Military Engineer Services-MES has published Provision Of Esd Flooring At Certain Labs Along With Earth Pit And Associated Elctrical Setup At ( Af ) Stn Tughlakabad Under Ge ( Af ) Tughlakabad. Submission Date for this Tender is 08-03-2022. Flooring Work Tenders in tughlakabad Maharashtra. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 01-Mar-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-03-2022 |
Sl. No. | Item Description |
1 | S&F 2 mm thickness three-layer PVC anti-static mat floor consists of a static dissipative layer on the top, conductive layer in the middle and a static dissipative layer on the bottom in the following manner complete all as per manufacturer specifications and as directed. (i) Lay the copper strip 0.05mm thick and 18mm wide with a grid of 2Mtr X 2Mtr on the entire ESD floor including by applying appropriate glue, making terminal of the copper strip. (ii)Grounding the mat by the grounding wire, one end of which is connected with the grounding button on the copper strip & the other end with earth point. (iii) Thermo welding shall be done to connect the joints in between the mats to maintain connectivity. Make of Mat: -DECO/Desco/Supreme Electrotek Solution/Electromark |
2 | S&F 1.5 mm thickness two-layer PVC anti-static mat floor consists of a static dissipative layer on the top, conductive layer in the middle and a static dissipative layer on the bottom in the following mannercomplete all as per manufacturer specifications and as directed. (i) Lay the copper strip 0.05mm thick and 18mm wide with a grid of 2Mtr X 2Mtr on the entire ESD floor including by applying appropriate glue, making terminal of the copper strip. (ii)Grounding the mat by the grounding wire, one end of which is connected with the grounding button on the copper strip & the other end with earth point. (iii) Thermo welding shall be done to connect the joints in between the mats to maintain connectivity. Make of Mat: -DECO/Desco/Supreme Electrotek Solution/Electromark |
3 | M&Lfor 10 mm thick rendering on brick wall surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
4 | M&L for two coats of oil distemper oil emulsion onnew surfaces of walls after complete removal of existing treatment including preparation of surfaces over 3mm thick wall care putty complete all as specified and directed. |
5 | Supply and fixing32x6 mm copper strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed. |
6 | M&L for copper brazing (welding) at site to connect loop copper earthing strip of any sizeafter tighten by nut, bolt , washer, checknuts of brass complete all as specified and directed. Note : Copper brazing shall be done upto 20 mtr height. Rate of necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rates quoted |
7 | M&L for earthing complete with electrode 02 Nos of copper plate of size 900 mm x 600 mm x 5 mm inter connected with 32 X 6 mm copper earth strip of length 1.5 meter and in centre shall be rod electrode as per UL 467 : 16mm dia solid rod with 250micron copper coating of length 3 mtr suitable connector for lower resistance. Alternate layers of soiland curec+ or equivalent (3Kg Bags x 2), make as per IEEE 80 : 2000, Clause 14.5D, maintenance free earting system to give earthing resistance value of <1Ohm. The soil shall be mix with backfill CURENITE (25kg bagsx2). Copper electrode shall be solid rod and surrounded with highly conductive and non corrosive nature (pH value certified) and covered with poly plastic earthpit cover. Further electrodes of GI pipe atleast 30mm dia shall be interconnected in parallel fashion in case low Ohm is not achieve able, poly plastic pit cover enclosure shall be providing in and including boundary of poly plastic pit cover of size 1.25 x 1.25 x 0.3 mtr of brick work duly plaster 15mm thick in cement mortar 1:6 and painted as per colour coding. All certificates shall be NABL LAB and CPRI certified, complete all as specified and directed. Notes : The contractor shall render a guarantee of 24 years for satisfactory working / effectiveness of earthing from the certified date of completion from manufacturing firm / executive agency. The guarantee amount towards effectiveness of earthing equal to 5% of the cost of earthing item in the form of FDR in favour of Garrison Engineer shall be furnished by the contractor. The matured amount after 10 years (which is maximum period of FDR) again will be guarantee amount for next 10 years and thereafter i.e. after 20 years matured amount will be guarantee for next 04 years. Matured amount after 20 years will be given as guarantee amount for next 04 years to meet cost of inflation for time to time which will be released after satisfactory expiry of guarantee period by the GE. |