| 1 | Dismantling of flexible pavements and disposal of dismantled Materials upto a lead of 1000 mtrs. Stacking serviceable and unserviceable Materials separately. (MoRTH specification : Clause 202) BY MECHANICAL MEANS Bituminous Courses |
| 2 | Transportation of excavatedearth from site including loading – unloading etc. complete with all lead and lift.(For 5 Km lead) |
| 3 | Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS:8887 & manufacturer’s specifications @6 kg/10 sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specifiedrates and temperatures (including cleaning of road surface) as per MoRTH specification : Cl. 502, 112 |
| 4 | Providing and applying tack coat on the prepared surface, with bitumen VG10 as per IS:8887 & manufacturer’s specifications @0.2 kg/sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification Cl. 502, 112. |
| 5 | Providing and laying Dense Bituminous Macadam on prepared surface with specified graded crushed aggregates (as per table 500-9, 500-10 and design mix) for base/binder course including loading of Material with F.E. loader, heating of binder (including cost of anti stripping compound, wherever required) aggregates and filler in hot mix plant (40-60 TPH), transporting the mixed Material by tippers and laying with sensor paver finisher as per clause 504.3.5 to the required level and grade, rolling by self propelled power rollers and vibratory rollers or pneumatic tyred roller, 150-250 KN. TP=0.7 Mpa, to achieve the desired density (approved by the department) but excluding primer/tack coat. (MoRTH specification : clause 505, 112). with all lead & lift (a) 50-75mm compacted thickness with 4.5% bitumen content VG30 grade |
| 6 | Providing and laying Bituminous Concrete as per Design Mix on prepared surface with specified graded stone aggregates as per Table 500-17, for wearing course including loading of aggregates with F.E. loader and hot mixing of binder (including cost of anti-stripping compound, wherever required) and 3% cement filler with aggregates in Hot Mix Plant 40-60 TPH, transporting the mixed Material with tipper to paver and laying with sensor paver finisher (as per clause 504-3.5) to the required level, grades and rolling with vibratory compactor and pneumatic tyred roller 150-250 kN, TP = 0.7 Mpa, to achieve the desired density (approved by the department as per job mix) excluding cost of primer/tack coat. (MoRTH specification : clause 507). with all lead & lift 30-45mm compacted with 6% binder(a) With straight run bitumen grade VG30 |
| 7 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 8 | Construction of speed breaker of IRC standard having width of 3.70 M including cost of stone aggregate (50-25mm) size hire charges for roller for consolidation and compaction and other machines required for the work (including cost of bitumen) |
| 9 | Road Delineators Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming toIRC-79 and the drawings. |
| 10 | Raised Pavment Marker ( Cats Eyes): Supplyingand Fixing of Molded Shank Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 – DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the engineer. The contractor shall submit 2 years pre qualified warranty certificate from the manufacturer for satisfactory field performance during the time of bid submission |
| 11 | Supply of ‘L’ type bollard made out of 1.25mm thick MS sheet height 134cm welded in circular type ring section having upper dia 15cm and lower dia 21 cm with another attachment of 15×15 cm circular section with 15cm face plate and hold fast at bottom whole body is processed in white stoving enamel and red reflective 3 hands, each of 7.5cm end one reflective sheet of 15cm dia provided to it complete in all respect. |
| 12 | Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing |
| 13 | Providing, laying, spreading and compacting crushed graded stone aggregate as per Table 400-10 & 400.11 to Wet Mix Macadam specifications including premixing the Material with water to OMC in mechanical mixer (Pug mill) as per design mix, carriage of mixed Material by tipper to site laying in uniform layers, with motor grader/F.E. loader/Paver Finisher, in sub-base/base course on a well prepared under-base and compacting with Vibratory Roller to achieve the desired density including lighting, guarding, barricading and maintenance of Driversion etc. (MoRTH specification : Clause 406). with all lead & lift |
| 14 | Provinding and laying of paver block as per IS 15658 : 2006 (Indian standerd for Precast concrete block for Paving -specification) and IRC :SP:63-2004(guidelines for the use of interlocking concrete blockPavement) (from BIS approved manufactrersM-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. Categary A Denated units to key into each other on four faces zigag shapeas per IRC SP 63:2004 |
| 15 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:4 ( 1-Cement : 4-Sand). |
| 16 | Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900).300 mm dia |
| 17 | 500 mm dia |
| 18 | Dry lean cement concrete sub - base.Construction of dry lean cement concrete 1:3:6 sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size ofcoarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blening to be as per Table 600-1, cement content not to be less than 200 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing. |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work |
| 20 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. |
| 21 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 100 mm dia |
| 22 | Flyash Brick work with flyash Flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 23 | laosnd }kjk fuEu çtkfr;ksa ds ikS/kksa dh vkiwfrZ ,oa yxkukAikS/kk LoLFk gksuk pkfg,A laosnd }kjk ikS/kk jksi.k ls iwoZ çR;sd [kìs esa vçoqM [kkn o vko’;drk vuqlkj dhV uk’kd Mkyuk gksxk ,oa ikS/kk yxkus ds i’pkr~ de ls de 20 ls 25 yhVj ikuh çfr ikS/kk nsuk gksxkAikS/ks ¼1½ \"kh’ke ¼2½ uhe¼3½ ihiy ¼4½ xqy eksgj¼5½ veyrkl ¼6½ tdjsUMk¼7½ dsf’k;k ;kek ¼8½ v’kksd ¼9½ dpukj ¼10½ v’kksd isUMqyk¼11½ dnEc ¼12½ vtqZu ¼13½ djat ¼14½ vke¼15½ vkaoyk ¼16½ ve:n¼17½ \"kgrwr ¼18½ cksVy ike¼19½ ,fjdk ike ¼20½ nslh ike ¼21½ pkbZuk ike ¼22½ ;quhilZ ¼23½ cksxu csfy;k¼24½ QkbZdl |
| 24 | Providing and Fixing of different colured Deoli slate stone size 270mm x 135mm wide (approxmate) as a cladding on walls in cement sand mortar 1:4 with deep grove pointing in cement sand mortar 1:3 including painting curing etc. in all respect ( colour of tiles should be minimum five colours on face i.e Cooper, silver, Golden, Panther) the patteren and colour of slate stone cladding and pointing will be as per direction of engineer-in-charge. (this item includes base plaster on brick masonary) |
| 25 | Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc.Good soil of earth |
| 26 | Spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). |
| 27 | Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.75mm x 15mm x 3.15mm |
| 28 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 29 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including gettingout the excavated soil anddisposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available : Ordinary rock |
| 30 | Hard rock(blasting prohibited) useful MATERIAL 30% |
| 31 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 32 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.: M20 grade Nominal Mix |
| 33 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor Three level. Hot rolled deformed bars (IS : 1139). |
| 34 | Centering and Shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 35 | Providing and fixing of Reinforced Ferro-Cement Drain cover designed of class \"A\" & \"AA\" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti-corrosive bitumen painted M.S. plate, Rim and on M.S. lifting hooks, admixture like plasticizer bond-improving compound, shrinkage resistance compound, abrasion resistant complete as per approved design etc. Span 300 mm to 450 mm Standard Size 600 x 800 mm |
| 36 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.160 mm dia |
| 37 | Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900).1000 mm |
| 38 | Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. : BY MECHANICAL MEANS : Depth upto 3m |
| 39 | In Hard Rock [MoRTH Specification : Clause 301, 302, 303]. : Blasting Prohibited |
| 40 | Dismantaling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled Material, disposal of unserviceable Material and stacking the serviceable Material with all lift and lead of 1000 metres. [MoRTH Specification: Clause 202].BY MECHANICAL MEANS Cement concrete grade M-15 & M-20 |
| 41 | Providing A.C. pipe Weep holes 150mm dia in Masonry/plain Concrete/Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification. [MoRTH Specification : Clause 2205]. |
| 42 | Providing and fixing 20mm thick Compressible Fibre Board in expansion joint complete as per drawing and technical specification in MoRTH specification : clause 2605. |
| 43 | Drilling of holes upto 50mm dia suing rotary percussion drilling machine in any strata, fixing of casing pipe washing of holes by alternate cycles of air & water jetting till cleaning water flows from the pipe complete. : For pier, abutment etc. |
| 44 | Grouting of foundation by chemical cement/ cement sand slurry of specified consistency conforming IS:6066 using single/double packed assembly in either descending or ascending order |
| 45 | Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. : With 20mm nominal size aggregate : P.C.C.M-20 grade |
| 46 | Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. : With 20mm nominal size aggregate : R.C.C.M-30 grade By using Batching Plant |
| 47 | Providing and laying steel reinforcement at any level in foundation complete as per drawing and technical specification. [MoRTH Specification : Section 1600]. : HYSD bar reinforcement |
| 48 | Structural cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification. : Design mix concrete – [MoRTH Specification : Section 1500 & 1700]. : RCC in M-30 grade, including form work : Upto 5m height |
| 49 | Steel reinforcement in substructure complete. [MoRTH Specification : Section 1600] : HYSD reinforcement |
| 50 | Structural RCC/PSC upto a height of 5 mtr. for reinforced concrete in superstructure complete including steel formwork, scaffolding etc. As per drawing and technical specification. Design mix concrete. [MoRTH Specification : 1500& 1700]. : RCC M-30 grade : Solid slab superstructure By using Batching Plant |
| 51 | Providing and laying HYSD bar reinforcement at any level in superstructure complete as per drawing and technical Specification. [MoRTH Specification : Section 1600] |
| 52 | Reinforced cement concrete wearing coat M-30 grade at any level including formwork and reinforcement complete as per drawing and technical Specification. [MoRTH Specification : Clause 2204, 1500 & 1700]. |
| 53 | Providing and laying reinforced cement concrete grade M-30 design mix railing complete as per drawing and technical Specification. [MoRTH Specification : 2703, 1500, 1600 & 1700]. Precast RCC railing |