Construction Of Veterinary College, R.K. Nagar, West Tripura Sh. Vertical Extension Of Administrative Cum Academic Building ( 3Rd Phase Part Of Third Floor ) Building Portion Including Internal Water Supply And Sanitary Installations.
Tender Overview
Project Description
Construction Of Veterinary College, R.K. Nagar, West Tripura Sh. Vertical Extension Of Administrative Cum Academic Building ( 3Rd Phase Part Of Third Floor ) Building Portion Including Internal Water Supply And Sanitary Installations.
BOQ
| Sl. No. | Item Description |
| 1 | SUB-HEAD : EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | SUB-HEAD : CEMENT CONCRETE WORK |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shutteringAll work upto plinth level: |
| 5 | (i) 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | (ii) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded stone aggregate 40 mm nominal size) |
| 7 | SUB-HEAD : RCC WORK |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- |
| 9 | (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- |
| 11 | (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with |
| 13 | (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 15 | (i) Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 16 | Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits |
| 17 | (i) 50 mm thick |
| 18 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement : 2 coarse sand), including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Centering shuttering including struttings, propping etc. and removal of form work for: |
| 20 | (i) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
| 21 | (ii) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 22 | (iii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 23 | (iv) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 24 | (v) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards. |
| 25 | (vi) Edges of slabs and breaks in floors and walls under 20 cm. wide |
| 26 | (vii) Weather shade, Chajjas, corbels etc., including edges. |
| 27 | SUB-HEAD : BRICK WORK |
| 28 | First class brick work in foundation and plinth including cost of all materials as required complete. |
| 29 | (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 30 | (ii) In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 31 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete. |
| 32 | (i) In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 33 | Half brick masonry with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- |
| 34 | (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 35 | Extra for providing & placing in position 2 nos 6mm dia MS bars at every 4th course of half brick masonry work including anchorage in joints of 75mm in each side in superstructure for all level including cost of all materials as required complete:- |
| 36 | (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 37 | SUB-HEAD : CLADDING WORK |
| 38 | Providing and fixing gang saw cut of approved thickness mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 ( 1 cement : 4 fine sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing , curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels:- |
| 39 | (i) 18 mm thick Rajnagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly approved:- - Area of slab upto 0.50 sqm. |
| 40 | (ii) 18 mm thick Granite of any colour and shade duly approved. - Area of slab upto 0.50 sqm. |
| 41 | Providing edge moulding to approved thickness marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete at all levels as required as per design approved by the Engineer-in-charge:- |
| 42 | (i) 18 mm thick Granite work. |
| 43 | Providing and fixing stone slab with table rubbed, edges rounded and polished of size 75x50 cm deep and approved thickness fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth including rubbing, curing etc. complete at all levels as required (measurement should be of exposed finished work):- |
| 44 | (i) White Agaria Marble Stone of approved shade of 18 mm thick (75 x 50 cm). |
| 45 | SUB-HEAD : WOOD WORK |
| 46 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : |
| 47 | (i) Local Teak wood |
| 48 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. |
| 49 | (i) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 50 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. |
| 51 | (i) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 52 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 53 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 54 | (i) 300 x 16 mm |
| 55 | (ii) 250 x 16 mm |
| 56 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 57 | (i) 300 x 10 mm |
| 58 | (ii) 250 x 10 mm |
| 59 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 60 | (i) 125 mm |
| 61 | (ii) 100 mm |
| 62 | Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. |
| 63 | (i) Single rubber stopper |
| 64 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 65 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in- charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 66 | Providing 50 × 50 × 50 mm Gamair wood plugs including cutting brick work and fixing in cement mortar 1:3 (1 cement: 3 fine sand) and making good the walls etc. |
| 67 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 68 | Providing and fixing in position wall panelling at all heights with 12.5 mm thick Perforated Gypsum Board panels/tiles made from plasterboard having glass fibreconforming to IS: 2095 part I, of size 595 x 595mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, having NRC (Noise Reduction coefficient) of 0.65 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel |
| 69 | size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Resin bonded Glasswool of 24kg/m³ and 50mm thickness is then to be inserted in the slots and finally GypsumBoardnon combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing compound and fiber joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturer\"s specification as per direction of Engineer-in-Charge all complete. |
| 70 | SUB-HEAD : STEEL WORK |
| 71 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast /anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required. |
| 72 | Providing and fixingfan clamp type-Iof 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete. |
| 73 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 74 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 75 | (i) Hot finished welded type tubes |
| 76 | SUB-HEAD : ALUMINIUM WORK |
| 77 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :- |
| 78 | (i) For fixed portion of approved quality:- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 79 | (ii) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- - Anodisedaluminium(anodisedtransparentordyedto requiredshadeaccordingtoIS:1868,Minimumanodic coating of grade AC 15). |
| 80 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- |
| 81 | (i) With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 82 | (ii) With float glass panes of 5.5 mm thickness ( weight not less than 13.50 kg / sqm ) |
| 83 | Providing and fixing stainless steel (SS 304 grade) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-in-charge:- |
| 84 | (i) 255 x 19 mm |
| 85 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. of approved quality completeas per direction of Engineer-in-charge:- |
| 86 | (i) Anodised aluminium of grade AC 15. |
| 87 | Providing and fixing 100 mm brass locks ( best make of approved quality ) with 6 levers without pair of handles for aluminium doors including necessary cutting and making good etc. completeas per direction of Engineer-in-charge. |
| 88 | SUB-HEAD : FLOORING AND SKIRTING WORK |
| 89 | Providing and fixingMarble stone in floors over 20 mm thick bed ofcement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointing with white cement mixed with of matching shade, including rubbing and polishingcomplete. |
| 90 | (i) 18mm thick Marble Stone - Rajnagar plain marble |
| 91 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 92 | (i) 8mm thick Rajnagar marble tiles (polished) |
| 93 | Providing and laying cement concrete 1:2:4 (1 cement: 2 fine sand : 4 graded well burnt brick aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips and cost of glass strips etc. complete. |
| 94 | (i) 40 mm thick |
| 95 | Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) ofapproved make in all colours, shades of any size asapproved by Engineer-in-charge in skirting, risers ofsteps and dados, laid over 12 mm thick bed of cementmortar 1 : 3 (1 cement : 3 fine sand) jointed withordinary cement slurry including pointing with whitecement mixed with pigment of matching shade complete. |
| 96 | Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete. |
| 97 | (i) Mat Finish Tiles - Ceramic Tiles 1st quality 400 x 400mm in all shades and designs |
| 98 | (ii) Anti-Skid Tiles - Ceramic Tiles 1st quality 400 x 400mm in all shades and designs |
| 99 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 100 | (i) Double charged Stainfree vitrified tiles - Size of tile 60 x 60 cm |
| 101 | Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer-in- Charge. |
| 102 | 80 mm thick factory made c.c.interlockingpaver block of M-35 GradeProviding and laying factory made chamfered edge Cement Concrete paver blocks of required strength, thickness & size/ shape, made by table vibratory method to attain superior smooth finish using PU or equivalent moulds, laid in required grey colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks, lawns, drive ways or light traffic parking etc. all complete as per specifications & approval/ direction of the Engineer -in-Charge:(a) 80 mm thick c.c. paver block of M-35 grade with approved colour, design and pattern. |
| 103 | SUB-HEAD : ROOFING AND CEILING WORK |
| 104 | ProvidingcorrugatedG.S.sheetroofingincludingvertical/curved surface fixedwithpolymercoatedJorLhooks,bolts andnuts8mm diameterwithbitumenandG.I.limpetwashersorwithG.I.limpet washersfilledwithwhiteleadandincludingacoatofapprovedsteel primerandtwocoatsofapprovedpaintonoverlappingofsheets complete(uptoanypitchinhorizontal/verticalorcurvedsurfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 105 | (i) 0.63mm thick with zinc coating not less than 275gm/m2 |
| 106 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with |
| 107 | connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sidesof joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :(i) 12.5 mm thick tapered edge gypsum moisture resistant board. |
| 108 | ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes (working pressure 4 kg/cm2)conformingto IS : 13592 Type Aincludingjointingwith sealring conformingtoIS:5382leaving10mmgapforthermalexpansion: |
| 109 | (i) Single socketed pipe - 110 mm OD |
| 110 | Providingandfixing on wallface unplasticised - PVCmouldedfittings/ accessoriesfor unplasticised Rigid PVC rain water pipes conforming to IS:13592TypeAincludingjointingwith sealringconformingtoIS: 5382 leaving 10 mm gap forthermalexpansion: |
| 111 | (i) Coupler - 110mm |
| 112 | (ii) Single equal tee without door - 110 x 110 x 110 mm |
| 113 | (iii) Single equal tee with door - 110 x 110 x 110 mm |
| 114 | (iv) Bend 87.5 - 110mm |
| 115 | (v) Plain shoe - 110 mm |
| 116 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete. |
| 117 | (i) 110mm |
| 118 | Providing and fixing to the inlet mouth of rain water pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. complete. |
| 119 | (i) 100mm |
| 120 | SUB-HEAD : FINISHING WORK |
| 121 | 12 mm cement plaster of mix |
| 122 | (i) In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 123 | (ii) In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 124 | 15 mm cement plaster on the rough side of single or half brick wall of mix: |
| 125 | (i) In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 126 | 6 mm cement plaster of mix: |
| 127 | (i) In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) |
| 128 | Neat cement punning. |
| 129 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 130 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :(i) New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 131 | Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :(i) New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 132 | Applying priming coat: [Payment shall be made after submission of Test Certificate issued by the Manufacturer] |
| 133 | (i) With ready mixed pink primer of approved brand and manufacture on wood work ( hard & soft wood ). |
| 134 | (ii) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 135 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: (i) Two or more coats on new work |
| 136 | SUB-HEAD:DISMANTLING AND DEMOLISHING WORK |
| 137 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:- |
| 138 | (i) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 139 | Extra for scrapping, cleaning and straightening reinforcement obtained from RCC or R.B. worketc. complete as per direction of the Engineer- in-charge. |
| 140 | SUB-HEAD : SANITARY WORKS |
| 141 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 142 | (i) White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 143 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 144 | (i) W.C. pan with ISI marked white solid plastic seat and lid |
| 145 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 146 | (i) Range of three urinal basins with10 litre white P.V.C. automatic flushing cistern. |
| 147 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. |
| 148 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings: |
| 149 | (i) Flat back wash basin of size 550x400mm. |
| 150 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 151 | (i) Kitchen sink without drain board - 610x460 mm bowl depth 200 mm. |
| 152 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 153 | (i) Semi rigid pipe - 32 mm dia |
| 154 | (ii) Flexible pipe -32 mm dia |
| 155 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 156 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 157 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms |
| 158 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. |
| 159 | (i) 450mm long towel rail with total length of 495mm, 78mm wide and effective height of 88mm, weighing not less than 170gms |
| 160 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
| 161 | Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) including necessary plaster and pointing in cement mortar 1:4(1cement: 4 coarse sand): |
| 162 | (i) 100 mm dia. |
| 163 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382leaving10mmgapforthermalexpansion: |
| 164 | (i) Single socketed pipe- 110 mm OD |
| 165 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap forthermalexpansion: |
| 166 | (i) Coupler - 110mm |
| 167 | (ii) Single pushfit Coupler - 110mm |
| 168 | (iii) Single equal tee without door - 110 x 110 x 110 mm |
| 169 | (iv) Single equal tee with door - 110 x 110 x 110 mm |
| 170 | (v) Doubleequal junction of required degreewithout door - 110 x 110 x 110 mm |
| 171 | (vi) Doubleequal junction of required degreewith door - 110 x 110 x 110 mm |
| 172 | (vii) Bend 87.5 - 110mm |
| 173 | (viii) Plain shoe - 110 mm |
| 174 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVCrainwater, soil, waste & vent pipesbymeansof50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work andfixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.(i) 110 mm |
| 175 | SUB-HEAD : WATER SUPPLY |
| 176 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. - Internal work -Exposed on wall |
| 177 | (i) 15 mm nominal outer dia .Pipes. |
| 178 | (ii) 20mm nominal outer dia .Pipes. |
| 179 | (iii) 25mm nominal outer dia .Pipes. |
| 180 | (iv) 32mm nominal outer dia .Pipes. |
| 181 | (v) 40mm nominal outer dia .Pipes. |
| 182 | (vi) 50mm nominal outer dia .Pipes. |
| 183 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. - Concealed work including cutting chases and making good the walls etc. |
| 184 | (i) 15 mm nominal outer dia .Pipes. |
| 185 | (ii) 20 mm nominal outer dia .Pipes. |
| 186 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. - External work |
| 187 | (i) 15 mm nominal outer dia .Pipes. |
| 188 | (ii) 20 mm nominal outer dia .Pipes. |
| 189 | (iii) 25 mm nominal outer dia .Pipes. |
| 190 | (iv) 32 mm nominal outer dia .Pipes. |
| 191 | (v) 40 mm nominal outer dia .Pipes. |
| 192 | (vi) 50 mm nominal outer dia .Pipes. |
| 193 | Providing and fixing brass bib cock of approved quality : |
| 194 | (i) 15 mm nominal bore |
| 195 | Providing and fixing brass stop cock of approved quality : |
| 196 | (i) 15 mm dia nominal bore |
| 197 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): |
| 198 | (i) 25 mm nominal bore |
| 199 | (ii) 40 mm nominal bore |
| 200 | Providing and fixing gun metal non-return valve of approved quality (screwed end): |
| 201 | (i) 25 mm nominal bore - Vertical |
| 202 | (ii) 40 mm nominal bore - Vertical |
| 203 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 204 | Constructing masonry Chamber 30x30x50 cm, inside , in brick work in cement mortar 1:4 (1 cement :4 fine sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarse sand) 12mm thick finished with a floating coat of neatcementcompleteasper standard design : |
| 205 | (i) With Second Class bricks |
| 206 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: |
| 207 | (i) 100 mm diameter |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender