Providing Sewerage Facilities In Village Bhiduki, District Palwal Under Nabard Design, Construction, Supply, Erection, Testing Commissioning Of 2.50 Mld Mps Comprising Of Receiving Chamber, Mechanical Coarse Screen, Raw Effluent Sump Cum Pump House, Pumpi, palwal-Haryana

Public Health Engineering Department-PHED has published Providing Sewerage Facilities In Village Bhiduki, District Palwal Under Nabard Design, Construction, Supply, Erection, Testing Commissioning Of 2.50 Mld Mps Comprising Of Receiving Chamber, Mechanical Coarse Screen, Raw Effluent Sump Cum Pump House, Pumpi. Submission Date for this Tender is 04-03-2022. Pumping Machiney Tenders in palwal Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

31200112
Providing Sewerage Facilities In Village Bhiduki, District Palwal Under Nabard Design, Construction, Supply, Erection, Testing Commissioning Of 2.50 Mld Mps Comprising Of Receiving Chamber, Mechanical Coarse Screen, Raw Effluent Sump Cum Pump House, Pumpi
Open Tender
Indian
Haryana
palwal
04-03-2022

Tender Details

Providing Sewerage Facilities In Village Bhiduki, District Palwal Under Nabard Design, Construction, Supply, Erection, Testing Commissioning Of 2.50 Mld Mps Comprising Of Receiving Chamber, Mechanical Coarse Screen, Raw Effluent Sump Cum Pump House, Pumping Machinery, Mechanical Fine Screens, Detritus Chamber, 2.50 Mld St

Key Value

Document Fees
INR 15000 /-
EMD
INR 913300.0 /-
Tender Value
INR 4.56 Crore /-

BOQ Items

Name of Work:- Providing Sewerage facilities in village Bhiduki, District Palwal under NABARD, “Design, Construction, Supply, Erection, Testing & Commissioning of 2.50 MLD MPS Comprising of Receiving Chamber, Mechanical Coarse Screen, Raw Effluent Sump cum Pump House, Pumping Machinery,Mechanical Fine Screens, Detritus Chamber,2.50 MLD STP based onSBR Technology, SBRBasin Sludge Sump, Sludge Lifting Pump, Centrifuge, HT/LT Panel Room, Utility Building, Chlorine Contact Tank, Chlorinator, Boundary Wall, Staff Quarter, PLC, SCADA, CCTV Cameras, Transformer, D.G. Set and all other works contingent theretoincluding Operation & MaintenanceforFive year after One year Defect Liability Periodafter 3 month trial run period for village Bhiduki Distt. Palwal . Amt. Rs. 456.65 Lakh
Sl. No. Item Description
1A1 MAIN PUMPING STATIONS Design, construction, erection, testing & commissioning of MPS and following components including O&M for 5 years after 1 year defect liability period after 3 months trial run period.Panel room of 30 sqm. covered area and PLC room including toilet block of 20 Sq mtr. covered area with RCC framed structure of brick work vitrified glazed tiles flooring, Powder coated aluminum frame of size 100mm x 45mm of 10 gauge for chowkhat, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glassAIS/Saint Gobin/Modi Float, The toilet block shell be with one half staff urinal & One European W/C, one wash hand basin as per approved drawings RCC Inlet chamber, Screen Chamber, rectangular collecting tank suitable for 2.50 MLD average flow with peak factor of complete in all respectK9 DI pipe of suitable dia at MPS Including welding and screwing of flanges, ISI marked D.I. fittings, Sluice valve, non return valves as per requirements even for bye-pass arrangements complete in all respect 3 nos. CI Gear Operated Sluice Gate with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design Supply installation of 2 nos. mechanical course screens of minimum length 6 mtrs. for 2.50 MLD average flow with peak factor of 3.0 Note:- 1. The connecting sewer of same diameter andmaterial of construction, laid at adequate depth between existing sewers to newly constructed structures is includedin scope of work. 2. All the infrastructure except construction of staff quarter, and path ways/ roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job. 3. All the pumping machinery, panel board, Level sensor etc shall be controlled by PLC & SCADA and shall be synchronized with PLC panels at MPS & STP site through broadband internet facility. 4. The size and quantities of all the above components will be as per approved structural /Hydraulic /Mechanical /Electric design to be approved by Department before actual execution of work including O&M of 5 Years after 12 months defect liability period after 3 months trailrun period
2A2- SEWAGE TREATMENT PLANT Design, construction, erection, testing & commissioning of 2.50 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping MCC Panel room & all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device, Real Time Water Quality Monitoring with Data Collection System(Online analyzer), Piping & Instrumentation works. With PLC & SCADA Arrangement for STP & MPS along with Synchronizing it with each other including furniture & laboratory equipments as per detail given in the bid document and including following components including O&M of 5 Years after 12 months defect liability period after 3 months trail run period. 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED energy outdoor suitable size reputed make efficient lamps on each pole, including 20 no. LED outdoor lights with GI poles 7 mtr high including all accessories along the road and path complete in all respect. Supply and installation of 1 No. Main Gate of (MS)12 ft. wide main gate and 4 ft. wide wicket gate (total weight not less than 500 kg) at STP site. as per satisfaction of Engineer-in-charge. Providing and installing 2 No. centrifuges (1Working + 1 Stand bye) including centrifuge feed pump, all fittings, instrumentations, electric panel board etc. as per design complete in all respect of the NIT, including packing dry sludge in 20Kg Bag and supplying the same Market Kisan Sewa Kendra or as directed by Engineer-in-charge within lead as posited as clauge 4.4.5 of NIT including operation and maintenance of 5 Years after 12 months defect liability period after 3 months trail run period. Providing and installation of 2 nos. pumping sets of suitable size (1 working and 1 standby) with head 15 mtrs. in chlorination tank to disposed off the treated effluent including all fittings, instrumentations, electric panel board etc. as per design complete in all respect including operation and maintenance of 5 Years after 12 months defect liability period after 3 months trail run period. Supply, Installation, Testing, Commissioning, operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 2.50 MLD STP at Village Bhiduki for Online (Continuous) measuring of PH, total Suspended Solids (TSS) Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cable, local data acquisition and display the data of continuous basis for up linking the data of CPCB, HSPCB & PHED, TUV Board approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work in the notice inviting tender:Multi-parameter measuring converter, for connecting up to 18 intelligent seniors Scope including 8 analog inputs/Outputs(4 Inputs & 4 outputs) (o/4-20Ma), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV-VIS range for measurement plant of 2.50 MLDSTP at Village Bhiduki with integrated with automatic cleaning.Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier & temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum).Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to intelligent sensors net system cable length 100 Meter (Minimum).Data Transfer to CPCB, HSPCB & PHED Servers during 1 year of O&M after commissioning after 3 months trail period (after 1 year of defect liability period)Providing GSM 3G, 4G Modem with mobile network connectivity including network charges for 5 year of O&M after commissioning after 3 Months trail run (after 1 year defect liability period)
3A3 CCTV CAMERAS Providing and Installing 6 CCTV Cameras 4 Cameras for STP and 2 Cameras for MPS) complete as per satisfaction of the Engineer-in-Charge, within 96 hours of signing the Agreement along with 90 days recording (DVR), 32 inch LED Screen, 16 Channel DVR at STP Site and 8 Channel DVR at MPS Site with connectors, cables, poles and power supply with online real-time output facility. The cameras at both the sites i.e. MPS and STP shall be synchronized at STP site. i) At STP & MPS Site- 1 No. PTZ speed dome 360 degree 50X zoom camera, 3 No. 12mm lens size, 1 Nos. 3.6mm lens size. Make: - CP Plus Internet Protocol minimum 5MP WDR, Night vision colour mode 2.4.2 12mm very focal with extra IR, CCTV Cameras should be installed and commissioned before starting execution of work including operation & Maintenance of 5 Years. after 12 months defect liability period after 3 months trailrun period.
4A4 Construction of HT / LT Panel room, PLC room, Centrifuge house, blower room and Lab cum office building including doors, window and fitting with toilet block including sanitary fittings etc. as per drawing attached in DNIT at MPS & STP site covered area with RCC framed structure of brick work vitrified glaze tiles flooring, powder coated aluminum frame of size 100mm x 45mm of 10 gauge for chowkhat frame, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glassAIS/Saint Gobin/Modi Float, covered area 400 sqm. O&M of 5 Years after 12 months defect liability period after 3 months trailrun period.
Disclaimer :