Mla Adf-Construction Of Kudiyomvayal L I Scheme In Panamaram Grama Panchayath - Electrification Mla Adf-Construction Of Kudiyomvayal L I Scheme In Panamaram Grama Panchayath - Electrification
Tender Value
3.30 Lakhs
Estimated cost
Bid Submission
02 Mar 2022
0 days left
EMD
8300
Bank guarantee accepted
Document Fee
750
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
panamaram → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Mla Adf-Construction Of Kudiyomvayal L I Scheme In Panamaram Grama Panchayath - Electrification Mla Adf-Construction Of Kudiyomvayal L I Scheme In Panamaram Grama Panchayath - Electrification
BOQ
| Sl. No. | Item Description |
| 1 | Electrification |
| 2 | od152045/2018_2019 : Supplying and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 3 | od152047/2018_2019 : Supplying and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 4 | 90.6.4.2 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 2 Run |
| 5 | 90.6.4.32 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4.00 sq.mm 2 Run |
| 6 | 90.6.4.33 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4.00 sq.mm 3 Run |
| 7 | 90.6.4.34 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4.00 sq.mm 4 Run |
| 8 | od162930/2018_2019 : Supply and wiring with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 35.00 sq mm single run without sockets. |
| 9 | od162932/2018_2019 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 35.00 sq.mm 6 Run |
| 10 | 90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 11 | 90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm |
| 12 | 90.12.9.4 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench77/63 mm or nearest size |
| 13 | 90.12.24.7 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.35 sq mm |
| 14 | 9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 15 | 9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 16 | 90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 17 | 90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. |
| 18 | 90.14.3.2 : Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardU\" section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 19 | 90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using75 x 40 mm rolled steel channel (ISMC) |
| 20 | 90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 21 | 90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 22 | 90.14.7 : Supply and providing copper earth bus in the panel board |
| 23 | 90.14.10.14 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based releasewith overload setting of 50 - 100% having adjustable OL & SC |
| 24 | 90.14.11.3 : MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT. |
| 25 | 90.14.11.12 : MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A. |
| 26 | 90.14.11.14 : MCCB AccessoriesSupply and fixing rotary handle, Directtype(including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A |
| 27 | 2.1.1 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N |
| 28 | 2.1.5 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N |
| 29 | 90.14.11.17 : MCCB AccessoriesSupply and fixing kastel interlock kit up to 250A. |
| 30 | od146203/2018_2019 : Supplying and fixing 250, HRC Fuse Base with HRC Fuse link with connections, in existing meter board |
| 31 | od146204/2018_2019 : Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 32 | od146205/2018_2019 : supply and fixing Red, Green, blue, Yellow, Orange colours LED indicator, AC/DC, as required |
| 33 | od146206/2018_2019 : Supply and fixingDigital Multifunction meter to read: V, A, F, PF-3 phase accuracy class 1 LED |
| 34 | od146207/2018_2019 : Supply and fixing 250/5 A, 5 VA, accuracy class 1, Tape wound Metering CT |
| 35 | 2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 36 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 37 | 90.14.24.2 : Supply & fixingthe following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, CylindericalType, suitable for direct connection to motors. |
| 38 | 90.14.24.9 : Supply & fixingthe following Power Capacitors 3 phase delta connected in positon and giving connection.12.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitorsuitable for direct connection to motors. |
| 39 | od146209/2018_2019 : Supply and wiring with PVC insulated stranded single core copper conductor cablesfor interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run |
| 40 | od146211/2018_2019 : Supply and wiring with PVC insulated stranded single core copper conductor cablesfor interconnecting the control devices/ equipments including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 4.0Sqmm single run |
| 41 | 90.12.24.2 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm |
| 42 | 5.3 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 43 | od146260/2018_2019 : Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 44 | od146262/2018_2019 : Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 45 | od146264/2018_2019 : Providing and fixing earth bus of 25mm X 3 mm copper strip on surface for connections etc. as required. |
| 46 | od152134/2018_2019 : Supply and drawing 2.00mm dia bare copper conductor through existing conduit / along with wiring as required |
| 47 | od146270/2018_2019 : Providing and fixing 4.75 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 48 | od152136/2018_2019 : Supply of superior quality 2.00mm (14SWG) copper earth socket and including crimping etc. as required. |
| 49 | od146280/2018_2019 : Supply of superior quality 4.75mm copper earth socket and including crimping etc. as required. |
| 50 | 5.9 : Supplying and laying 25 mm X 5 mm G.Istrip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 51 | 5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 52 | od146218/2018_2019 : Painting letters or figures with enamel paint as identification mark to SB, DB, panel board etc as required |
| 53 | od146220/2018_2019 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. |
| 54 | od152126/2018_2019 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint \"FIRE\" mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required |
| 55 | od152128/2018_2019 : supply and providing 4.5Kg Dry Chemical Powder Type fire Extinguisher with hose and clamps including fixing it to wall as required. |
| 56 | od175191/2018_2019 : Supply and providing 2.00 mm thick, 3.3 kV, Synthetic elastromeric fire retardant insulating sheet |
| 57 | od146228/2018_2019 : Supply and fixing Flush head Push Button |
| 58 | od146230/2018_2019 : supply and fixing Push button station enclosure 1/ 2/ 3 hole |
| 59 | od146296/2018_2019 : Supply and fixing 75mm dia 6Kgff/cm2PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required |
| 60 | 90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point |
| 61 | 90.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points |
| 62 | 90.3.21.3 : Supply & installation of light fittings on \"C/U\" shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. \"C/U\" brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture |
| 63 | od152067/2018_2019 : Supply, conveyance, installation, testing and commissioning of cast aluminium stove enameled elliptical shaped bulk head fittings directly on wall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required. |
| 64 | od152069/2018_2019 : Supply and providing the 9W LED lamp in the existing fittings as required |
| 65 | od152071/2018_2019 : Supply,Conveyance, installation, testing and commissioning of20 W, 2000 lumen LED, IP 65 street light fitting with aluminium housing,duly wired up for use on 230 V AC supply in the existing GI pipe and giving connections as required. |
| 66 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door |
| 67 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 68 | od146310/2018_2019 : Supplying and fixing following rating, two pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 69 | od152049/2018_2019 : Supply, providing and fixing 2.65 mm (12SWG) dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 70 | od152053/2018_2019 : Supply of superior quality 2.65mm copper earth socket and including crimping etc. as required. |
| 71 | od152055/2018_2019 : Supply and providing 12x3mm brass nut and bolt etc. as required. |
| 72 | od152057/2018_2019 : Supply and providing 25x3mm brass nut and bolt etc. as required. |
| 73 | od152059/2018_2019 : Supply and providing 25x6mm brass nut and bolt etc. as required. |
AI Tender Summary
Tender Timeline
Feb 21, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedMar 02, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 05, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender