Providing Functional Household Tap Connection ( Fhtc ) From Existing Distribution System Within The Command Area Of Nandai Piped Water Supply Scheme At Opposite Site Of Railway Track At Kalna-I Block Under Burdwan Division, Phe Dte.
Tender Overview
Project Description
Providing Functional Household Tap Connection ( Fhtc ) From Existing Distribution System Within The Command Area Of Nandai Piped Water Supply Scheme At Opposite Site Of Railway Track At Kalna-I Block Under Burdwan Division, Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Providing FHTC from the existing CI/DI/UPVC/HDPE/GI/AC distribution pipeline by installing 10mm NB Gun-metal Ferrule conforming to IS 2692:1989 with latest amendments on the said pipeline with supply, fitting & fixing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc. and supply & laying of 15mm NB PVC (SCHEDULE 80)/20mm OD HDPE (PE100, PN16)/20 mm OD PPR-C (Class - SDR7.4/PN16) pipes upto required length with all necessary specials 1.0 metre below the ground connecting the ferrule including cutting trenches in all sorts of soil and filling up trenches as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by EIC. Supply and installation of a 15 mm. dia. alloy iron Bib Cock (tested to 21kg/cm2) above 1.0 mtr. from ground,an alloy Stop Cock of 15mm. dia. with brass spindle (tested to 21kg/cm2) to be fitted in a position as directed by EIC. GI pipe (medium duty) of 2 mtr. length with all necessary specials to continue from the end of the HDPE/PVC/PRC-C pipe and up to 1.0 mtr. above ground with in the premises of household.Note : 1. PVCpipe shall of Schedule 80 (medium duty) conferming to ASTMD - 1785 and threated to match with GI pipeas per IS: 1239 (Part-I). 2. Rate is exclusive of supply and deleveriy of 10 mm. NB gun-metal ferrual. Supply and lying of 15mm NB PVC (SCHEDULE 80)/20mm OD HDPE (PE100, PN16)/20mm OD PRC-C (Class-SDR7.4/PN16) pipes. |
| 2 | a) Upto 10m length. |
| 3 | b) Above 10m upto 20m length. |
| 4 | Collection of house hold details at prescribed format through mobile app / hard copy including geo reference as directed by EIC and submission of the same to PHE Dte in soft copy. |
| 5 | Bituminous pucca road (approx. 450 mm. depth) cutting by using gaiti, chisel, hammer etc. and picking up the withdrawing excavated materials and remove the same within distance of 30 Mtr. at least all complete for fixing / crossing all dia. of pipeline as per direction of EIC. Considering 15% of total number of house connection with having 150 mm. width. |
| 6 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roof. Considering 60% of proposed extension of uPVC pipeline. |
| 7 | (a) upto 150 mm. thick |
| 8 | Cost for boring any type of soil by augor boring (horizontal) with water jet system including hire charges of machine, tools & plants, all complete with all labour and supply of water etc. as per specification and direction of EIC. |
| 9 | i) 80mm to 100mm dia. |
| 10 | Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earthwork in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority willbe borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/ approvedbrand solvent cement (asperIS: 14182-1994 including cost of all fabricated PVC fitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C.N.B. i) Manufacturer\"s test certificate for UPVC pipe & specials to be produced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii)No part payment at any stage on account of supply of materials shall be entertained. iv)Payment will be made on actual consumption of materials. v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. (A) Pressure Rating : Class - Ill (i) Laying of pipe line including cost of pipe & fittings / specials but excluding cost of vlaves |
| 11 | 50mm(OD) |
| 12 | 63mm(OD) |
| 13 | 75mm(OD) |
| 14 | 90mm(OD) |
| 15 | Construction of different dia Sluice Valve/Air Valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt. approved drawing with 25cm thick brick work (1: 6) over cement concrete (4:2:1) over a single B/F soling over 150mm thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified ] |
| 16 | 100mm dia. |
| 17 | 150mm dia. |
| 18 | Supply and delivery of CIDF sluice valve (Special type) PN-1.00 of differntdia make with C.I double flanged no0n rusting spindle sluice valves conforming to IS: 14846-2000 with latest emended having body dome/bonnet and cover of C.I.Gr.-F.G 210mtr. spindle of IS 6603 G.R-12/Gr-13 non -magnetic, nuts seat rings aew of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS: 1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2 N.B: The above item should be procured from the reputed manufactures as per deptt.approved vender list. |
| 19 | 100mm dia. |
| 20 | 150mm dia. |
| 21 | Making flange joint to CIDF pipe, Specials, valves etc. with supply of necessary nuts and bolts,rubber insertion of 6kg/m2 (3mm gauge) and materials required including dewatering if any tools and plants, labour cost etc. as per specification and direction of EIC .( Nut and bolts shall be of TATA/GKW make) |
| 22 | 100mm dia. |
| 23 | 150mm dia. |
| 24 | Making Village road (average 3m width) crossing by horizontal auger boring for accomodation of laying of average 3(three) nos. 15mm dia GI pipes for FHTC or as per direction of Engineer-in Charge. Considering 10% of Total Number of House Connection with each having 3 mtr. length. |
| 25 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if ecessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel |
| 26 | I. SAIL/ TATA/RINL |
| 27 | (A) Filling in foundation or plinth by silver sand in layer not exceeding 150mm as directed and consolidating the same by through saturation with water ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 28 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 29 | Brick work with 1st class bricks in cement mortar (1:6) |
| 30 | (a) In foundation and plinth |
| 31 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (Avg.distance 55 km.) a) Pakur Variety |
| 32 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(Avg.distance 55 km.) |
| 33 | (i) Pakur Variety |
| 34 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar |
| 35 | (a) 15 mm thick plaster |
| 36 | Add 12% GST [For Sl. No. 01 to 17] |
| 37 | Add 1% Cess [For Sl. No. 01 to 17 + 18] |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents