}

Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Getalsud Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada, Ranchi-Jharkhand

Water Resources Department-WRD has published Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Getalsud Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada. Submission Date for this Tender is 29-03-2022. Connectors Supply Tenders in Ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31210371
Corrigendum : Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Getalsud Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada
Open Tender
Indian
Jharkhand
Ranchi
29-03-2022

Tender Details

Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Getalsud Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Getalsud Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . , Decription , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 1 Kva Ups For Power Back Up, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification.Getalsud Dam -4 No. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications.Getalsud Dam - 12 No. , Supply Of 3 Phase Vfd Starter Panel For Each Motor Of Dam Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications. Getalsud Dam -10 No. , Supply Of Bullet Camera ( Fixed Type ) - Ip Digital Night Vision ( I.R. ) Outdoor Weather Resistant, 2 Mega Pixel, 72 Led Colour Camera. 6 Or 8 Or 12 Mm ( According To Site Suitability ) 2 Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation Complete As Per Technical Specifications.Getalsud Dam -12 No. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Meters. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Including Cabling Required For Monitoring. As Per Technical Specifications.Getalsud Dam - 2 No. , Supply Of Automated Water Level Transmitter Non-Contact Ultrasonic / Radar Type Having 10M Range For Measuring The Downstream Level / Discharge Of Head Regulators. Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications.Getalsud Dam -1 No. , Supply Of Automated Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications.Getalsud Dam -3 No. , Supply Of 2 Channel Input Type Datalogger / Rtu With Gprs / Gsm Based Telemetry Including Antenna, Enclosure And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications.Getalsud Dam - 2 No. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Remote Monitoring Stations, As Per Technical Specifications.Getalsud Dam - 2 No , Supply Of Solar Power System 10 Kva Which Includes Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Lockable Enclosure , Cabling And All Required Accessories Etc. For Electrification And Illumination Of Dam & Dcr Equipment With Power Back Up Of 36 Hours, Which Includes All Accessories, Cabling Etc. As Per Technical Specifications.Getalsud Dam - 1 No. , Dam Control Room Equipment’S , Supply Of Fabricated Steel Corrugated Sheets For Dam Control Room Of Size 250 Sq. Ft. With Standard Height Comprising Of All Necessary Furniture And Fittings And Air Conditioning System Complete In All Respect As Per Technical Specification For Installation Of All Necessary Control Room Equipment.Getalsud Dam – 01 No. , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Display & Interconnection With Related Remote Plc / Rtu’S, Complete As Per Technical Specification.Getalsud Dam - 1 No. , Supply, Engineering And Development Of Customized Scada Software For Complete Dam And Head Regulator System With Life Time Licensed Version As Per Technical Specifications.Getalsud Dam - 1 No. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications.Getalsud Dam - 2 No. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications.Getalsud Dam - 1 No. , Supply Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Color Printer As Per Technical Specifications.Getalsud Dam - 1 No. , Supply Of 110” Led Display / Video Wall / ( 70”, 2X1 ) Dlp Based System For Monitoring Of Scada & Surveillance System At Dam Control Room As Per Technical Specifications.Getalsud Dam - 1 No. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Dam Control Room Equipment’S Including All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications.Getalsud Dam - 1 No. , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Version Client Scada Software For Remote Viewing & Monitoring Of System As Per Technical Specifications.Getalsud Dam - 1 No. , Local Control System For Dam & Head Regulatorsfor Getalsud Dam , Iinstallation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 1 Kva Ups For Power Back Up, 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification.Getalsud Dam - 4 No. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications.Getalsud Dam - 12 No. , Installation, Testing & Commissioning Of 3 Phase, Vfd Starter Panel For Each Motor Of Dam Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications.Getalsud Dam - 10 No. , Installation, Testing & Commissioning & Integration With Nvr Located At Dam Control Room, Of Bullet Camera ( Fixed Type ) - Ip Digital Night Vision ( I.R. ) Outdoor Weather Resistant, 2 Mega Pixel, 72 Led Colour Camera. 6 Or 8 Or 12 Mm ( According To Site Suitability ) 2 Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66 For Monitoring The Gates Operation, Complete In All Respects As Per Technical Specifications.Getalsud Dam - 12 No. , Installation, Testing & Commissioning & Integration With Nvr Located At Dam Control Room, Ofpan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Meters. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing. Including Cabling Required For Monitoring Of Dam. Complete In All Respects As Per Technical Specifications.Getalsud Dam – 2 No. , Installation, Testing & Commissioning Of Automated Water Level Transmitter Non-Contact Ultrasonic / Radar Type Having 10 M Range For Measuring The Downstream Level / Discharge Of Head Regulators. Including All Necessary Cabling With Suitable Conduits, Electrical Fittings & Mast And Integration With Plc / Rtu Complete As Per Technical Specifications.Getalsud Dam - 1 No. , Installation Testing And Commissioning Of Automated Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications.Getalsud Dam - 3 No. , Installation Testing And Commissioning Of 2 Channel Input Type Datalogger / Rtu With Gprs / Gsm Based Telemetry, Enclosure Including Antenna And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications. Getalsud Dam – 2 No. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Remote Monitoring Stations, As Per Technical Specifications.Getalsud Dam – 2 No. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Remote Monitoring Stations, As Per Technical Specifications. Getalsud Dam – 2 No. , Installation, Testing & Commissioning Of Solar Power System Of 10 Kva Which Includes Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Lockable Enclosure, Cabling And All Required Accessories Etc. For Electrification & Illumination Of Dam & Dcr Equipment’S Complete With 36-Hour Of Minimum Power Back Up. As Per Technical Specifications.Getalsud Dam – 1 No. , Installation, Testing & Commissioning Of Fabricated Office Made Of Steel Corrugated Sheets For Dam Control Room Of Size 250.00 Sq. Ft. With Standard Height Comprising Of All Necessary Furniture And Fittings And Air Conditioning System Complete In All Respect As Per Technical Specifications For Housing All Control Room Equipment.Getalsud Dam – 1 No. , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification.Getalsud Dam – 1 No , Engineering, Testing & Commissioning Of Customized Scada Software For Dam And Canal Head Regulator With Life Time Licensed Version As Per Technical Specifications.Getalsud Dam – 1 No. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, And Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications.Getalsud Dam – 2 No. , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications.Getalsud Dam – 1 No. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications.Getalsud Dam – 1 No. , Installation, Testing & Commissioning 110” Led Display / Video Wall / ( 70”, 2X1 ) Dlp Based System For Monitoring Of Scada & Surveillance System At Dam Control Room As Per Technical Specifications.Getalsud Dam – 1 No. , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years.Getalsud Dam – 1 No , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of System For Five Years.Getalsud Dam – 1 No. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Dam Control Room Equipment’S As Per The Technical Specifications.Getalsud Dam – 1 No. , Five Years Operation & Maintenance And Comprehensive Warranty Forscada Based System For Dam & Head Regulators As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges. Minimum One Service Engineer Shall Be Placed At Dam Control Room For Operation Of Scada & Surveillance System.Service Engineer Atgetalsud Dam. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2022 Corrigendum Upload for pribid clarification Other 24-03-2022
2 16-Mar-2022 Extension of bid submission Date 29-03-2022

Key Value

Document Fees
INR 10000 /-
EMD
INR 50000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail