Ge / Smb / T-48 / 2021-22 Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And Connected Services In Md And Otm Accn Of Zone Ii And Iii At Mil Stn Samba Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And, samba-Jammu And Kashmir

Military Engineer Services-MES has published Ge / Smb / T-48 / 2021-22 Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And Connected Services In Md And Otm Accn Of Zone Ii And Iii At Mil Stn Samba Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And. Submission Date for this Tender is 19-03-2022. Civil Work Tenders in samba Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

31160937
Corrigendum : Ge / Smb / T-48 / 2021-22 Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And Connected Services In Md And Otm Accn Of Zone Ii And Iii At Mil Stn Samba Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And
Open Tender
Indian
Jammu And Kashmir
samba
19-03-2022

Tender Details

Ge / Smb / T-48 / 2021-22 Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And Connected Services In Md And Otm Accn Of Zone Ii And Iii At Mil Stn Samba Repair To Flooring Plastering Joinery Plumbing Internal Water Supply Work And Connected Services In Md And Otm Accn Of Zone Ii And Iii At Mil Stn Samba

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIR TO FLOORING, PLASTERING, JOINERY, PLUMBING, INTERNAL WATER SUPPLY WORK AND CONNECTED SERVICES IN MD & OTM ACCN OF ZONE-II & III AT MIL STN SAMBA
Sl. No. Item Description
1Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed. Note- Scrap iron for window grill and angle measured separetely)
2Taking down chowkats or frames with shutters (without taking off shutters from frames) area exc 1.5 sqm but not exceeding 4 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed. Note- Scrap iron for window grill and angle measured separetely)
3Taking down shutter of any description exc 1.00 Sqm but not exc. 2.0 sqmeach and removing to store.complete all as specified and as directed.
4Factory made solid PVC door frame of size 50x47mm made out of 5mm thick prelam PVC sheet with one or more rebate reinforced with MS square tube, fixed in opening as per specification & drawing No CEPZ/TD-378/11 sheet No 1/1, etc complete all as specified and directed.
5Factory made Solid panel PVC Door Shutter, 30mm thick (style),consisting of frame made of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles & rails with suitable PVC sheet beadding and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
6Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube factory made with double side shutters, glass glazed shutter (glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
72nd class hardwood plain fillets, square / rectangular / triangular in section, clean sawn, secured with nails or brads exc. 13 Sq.cm and n.exc. 25 Sq.cm in section, complete all as specifed and directed.
8100mm long Hasp and Staple aluminium anodised.Complete all as specified anddirected.
9Magnetic catches as in kitchen cabinet shutters.Complete all as specified and directed .
10Butt hinge mildsteel cold rolled medeumwieght 50mm long, complete all as specified and directed .
11Butt hinges 100 mm medium weight stainless steel complete all as specified and directed
12Aluminium tower bolt (150 mm long), anodised barrel tower bolts of extruded section complete all as specified.
13Aluminium handle 150 mm long cast type anodised, complete all as specified and directed
14250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified anddirected .
1530 mm flaps width continuous (piano) hingesmild steel brass bright finished or electrogalvanised complete all as specified and directed .
16Pressed steel frames 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.complete all as specified and directed .
17Pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed .
182nd class hard wood 35mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified anddirected .
192nd class hard wood Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified anddirected .
20Preparation of new wooden surfaces and applying Two coats of synthetic enamal paint on wood/wood based surfaces over 10cm width or girth. complete all as specified and directed .
21Preparation of old wooden surfaces and applying one coats of synthetic enamal paint on wood/wood based surfaces over 10cm width or girth.complete all as specified and directed .
22Floor door stopper of aluminium alloy body and tongue,anodised, with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm, complete all as specified and directed .
23Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer exc.10cm width or girth. complete all as specified and directed .
24Preparation of old steel surfaces and applying one coats of synthetic enamal paint on steel surfaces over 10cm width or girth.complete all as specified and directed .
2525mm Block boards, grade 1 quality, exteriorgrade, commercial type, fixed in repairs with screws/welding totimber frame/steel angle-work, complete all as specified and directed .
2618/19 mm thick pre-laminated particle board,exterior grade, pre-laminated one side with decorative choice lamination and other side balancing white lamination as in cupboards, & drawers shelves etc. complete all as specified and directed .
27Stainless steel wire grade SS-304cloth 0.36mm nominal dia of wire and average width ofperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed .
28Stainless steel grade SS-304wire cloth 0.36mm nominal dia of wire and average width ofperture 1.40mm and fixed with stainless steel wire staples, fixed in repair, complete all as specified and directed .
29Steel ventilator with tubular frame factory made of size 79mmx39mm 16 gauge rectangular tubular frame with two top hung shutter in half portion (one Gauged & other glazed) and balance fixed to frame incl T bolt to top hung shutter & peg stay incl 10mm MS Squre as grill/guard bars, complete all as specified and directed .
30Figured sheet glass , ordinary quality 4.00 mm thk and glazing with oil putty in square not exceeding 0.5 sq m in each pain complete all as specified and directed .
31Door Seal/snake guard fixed in repair, complete all as specified and directed .
32150mm, MS ordinary door springplate type incl roller and roller plate complete all as specified and directed .
33150mm, MS ordinary door springplate type incl roller and roller plate , fixed in repair, complete all as specified and directed .
34MS powder coated dropery rods fixed in repair of dia 20mm with funnels, side brackets & end caps etc on each side complete all as specified and directed .
35Floor door stopper of aluminium alloy body and tongue,anodised, with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm,fixed in repair, complete all as specified and directed .
36Aluminium (anodised) doubleleaf powder coated door fabricated from standard aluminium box sections all as specified and directed (Make : Hindalco / Indal / Ajit India) and comprising of the following :- a) Chowkhat / frame 100 x 44 x 1.5 mm thick b) Top & lock rail and styles of shutters 83x44x1.5 mm thick. c) Bottom rail of shutters110x44x1.5 mm thick. d) Hydraulic door closure ISI Marked (Make Amar/Sandhu/Priya -01 No each shutter) e) Upper and lower panel of 4.0 mm thick Heat obserbing glass (Make : Saint Gobain / Modi float / Triveni float glass/Hindustand Pilkington glass works) fixed with standard aluminium beading and rubber. f) Push plate standard lock and key as approved by GE g) Stain less steel / aluminium anodised 100 mm butt hinges - 04 Nos each shutter h) Aluminium door stopper with rubber pack - 01 No each shutter j) Aluminium anodised handle "D" type of 250mm dsize -2 Nos each shutter k) Aluminium anodised tower bolt 200 mm long ISI marked - 2 Nos Note : All fittings are powder coated.
37Colour coated Aluminium louvers with frame of ofsize 44 x 44 mm with suitable Frosted Glass inclaluminium Jali of size 75 x 75mm complete all as specified and directed .
38Providing Labour only for repair to Aluminium door any size with replacement of unserviceable/broken accessories incl taking down & refixing complete all as specified and directed .
39Aluminium(extruded section)door closerhydraulicallyregulateddesignation no-3 , universal type , suitable foor doorshuttersof 851 to 1000mm in widthand ofweightbetween61 to 80 kgand fixed in repairs Make "GodrejISI Mark
40Sheet glass 3mm thick ordinary quality , n.exc 0.50 sqmfixed with oil putty or wooden beading in each pane , complete all as specified and directed .
41Taking down cement plaster on brick/concrete or stone walls, ceiling, etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed .
42Demolition of brick work or stone masonry, built in cement mortar incl all quoins, arches pillars etc complete all as specified and directed .
43Brick work withsub class"B" burnt bricks straight or curved on planexc. 6 m mean radius built in CM 1:6 complete all as specified and directed .
44Rendering 15 mm thick in CM 1:4 on fair/unfair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed .
45Rendering 10 mm thickon fair faces of brick work or concrete surfaces in CM 1:6finished even and fair without using extra cement, complete all as specified and directed .
46Rendering 5 mm thickon concrete surfaces in CM 1:3 in ceiling andfinished even and fair without using extra cement including three coats of white wash, complete all as specified and directed .
47Preparation to newly plastered surfaces of walls and applying two coats of cement based paints etc,complete all as specified and directed .
48Preparation of newly plastered surfaces ofwalls and applying two coats of oil bound distemper over a coat of chalk whiting etc complete all as specified and directed .
49Taking down door shutters of any description exceeding 1 sqm and not exceeding 2 sqm each and refixing the same after easing and adjusting/resizingcomplete all as specified and directed .
50Dismantling timber scantling 40 sq cm and over in section framed work in any position. complete all as specified and directed .
512nd Class hard wood plain, solid, straight chowkats or frames, wrought,framed, rebated on the solid, rounded or chamfered put together with glue, pinned at joints.complete all as specified and directed .
52Dismantlingof wall & ceiling Boards ( fibre,pulp,insulation etc. ),or insulation board/slabs/ blankets ,any thickness, including cover fillets. completed all as specified and directed.
53Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet used instead of plain colour sheet inclusive of solvent cement and fixing at site on PVC frame and PVC sheet fillet as per specifications and drawing,completed all as specified anddirected.
5452 mm thick PVC partition consisting of 12 mm thick plain solid PVC ply sheet reinforced with frame work made from 40mm x 20mm MS tubes in between two MS tubes, 5mm thick plain heat moulded "C" channel of size 75mmx50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply opanel shall be inserted in the PVC "C" channel. The first & last MS tube should be errected such that it is inside a PVC "C" channel in between adjoining plastic panel, 5mm thick x 75mm width plain PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete but 12 mm thick both side printed solid PVC plastic ply and 5mm thick printed heat moulded "C" channel, complete all as specified and directed.
55Dismanting of floor hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
56Light shade vitrified tiles (1st quality) 10 mm thick(square/rectangular joint free) , double charged, polished area of each tiles not exceeding 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6, complete all as specified and directed
57Light shade vitrified tiles (1st quality) 10 mm thick(square/rectangular joint free) , double charged, polished area of each tiles not exceeding 0.36 sqm in skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including rendering on brick or concrete surface of wall10 mm thick in CM 1:4, complete all as specified and directed
58Non skid coloured ceramic tiles (1st quality) 7 to 8mm thick(square/rectangular joint free) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortor 15mm thick in CM 1:6, complete all as specified and directed
59Glazed coloured ceramic tiles (1st quality)joint freein vertical surfaces of wall of size450x350x7mm/350 x250 x 7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to matchover and including 10 mm thick rendering in CM 1:4on brick /concrete surfaces complete all as specified and directed .
60Demolition of plain cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and directed.
6125 mm thick cement concrete 1:2:4, Type B-1 (20 mm graded stone aggregate)as in sub-base of floor for tiles/Kota stone finished even & rough, complete all as specified and directed
62Cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or euqivalent make of approved by GE cold applied.Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equavalent make as approved by GE, createdSSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm.Lay Geotex of 45 GSM/fiber mesh simultaneously and paste it properly with overlap of 50mm.
63Allowed of first coat to dry for 10 to 12 hrs. Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller.Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note :Application of water proofing treatment will be done by authorised applicator only.
64Preparing existing surface of floor and brushing neat cement slurry with 3.0 kg of cement per sqm, complete all as specified and directed.
65Rendering 15 mm thick in CM 1:3 on concrete surfaces and mix with WPT compound and finished even and smooth using neeru finish to plastering as specified in sunken slab , complete all as specified and as directed.
66PCC 1:4:8 Type D -2 using 40 mm graded crushed stone aggregate, 75 thick as in sub-basefloor , complete all as specified and as directed.
67Granite work (any type) 20 mm thick(table, rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match over 15 mm thick screed in CM (1:4), complete all as specified and directed.
68Taking down GI pipe 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
69Taking down GI pipe 20mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
70G.I. pipe 15mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
71G.I. pipe 20mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
72Cutting chases,pining in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing steps, cills, sunshades ,shelves,lintels,etc.; and cutting chases for concealed water tubing or concealed conduit,wiring,etc,and making good cutting not exceeding 10 cm girth in brick walls. complete all as specified and directed.
73Vitreous china ,Squatting pan "Orissa" pattern size 580x440mm white with integral foot restincluding all joints and making good to the floor etc fixed in repair ,complete all as specified and directed.
74Vitreous china wash down water closet pan padestal pattern white, excluding fixing bolts, flushing cistern but including flush pipe, seat and cover, fixed in repairs complete all as specified and directed.
75Vitreous china wash down water closet pan padestal pattern white, Single piece WC with PP soft close seat cover, hinges, fixing accessories and set cistern fittings as per Jaquar Cat part No. CMS-WHT-103851P180SPP or equivelent module in Hindware/Cera/Prayag , fixed in repairs complete all as specified and directed.
76Vitreous china urinalmake Jaquar Cat Part No. ECS-WHT-253 or equivelant module in Hindware/Cera/Prayag, fixed in repairs,complete all as specified and directed.
77Vitreous china WHB size as permake of Jaquar Cat Part No. CMS-WHT-103801 or equivelant module in Hindware/Cera/Prayag, fixed in repairs, complete all as specified and directed.
78Counter top WHB , oval type, white of size make of Jaquar Cat Part No. ECS-WHT-601 or equivelant module in Hindware/Cera/Prayag, fixed in repairs, complete all as specified and directed.
79Vitreous china urinal partion, white of size 310x700 mm,fixed in repairs, complete all as specified and directed.
80PVC valveless, 10 ltrs, Dual type syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repair, complete all as specified and directed
81C.P. shower rose125 mm size for 15 mm bore pipe, fixed in repair, complete all as specified and directed
82C.P. Bib taps(Fancy type) 15mm bore cast copper alloy with crutch or butter fly handle,screwed down,screwed for iron pipe or brass ferrule in repairs complete all as specified and directed
8315mm bore C P (Fancy type) stop valves , cast copper alloy, screweddown, highpressure, withcrutch or butterfly handle, screwed both ends foriron pipe orfor unions in repairs.complete all as specified and directed .
8415mm bore Brass C P (Fancy type) wall mixer for Hot & Cold water, screwed both ends foriron pipe orfor unions and fixed in repairs.complete all as specified and directed
85C.P. Angle valve (fancy type) 15mm bore,cast copper alloy screwed down,high pressure,screwed both ends for iron pipe or unions( concealed type) complete all as specified and directed
86Bevelled edge looking mirror 600x450mm selected quality glass mounted on 6mm thick AC building board or commercial ply with PVC frame, complete all as specified and directed
87Tubular towel rail 20 mm dia, brass chromium plated, 60cm long between flanges complete all as specified and directed
88C.P. pillar tap( fency type 15mm bore)cast copper alloy with capstan head CP screwed down high pressure with or without letter and"Hot" or "Cold" with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed
89PVC connection 15mm dia, 450mm long with brass nut complete all as specified and directed
90C.P Brass grating with hole 125mm dia as per sample to be fixed with white cement complete all as specified.
91Dismantling of CI or Concrete drain pipes up to 150mm dia, jointed in cement mortar and taking out from trenches,if required complete all as specified and directed .
92Taking down eaves gutters and PVC rainwater / drain pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning for refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed .
93PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
94PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
95PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
96PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
97PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
98PVC (SWR) 110mm bore bends any radius, complete all as specified and directed .
99PVC (SWR) 75mm bore bends any radius, complete all as specified and directed .
100PVC (SWR) 110mm bore bends any radius with access door, complete all as specified and directed .
101PVC (SWR) 75mm bore vent cowl complete all as specified and directed
102PVC (SWR) 110mm bore branch piece, single (single Y) equal or unequal, complete all as specified and directed .
103Taking down cement plaster from chajjas or facia etc, incl. dismantling of damage conerete & repair the same with PCC 1:2:4 type B-0 (using 12.5mm crushed stone aggregate) on chajjas of any widthand applying 10mm thick cement plaster in CM 1:3 mixed with water proofing compound(Water proofing compound shall be measured & paid separately) , finished even & smooth using extra cement, complete all as specified and as directed. Noe- Rate quoted shall be deemed to include for scaffolding/formwork for single/double story building of height 8.0 mtr and making good the disturbed surfaces.
104Dismantling brick tarracing tiles single layer on roof and top or complete removal of existing tretment, complete all as directed.
105Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing inlow lying area where directed and providing following :- (a) Applying brushing neat cement slurry with 3.0 kg of cement per sqm. (b)Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c)After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface.
106(d)After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (e)Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slope from lowest line of sloping roof towards ridge. (f) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed by Engr-In-Charge.
107PCC 1:2:4 type B0 (12.5 mm graded crushed stone aggregates) asin roof padding for slopping purpose including mixing ofliquid water proofing compound as per manufacture"s instructionsfinished even and smooth without using extra cement ,complete all as specified anddirected
108Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
109Supply only of liquid water proofing compound ISI marked complete all as specified and directed
110Cement concrete tiles 20cm x 20cm x 20mm thick machine pressed, set, jointed and pointed in neat cement slurry with gray cementin floors/roof pointed in CM 1:3 mixed with liquid water proofing compound over and including 15 mm thick screed bed in CM 1:4 , complete all as specified and directed. (WPC shall be measured and paid separetly)
111Disconnecting existing tanks, cap exc 500 ltr and not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.
112Rotational moulded polye- thylene water storage tanksof capacity 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I& including dismentling old U/S tank, complete all as specified and as directed.
113Rotational moulded polye- thylene water storage tanksof capacity 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including all necessary connections all as specified in SSR Part I & incl dismentling old U/S tank,complete all as specified and as directed.
11420mm bore ball valves high pressure of PTMT with epoxy coated Aluminiumrod& highdensity plastic ball screwed for iron pipe and fixed. Fixed in repair,complete all as specified and as directed.
115Dismantling, asbestos cement, corrugated or semi-corrugated sheets in roofs incl ridge, complete all as specified and as directed.
116Dismantling, plain, corrugated or semi-corrugated steel sheeting, any gauge, thickness, incl Nainital pattern & similar in roof coverings incl ridge, complete all as specified and as directed.
117M S Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed.
118Roof trusses (framed), trussed, purlins, rafters, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, flat, hollow sections) including distance pieces, cleats, welding/rivets/nut/bolts/washer etc,conforming to Fe 410-W (Gde-E-250) quality -A, complete all as specified and as directed.
1192nd class hard wood scantling, clean sawn, timber framed work andfixed , complete all as specified and as directed.
1206mm thick asbestos cement,corrugated or semi corrugated sheets in roofs,walls etc fixed with L-type or J-type or cranked hook bolt. complete all as specified and as directed.
1216mm thick Asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets fixed with L-type or J-type or cranked hook bolt. complete all as specified and as directed.
122Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mmthick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
123Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mmthick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
124Washers to bolts for GI sheets fixing, complete all as specified and directed.
125Polycarboneted roof sheet (1st quality) 5 mm thick, complete all as specified and directed.
126Designer ceiling board size (600X600X4mm)in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white.The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheetof size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres.Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modulescross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc complete all as specified and directed.
127Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail