Design, Supply, Installation, Operation And Maintenance Of Scada System For Ujjain Water Supply System Design, Supply, Installation, Operation And Maintenance Of Scada System For Ujjain Water Supply System , Supply, Installation, Testing And Commissioning Including But Not Limited To, Safe Storage, Protection, Of Req Uired To Complete The Works In All Civil, Works, Erection, Testing And Commissioning Respects For The Following Instruments/ Equipment/Items As Per Specifications,Scope And As Per Direction Of Eic Complete In All Respect. , Scada In Ccc Comprising With Large Size Led Screen,Pc For Work Station ,Web Server,Histrorian Server, 2 Nos Web Client ,Ups With All Necessary Hardwares&Softwares Including Mobile Application Development As Per Indicative System Architecture , Plc Based Instrument Panel Complete With Ps, Input/Output Module ,Processor Etc With Hmi Suitable For Monitoring Motors,Flow,Pressure And Level Instruments & Mfm As Per Attached System Architecture, Scope And Specifications And As Per Direction Of Eic Suitable To Communicate With Centralized Integratedscada At Following Locations. , Intake Pump House At Gahughat , Intake Pump House At Ambodia , Intake Pump House At Sahibkheri , Intake Pump House At Undasa , Plc Based Instrument Panel Complete With Ps, Input/Output Module,Processor Etc With Hmi Suitable For Monitoring Motors,Flow,Pressure And Level And Water Quality Monitoring Instruments As Per Attached System Architecture, Scope And Specifications Complete In All Respect And As Per Directions Of Eic Suitable To Communicate With Centralized Integrated Scada At Following Locations. , Water Treatment Plant-1 At Gaughat , Water Treatment Plant-2 At Gaughat , Water Treatment Plant-3 At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Ph Analyser For Water Application At The Following Locations , Water Treatment Plants At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Turbidity Analyser For Water Application:At The Following Locations , Water Treatment Plants At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Chlorine Analyser For Water Application At The Following Locations , Water Treatment Plants At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Pressure Transmitter At The Following Locations , Intake Pump House At Gahughat , Intake Pump House At Ambodia , Intake Pump House At Sahibkheri , Intake Pump House At Undasa , Water Treatment Plants At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Over Head Service Reservoirs , Ultrasonic Level Transmitter At The Following Locations , Intake Pump House At Gahughat , Intake Pump House At Ambodia , Intake Pump House At Sahibkheri , Intake Pump House At Undasa , Water Treatment Plants At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Over Head Service Reservoirs , Loh Transmitter At The Following Locations , Water Treatment Plants At Gaughat , Water Treatment Plant At Ambodia , Water Treatment Plant At Sahibkheri , Water Treatment Plant At Undasa , Electromagnetic Flowmeter At Various Locations Of The Follow Sizes , 100 Mm , 150 Mm , 200 Mm , 300 Mm , 400 Mm , 450 Mm , 500 Mm , Remote Terminal Units (Rtu) For Ohsrs With 4 Analog Inputsfor Suitable Tocommunicate Signal To Ccc , Remote Terminal Units (Rtu) For Direct Supply Points With 1 Analog Inputsfor Suitable Tocommunicate Signal To Ccc , 3Cx 2.5Mm2 Xlpe/Pvc Insulated & Pvc Sheathed Armoured Control Cables Of 1.1 Kv Grade With Copper Conductor At Various Locations , 14Cx 1.5Mm2 Xlpe/Pvc Insulated & Pvc Sheathed Armoured Control Cables Of 1.1 Kv Grade With Copper Conductor At Various Locations , 2-Pair X 1Mm2. Stranded/ Flexible Annealede Bare Copper Conductor,Xlpe/Pvc Insulated Suitably Laid Up Together Overall Polyester Taped Al (Mylar Tape Wrapped) Along With Atc Drain Wire Overall Pvc Sheathed (St-1) Overall Screened Pair Armoured Instrumentation Cables At Various Locations , Perforated Cable Trays Of The Size Gi Of 100X50x1.6 Mm Including Horizontal And Vertical Bends, Reducers Tees,Cross Members And Other Accessories As Required , 8 Swg Copper Wire At 0.5 Meter Below Ground Level As Conductor Earth Electrode Including Soldering Etc. As Required. , Earthing Pits , Miscellaneous Items Like Modifications In Existing Starters,Repair Of Civil Works,Steel Etc Etc. Required To Complete The Works , Pilot Dma , D/F Di Pressure Reducing Wall In Pipeline Including Jointing Etc. Completer As Per Technical Specification And Direction Of Engineer In Charge. , 400 Mm Dia Electromagnetic Flowmeter At Inlet Of Dma , Remote Terminal Units (Rtu) For Direct Supply Points With 1 Analog Inputs For Suitable Tocommunicate Signal To Ccc , Pressure Transmitter At The Critical Measuring Points , 3Cx 2.5Mm2 Xlpe/Pvc Insulated & Pvc Sheathed Armoured Control Cables Of 1.1 Kv Grade With Copper Conductor , 2-Pair X 1Mm2. Stranded/ Flexible Annealede Bare Copper Conductor, Xlpe/Pvc Insulated Suitably Laid Up Together Overall Polyester Taped Al (Mylar Tape Wrapped) Along With Atc Drain Wireoverall Pvc Sheathed (St-1) Overall Screenedpair Armoured Instrumentation Cablesat Different Locations In Dma , House Service Connection: Making House Service Connection From Distribution Main To Property Limit Including (1) Providing And Fixing Brass Ferrule -1 No (2) Providing And Fixing Metal Inserted Compression Female Thread Adapter (3) Providing And Fixing Mdpe Blue Pipe Pe-80 And 16 Kg Class Confirming To Iso 4427 In Required Length -6 Meter Approx..(4) Providing And Fixing Compression Elbow -2 Nos (5) Providing And Fixing Pvc Ball Valve With One Side Compression And Another Side Female Threaded -1 No .The Work Shall Done As Per Detailed Specifications And As Per Drawings Complete With All Lead And Lift And As Directed By The Engineer (6) Providing, Installing And Giving Satisfactory Field Testing Of Amr Typewater Meter, Horizontal Inferential Multi-Jet Type With Magnetic Drive And Dry Dial Suitable For Ambient 50º C Temperature Duly Sealed Against Tampering Complete With Couplings At Both Ends And Conforming To Class B As Per Is 779/1994 (Vi Revision) With Isi Mark Along With Manufacturers Test Certificate And Guarantee Certificate, Including Cost Ofsurface Box For Water Meterandall Othermaterials And Labour Including Consumer Survey. , 15 Mm , 20 Mm , 25 Mm , 32 Mm , 8 Swg Copper Wire At 0.5 Meter Below Ground Level As Conductor Earth Electrode Including Soldering Etc. As Required. , Earthing Pits , Miscellaneous Items Like Modifications In Existing Starters,Repair Of Civil Works,Steel Etc Etc , Any Other Item Required To Complete Thethe Work But Not Not Covered Above From 1 To 20 , Operation & Maintenance (O&M) For 10 Years Operation & Maintenance /Cmc (Comprehensive Maintenance Charges) For All The Above Systems Including Data Transmission Charges,Internet Charges,Deployment Of Supervisory Staff,Damaged Equipment/Devices Replacement /Repair Cost /Frequent Requiredcalibration For 10 Years , 1St Year O&M Cost , 2Nd Year O&M Cost , 3Rd Year O&M Cost , 4Th Year O&M Cost , 5Th Year O&M Cost , 6Th Year O&M Cost , 7Th Year O&M Cost , 8Th Year O&M Cost , 9Th Year O&M Cost , 10Th Year O&M Cost