}

Maintenance Of Ei Works In Food Processing And Other Workshop Building At Govt. Iti Ambassa Dhalai Tripura, ambassa-Tripura

Public Works Department-PWD has published Maintenance Of Ei Works In Food Processing And Other Workshop Building At Govt. Iti Ambassa Dhalai Tripura. Submission Date for this Tender is 02-03-2022. Electrical Maintenance Tenders in ambassa Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

31149359
Maintenance Of Ei Works In Food Processing And Other Workshop Building At Govt. Iti Ambassa Dhalai Tripura
Open Tender
Indian
Tripura
ambassa
02-03-2022

Tender Details

Maintenance Of Ei Works In Food Processing And Other Workshop Building At Govt. Iti Ambassa Dhalai Tripura

Key Value

Document Fees
INR 1000 /-
EMD
INR 5264.0 /-
Tender Value
INR 5.26 Lakhs /-

BOQ Items

Name of Work: Maintenance of E.I. works in food processing & other workshop building at Govt. ITI, Ambassa, Dhalai, Tripura.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:- (As per TSR 2017, Sl- 101)
2Short point:-
3Medium point:-
4Long point:-
5Wiring for Circuit/Sub-main wiring with the following sizes of PVC insulated copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- (As per TSR 2017, Sl- 501)
62 x 1.5 sq.mm
72 x 2.5 sq.mm
84 x 4 sq.mm
94 x 6 sq.mm
10Supplying and fixing of the following PVC casing capping with all accessories etc. as required.-(As per TSR 2017, Sl- 601)
1125 x 12mm
12Supplying and fixing of the following modular accessories including necessary connection etc. as required:-(As per TSR 2017, Sl- 604)
13Ding dong/Musical call bell
145/6 amps piano type switch
1515/16 amps piano type switch
163 pin 5/6 amps piano type socket
173/6 pin 15/16 amps piano type socket
1832 amps DP kit kat switch:-
19Angle/batten/pandent holder
20Supplying and fixing of the following modular accessories including necessary connection etc. as required:-(As per TSR 2017, Sl- 605)
21102mm x 102mm (4" X 4") :-
22152mm x 203mm (6" X 8") :-
23300mm x 380mm (12" X 15") :-
24Supply and fixing of 25 x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. .(As per TSR 2017, Sl- 706)
25Providingearthing systemwith maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 50 kg, terminalsize 32x 6mm i/c accessories with masonry enclosure of CIcover plate size 12"x 12" having locking arrangement including CC works etc as required:-.(As per TSR 2017, Sl- 718)
26Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable(FR)ISI marked, BEE 1 star/minimum service value 4.0:(As per TSR 2017, Sl- 802)
27Supplying & fixing of electronic 5 step fan regulator in existing switch board including necessary connection etc as required:--(As per TSR 2017, Sl- 806)
28Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-.-(As per TSR 2017, Sl- 822)
2920 x 12mm
30Supplying and fixing of the following luminaries (Surface/Recess) including necessary accessories and connection with 2x1.5 sq.mm PVC insulated coper conductor cable(FR) etc. as required.(As per TSR 2017, Sl- 901)
31Single FTL fittings with 36/40 W FTL,electronic ballast, holder.
32Supplying and fixing of the following lighting accessories(Lamp, Ballast,Starter,Ignitor etc) and connection etc. as required.(As per TSR 2017, Sl- 902)
3336/40 WFTL.
34Supplying and fixing of 30 - 32 ampsIndustrial P&S unit (3P - N- E)without MCB etc. with necessary connection as required.(Schneider/ Indo Asian)
35Supplying & fixing of following ratings MCBB/C curve having breaking capacity10 KA in the existing MCB DB including connectionas required:-(As per TSR 2017, Sl- 1013)
366 to 32 amps SP MCB:-
376 to 32 amps DP MCB:-
386 to 32 amps FP MCB:-
39Supplying & fixing of following ratings isolator in the existing MCB DB including connection etc as required:-(As per TSR 2017, Sl- 1014)
4063 amps FP isolator:-
41Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.-(As per TSR 2017, Sl- 1006)
422+6 / 8 way MCB DB (single door):-
43Supplying and laying of the following XLPE insulated PVC sheathed alluminum armoured cable including connection etc as required.(As per TSR 2017, Sl- 1101)
443 core 4 Sq mm
45Excavation of earth for cable tranch of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks/ metre for protection including ramming, consolidating to the original shape as required:-(As per TSR 2017, Sl- 1306)
46Drawing of armoured/un-armoured cable with proper saddeling etc as required:-(As per TSR 2017, Sl- 1307)
47Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-(As per TSR 2017, Sl- 1313)
48Supplying & fixing of digital/ astronomical time switch including necessary connection etc as required:(As per TSR 2017, Sl- 1308)
49Supplying & fixing of following power contactors including necessary connection etc as required:-(As per TSR 2017, Sl- 1309)
5018-25 amps 2 pole power contactors:-
51Supplying and fixing of following surface/recess mounting LED luminaries complete with powder coated die cast housing and high efficiency diffuser including necessary connection etc. as required:--(As per TSR 2017, Sl- 1401)
5212-18 watt (round/square shaped) LED light fixture:-
53Supplying and fixing of following outdoor LED luminaries complete with powder coated die cast housing and heat resistant tempered glass/diffuser including necessary connection etc. as required:-(As per TSR 2017, Sl- 1402)
5430-36 watt LED street light fixture (IP 65):-
55Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2017, Sl- 1301)
5640 mm dia:-
57Supplying and fixing of 10 watt LED retrofit lamp with polycarbonate body and aluminium heatsink including necessary connection etc. as required:--(Approved as per letter no-5(205)/ ACE/ PROJECT / 2017/7150-52, DATED-21/12/2017)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail