|
| 1 | Earth work in excavation by mechanical means(Hydraulic excavator) / manual means in foundation trenches or drain (not exceeding 1.5m in width or 10sqm on plan),including dressing of sides and ramming of bottoms, lift upto 1.5m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m 2.8.1. All kimds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level : 1:5:10 (1 Cement : 5 Fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | (4.1.8) Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto pilnth level: 1:4:8 (1 cement :4 fine sand :8 graded stone aggregate 40mm nominal size) |
| 4 | Providing centering and shuttering including strutting, propping etc. and removal of form work for Foundation, Fottings, bases for columns etc. for mass concrete |
| 5 | Providng centering and shuttering including shrutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders ,bressumers and cantilevers |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering , finishing and reinforcement -All work upto plinth level : 5.2) Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15 degree landings, balconies,shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level, excluding the cost of centering ,shuttering, finishing and reinforcement with 1:1:5:3(1 cement: 1.5 coarse sand) : 3 graded stone aggregate 20mm nominal size) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars |
| 8 | Filling available excavated earth (excluding rock) in trnches , plinth, sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m |
| 9 | Boulder/Stone filling tightly dry hand packed under floor as per specification or as per direction of the Engineer-In charge with in all leads. Lifts and other incidentals carriage of material |
| 10 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming toIS:2222 in superstructure above plinth level upto floor level in cement mortar 1:6:1 cement :6 coarse sand) : 6.3.1 With F.P.S. ( non modular) bricks |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level, 6.13.2 Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 12 | 9.1.2) Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast ligs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood |
| 13 | 9.53) Providing 40*5 mm flat iron hold fast 40cm long including fixing to frame with 100mm diameter bolts, nuts, and wooden plugs and embedending in cement concrete block 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size |
| 14 | 9.7) Providing and Fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( Area of opening for panels inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled and glazed shutters 25mm to 40 mm thick : |
| 15 | 9.7.1) 30mm thick shutter ( 2nd Class teak wood) 55% |
| 16 | 9.7.5.4) Pre -laminated particle board with decorative lamination on both sides, Grade I ,Type II, IS 12823 marked |
| 17 | 9.7.7.1 4mm thick glass pane ( weight not less than 10Kg per sqm) |
| 18 | 9.130.1) Providing and fixing cup board with 25mm thick veneered particle board IS : 3097 marked , exterior grade ( Grade I), of approved make, including 2nd class teak wood lipping of 25mm wide * 12mm thick with neccesary screws and bright finished stainless steel plano hinges , complete as per direction of Engineer -in - Charge.With decorative veneering on one side and commercial veneering on other side |
| 19 | 9.27) Providing and fixing wire gauge shutters using galvanized M.s. wire gauge of average width of apperture 1.4 mm in both directions with wire of dia 0.63mm , for doors, windows and clerestory windows with hinges and neccesary screws : 30 mm thick shutter, 9.27.2.2.1. with ISI marked M.S. pressed butt hinges bright finished of required size ( 30mm thick, 2nd Class teak wood |
| 20 | 9.51) Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of apperture 1.4 mm in both directions with wire of dia 0.63 mm all complete |
| 21 | 9.51.1 With 2nd class teak wood breading 62*19mm |
| 22 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete: |
| 23 | 9.70.1 125x64x1.90 mm |
| 24 | 9.70.2 100x58x1.90 mm |
| 25 | 9.70.3 75x47x1.80mm |
| 26 | 9.70.4 50x37x1.50 mm |
| 27 | 9.96.1) Providing and fixing aluminium sliding door bolts, ISI marked anodised ( anodic coating not less than grade AC 10 as per IS:1868), Transparent or dyed to required colour or shade, with nuts and screws etc. complete: |
| 28 | 300x16mm |
| 29 | Providing and fixing aluminium tower bolts, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. |
| 30 | 250x10mm |
| 31 | 150x10mm |
| 32 | Providing and fixing aluminium handles,ISI marked, anodised( anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 33 | 125mm |
| 34 | 75mm |
| 35 | i) Cement concrete flooring 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete: 40mm thick with 20mm nominal size stone aggregate |
| 36 | Providing and laying Ceramic glazed floor tiles of the size 300x300mm( thickness to be specified by the manufacturer) of 1st quality conforming toIS:15622 of approved make in colours such as White , ivory, Grey.Fumes Red Brown, laid on 20mm thick cement mortar 1:4(1 Cement : 4 Coarse sand ), Jointing with grey cement [email protected]/sqm including pointing the joints with white cement and matching pigment etc. complete |
| 37 | Providing andfixing 1st quality Ceramic glazed floor tiles conforming to IS:15622(thickness to be specified by the manufacturer) of approved make in all colours, shade except burgundy, bottle green,black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3(1 cement:3 coarse sand) and joining with grey cemnt slurry @3.3kg per Sqm. including pointing in white cement mixed with pigment of matching shade complete.: |
| 38 | 15mm cement plaster on the rough side single or halfbrick wall of mix :13.2.1 1:4 (1 Cement : 4 fine sand |
| 39 | 20mm cement plaster of mix : 13.3.2 1:6( 1 Cement : 4 fine sand ) |
| 40 | ii) Providing and fixing M.S. grills of reuired pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to opening /wooden frames with rawl plugs screws etc. |
| 41 | 4.17 Making plinth protection 50mm thickof cement concrete 1:3:6 (1 cement :3 coarse sand (zone =III) :6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finsihing the top smooth |
| 42 | 10.16) Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 43 | 10.16.1 hot finished welded type tubes |
| 44 | 10.19) Providing and fixing mild steel round holding down bolts with nuts and washer plates complete |
| 45 | Providing and fixing precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single lenght upto 12 metre or as desired by Engineer-in -Charge. The sheet shall be fixed using self drilling/self lapping screws of size(5.5x55mm) with EPDM seal , cpmplete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 46 | Providing and fixing precoatedgalvanized steel sheet roofing accessories 0.50mm ( +0.05%) total coated thickness ,Zinc coating 120grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete 12.51.1 Ridges palin ( 500 -600mm) |
| 47 | Providing and fixing mutilpurpose cement board (high pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete( frame work to be paid separately)12.26.26mm Cement bonded wood particle board as per IS: 14276 |
| 48 | Distempering with oil bound washable distemper of approvedbrand and amnufacture to give an even shade: 13.41.1 New work ( two or more coats) over and including water thinnable primimg coat with cement primer |
| 49 | Finishing walls with water proofinbg cement paint of reuired shade:13.44.1 New work ( two or more coats [email protected]/10 Sqm) |
| 50 | Applying priming coat : 13.50.1 With ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood |
| 51 | 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90ltr/10sqmof approved brand and manufacture |
| 52 | WATER SUPPLY AND SANITARY INSTALLATION |
| 53 | 18.12) Providing and fixing G.I. pipes complete with G.I fitting including trenching andrefilling etc. |
| 54 | 18.12.115mm dia nominal bore |
| 55 | 18.12.2 20mm dia nominal bore |
| 56 | 17.1) Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 ltr low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device( handle lever)conforming to IS:7231, with all fitting and fixture complete, including cutting and making good the walls and floors wherever reuired:17.1.1 White Viterous china Orissa pattern W.C pan of size580x400mm with integral type foot rests |
| 57 | Providing and fixing PVC P or S trap for water closet (squatting pan) ISI marked including jointing the trap with the pan and PVC pipe with approved adhesive etc. complete including carriage of materials within all leads and lifts and other incidentials |
| 58 | 100 mm dia ( one hundred ten milimetre dia |
| 59 | Providing And fixing heel rest sanitary bend 100mm dia 17.40.1.1 Sand cast iron S&S as per IS-1729 |
| 60 | 100mm x 75mm ( one hundred ten milimetre into seventy five milimetre |
| 61 | Providing and fixing P.V.C low level flushing cistern with manually controlled device ( handle lever) conforming to IS:7231, with all fitting and fixtures complete17.18.1 10 ltr. Capacity- White |
| 62 | Providing and fixing wash basin with C.I. brackets ,15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittingsand brackets, cutting and making good walls wherever require 17.7.3 White Viterous China Wash basin size 550x400mm with a pair of 15mm C.P. brass pillar taps |
| 63 | Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.c waste fitting complete17.28.1.117.28.1.1 32mm dia |
| 64 | 32mm dia. |
| 65 | Providing and fixing 100mm sand cast iron grating for gully trap |
| 66 | 100mm ( one hundred milimetre) nominal dia |
| 67 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. Waste fittings complete. 17.28.2.117.28.2.1 32mm dia |
| 68 | Providing and fixing G.I. Inlet connection for flush pipe with W.C. pan includingcarriage of materials within all leads and lifts and other incidentials |
| 69 | 17.73.1 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms |
| 70 | Providing and fixing 600x120x5 mmglass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long scews, rawl plugs etc. Complete |
| 71 | Providing and fixing toilet paper holder17.34.2Viterous china |
| 72 | Providing and fixing PTMT liquid soap container 109mm wide , 125mm high amd 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour , weighing not less than 105gms |
| 73 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS :8931: 18.49.115mm nominal bore |
| 74 | Providing and fixing C.P. brassLONG BODY bib cock of approved quality conforming to IS Standards and weighing not lessthan 650gms.18.51.115mm nominal bore |
| 75 | Providing and fixing C.P. Brass stop cock(concealed) of standard design and of approved make conforming to IS:8931.18.52.1 15mm nominal bore |
| 76 | Providing and fixing C.P.BRASSextension nipple ( size 15mmx50mm) of appproved make and quality as per direction of Engineer-in- charge |
| 77 | Providing and fixing required stainless steelfitting of press design of grade AISI 304 conforming to JAWA G116 standard with V -profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. |
| 78 | 18.90.1For 15.88mm outer dia pipe |
| 79 | 18.90.2 for 22.22mm outer dia pipe |
| 80 | 18.48A Providing and fixing rectangular high density polythylene water storage loft tank with cover, conforming to IS:12701, colour of opaque white or as approved by Engineer-in-Charge. The rate includes making necessary holes for inlet, outlet & fixtures for tank shall be paid separately. 500 *8.80= 4400 each |
| 81 | Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete including carriage of materials within all leads and lifts and other incidentials |
| 82 | i) 100mm ( one hundered milimetre) dia |
| 83 | ii) 75mm dia |
| 84 | Providing and fixing PVC collars |
| 85 | i) 100mm dia. |
| 86 | ii) 75mm dia |
| 87 | Providing and fixing soil.waste and vent piopes : |
| 88 | 100mm 17.35.1.1 Sand cast iron S&S pipe as per IS:1729 |
| 89 | 75mm Sand cast iron S&S pipe as per IS :1729 |
| 90 | 17.37) Proving and fixing M.S. holder- bat clamps of approved design to sand cast iron/cast (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 complete incliding carriage of materials within all leads and lifts and other incidentials |
| 91 | 17.37.1) for 100mm dia. Pipe |
| 92 | 19.30) constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand ) C.I. cover with frame (light duty) 455x610mm inetrnal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15kg), R.C.C Top slab with 1:1.5:3 mix ( 1 cement1.5 Fine sand:3 graded stone aggregate 20mm nominal size0. inside palstering 12mm thick with cement mortar 1:3 ( 1cement :3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc.complete as pere standard design |
| 93 | 19.30.1inside dimensions 455x610mm and 45cm deep for single pipe line |
| 94 | 19.30.1.1 With common burnt clay F.P.S.( non modular) bricks of class designation 7.5 |
| 95 | Providing and fixing stainless steel A ISI 204 (18/8) Kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40mm including paintaing of fitting and brackets, cuttting and making good walls wherever required :17.102.1.17.10.2.1 610x510 mm bowl depth 200mm |
| 96 | Septic Tank |
| 97 | Earth work in rough excavation, banking excavated each in layers not exceeeding 20cm in depth, breaking clods, watering , rolling each layer with 1/2 tonne roller or wooden or steel rammers and rolling every 3rd and top- most layer with power roller of minimum 8 tonnes and dressing up in embarkment for roads, flood banks, marginal banks and guide banks pr filling upn ground depressions, leads upto 50m and lift upto 1.50 mtrs. All kinds of soil |
| 98 | Providing and laying is position cement concrete of specifiied grade excluding the cost of centering and shuttering-All work up to plinth level:1:5:10(1 cement:5 fine sand : 10 graded stone aggregate 4mm nominal size |
| 99 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS:2222 in superstructure above plinth level up to floor five level in cement mortar 1:6(1 cement:6 coarse sand) :6.3.1 With F.P.S.(non modular)bricks |
| 100 | providing form work centering and shuttering including strutting . Propping etc and removal of form fom: |
| 101 | xx) Suspended floors ,roofs,landing ,balconies and access platform with water proof ply 12mm thick |
| 102 | iii)Reinforced cement concrete work in beams,suspended floors, roofs having slope up to 15* landings, balconies, shelves, chajjas, lintels,bands, plain window stills, staircases and sprial stair cases above plinth level up to floor five level, excluding the cost of centering shuttering,fishing and reinforcement with 1:1:5:3 (1 cement: 1:5n coarse sand) : 3 graded stone aggregate 20mm nominal size). |
| 103 | i) Suspended floors, roofs,landings,shelves and their supports balconies, beams,griders, breassumers and cantiliver upto all floor level |
| 104 | Steel reinforce for R.C.C. work including straightening, cutting, bending, placing in poaition and binding all complete upto plinth level .ii) Hard Draw steel wire. |
| 105 | i) Cement concrete flooring 1:2:4 (1 Cement: 2 coarse sand : 4 graded aggregate ) fishing with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 40mm thick with 20mm nominal size stone aggregate. |
| 106 | 15 mm cement plaster on the rough side of single or half brick waall of mix:13.2.11:4 (1 cement : 4 fine sand) |
| 107 | Boulder / slope filling tightly dry hand packed under floor as per specification or as per direction of the Engineer-in - Charge within all leads, lifts and other incidentials including carriage of material |
| 108 | site development & boundary wall |
| 109 | Earth work in excavation by mechanical means ( hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan), including dressing of sides and ramming of bottoms , lift upto 1.4m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m 2.6.1 All kinds of soil |
| 110 | Providing centering and shuttering including strutting,propping etc. and removal of form work for foundation ,fottings, bases for columns etc. for mass concrete |
| 111 | Providing and laying in position cement concrete of specified grade excluding the cost of centereing and shuttering - All work upto plintj level:4.1.11) 1:5:10 (1 cement:5 Fine:10 graded stone aggregate 40mm nominal size) |
| 112 | Brick work with common burnt clay machine moulded oerforated bricks of class designation 12.5 conforming to IS:2222 in superstructure above plinth level upto floor five level in cement mortar 1.6 (1 cement : 6 coarse sand) : 6.4.2 with F.P.S (NON MODULAR) bricks |
| 113 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level.6.12.1 Cement mortar 1:4 (1 cement:4 coarse sand) |
| 114 | 15mm cement plaster on the rough side of a single or half brick wall of mix :13.2.11:4 (1 cement: 4fine sand) |
| 115 | Finishing walls with water proofing cement paint of required shade :13.44.1 New work(Two or more coats [email protected]/10Sqm) |