Repair To Summer Appliances Under Ge ( North ) Patiala Repair To Summer Appliances Under Ge ( North ) Patiala, Patiala-Punjab

Military Engineer Services-MES has published Repair To Summer Appliances Under Ge ( North ) Patiala Repair To Summer Appliances Under Ge ( North ) Patiala. Submission Date for this Tender is 21-03-2022. Air Conditioner Tenders in Patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

31177257
Corrigendum : Repair To Summer Appliances Under Ge ( North ) Patiala Repair To Summer Appliances Under Ge ( North ) Patiala
Open Tender
Indian
Punjab
Patiala
21-03-2022

Tender Details

Repair To Summer Appliances Under Ge ( North ) Patiala Repair To Summer Appliances Under Ge ( North ) Patiala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO SUMMER APPLIANCES UNDER GE(NORTH) PATIALA.
Sl. No. Item Description
1Dismantling and lowering to ground for repair, inspecting defective of Window/Splittype AC of capacity 1.5 and 2 Tonand re-installing the same after repair complete, testing and shifting to new locations if required as specified by Engr-in-Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days.3. Decision of Engineer-in Charge will be final in case of fine payment
2Supply and replacement of compressor sealed unit suitable for Window TypeACs 1.5 Ton Capacity , reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as specified and directed. Make- Kirloskar/ Godrej/Tecumseh/LG
3Supply and replacement of compressor sealed unit suitable for Window TypeACs 1.5 Ton Capacity , Rotarytypeflushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as specified and directed. Make- Kirloskar/ Godrej/Tecumseh
4Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacityreciprocating typeflushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as specified and directed. Make- Kirloskar/ Godrej/Tecumseh
5Supply and replacement of compressor sealed unit suitable for Split Type ACs 1.5 Ton Capacity, rotarytypeflushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as specified and directed. Make- Kirloskar/ Godrej/Tecumseh
6Supply and replacement of compressor sealed unit suitable forACs 2 Ton Capacity ,reciprocating type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as specified and directed. Make- Kirloskar/ Godrej/Tecumseh
7Supply and replacement of compressor sealed unit suitable forACs 2 Ton Capacity ,rotary type flushing , vacuumising and hydration the system, leakage testing , welding/soldering as required and charging refrigerant gas, reinstalling in position and testing for the desired condition includingreplacement of strainer complete all as specified and directed. Make- Kirloskar/ Godrej/Tecumseh
8Material and labour forcharging of gas in window type AC 1.5/2 Ton ( R-22/ R410A)after flushing, vaccumising and dehydration as per laid down standard practice and existing model including replacement of strainer complete all as specified and directed.
9Material and labour forcharging of gas in split type AC 1.5/2 Ton ( R-22/ R410A)after flushing, vaccumising and dehydration as per laid down standard practice and existing modelincluding replacement of strainer complete all as specified and directed.
10Servicing of Air conditioners of window/ split type of any capacity by removing dirt and debries on all parts of air conditioner, washing and lubricating all moving parts complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. Note :1.Lowering, dismantling, re-installing of air conditioners after reassembling the equipment in same/different position shall be included in the unit quoted rate.2. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 3. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days.4. Decision of Engineer-in Chargewill be final in case of fine payment
11Supply and replacement of double shaft blower motor of size 1/10 HP for window Air Conditioner of capacity 1.5 Ton single phase 230 V, 1500 rpm complete all specified and directed. Make- Crompton/Kirlosker suitable for AC of make fedder Lloyd/ Blue Star/ LG/ Carrier/Samsung
12Supply and replacement of indoor/blower motor of size 1/10 HP for split Air Conditioner of capacity 1.5 Ton as per existing model of approved make complete all specified and directed.
13Supply and replacement of Fan motor for split typeAir Conditioner of capacity 1.5/2.0 Ton as per existing model complete all specified and directed. Make Voltas/LG/Samsung.
14M&L for rewinding of blower motor double speed (high & low) with supper enamelled copper wire of proper gauge with and including rubber bush of capacity1/10 HP motor complete all specified and directed.
15Supply and fix Rolling type PVC Blower for indoor unit of split AC 1.5 / 2.0 Ton Capacity Make as per existing.
16Supply and fix Fan Blade for out door unit of split AC 1.5 /2.0 Ton Capacity make as per Existing
17Supply and fix as in replacement flexible copperconductor cable 3 core, PVC insulated of size70/.0076 and connected electrically to any electric devices/ofanycapacity sizetype & make etc complete all as specified and directed. Make:KEI,Plaza,Kalinga,Havells
18Supply and Replacement of capacitor 6 mfd 230volts (+) 5% dry type complete suitable for window /split Ac motorsas specified and directed. Make Tibcon/Elcap or equivalent
19Supply and replacement of running capacitor 36 mfd complete all specified and directed. Make-TIBCON/SIEMENS or equivalent.
20Supply and replacement of running capacitor 45/50 mfd complete all specified and directed. Make-TIBCON/SIEMENS or equivalent.
21Supply and replacement of starting capacitor of size 100-120 MFD for Air Conditioner up to 2 Ton Capacity complete all specified and directed. Make-TIBCON/SIEMENS or equivalent.
22Supply and replacement of starting capacitor of size 80-100 mfd complete all specified and directed. Make-TIBCON/SIEMENS or equivalent.
23Supply and replacement of box type relay type Model Sr-1622 for Air Conditioner 1.5 Ton/2 Ton capacity as per sample approved by department complete all specified and directed. Make- MICROTECH/ HITECH .
24Supply and replacement of PCB assemblyof existing make for ACs 1.5 to 2.0 ton window type ACs with remote control complete all specified and directed.
25Supply and replacement of PCB assemblyof existing make for ACs 1.5 to 2.0 ton split type Acs with remote control complete all specified and directed.
26Repair of PCB assembly of existing make for invertor AC complete all specified and directed.
27Supply and fix indoor motor of Invertor AC of existing make complete all specified and directed.
28Supply and replacement of fan blade of window ACs of cap 1.5 to 2.0 ton complete all specified and directed.
29Dismantling and lowering to ground for descaling of condenser with appropiate chemical towindow/split typeAcsof capacity 1.5 and 2 Tonand re-installing the same it original positiontestingcomplete all specified and directed.
30Supply and fix PVC enclosures, single pole and neutral with a two pin and earth plug and socketed complete with one single pole MCB,s capacity 32 Amp /40 Amp 240Volts complete all specified and directed.
31Supply only Thermostat switch 2059/2064/2054 for Window / Split type AC unit of cap 1.5 ton/ 2 ton complete all specified and directed. Make: Indfos
32Supply only Copper filter double capillary pencil type for window/split type AC of cap 1.5 ton/ 2 ton complete all specified and directed.
33Supply only wiring kit for AC window/Split type 1.5/2 Ton complete all specified and directed.
34Supply only remote control hand set for existing Window type/ split type air conditioner of make LG/Samsung/Voltas/Bluestar and of cap 1.5/2 ton with requred pencil cells as per sample complete all as specified and directed.
35Supply only AC contactor single phase 230 Volt, 50 Hz, double pole, AC3 rating 25 Amp/32 Amp complete all specified and directed.
36Supply only air filter made of Ric/ Nylon suitable for split/ window type AC 1.5/2 TR cap complete all as specified and as directed . Make: Samsung/LG/Voltas/carrier.
37Supply and replacement PVCpipe flexible type 20mm dia (including flexible clamps) for drain out waste water from split Acs complete all as specified and as directed .
38Carrying out pressure leak test for 1.5/2 ton capacity window/split type AC by Nitrogen gas pressure for detecting the leakage in condensing & cooling unit, referigerant pipe and repairing the leakage by welding or brazing, checking the leakage after repairing, flushing out nitrogen gas, vaccumisation complete all as specified and directed.
39Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 1.5 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitor, relay condensing/ outdoor motor with blade complete all as specified and as directed. Make :- Opel/ Accent/ Skoda/ LG/ Carrier
40Supply and fix in renewal defective indoor unit of 1.5 TR capacity split type AC (Make: Omega/ ITC/ Totaline) with blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed. Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately.
41Dismantling and lowering to ground for repairs inspecting defects of water coolers of capacity 40/120/150 litres with cleaning, oiling greasing of all required parts etc and re-installing the same after repair and testing to the complete satisfaction of Engineer -in - Charge. Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days.3. Decision of Engineer-in Charge will be final in case of fine payment
42Supply and replacement of compressor sealed unit forwater cooler of size 40/80 litre including refixing the unit , supplying and charging gas after satisfactory leak testing including welding/soldering as required and commissioning complete all as specified and as directed. Make - Kirloskar/ Godrej/ Blue Star/Tecumseh
43Supply and replacement of compressor sealed unit forwater cooler of size 120 and 150 litre including refixing the unit , supplying and charging gas after satisfactory leak testing including welding/soldering as required and commissioning complete all as specified and as directed. Make - Kirloskar/ Godrej/ Blue Star/Tecumseh
44Material and labour for gas charging ( Freon-22/R134-a) to the water coolers of capacity 40/80 litres after satisfactory vacuum and pressure including replacement of strainer & testing complete all as specified and as directed.
45Material and labour for gas charging ( Freon-22/R134-a) to the water coolers of capacity 120/150 litres after satisfactory vacuum and pressure including replacement of strainer & testing all as directed.
46Supply and fixing of push cock 15 mm CP size for water coolers as per existing shape and size complete all as specified and as directed. Make-KK/EKTA.
47Supply and replacement offan motor of condenser size 1/35 HP complete with blade and connectingcomplete all as specified and as directed. Make:FRAC MASTER/AIR MASTER
48Supply and replacement offan motor of condenser size 1/10HP complete with blade and connectingcomplete all as specified and as directed. Make:FRAC MASTER/AIR MASTER
49Supply and replacement of relay for water cooler with OLP complete all as specified and as directed. Make MICROTECH/HITECH
50Supply and replacement of relay of No. 4445 with OLP complete all as specified and as directed.
51Supply and replacement of running capacitor 10 mfd complete all as specified and as directed. (Make-TIBCON/SIEMENS)
52Supply and replacement of running capacitor 15 mfd complete all as specified and as directed. (Make-TIBCON/SIEMENS)
53Supply and replacement of running capacitor 36mfd complete all as specified and as directed. (Make-TIBCON/SIEMENS)
54Supply and replacement of PVC float Valve suitable for 15 mm bore pipe (ISI marked) complete suitable for water coolers/desert coolersas per existing at site complete all as specified and as directed.
55Supply and replacement of thermostat switch of water cooler complete all as specified and as directed.(Make- DASSPASS/ INDFOSS)
56Supply and replacement of starting capacitor 40/60 mfd 230 volts complete all as specified and as directed. (Make- TIBCON /SIEMENS)
57M & L in replacement of condenser coil fin type as per existing size and pattern for water coolers 60/120 Ltrs capacity complete all specified and directed.
58All as per item 57 here in above but for water cooler of capacity 40 litre complete all specified and directed.
59Cutting the rusted unserviceable base of 120/40 litre capacity, water cooler body, material and labour for fabrication of new base made of MS sheet and angle iron as per existing size and thickness incl welding of small patches complete all specified and directed.
60Dismantling the evaporator/ cooling coil of water cooler capacity 120/40 litres, checking the leakages of gas and rectify by gas welding or as in other means complete all specified and directed.
61Supply and fixing in replacement of complete top door made out of stainless steel 20 gauge sheet with handle and locking arrangement with double keys including door gasket, insulating material, PVC inner sheet of suitable thickness for 120/40 ltrs capacity water cooler as per existing size and shape, welding work, nuts, bolts and washers complete all specified and directed.
62Supply and fix in replacement of 900mm long PVC connections 15mm dia bore with PTMT nuts complete all as specified and directed.
63Disconnecting and complete opening of voltage stabilizer of capacity up to 5KVAand removing the burnt out unserviceable parts and cleaning complete all as specified and directed.
64Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assy of voltage stabilizer s of capacity up to 2 KVA complete all as specified and directed.
65Rewinding with copper enamelled wire as per existing gauge complete all as directed of transformer assy of voltage stabilizers of capacity of3 to 5KVA complete all as specified and directed.
66Supply and replacement of boost/buck relay of voltage stabilizer of capacity up to 2 KVA complete all as specified and directed.
67Supply and replacement of boost/buck relay of voltage stabilizer of capacity up to 3 to 5 KVA complete all as specified and directed.
68Supply and replacement of cut out relay of suitable for up to 2 KVA complete all as specified and directed.
69Supply and replacement of cut out relay of suitable for 3 to 5 KVA complete all as specified and directed.
70Supply and replacement of Volt meter for voltage stabilizer suitable for 3 to 5 KVA complete all as specified and directed.
71Supply and replacement ofcopper pipe heavy duty of size 5/8" complete all as specified and directed.
72Supply and replacement ofcopper pipe heavy duty of size 3/8" complete all as specified and directed.
73Supply and fixing pipe insulation for copper pipe of size 5/8" and 3/8" complete all as specified and directed.
74Supply and replacement ofPVC Hose Pipe flexible type with clamp 25mm dia for ( including flexible clamps)drain out waste water from water cooler complete all as specified and directed.
75S&F Top Plug3 Pin 5 Amps 230 Volts complete all as specified and directed. Make: Anchor/Plaza.
76S&F Top Plug3 Pin 15 Amps 230 Volts complete all as specified and directed. Make: Anchor/Plaza.
77Supply and replacement of compressor sealed unit for refrigerator of size 165 to 220Ltr cap with and including supplying and charging of gas and including welding/soldering for leak proof as required and commissioning complete all as specified and directed. Make Kirloskar/Tecumseh/LG/Godrej/Whirlpool.
78Supply and replacement of compressor sealed unit for refrigerator of size 270 to 310 Ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed. Make Kirloskar/Tecumseh.
79Supply and replacement of compressor sealed unit for deep freezer of size 220 litr/ 320 ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed. Make Kirloskar/Tecumseh.
80Supply and replacement of startingbox type relay PVC 1/8 HP suitable for any make Refrigerator of size 165 to 310 Lts complete all as specified and directed. (Make TIBCON/SIEMENS)
81Supply and replacement of startingbox type relay PVC 1/6 HP for Refrigerator of size310 Lts complete all as specified and directed. (Make TIBCON/SIEMENS/HITECH)
82Supply and replacement of over load protector 1/6 HP for Refrigerator of size 310 Lts complete all as specified and directed. (Make TIBCON/SIEMENS/HITECH)
83Supply and replacement of PCB assemblyof existing make for referigerator of capacity 190 Ltr as per existing make complete all as specified and directed.
84Supply and replacement of PCB assemblyof existing make for referigerator of capacity 310 Ltr as per existing make complete all as specified and directed.
85Supply and replacement of PTC relay ofRefrigerator of 286/ 310 Lts complete all as specified and directed. (Make Godrej /Whirlpool)
86Supply and replacement ofrefrigerantgas in the refrigerator & Deep Freezerincluding satisfactoryleak proofand vacuum test of capacity 286 to 310 ltr including replacement of strainer complete all as specified and directed.
87Supply and replacement ofrefrigerantgasin the refrigerator & Deep Freezerincluding satisfactoryleak proofand vacuum test of capacity 165 to 220 ltr including replacement of strainer complete all as specified and directed.
88Supply and replacement ofFreezer with door frame of refrigerator capacity 165 to 220 ltrs complete all as specified and directed.
89Supply and replacement ofFreezer with door frame of refrigerator capacity 286 to 310 ltrs complete all as specified and directed.
90Supply and replacement of condenser of refrigerator suitable for 286 to 310ltrs of existing make complete all as specified and directed.
91Supply and replacement of condenser of refrigerator suitable for 165to 220ltrs of existing make complete all as specified and directed.
92Supply and replacement of door gasketsof refrigerator capacity 165 to 310 ltrs of existing make complete all as specified and directed.
93Supply and fixing Timer for Refrigerator of Cap 286 to 310 Lts complete all as specified and directed.
94Supply and replacement of fan motor of freezer of refrigerator 286 to 310 lts complete all as specified and directed.
95Supply and laying tube medium grade galavinized 15mm bore including all fittings laid in trenches/fixed with wall /in flooring all as specified and directed. Make : Jindal/Ravindra/TATA
96Supply and replacement of fan motor of deep freezer 220 & 320 lts complete all as specified and directed.
97Supply and fix door gasket suitable for 220/320 ltr deep freezer doors complete all as specified and directed
98Supply and fix starting relay ISI marked for Deep freezer of capacity 220/320 ltr complete all as specified and directed
99Supply and fix OLP ISI marked forDeep freezer of capacity 220/320 ltr complete all as specified and directed
100Supply and fix thermostat ISI marked for deep freezer of capacity 220/320 ltr complete all as specified and as directed
101Supply only starting capacitor 60-80 mfd ISI marked for deep freezer of capacity 220/320 Ltr complete all as specified and directed. Make: Asian/Sharda/unistar/tesla/epcos.
102Supply only running capacitor 36 mfd ISI marked for deep freezer of capacity 220/320 Ltr complete all as specified and directed. Make: Asian/Sharda/unistar/tesla/epcos.
103Supply and replacement of compressor sealed unit for Deep Freezer of 220/320 Ltr cap with and including supplying and charging of gas and including brazing for leak proof as required and commissioning complete all as specified and directed Make Kirloskar/Tecumseh.
104Supply and fix in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pippe 15 mm dia bore including complete all as specified by and directed.
105Servicing of Water purifier of any description complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. (Unserviceable spares shall be measured and paid separately) :- Note: 1. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints. 2. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days.3. Decision of Engineer-in Charge will be final in case of fine payment
106Supply and Replacement of Candle/spun filter of RO water purifier complete all as specified and directed.
107Supply and Replacement of inline Carbon filter for RO water purifier complete all as specified and directed.
108Supply and Replacement sediment filter for RO water purifier complete all as specified and directed.
109Supply only PVC pipe 1/4" dia for inlet / outlet water connection for RO water purifier complete all as specified and directed.
110Supply and fix Suction/delivery RO motor complete all as specified and directed.
111Supply and fix RO booster pump as per existing sample complete all as specified and directed.
112Supply and fix SMPS adaptor for RO purifier as per existing make complete all as specified and directed.
113Supply and fix solenoid valve for RO purifier as per existing make complete all as specified and directed.
114Supply and fix RO filter tap as per existing make complete all as specified and directed.
115Supply and fix RO Pre filter bowl as per existing make and model complete all as specified and directed.
116Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, with two single core of 4 sqmm cable complete all as specified and directed. Make:KEI,Plaza,Havells
117Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, with two single core of 6 sqmm cable complete all as specified and directed. Make:KEI,Plaza,Havells
118Inspection visit of technical team for AC system comprises of Air cooled condensing unit of cap 11 TR qty 04 Nos. & Air handling units of Cap. 3000 CFM qty 02 Nos Following is included in the visit: 1. Servicing of the complete AC system including cleaning of Pre filters, fine filters and Hepa filters 2. The compressor and AHU will be checked for its proper functioning with electrical connections and if any defect is found, the same is to be informed. 3. Safety controls such as pressure cut outs will be tested for proper functioning and in case of any mal- functioning. 5.Inspection of Electrical cabling, Electrical switch boards and electrical accessories connected with main incomer to the system and minor repairs in electrical panels.
119AHU components exhaustive servicing including refrigerant coil/cooling coil cleaning, AHU coil cleaning, checking for any loose electrical connections, changing of thimbles etc if required separating the components and cleaning with vacuum cleaner and by using antibacterial/ antimicrobial solution. Lubricate and grease motor and blower bearing and Reassemble the components thereafter complete all as specified and directed.
120Air Cooled 11 TR Condensing units exhaustive servicing including coil cleaning with vacuum cleaner and by using antimicrobial solution , electrical connection inspection and cleaning of fan blades and repair and maintenance of fan motor etc complete all as specified and directed.
121Replacement of coarse air Prefilters of size 600 x 600 x 50 mm. Coarse filter will be G4 washable filter ( 50mm deep) class having average arrestance of 85-98% for 10 microns size as per EN779 2002, after damper at mouth of supply complete all as specified and directed.
122Replacement of fine filters bag type fine filters of size 600 x 600 x 300mm. Fine filters will be F-7 filters (300 mm deep) Average effieciency 85-95% for 1 micron size as per EN 779 2002 standards complete all as specified and directed.
123Supply & installation of Calcium dryer as per existing make complete all as specified and directed.
124Supply & installation of HEPA filters of size 880 x 610 x 150 mm as per existing complete all as specified and directed.
125Supply & installation of HEPA filters of size 610 x 610 x 200 mm as per existing complete all as specified and directed.
126Supply & installation of V Belts for AHU blower as per existing make complete all as specified and directed.
127Supply and fix AC Contactor of 32 Amp as per existing make CAT No. MNX-A2 complete all as specified and directed.
128Supply andfix MCB 3 pole 25 Amp as per existing make complete all as specified and directed.
129Supply & charging of refrigerant R407c along with pressure testing with nitrogen & vaccum complete with all respect including rectification of leakage by welding complete all as specified and directed.
130Supply and charging of Referigerant R 22 in central AC plant withpressure testing with nitrogen and vaccum complete with all respect including rectification of leakage by welding complete all as specified and directed.
131Supply and fix service valve as per existing make complete all as specified and directed.
132Supply and fix Teflon Gasket as per existing make complete all as specified and directed.
133Note for Item No. 118 to 129 herein above: Above items from Sr no 125 to 131 pertains to AC system installed at ICU in MH Patiala; The Bidder is advised to visit the plant prior quotation for checking of specification of existing AC Plant components incl AHU, Condensing Units, filters, electrical panels etc.
134Dismantling of ceiling fan 1200 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
135Dismantling of ceiling fan 1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
136Dismantling of wall mounting/Cabin fan 380/400mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
137Dismantling of industrial wall mounting air circulator fan 450/600mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
138Dismantling of exhaust fan 380/450mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
139Dismantling of exhaust fan 225/300 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed. Note for item No. 1.00 to 6.00 : It is the prime responsibility of EIC to ascertain the necessity of rewinding to a particular fan. Before handing over fan to the contractor, testing for winding shall be done in presence of EIC and all such fans shall be stored separately for subsequent repair from the contractor.
140Supply and replacement ofexhaust fan motor suitable for 225/230mm sweep complete including necessary fitting & connection complete all as specified and directed. (Make:Khaitan/Cool home/Crompton Greaves
141Supply and replacement ofexhaust fan motor suitable for 300mm sweep complete including necessary fitting & connection complete all as specified and directed. (Make:Khaitan/Cool home/Crompton Greaves
142Supply and replacement ofexhaust fan motor suitable for 380/400mm sweep complete including necessary fitting & connection complete all as specified and directed. (Make:Khaitan/Cool home/Crompton Greaves
143Supply and replacement ofindustrial wall mounted fan motor suitable for 450/600mm sweep complete including necessary fitting & connection complete all as specified and directed. (Make:Khaitan/Cool home/Crompton Greaves
144Opening up ceiling fan, exhaust fans, wall mounting/table fans, air circulator fans (any sweep, size or make) as kept unserviceable in E/M store yard for detection of defect and reassembling after cleaning, greasing and overhauling including replacement of split pins, body/blade screws and testing before depositing in store yard complete all as specified and directed. Note: Other spares necessary to be replaced shall be measured and paid for separately under following items of this schedule.
145Replacement of Capacitor 2.5/3.15 mfd 230 Volts (+) 5 % dry type complete all as specified and directed. Make- TIBCON/ELCAP/"AD/TORCON
146Supply and fixing PVC capacitor assy two ways with fixing screwsany type all as specified and directed
147Supply and replacement of ball bearing for ceiling fans of any sweep/size/ any make complete all as specified and directed. Size of 6200,6201,6202,6203,6204 & size S-7/S-8 (Make of bearing : Make ABC/SKF/NBC. Note : Ball bearing shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included under this item.
148Replacement of gun metal bush for ceiling fans, exhaust fans and cabinsfans of any makes/size complete all as of specified and directed. Note : Bush shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included under this item.
149Supply and replace rubber reel of fan complete with ms split clamp two Nos nuts and bolts complete all as specifiedand directed .
150Supply and replace fan regulator electronic, Piano type, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
151Supply and replace fan regulator electronic, modular type as per sample, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
152Replacement of Capacitor 4 mfd 230 Volts (+) 5 % dry type complete suitable for desert cooler all as specified and directed. Make- TIBCON/ELCAP/"AD/TORCON)
153Replacement of ceiling fan blade suitable for 1200 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan. (white/Browm colour/as per site requirement).
154Supplyand connecting flexible Cable of copper wire 2 core of size 23/0.0076, 0.5 sq mm (white colour)complete all as specified and directed .
155Supply & fixing as in repair louvers made out of 0.63 mm galvanised iron sheet for Exhaust Fan of any make andsize upto 300 mm complete all as specified and directed .
156Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make andsize 380mm/450mm complete all as specified and directed .
157Replacement ofPVC canopy (upper/bottom) for ceiling fan of any make andsize complete all as specified and directed.
158Supply & fixing down rodfor ceiling fans made out of MS pipe 15mm bore medium grade 60 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint complete all as specified and directed .
159Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour)including scrapping existing paint and incl writing MES Number with black paint complete all as specified and directed.
160Spray painting on outside body of the exhaustfan incl blades any size with synthetic enamel paint(smoke gray colour) including scrapping existing paint and incl writing MES Number with black paint complete all as specified and directed .
161Painting of one coat of primer red oxide and two coat of super enamelled paint for Desert cooler and matching the same on the exterior colour by metal paste/puty and of any size/ make complete all as specified and directed.
162Dismantling of desert cooler motor,(any make and type,taking out rotor removing all coils(burnt and alive)rewinding all the coils with suitable size super enamled copper wire(ISI marked) including all packing materials,insulating materials,varnishing greesing oils,reassembling,split pins, body blade screw and testing on full speed as per the direction of EIC complete all as specified and directed .
163Supply and fixing in replacement submersible PVC body Tulu pump suitable for desert cooler of any size complete all as specified and directed . Make- KHAITAN/COOL HOME/CG
164Supply and fixing in replacement wood wool padding for desert coolers on all three sides ( for any size and type of cooler) complete all as specified and directed .
165Supply and fixing flexible PVC transparent 15mm bore pipe set comprising one pipe from pump to PVC junction and 3 Nos short pieces of pipe from junction to shutter complete all as specified and directed .
166Supply and replacement offan motor 1/10HP capacity suitable for desert cooler completeincluding necessary fitting & connection complete all as specified and directed . (Make:Khaitan/Cool home/Crompton Greaves
167Supply and replacement of Desert Cooler body duly spray painted made out of 22 gauge MS sheet complete with front grill side shutters, control switch piano type 5 Amp speed regulator including lamp, wiring with suitable copper cable complete all connection complete all as specified and directed .
168Supply and fixing in replacement of PVC front grill (Jali) suitable to existing size complete all as specified and directed .
169Supply and fix as in replacement flexible copperconductor cable 3 core, PVC insulated of size70/.0076 and connected electrically to any electric devices/ofanycapacity sizetype & make etc complete all as specified and directed. Make:KEI,Plaza,Kalinga,Havells
170Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz all as specified and directed.
171S & Ffan blade of suitable size for desert cooler complete all as specified and directed.
172S & F Top Plug3 Pin 5 Amps 230 Volts complete all as specified and directed . Make: Anchor/Plaza/Kalinga/Polycab
173S & F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed.
174S&F in replacement of PVC water distributer and elbow for desert cooler ( for any type and size of cooler) complete all as specified and directed .
175Supply and replacement of PTMT Ball Valve suitable for 15 mm bore pipe (Make: Paryag) complete suitable for desert cooler complete all as specified and directed .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail