Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur. Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur., udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur. Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur.. Submission Date for this Tender is 14-03-2022. Air Conditioner Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

31086104
Corrigendum : Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur. Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur.
Open Tender
Indian
Jammu And Kashmir
udhampur
14-03-2022

Tender Details

Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur. Repair/Maintenance Of Ac Plants, Cooling Towers, Refrigeration Section And Summer Appliances Under Ge (Utilities) Udhampur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 84800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/Maintenance of AC plants, cooling towers, refrigeration section and summer appliances under GE (Utilities) Udhampur.
Sl. No. Item Description
1Repair/Servicing ofcooling tower ofAC plantFRP type by dismantling and taking out thehoney comb PVC fills complete and PVC nozzles, descaling the PVC fills by suitable descaling solution including brushing and cleaning complete with cleaning solution and water, replacing the defective PVC filling, cleaning the nozzles and replacing the defective PVC flange alongwith rubber gasket, rusted bolts, nuts and washers etc, cleaning the water sump and XPM wire mesh with suitable cleaning solution re-assembling the same including replacing the defective water filterflanges of pipe joints etc and testing complete all as specified and directed by Engr-in-Charge. Note: PVC Fills will be measured and paid separately
2Servicing of 3 Noscompressorcapacity upto 7.5 TR unitby draining out the used compressor oil, opening both side covers, head covers and taking out the defective oil filter, cleanings the sump by using suitable cleaning solution, replacing the defective oil filter element, checking of suction and discharge valves, adjust them and refixing the side covers, head covers including replacing the suitable gaskets complete and re-filling of new compressor oil to the required level, removing the pully, checking the serviceability of shaft sealassy, replacement of shaft seal assly and refixing the pully including replacing the defective gas filter and testing complete all as specified and directed by Engr -in-Charge. Note: Oil filter element, gas filter and shaft seal will be measured and paid forseparately.
3Cleaning the external surfaces of equipment/accessories of central AC plant 5/7.5 TRcapacityand painting with two coats of synthetic enamel paint of existing colour including writing SM/MES No, marking flow direction, set Nos etc complete all as specified and directed by Engr-in-Charge.Plant comprising of following :-- (a) Induction motor - 11 KW - 3 Nos. (b) Condenser - 3 Nos. (c) Compressor Unit 5 TR - 3 Nos. (e) Condenser pump set - 2 Nos. (f) LT controlpanel board cubical type - 1 No. (g) Cooling towerfor 5 TR - 1 No. (j) Condenser line pipeing. (k) AHU units and complete piping etc.
4Supply only compressor oil in sealed container manufactured by Hindustan Petrolium Limited as per site requirement or equivalent complete all as specified and directed by Engr-in-Charge.
5Repair/Replacement of5 TR compressor for air - Cooled ductable package unitsHermetic Scroll Compressors and Microprocessors control panel,high pressure low pressure cut out, temperature control device of the following Nominal complete all as specified and directed by Engr-in-Charge.
6Unloading, Lifting, Shifting,and placing at foundation including valve Installation, Testing and Commissioning of Air Cooled, Ductable units of 5TR capacity complete all as specified and directed by Engr-in-Charge.
7Repair/Replacement of ducting made out of GI Sheet of 22 gauge in replacment of the burnt out parts of ducting complete all as specified and directed by Engr-in-Charge.
8Repair/Replacement of Acoustic Lining with 25mm thick fiber glass wool with tissue paper and 28g perforated aluminium sheet in supply air ducts complete all as directed by Engr-in-Charge.
9Repair/Replacementof 32mm PVC drain pipe line including clamps with accessories complete all as specified and directed by Engr-in-Charge.
10Repair/Replacementof flexible double canvas connection complete all as specified and directed by Engr-in-Charge.
11Copper Refrigerant Piping ofsize 1/8 complete all as specified and directed by Engr-in-Charge.
12Copper Refrigerant Piping of size 7/8 complete all as specified and directed by Engr-in-Charge.
13Four single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 2.5sqmm size in ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed byEngr-in-Charge.
14Four single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 4sqmm size in ISI marked with 4sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed byEngr-in-Charge.
15Four single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 4sqmm size in ISI marked with 6 sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
16Repair /Replacement of burntHeatingstrip heater capacity 3kwwith pan type humidifer all controls. Heating thermostat, humidity stat etc., complete all as specified and directed by Engr-in-Charge.
17Dismantling and taking out of old unserviceable LT Panel for 5/7.5 TR at 1FODand CHNC and supply, installing and testing LT indoor type weather proof panel floor mounted on equal angleCRCA steel sheet dust and vermin proof duly powder coated and wired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI similar design and technology shall be adopted for fabrication of panel,size of panel length 1875mm,Height 3000mm,Depth 400mm,sheet will be1.6mm. Copy of CPRI test report shall be produced to GE along with the certificate from manufacturer of the panel that the similar design and standard have followed in these panels.The panel shall be comprising of following accessories complete all as specified and directed by Engr-in-Charge.
18(a) MCCB 100Amps, 4 pole, 35kA, 415 volts - 01 No. (b) Copper bus bar 4 strip as perrating 800amp -01 Set. (c) MCB 6A SP 10KA - 03Nos. (d) MCB 6A TP 10KA - 03No. (e) Over load relay range 0.45-0.75A -03Nos. (f) Control Terminal 10A - 10Nos. (g) MCCB 32A TP -03Nos. (h)Digital meter-01 Set (i)CT"S 100/5 -03 Nos (j) Phase indicator for three phase (RYB) -01 Set (set of three). (k) 0.5 HPDOL Starter. 3Nos (MCB 6A TP 10KA, Over load relay 0.45-0.75A, Contactor 9A, Add -ON block2NP-2NC, Indicator on /off/Trip,Push buttonStart/Sop,MCB 6A SP 10KA,Selector switch A/M. Single phase preventor IC/O ,power terminal 20A, Control terminal 10A with complete accessories.
19(l) 3 HPDOL Starter 3Nos(MCB 10A TP 10KA, Over load relay 0.3.5-0.4.5A, Contactor 12A, Add -ON block2NO-2NC, Indicator on /off/Trip,Push buttonStart/Sop,MCB 6A SP 10KA,Selector switch A/M. Single phase preventor IC/O ,power terminal 20A, Control terminal 10A)with complete accessories (m) 10 HP Star delta Starter 3Nos(MCB 25A TP 10KA, Over load relay 14-23A, Contactor 9A, Add -ON block2NO-2NC, Indicator on /off/Trip,Push buttonStart/Stop,MCB 6A SP 10KA,Selector switch A/M. Single phase preventor IC/O ,power terminal 20A, Control terminal 10A)with complete accessories. (n) 5HPDOL Starter3Nos(MCB 16A TP 10KA, Over load relay 6A-10A, Contactor 18A, Add -ON block2NO-2NC, Indicator on /off/Trip,Push buttonStart/Stop,MCB 6A SP 10KA,Selector switch A/M. Single phase preventor IC/O ,power terminal 20A, Control terminal 10A) with complete accessories. (i)Complete wiring of panel board withPVC insulated copper conductor multi- strand cable-01 Job (j)Blank space for MCCB of rating upto 100 Amps ,4 pole -01 No .
20Earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x6mm thick buried directly in ground ( earth pit not less than 2.25 metre of below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x6mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron, including PCC pit in PCC, M-15, type B-1 RCC covermade out of cement concrete, M-15, type B-1, (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, light grade protection pipe 40mm bore up to main board complete all as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge.
21Repair /Replacement of magnetic contactor 40amp, over load relay, single phase perventor panel for 7.5 and 5.5 TR AC plant complete all as specified and directed by Engr-in-Charge.
22Repair /Replacement of compressor for air cooled ductable package units with gas 407c Hermetic Scroll Compressors and Microprocessors control panel,high pressure low pressure cut out, temperature control device of the 7.5 TR nominal capacity complete all as specified and directed by Engr-in-Charge.
23Unloading, Lifting, Shifting,and placing at foundation including valve Installation, Testing and Commissioning of Air Cooled, Ductable units of 7.5 TR complete all as specified and directed by Engr-in-Charge.
24Supply and charging refrigerant gas R-22 complete all as specified and directed by Engr-in-Charge.
25Supply and charging refrigerant gas R-410 complete all as specified and directed by Engr-in-Charge.
26Taking out old existing unserviceable metal plugsocket and supply and fix new metal plug and socket board complete enclosure with single pole and neutral and earth plug with MCB SP 32/40 Apms, 220 Volts complete suitable for window/Split type complete all as specified and directed by Engr-in-Charge.
27Taking out old existing unserviceable front show grill and supply and fixnew front show grill for LG/Voltas /Sidwal/Godrejwindow type AC 1.5 Toncomplete all as specified and directed by Engr-in-charge (as per sample approved by GE).
28Taking out old existingreversible type unserviceableinner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split typeAC of capacity 1.5 /2.0Ton as existing shape, size and make complete all as specified and directed by Engr-in-Charge. Make : Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
29Taking out old existingreversible type unserviceable outer unit of split typeAC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split typeAC of capacity 1.5 /2.0Ton existing shape and size without compressor complete all as specified and directed by Engr-in- Charge. Make :Godrej, Carrier, Bluestar, Voltas.Hitachi.LG.
30Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 7.5KVA, 5KVA, 2KVA, 1KVA, 0.5KVA throughly checking, cleaning all parts by brushing and re-assembling afterrepalcement of required burnt unserviceable parts / componenets, testing and comminssioning complete after necessary repair/replacement of components as below:-
31Rewinding of main coil (primary/secondary) with super enameled copper wire of existing size including varnishing and insulation material of capacity 7.5KVA.
32Description all as per ser item No.28.01 here-in-before but for DG set of capacity 5KVA.
33Description all as per ser item No.28.01 here-in-before but of capacity 2KVA.
34Description all as per ser item No.28.01 here-in-before but of capacity 1KVA.
35Description all as per ser item No.28.01 here-in-before but of capacity 0.5KVA.
36Replacement of unserviceable relay for 7.5KVA & 5KVA,30amp 24volts DC.
37Replacement of unserviceable Step down transformer 24 volts 2Amp for 1 KVA & 7.5KVA.
38Replacement of unserviceable circuit plate with connection wire.
39Replacement of unserviceable relay for 0.5KVA, 1KVA & 2KVA,16amp 24volts DC.
40Replacement of unserviceable Voltmeter 0- 300V, AC 75 Sqm.
41Replacement of unserviceable Ampre meter 0- 30Amp, AC 75 Sqm.
42Replacement of unserviceable push switch.
43Replacement of unserviceable time delay circuit.
44Replacement of unserviceable connector switch 30amp 220volts AC.
45Replacement of unserviceable 3pin socket 5Amps,240volts.
46Replacement of unserviceable 3pin socket 15Amps,240volts.
47Water tap internal threaded /external threaded suitable for water cooler complete all as specified and directed by Engr-in - Charge.
48Taking out old existingunserviceablecooling coil and supply and fix new cooling coil of existing shape and sizesuitable for 1.5/2 Ton Split/Window type ACcomplete all as specified and directed by Engr-in-Charge.
49Taking out old existingunserviceablecondensing coil and supply and fix new condensercoil of existing shape and sizesuitable for 1.5/2Ton Split/Window type ACcomplete all as specified and directed by Engr-in-Charge.
50Repair/replacementPCB for LG /Voltas/Loyed/Hitachi/Godrejwindow type AC 1.5 ton / 2Ton capacity complete all as specified and directed by Engr-in-Charge.
51Repair/replacementPCB for LG /Voltas/Hitachi/Loyed/Godrej split type AC 1.5ton/2Ton cap complete all as specified and directed by Engr-in-Charge.
52Taking out old existingunserviceablecoilSenser and supply and fix newcoil senser of existing shape and sizesuitable for 1.5/2 Ton Split Type ACcomplete all as specified and directed by Engr-in-Charge.
53Taking out old existingunserviceable Senser andsupply and fix newsenser of existing shape and sizesuitable for 1.5/2 Ton Split Type ACcomplete all as specified and directed by Engr-in-Charge.
54Taking out old unserviceable blower andsupply and fix new blower(plastic body)of 1.5/2.0 Ton Split/Window type AC (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge.
55Supply and topping up of refrigerant gas R-22 in Split air conditioner of capacity 1.5/ 2TR complete all as specified and directed by Engr-in-Charge.
56Supply and topping up of refrigerant gas R-410 in Split air conditioner of capacity 1.5/ 2TR complete all as specified and directed by Engr-in-Charge.
57Supply and topping up of refrigerant gas R-600 in Referigerator complete all as specified and directed by Engr-in-Charge.
58Supply and topping up of refrigerant gas R-32 in Referigerator complete all as specified and directed by Engr-in-Charge.
59Supply and topping up of refrigerant gas R-134 in Water Cooler and Referigerator complete all as specified and directed by Engr-in-Charge.
60L -Shape thimble brass in pk(50Nos in one pkt)(in replacement) complete all as specified and directed by Engr-in- Charge.
61Thimble brass(50Nos in one pkt) (in replacement) suitable for all type of AC,Watercooler, Referigerator,Deep freezer in pkt complete all as specified and directed by Engr-in-Charge.
62Reverse cycle valve (in replacement) for window type AC/ Split Type AC of capacity 1.5 Ton /2.0 Ton including welding, brazing complete all as specified and directed by Engr-in-Charge.
63Flexible drain pipe for Window type/Split Type AC of any capacity complete all as specified and directed by Engr-in-Charge.
64Taking out old existingunserviceable oneand supply and fix new swing motor 0.3HP, 220 volts complete with Louvers, base ,clamps, nuts, bolts of size/shape suitable for 1.5/2.0 Ton Splt/window type AC of capacity 1.5 Ton complete all as specified and directed by Engr-in-Charge. Make:- LG/Voltas/Hitachi/Godrej.
65Taking out old existingunserviceable one and supply and fix newhermetic/Rotary sealed unit compressor(rotary type) suitable for window type/split type ACs of capacity 1.5 ton and making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as perlatest new model of same manufacturer with same specifications conforming to original compressor including rechargingwith refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal
66Taking out old existingunserviceable one and supply and fix newhermetic/Rotary sealed unit compressor (rotary type) suitable for window type/split type ACs of capacity 2 tonand making connection to suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as perlatest new model of same manufacturer with same specifications conforming to original compressor including rechargingwith refrigerant F-22 , Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and replacing parts with gas brazing and carryout leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system complete all as specified and directed by Engr-in-Charge. Make-LG/Godrej/Hitachi/universal
67Taking out old existingunserviceable one and supply and fix new hermitically /Rotary sealed unit compressor and making connection of suction and discharge pipe(after disconnecting of sealed unit).New sealed unit compressor should be of same make, capacity as per existing unitoflatest new model of same manufacture with same specification conforming to original compressor including rechargingwith refrigerant gas F-22/R-134A,R-600, Hydrocarbon Gas, replacement of copper tubing of existing size for suction and discharge and changing parts with gas brazing and leakage testing with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump and testing after installation in the system all as directed by Engr-in-charge for the following sealed units pertaining to Water coolers, refrigerator and deep freezers:-
68New sealed unit (compressor) in originalsuitable for Water cooler of capacity 40/80 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Blue Star /Voltas
69New sealed unit (compressor) in originalsuitable for Water cooler of capacity 60/120 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Blue Star /Voltas.
70New sealed unit (compressor) in originalsuitable for Water cooler of capacity 150/180 Ltr complete all as specified and directed by Engr-in-Charge. Make – Godrej / Voltas /Blure Star.
71New sealed unit (compressor) in original suitable for 165/170 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas.
72New sealed unit (compressor) in original suitable for 270 to 290 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas.
73New sealed unit (compressor) in original suitable for more than 310 Ltr Refrigerator, complete all as specified and directed by Engr-in-Charge. Make - Godrej /LG/Voltas
74New sealed unit (compressor) suitable for320 litres Deep Freezers in original, complete all as specified and directed by Engr-in-Charge. Make : Godrej /Voltas/Blue Star
75In replacement and testingof complete new Fan Motor1/16 HP single shaft for water cooler of same model and type, single phase 230V complete with base and clamps, nuts, bolts main lead as required etc against burnt defective motor complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
76Fan motor1/20 HP single shaft for water cooler as per the original make of fan motor complete all as specified and directed by Engr-in-Charge. Make: Air master /Crompton
77Fan Motor 1/35HP single shaft for water cooler complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
78Fan Motor 1/70HP single shaft for water cooler side holder, bushes with main lead complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton
79Fan motor with fan suitable for LG double door 286ltr / 310 Ltr refrigerators (in replacement) complete all as specified and directed by Engr-in-Charge.
80Fan motorof 165/170 Litre Refrigerator and supplyand fix new fan motorof existing make, shape and size (in replacement)directed by Engr-in-Charge.
81All as per Serial item No 63.00 here-in-abovebut suitablefor single door 310 litre Refrigerator complete all as specified and directed by Engr-in- Charge .
82Taking out old unserviceableCondensing coil for 165/170 to 310 Litre Referigeratorand supplyand fixnew condenser coilof existing make shape and size complete all as specified and directed by Engr-in-Charge.
83Fan Motor (in replacement) of same model and type, single phase 230V complete with base and clamps, nuts and bolts of suitable size etc. against burnt/ defective motorof capacity 1/8 HP double shaft for 1.5 /2.0 Tonwindow type AC including base, frame, side clamps complete all as specified and directed by Engr-in-Charge. Make: Air master/ Crompton.
84All as per Serial item No 66.00 here-in-before butBlower Fan Motorsingle shaft for Split type AC complete with base, clamps, side holders, rubber bushes complete all as specified and directed by Engr-in-Charge.
85All as per Serial item No 66.00 here-in-before Fan motor 1/7 HP for cooling coil of Split Type AC as per the original make of split type AC complete with base, frame, clamps, side holders, rubber bushes with main lead suitable for Voltas/ LG complete all as specified and directed by Engr-in-Charge. Make: Air master/Crompton.
86Taking out old existing unsv Starting Capacitor of capacity 50+6 mfd and supply and fixnew Multi purpose Running Capacitor of capacity 50+6mfd for window /split type AC complete all as specified and directed by Engr –in- Charge (as per sample approvedby GE).
87Taking out old existing unsv Starting Capacitor of capacity 120+150 mfd supply & fixnew Multi purpose startingCapacitor of capacity 120/150 mfd for window/split AC complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
88Taking out old existing unserviceable Starting Capacitor of capacity 40+80 mfd supply and fixnew Multi purpose startingCapacitor of capacity 40/80 mfd for water cooler complete all as specified and directed by Engr-in- Charge (as per sample approvedby GE).
89Taking out old existing unserviceable Starting Capacitor of capacity 40+60 mfd supply and fixnew Multi purpose startingCapacitor of capacity 40/60 mfd for water cooercomplete all as specified and directed by Engr-in- Charge (as per sample approvedby GE).
90Taking out old existing unserviceable Starting Capacitor of capacity 80/100mfd supply and fixnew Multi purpose Running Capacitor of capacity 80/100 mfd for water coolercomplete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
91Taking out old existing unserviceable Multi purpose running Capacitor of capacity 45+5 mfd and supply and fixnew Multi purpose running Capacitor of capacity 45+5 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
92Taking out old existing unserviceable Multi purpose running Capacitor of capacity 36+6 mfd and supply and fixnew Multi purpose running Capacitor of capacity 36+6 mfd for window /split type AC complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
93Taking out old existing unserviceable Multi purpose running Capacitor of capacity 10 mfd and supply and fixnew Multi purpose running Capacitor of capacity 10 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
94Taking out old existing unserviceable Multi purpose running Capacitor of capacity 4 mfd and supply and fixnew Multi purpose running Capacitor of capacity 4 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
95Taking out old existing unserviceable Multi purpose running Capacitor of capacity 20 Mfd and supply and fixnew Multi purpose running Capacitor of capacity 20 mfd for water cooler complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
96Taking out old existing unserviceable thermostateand supply and fix new thermostate for water coolerof any capacitycomplete all as specified and directed by Engr-in-Charge (as per sample approved d by GE).
97Taking out old existing unserviceable Fan Blade and supply and fixnew Fan Blade of 1.5/2ton window type ACof any capacitycomplete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
98Taking out old existing unserviceable Fan Blade and supply and fixnew Fan Blade of 1.5/2 ton split type ACof any capacitycomplete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
99Repair/replacement of water pump motor of desert cooler including electric connection and testing for better performance complete all as specified and directed by Engr-in-Charge.
100Replacement of "T" junction for desert cooler for watering the three side of the desert cooler with nozzels complete all as specified and directed by Engr-in-Charge.
101Replacement of Khas khas set for the doors of desert coolers all as directed by Engr-in-Charge.
102Servicing of window/split type air conditioner 1.5 TR capacities of any make by opening the indoor/ outdoor unit ,cleaning the air filter,condenserincluding complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water ,greasing fan motor ,rectification of loose electric connections andreplacement of u/s knobs of electrical items complete all as directedby the Eng-in-Charge.
103Disconnecting and taking down unserviceable overload/PTC relay for water cooler ,Deep freezer and referigerator and supply and fix new over load relay/PTC relay and testing for water cooler ,Deep freezer and referigeratorsatisfactory performance commissioningcomplete all as specified and directed by Engr-in-Charge.
104Disconnecting and taking down unserviceable thermostat from split type ACand supply and fix new thermostat for split type AC 1.5/ 2.0 Ton cap AC and testing the same for satisfactory performance complete all as specified and directed by Engr-in-Charge.
105Pressure testing and rectifying leakage in the system of window/splitair conditioner up to2 TR capacity including testing forsatisfactory performance, commissioning complete all as specified and directed by Engr-in-Charge.
106Copper tubing (in replacement) of existing size for suction and discharge and replacing parts with gas brazing and carryout leakagetesting with the help of halide torch, soap solution, vacuum pump and rebuilding of standard 800 PSI discharge pressure after creating vacuum with the help of vacuum pump complete all as specified and directed by Engr-in-Charge.
107Cleaning of coils of Window/Split by using alkaline based coil cleaner (Non Acid based) including taking down filters, spraying the diluted alkaline based coil cleaner, leaving it for five minutes and then flushing with running water. Fixing back the filters. Testing & re-commissioning etc.,complete all as specified and directed by Engr –in- Charge. Make: C-Shine
108Taking out old existing unserviceable Fan motor 4x4 and supply and fixnew Fan motor 4x4 for water coolerof any capacitycomplete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
109Sub main wiring(in replacement) with two single core PVC insulated, unsheathed copper conductor cable, 1100volts grade of size 4.0 sqmm, FRLS in and including concealed PVC conduit, heavy duty, ISI marked of dia 25mm and thickness not less than 2mm with all accessories such as bends, Tees, elbows, reducer socket, bell mouth,tube ends etc including cutting chases, pinning in masonry walling & making good to facing by pointing / plastering in cement mortar 1:3 to ends or edges for concealed wiring inculding 4.00 sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dollycomplete all as specified and directed by Engr-in- Charge.Note :- Two run of wire and single run of earth wire 1RM of PVC conduit shall be measured as one unit.
110Taking out old existing unserviceable diacharge valveand supply and fixnew discharge valve of 1.5/2 ton split type AC complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
111Taking out old existing unserviceable suctionvalveand supply and fixnew suction valve of 1.5/2 ton split type ACcomplete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
112Taking out old existing unserviceable bush and supply and fixnew bush of 1.5/2 ton split type ACmake LG/ Voltas complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
113Taking out old existing unserviceable filter drierand supply and fixnew drier ofSplit /Window 1.5/2.0 Ton Ac LG. Sidwal, Carrier and Voltas (as per sample approved by GE) complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
114Taking out old existing unserviceable capillary and supply and fixnew capillary of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approved by GE).
115Taking out old existing unserviceable dead Nut and supply and fixnew dead nut of 1.5/2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
116Taking out old existing unserviceable NRVand supply and fix new NRV of 1.5/2 ton split type /window type ACcomplete all as specified and directed by Engr-in-Charge (as per sample approvedby GE).
117Remote control unitSuitable for 1.5 / 2.0Ton split type ACworking on both (Hot & Cool) (in replacement) complete all as specified and directed by Engr-in- Charge (as per sample approved by GE) .
118Sub main wiring with two single core PVC insulated unsheathed copper conductor cable 1100 volts grade 6.0 Sq mm size HRFR in and including concealed PVC conduit heavy duty ISI marked 25mm dia non metallic with all accessories such as bends, Tees, elbows, reducer socket, bell mouth, tube ends etc. including cutting chases, pinning in masonry walling & making good to facing by pointing/plastering in cement mortar 1:3 to ends or edges for concealed wiring including4.0Sqmm PVC insulated copper conductor cable as earth lead to connecting to the earth dolly complete all as specified anddirected by Engr-in-Charge. Note :Two run of wire and single run of earth wire and 1 RM of PVC conduit shall be measured as one unit.
119Repair of Deep frezeer of capacity 320ltr capcity by dismantling the whole condensing as well as cooling coil and finding the leakage /damage portion. Rectify the leakage and damaged parts and vaccume leakage the whole system. Then charging the refrigerent Gas and confriming no leakage. Then reassembling the same deep freezer by providing proper insulation material at the disturbed area complete all as specified and directed by Engr-in-Charge.
120Repair /repalcement of broken /water leakage from connection of water cooler of capacity 40/80ltr to 150/150ltrs capcity by dismatiling the front sheet of thewater cooler tank, removing the thermocol sheet and doing necessary cutting /welding /brazing work to stop the leakage and make good the damaged portion and fixing of tap connection and reassembling the front sheet including providing the thermocol as a thermal insulation to the water coolers and testing the coolers for no leakage as complete allspecified and directed by Engr-in-Charge.
121Taking out & re-fixing after repair to roof/building at same location / other location including shifiting where required, of split /window/casttee type AC by making hole, drilling , cutting on wall and necessary gas pipe connection , electric connections and insulations complete all as specified and directed by Engr-in-Charge. Note:- All items including gas, copper pipe and electric cable if required will be measured and paid separately in relevent items of contract.
122Taking out okd existing unserviceable foam insulation and supply and fix new foam insulation of 1.5 /2 ton split type /window type AC complete all as specified and directed by Engr-in-Charge. (as per sample approved by GE).
123Supply and charging refrigerant gas R-410 complete all as specified and directed by Engr-in-Charge.