}

Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Tenughat Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada, tenughat-Jharkhand

Water Resources Department-WRD has published Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Tenughat Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada. Submission Date for this Tender is 29-03-2022. Connectors Supply Tenders in tenughat Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31210359
Corrigendum : Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Tenughat Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada
Open Tender
Indian
Jharkhand
tenughat
29-03-2022

Tender Details

Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Tenughat Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . Supply, Installation, Testing, Commissioning, Operation And Maintenance Of Scada System For Tenughat Dam, Wrd, Jharkhand Under National Hydrology Project ( Nhp ) . , Decription , Supply Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 1 Kva Ups For Power Back Up, 7” Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification.Tenughatdam – 7 No. , Supply Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications.Tenughatdam – 22 No. , Supply Of 3 Phase Vfd Starter Panel For Each Motor Of Dam Gates Which Shall Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications.Tenughatdam – 22 No. , Supply Of Bullet Camera ( Fixed Type ) - Ip Digital Night Vision ( I.R. ) Outdoor Weather Resistant, 2 Mega Pixel, 72 Led Colour Camera. 6 Or 8 Or 12 Mm ( According To Site Suitability ) 2 Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66, For Monitoring The Gates Operation Complete As Per Technical Specifications. Tenughatdam – 22 No. , Supply Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Meters. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing Including Cabling & Mounting Accessories. As Per Technical Specifications.Tenughatdam – 2 No. , Supply Of Automated Water Level Transmitter Non-Contact Ultrasonic / Radar Type Having 10M Range For Measuring The Downstream Level / Discharge Of Head Regulators. Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications.Tenughatdam – 2 No. , Supply Of Automated Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Of Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits & Electrical Fittings & Mast Complete As Per Technical Specifications.Tenughatdam – 3 No. , Supply Of Datalogger / Rtu With 2 Channel Input Type Gprs & Gsm Based Telemetry Including Antenna, Enclosure And All Necessary Equipment For Data Transmission For Remote Monitoring Stations, As Per Technical Specifications.Tenughatdam – 2 No. , Supply Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduit For Cables For Providing Un Interrupted Power Supply To Remote Monitoring Stations, As Per Technical Specifications.Tenughatdam – 2 No. , Supply Of Solar Power System 10 Kva Which Includes Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Lockable Enclosure With Locking, Cabling And All Required Accessories Etc. For Electrification And Illumination Of Dam & Dcr Equipment With Power Back Up Of 36 Hours, Which Includes All Accessories, Cabling Etc. As Per Technical Specifications.Tenughatdam – 1 No. , Dam Control Room Equipment’S , Supply Of Air Conditioning System With Requisite Furniture, Renovation & Furnishing Of Existing Dam Control Room For Establishment Of Scada Control Room Long With Necessary Electrical Fittings As Per Technical Specification.Tenughatdam – 1 No. , Supply Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem. All The Electrical Fittings Will Be Industrial Type. Including Suitable Switch Mode Power Supply ( Smps ) , 12” Display & Interconnection With Related Remote Plc / Rtu’S, Complete As Per Technical Specification.Tenughatdam – 1 No. , Supply, Engineering And Development Of Customized Scada Software For Complete Dam And Head Regulator System With Life Time Licensed Version As Per Technical Specifications.Tenughatdam – 1 No. , Supply Of Master Server Which Includes Server With Server Rack And Industrial Grade Monitor With Usb, Rs232 / Rs485, Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications.Tenughatdam – 2 No. , Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format With Dedicated Sufficient Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications.Tenughatdam – 1 No. , Supply Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Color Printer As Per Technical Specifications.Tenughatdam – 1 No. , Supply Of 110” Led Display / Video Wall / ( 70”, 2X1 ) Dlp Based System For Monitoring Of Scada & Surveillance System At Dam Control Room As Per Technical Specifications.Tenughatdam – 1 No. , Supply Of Online 3 Kva Ups With Battery System For Power Back Up Of Dam Control Roomincluding All Necessary Cabling & Electrical Fittings Complete As Per The Technical Specifications.Tenughatdam – 1 No. , Supply Of Laptops & 4G / 3G Internet Dongle Along With Licenced Version Client Scada Software For Remote Viewing & Monitoring Of System As Per Technical Specifications.Tenughatdam – 1 No. , Local Control System& Head Regulators For Tenughat Dam , Installation, Testing & Commissioning Of Plc / Rtu System With Software Development Of Plc / Rtu, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Suitable Power Supply To Power Up Plc / Rtu Panel, Including 1 Kva Ups For Power Back Up, 7 Inches Or Above Hmi Display & Industrial Type Electrical Fitting & Cabling With Suitable Conduits Complete For All Related Field Instruments, As Per Technical Specification.Tenughatdam – 7 No. , Installation, Testing & Commissioning Of Shaft Encoder Based Rotary Position Sensor With Local Digital Display & Proximity Limit Switches Type Gate Position Sensors For Indication And Monitoring Of Spillway Gates, Intake Gates, Silt Flushing Gates Including Cabling & Integration With Plc / Rtu As Per Technical Specifications.Tenughatdam – 22 No. , Installation, Testing & Commissioning Of 3 Phase, Vfd Starter Panel For Each Motor Of Dam Gates Which Consists Of Vfd, S.P.P, Mcb, Olr, Timer, Main Switches Including Cabling & Electronic Digital Indicator Complete As Per Technical Specifications.Tenughatdam – 22 No. , Installation, Testing & Commissioning & Integration With Nvr Located At Dam Control Room, Of Bullet Camera ( Fixed Type ) - Ip Digital Night Vision ( I.R. ) Outdoor Weather Resistant, 2 Mega Pixel, 72 Led Colour Camera. 6 Or 8 Or 12 Mm ( According To Site Suitability ) 2 Mp Auto Iris Lens In Elegant Metal Die Cast Housing. Outdoor Weather Resistant Ip 66 For Monitoring The Gates Operation, Complete In All Respects As Per Technical Specifications.Tenughatdam – 22 No. , Installation, Testing & Commissioning & Integration With Nvr Located At Dam Control Room, Of Pan Tilt Zoom ( Ptz ) 36 X Optical And 12 X Digital Zoom; 2 Mega Pixel Ip Based ( Digital ) Camera, 500 Meters. Night Vision ( Multiple Intelligent Array System ) In Ip66 Weather Resistant Outdoor Metallic Housing Including Cabling & Mounting Accessories . As Per Technical Specifications. Tenughatdam – 2 No. , Installation, Testing & Commissioning Of Automated Water Level Transmitter Non-Contact Ultrasonic / Radar Type Having 10 M Range For Measuring The Downstream Level / Discharge Of Head Regulators. Including All Necessary Cabling With Suitable Conduits, Electrical Fittings , Mast And Integration With Plc / Rtu Complete As Per Technical Specifications. Tenughatdam – 2 No. , Installation Testing And Commissioning Of Automated Water Level Transmitter Non-Contact Radar Type Having 35M Range For Measurement Of Level / Discharge At Remote Monitoring Stations, Including All Necessary Cabling With Suitable Conduits , Electrical Fittings & Mast Complete As Per Technical Specifications.Tenughatdam – 3 No. , Installation Testing And Commissioning Of Datalogger / Rtu With 2 Channel Input Type Gprs / Gsm Based Telemetry, With Enclosure Including Antenna And All Necessary Equipment For Data Transmission Of Remote Monitoring Stations, As Per Technical Specifications.Tenughatdam – 2 No. , Installation Testing And Commissioning Of Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Cables And Conduits, For Providing Un Interrupted Power Supply To Remote Monitoring Stations, As Per Technical Specifications.Tenughatdam – 2 No. , Installation Of Chain-Link Fencing Of ( 5M X 5M ) X 3M Along With Lockable Gates For External Protection Of Remote Monitoring Stations, As Per Technical Specifications.Tenughatdam – 2 No. , Installation, Testing & Commissioning Of Solar Power System Of 10 Kva Which Includes Solar Panel, Charger Regulator, Batteries, Lightening Arrestor With All Connectors, Lockable Enclosure, Cabling And All Required Accessories Etc. For Electrification & Illumination Of Dam & Dcr Equipment’S Complete With 36-Hour Of Minimum Power Back Up. As Per Technical Specifications.Tenughatdam – 1 No. , Installation, Testing & Commissioning Of Air Conditioning System With Necessary Electrical Fittings Complete In All Respect As Per Technical Specifications. Tenughatdam – 1 No. , Installation, Testing & Commissioning Of Main Plc Controller System With Firm Ware Based Hot Redundancy Which Shall Include Software Development Of Plc, Control Panel With Front Door Opening Cabinet, Fitted With Power Buses, Mcbs & Modem.Including Suitable Switch Mode Power Supply ( Smps ) , 12” Display & Cabling With Industrial Grade Type Electrical Fittings For Related Remote Plc / Rtu’S, As Per Technical Specification.Tenughatdam – 1 No. , Engineering, Testing & Commissioning Of Customized Scada Software For Dam And Canal Head Regulator With Life Time Licensed Version As Per Technical Specifications. Tenughatdam – 1 No. , Installation, Testing & Commissioning Of Master Server With Scada Software Which Includes Server With Server Rack And Industrial Grade Pc With Usb, Rs232 / Rs485, And Ethernet Ports, Os Windows 8 Or Higher Compatible To Scada System Complete As Per Technical Specifications.Tenughatdam – 2 No. , Installation, Testing & Commissioning Of Network Video Recorder ( Nvr ) 32 Channel 1080 P Full Hd, Real Time Recording And Reviewing In Compression Format. With Hdd Along With Dedicated Hard Drive To Have Memory Of At Least 30 Days As Per Technical Specifications.Tenughatdam – 1 No. , Installation, Testing & Commissioning Of It Hardware Which Includes Required Static Ip, Router, Switch, Firewall System And A3 Colour Printer As Per Technical Specifications.Tenughatdam – 1 No. , Installation, Testing & Commissioning 110” Led Display / Video Wall / ( 70”, 2X1 ) Dlp Based System For Monitoring Of Scada & Surveillance System At Dam Control Room As Per Technical Specifications.Tenughatdam – 1 No. , Charges For High Speed Synchronous Internet Connection ( Min. 8 Mbps Upload And Download Speed ) & Static Ip For Five Years.Tenughatdam – 1 No. , Charges For High Speed 4G / 3G Internet Dongle For Laptop With Client Scada Software For Remote Viewing & Monitoring Of System For Five Years.Tenughatdam – 1 No. , Installation, Testing & Commissioning Of Online 3 Kva Ups With Battery System For Power Back Up Of Dam Control Room Equipment’S As Per The Technical Specifications.Tenughatdam – 1 No. , Five Years Operation & Maintenance And Comprehensive Warranty For Specified Dam & Head Regulators Scada Based System As Per Price Schedule After Final Acceptance Of Scada & Surveillance System. This Includes Replacement Of Material & Consumable As & When Required At Bidders’ Cost. The Cost Of Communication For Gprs & Sim Charges For Data Transmission, Maintenance And Other Related Charges.Minimum One Service Engineer Shall Be Placed Atdam Control Room For Operation Of Scada & Surveillance System.Service Engineer Attenughatdam – 1 No. , Training Of The Purchasers Personnel At The Supplier’S Plant And / Or / Onsite In Assembly, Start Up, Operation, Maintenance And / Or Repair Of The Supplied Goods. Course Topics Will Include Sensor Calibration, Plc / Rtu & Scada Configuration, Data Downloading, Data Retrieval, Collection, Trouble Shooting, Processing Maintenance Requirements And Procedure For Equipment Configuration, Installation, Site Testing And Commissioning Including Training Kit Containing Course Material In Soft And Hard Copies.Tenughat Dam- 8 Training

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2022 Corrigendum Upload for pribid clarification Other 24-03-2022
2 16-Mar-2022 Extension of bid submission Date 29-03-2022

Key Value

Document Fees
INR 10000 /-
EMD
INR 620000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail