.
655Providing & fixing of6mm White Acrylic Be ground & logo 8mm & Fitting your side as per your Requirements.( Size In Inches 48” x 40” ) (1200mm x1200mm) complete as per instruction of Engineer In Charge.
656Providing & fixing of 3mm Ms Metal Letter & Logo with Pu Color Coating With 2” ACP Board as per your Requirements.( Size In Inches 18” x 15” ) (450mm x381mm) complete as per instruction of Engineer In Charge.
657Providing & fixing of 3mm Ms Metal Letter & logo with Pu Color CoatingWith 2” ACP Board as per your Requirements. ( Size In Inches 48” x 40” ) (1200x1200 ) complete as per instruction of Engineer In Charge.
658Providing & fixing of 24” height Ms Metal Letter (letter depth 2”Box Letter) Letter Pu Color Coating with fitting your Side wall&Your Logo(LogoSize 42” Height x width 35”) Logo 3mm Ms Metal Letter & Logo Pu Color Coatingwith 2” ACP Boardfitting on wall as per requirements. (Board Size in Inches 1205” x 48”) (30600 X 1200 mm) complete as per instruction of Engineer In Charge.
659Providing & fixing of 24” height Acrylic Letter(letter depth 2” Box Letter)Letter with fitting your Side wall& your logo-(LogoSize 42” Height x width 35”) Logo 3mm Acrylic Letter & Logo with 2” ACP Board fitting on wall as per requirements. (Board Size in Inches 1205” x 24”) (30600x600mm) complete as per instruction of Engineer In Charge.
660Providing & fixing of Nightglow with 6mm white Acrylic be ground, Stickers as per your Design. “Safety Sign” complete as per instruction of Engineer In Charge.
661Providing & fixing of Hanging Rops for Board complete as per instruction of Engineer In Charge.
662Providing & fixing of Toilet Singes Sign with Fitting your Side as per Requirements.(Size-8"x8") complete as per instruction of Engineer In Charge.
663Providing & fixing of Pull & Push Sign With Fitting your Side as per your Requirements.(Size 3"x3") complete as per instruction of Engineer In Charge.
664Providing & fixing of Scaffholding complete as per instruction of Engineer In Charge.
665Motorised Sliding Gate Supply, Installation, Testing & Commissioning of following equipments/System Size:- Opening Width - 5000 mm Total Width - 6200 mm (including 1200 mm overlapping) Height - 1500 mm Description :- Gate material :- Outer Frame : 100*50*3 mm thick Infills Thick : 50*50*3 mm thick Approx weight :Up to 920 kg. Gate operator : Sliding Gate Operator Upto 2100 kgs lever-operated limit switch, built - in control panel and radio receiver. Include:- Safety Sensor - 1 Pair ,4 module M.S rack - 6 mtr Technical specification Supply-220 V, 50 Hz , Rated Power-800 W ,Gear Ratio-1:30, Gear-Z16 Max. Torque-43 Nm, Max linear force-1350 N Thermal Protection-125 degree celsius, Intensity-70 % Operating Temp--40 to +40 degree celcius Degree of protection-IP 54
666Wicket Gate Supply, Installation, Testing & Commissioning of following equipments/System Size :- Opening Width - 1000mm Height - 1500 mm Approx weight up to 120kg Gate material : Outer Frame : 100*50*3 mm thick Infills Thick : 50*50*3 mm thick
667Motorised Sliding Gate Supply, Installation, Testing & Commissioning of following equipments/System Size:- Opening Width - 4000 mm Total width - 5200 mm (including 1200 mm overlapping) Height - 1500 mm Description :- Gate material : Outer Frame : 100*50*3 mm thick Infills Thick : 50*50*3 mm thick Approx weight :Upto 820 kg. Gate operator : Sliding Gate Operator Upto 2100 kgs lever-operated limit switch, built - in control panel and radio receiver. Include:- Safety Sensor - 1 Pair, 4 module M.S rack - 7 mtr, Optional Accessories on additional cost :Remote, Blinker, Hooter, Technical specification, Supply-220 V, 50 Hz , Rated Power-800 W, Gear Ratio-1:30, Gear-Z16, Max. Torque-43 Nm, Max linear force-1350 N, Thermal Protection-, 5 degree celsius, Intensity-70 %, Operating Temp--40 to +40 degree celcius, Degree of protection-IP 54
668Motorised Rolling Shutter (with Interlocking) Supply, Installation, Testing & Commissioning of following equipments/System Size - W 3000 mm * H 3000 mm Material:- GI with Powder coating. Includes :- - 1 mm special interlocking laths to make the shutter curtain of GI slats - Special shaft - Top Cover made upto 1.0 mm Thick GI - Side Guide of 75 * 2.5 mm thick MS with powder coated Motor Specifications Shaft-55mm Max Torque-1100 Nm Rated Torque-950Nm Output rpm-10 Working voltage-230 v , 50 Hz Duty cycle-S 3-60% Operating temp.-5celcius to 50 celcius Noise dB (A)-<70 Protection rating-IP 54
669Hydraulic Dock Leveler Supply, Installation, Testing & Commissioning of following equipments/System Size :- Platform width - 2000 mm Platform length - 2500 mm Lip Length - 400mm Includes :- Dock bumper, Safety devices Description:- 6 ton capacity (point load), Distributed Load 10 Tons Top area by a non-slippery tear plate in 6/8 thickness and structure of cold laminated profiles. 13/15 tear plate swinging lip with milling end and a 5º wrinkle to ease the adaptation to the truck. 1.0 HP Hydraulic Group, 380 V, 50 Hz at 3,000 rpm, with a 5 liter/min flow pump and a 7 liters tank. It includes a security electro valve working at 24V. Deck elevation movement and opening of swinging lip by operation of hydraulic cylinders. Immobilizer security system in the event of emergency stop or power failure.
670Retractable Dock Shelter - With Aluminium Frame Supply, Installation, Testing & Commissioning of following equipments/System Size:- W 3400 mm * H 3400 mm The front sheets are made of high elasticity, wear, and tear-resistant PVC. During loading/unloading a part of the truck body is positioned inside the dock shelter. The top and side sheets cover tightly the truck body and ensure sealing. Operation temperature-35Celsius to70 celcius min. thickness-3 mm
671Wheel Guide For Dock Leveller Supply, Installation, Testing & Commissioning of following equipments/System Hot Dip Galvanised Wheel Stopper (2000mm *160mm dia).
672Supply Installation, Testing and comissioning of 32 Channel Netwrok Video Recorder Embedded OS Linux CPU ARM Processor Flash 256 MB RAM 4 GB Watchdog Hardware + Software Power Restoration System Restart Automatically after Power Recovery HDD Devices Internal x 4 HDD Max. (Total 32 TB HDD required ) Capacity 8 TB x 4 Disk Management Create, Format and Remove Disk HDD S.M.A.R.T Video Output HDMI x 1, VGA x 1 Resolution 1920x1080, 1280x720 Graphics Decoder Hardware decodingH.265/H.264: 2560x1920 @ 30 fps (1-CH) 1920x1080 @ 120 fps (4-CH) 1280x720 @ 240 fps (8-CH) 1280x720 @ 480 fps (16-CH) 720x480 @ 960 fps (32-CH) USB Interface Front: 2 (USB 2.0) Back : 1 (USB 3.0) Alarm In 8 Alarm Out 4 Audio 3.5 Phone Jack Audio Output x 1 3.5 Phone Jack Audio Input (Reserved) x 1 RS485 1 Port (Reserved) Network Interface 10/100/1000Mbps Ethernet (RJ-45) x 2 Protocols IPv4, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, SMTP, FTP, DHCP, NTP, DNS, DDNS, IP Filter Power Safety Certifications CE, LVD, FCC, VCCI, UL Listed, ONVIF Complaint, as per detailed specifications.RAID5 configured Calculated @ H.264 Compression, 25 fps @ 720p, 60 daysx 12 hrs of Motion Based recording. Bidders to Provide Storage Calculations to substantiate the Storage Requirements in the Tender. If a Bidder would require larger storage, the same to be mentioned and included in this line item Make - Vivotek/Axis/Bosch/Dvital
673Supply, Installation, Testing and Commissioning of Fixed Dome 1/2.8" Progressive CMOS2 MP Indoor 1920x1080 VFf = 2.8-6mm, POE. Field of View 109° (Horizontal) 61° (Vertical) 126° (Diagonal) With Built-in IR illuminators, effective up to 30 meters with Smart IR, IR LED*2 SNV Min. Illumination 0.07 Lux @ F1.6 (Color) 0.001 Lux @ F1.6 (B/W) 0 Lux with IR illumination on 3D Noise Reduction. Should have 120 dB WDR MicroSD/SDHC/SDXC card slot Approvals required :CE, LVD, FCC Class B, VCCI, C-Tick, UL, Complete with required accessories, patch cords, convertors, Ajustable stand for mounting the cameras in open office areas, etc. Make - Vivotek/Axis/Bosch/Dvital
674Monitor 32" high perfomance TFT Multi mode LCD, VGA, 2 looping composite, S-video & DVI input, USB Hub,100-230 VAC 50 Hz Make-LG/Samsung
675Supply Installation, Testing and comissioning of 24 port layer 2 switch with 10/100/1000 POE Managed Switches withIP multicast snooping and data-driven IGMP support and with two 1000baseT single mode FO uplink ports and all related termination accessories as per site specific System requirement. Complete with 9u rack Make - Cisco/HP
676Supply Installation, Testing and comissioning of Storage for NVR - 8TB including all components complete with connection and testing as directed.
677Supply Installation, Testing and comissioning of RJ 45 Connectors complete with all components fixing and allied accessories as directed.
678Supply Installation, Testing and comissioning of CAT 6e Network Cable Armoured/ Cat6 flexible in Conduits. Make - Systimax/Tyco/Saflex
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail