| 1 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit includingremovalof batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified & directed by Engg in Charge |
| 2 | Taking down carefully by unscrewing from boards/outlet boxes,switches,bell push,socket outlets,fan regulators,buzzers,holder and taken as schedule of credit. |
| 3 | Disconnecting and removingthe MCBs,MCCBs,DBs,metal clad switch from any height ,stripping out the fitting for examine replacement of unserviceable spare parts, reassembling, refixing in original position includingminor repairs for the smooth functioning and testing complete all as specified & directed by Engg in Charge. |
| 4 | M&L for attending, repair and rectification ofany type of internal elect supply complaint viz light point/fan point/5/15 Amps switch socket/Submain wiring/MCBs/DBs/no electric supply on 230V/415V system along with necessary T&P, safety devices,without replacement of items as per site requirement and as directed by Engr-in-Charge.Note :1.The contractor shall detail/depute his supvr/electrician to receive the complaints from the concerned complaint cell and rectify the same on the given day alongwith necessary manpower and T & P as required.After completion of the complaints attended, the docket /slips shall be handed over to the concerned complaint cell.2. The cost of the stationery such as complaint register and docket book shall be deemed to be included in the rate quoted. |
| 5 | M & L for Concealed Conduit Point wiring with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V multistranded drawn through conduit and including rigid PVC conduit surface/concealed as required at site and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated hylam sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One light/fan point controlled by one, one way switch 5 amps, SP. |
| 6 | All as per Sl item No 5 here in before, but for One light point controlled by two 2 - wayswitch 5 amps, SP. |
| 7 | All as per Sl item No 5 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 8 | All as per Sl item No 5 here in before, but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 9 | All as per Sl item No 5 here in before, but for OneBell point controlled by one, bell push |
| 10 | All as per Sl item No. 5 here in before, but for using4 Sqmm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 4 Sq mm copper conductorPVC insulated cable as earth continuity conductor. |
| 11 | M & L for Point wiring with 1.5 Sq mm copper conductor single core PVC insulated FRLS 1100 Volts multistranded drawn through and including rigid PVC Casing and Capping as required at site and conduit accessories of suitable dia medium grade in existing MS boxes duly cleaned as per existing site covered with new suitable sheet 3 mm thick for fixing switches / sockets/ regulators etc including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for One light/fan point controlled by one, one way switch 5 amps, SP. |
| 12 | All as per Sl item No. 11 here in before,but for One light point controlled by two 2 - w a ys w i t c h 5 amps, SP. |
| 13 | All as per Sl item No. 11 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 14 | All as per Sl item No. 11 here in before, but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 15 | All as per Sl item No. 11 here in before, but for OneBell point controlled by one, one way switch 5 amps, SP |
| 16 | All as per Sl item No. 11 here in before, but for using4 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 4 Sq mm copper conductorPVC insulated cable as earth continuity conductor. |
| 17 | M & L for Point wiring in concealed conduit complete all as specified with 1100 volts grade 1.5 sqmm PVC insulated FRLS, multistraded copper conductor conforming to IS with ISI marking (For Phase, Neutral and Earth) in and including Non mettalic PVC rigid conduitmedium grade with ISI mark of size 20 mm dia with all accessories concealed in wall/ceiling/roof etc, for fixing modular switches, sockets fan regulators etc of suitable modules and earth wire to be connected to common earth dolly all as specified and directed for the following :Note : Modular cover plate with frame, flush box and modular switches will be inclusive of rate quoted. |
| 18 | All as per Sl item No 17 here in before, but for One light point controlled by two 2 - w a ys w i t c h 5 amps, SP. |
| 19 | All as per Sl item No 17 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 20 | All as per Sl item No 17 here in before, but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 21 | All as per Sl item No 17 here in before, but for OneBell point controlled by one, bell push. |
| 22 | All as per Sl item No. 17 here in before, but for using4 Sqmm single core copper conductor cable of multistranded PVC insulated FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combinationpoint on independent boardincluding running of 4 Sq mm copper conductorPVC insulated cable as earth continuity conductor. |
| 23 | S & F switch piano single pole flush type 5 amps, 230 volts. |
| 24 | S & F switch piano single pole flush type 15 amps, 230 volts. |
| 25 | S & Fsingle pole Modular switch 1 way 6 Amps, 1 Module. |
| 26 | S & Fsingle pole Modular switch 1 way 16 Amps, 1 Module. |
| 27 | S & F Switch piano two way flush type 5 Amps capacity 230 volts. |
| 28 | S & FModular switch 2 way 6 Amps, 1 Module. |
| 29 | S&F bell push 5 A flush type. |
| 30 | S&F Modular Bell Push 6A, 1 Module |
| 31 | Supply and fix socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module. |
| 32 | Supply and fix socket outlet modular type multipurpose 3/5 Pin, 6/16 amps, 230 volts combined 2 Module. |
| 33 | Supply and fix socket outlet flush type multipurpose 2 in 1, 3 Pin, 5 amps, 230 volts all as specified. |
| 34 | Supply and fix socket outlet flush type multipurpose 2 in 1, 3 Pin, 5/15 amps, 230 volts all as specified. |
| 35 | S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1230 Volts all as specified. |
| 36 | S & F switch socket combination 5 in 1 multipurpose 3/5 pin 5/15 amps flush typewith complete all as specified. |
| 37 | S & F Modular ceiling fan regulator stepped socket size (modular) suitable to work on 230 volts complete all as specified, 2 Module |
| 38 | S & F electronic type regulator single module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified. |
| 39 | S & F electronic type regulator two module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified. |
| 40 | S&F bell (buzzer/ding dong) working on 230 volts AC Supply |
| 41 | S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings |
| 42 | S & F wall mounted 2 ft LED batten of 9 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including taking down all as specified and directed by Engg-in-Charge. Make : Havells Cat Part No LUMINEBS9WLED865SPCWH/Bajaj cat Part No BCLSB 10 NW /HPL cat Part No HLPT51510CW. |
| 43 | S & F 4 ft box type tube light fitting with LED Tube rod of 18/22 watt , extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including taking down all as specified and directed by Engg-in-Charge . Make : HavellsCat Part No REGALBATTEN8UPTO1X22WSSBSWH and CRYSTAL1213T8DSTL20WLED865SGLASS/Lukar Cat Part No LLTS1/HPL cat Part No HLPLEDT8PC18CW. |
| 44 | Supply and Fix 4ft LED tube rods of 18/20/22 Watt complete including taking down all as specified and directed by Engg-in-Charge Make: Havells Cat Part No. CRYSTAL1213T8DSTL20WLED865SGLASS. |
| 45 | S & F Security Lights of 1x15 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete including taking down all as specified and directed by Engg-in-Charge.Make : Havells Endura Pearl cat Part No SL15WLED757SASYTOPC/ Lukar Cat Part No LST15/HPL cat Part No HPLLEDSL1560E. |
| 46 | S & F Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all including taking down as specified and directed by Engg-in-Charge.Make : Havells Cat Part No Endura Pearl SL25WLED757SASYTOPCMP/Lukar Cat Part No LST24/HPL Cat Part No HPLLEDSL2560E. |
| 47 | M & L bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete including taking down all as specified and directed by Engg-in-Charge. |
| 48 | S & F 45 watt recess softline luminaire (2x2) suitable for armstrong/grid ceiling with high brightnesswhite LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal and all including taking down as directed by Engg in charge.Make : Havells Cat Part No Venus Neo HE 2x2PLR42WLED857MOD ,LEDDRIVER63V1A42WS/HPL Cat Part No HLPLEDCR040CW. |
| 49 | S & F 10 watt bulk head luminaire suitable for outdoor with high brightness giving glare free light and including taking down all as directed by Engg in charge. Make : Bajaj BIBWP10WLED/Lukar Cat Part No LBKOUSL04/HPL Cat Part No HLPLEDBHIOW(CW). |
| 50 | S & F MCB SP 6 to 32 Amps 240 volts for fixing on MCB DB\"sall as specified. |
| 51 | S & F MCB SP40 to 63 Amps 240 volts for fixing on MCB DB\"sall as specified |
| 52 | S & F MCB SPN 16 to 32 Amps 240 volts for fixing on MCB DB\"sall as specified |
| 53 | S & F MCB SPN 40 to 63 Amps 240 volts for fixing on MCB DB\"sall as specified |
| 54 | MCB Four pole, 415 volts suitable for fixing in MCB DB of capacity63 Amps including removing the existing US one and making good the distrubed surface to match with the existing surface. |
| 55 | MCB Four pole, 415 volts suitable for fixing in MCB DB of capacity100 Amps including removing the existing US one and making good the distrubed surface to match with the existing surface. |
| 56 | S & F sheet metal enclosure MCB DBSPN 4 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified |
| 57 | All as per Sl item No 56 here in before, but SPN 8 way DB |
| 58 | All as per Sl item No 56, here in before but SPN 12 way DB |
| 59 | S & F Horizontal type TPN DB 4 way double door made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as directed by Engr-in-Charge. |
| 60 | S & F Vertical loadline type TPN DB 4 way double door with incoming as MCCB TP 415 volts AC 3 phase50 Hz with fixed magnetic setting for current rating of 100 Amps 16 KA (MCCB TP confirming to IS specification made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as directed by Engr-in-Charge. |
| 61 | S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) all as specified and directed. |
| 62 | S&F MCCBs 415V,25KA, 100 amps 3 Pole suitable for DB including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface. |
| 63 | All as per Sl item No 64 here in before, but 63 Amps, 10 KA. |
| 64 | M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed. |
| 65 | All as per Sl item No 66, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuty conductorNote :For Sl item No 66 to 67: Two runs of cable,one run of earth wire and one run of PVC conduit will be measured as one unit. |
| 66 | All as per Sl item No 67,but 2 runs of single core 4 sqmm and one run of single core 4 sqmm as earth continuty conductor through existing conduit. |
| 67 | All as per Sl item No 67, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuty conductor through existing conduit.Note:-For Sl item No 68 to 69: Two runs of cable,one run of earth wire in existing conduit will be measured as one unit. |
| 68 | M & L Submain wiring with 4 runs of single core 6sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed. |
| 69 | M & L Submain wiring with 4 runs of single core 10sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 10 sqmm PVC insulatedsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed. |
| 70 | Supply and fix 36 Watt CFL 4 pin typecomplete all as specified and directed by Engg-in-Charge. |
| 71 | Supply and fix 18 Watt CFL 2 pin typecomplete all as specified and directed by Engg-in-Charge. |
| 72 | Supply and fix of LED Bulb of 9W. |
| 73 | Supply and replace of CFL Ballast 36 Watts. |
| 74 | Supply and replace Electronic Driver fordownlight as per site requirement all as specified |
| 75 | Supply and replace Electronic Driver for LED Light of2X2 fitting as per site requirement all as specified |
| 76 | Supply and replace starter 40/36/20Watts,230 V. |
| 77 | Supply and replace Bi pin holdersuitable for 40 / 28 Watts tubes(pin & screw type) |
| 78 | Supply and replace CFL holdersuitable for 2/4 PIN for 9 to 36 Watts 40 / 28 Watts tubes(pin & screw type). |
| 79 | Supply and replace Fan condenser 2.5 mfd. |
| 80 | Supply and replace fan condenser of 3.15/4.00 Mfd. |
| 81 | Supply and replace split pins/lock pins for ceiling fans |
| 82 | Supply and replace MS Clamp with rubber bushes, bolts & nuts for ceiling fan along with lock pin all as specified |
| 83 | M & L for repairs to copper inner container like denting, soldering, brazing, leak testing and reassembling of any Ltrs capacity water heater (Geyser) complete all as specified. |
| 84 | Supply and replace Geyser element2000 watts of any type or as per site requirement |
| 85 | Supply and replace Thermostat |
| 86 | Supply and replace Indicator bulb 230 V suitable for any make and colour. |
| 87 | Supply and replace PVC Cold/Hot water connection pipe 45 cms long 15 mm dia |
| 88 | M & L Rewinding of burnt ceiling fan of1200 / 1400mm sweep motor with supper enameled copper wire of suitable size including repainting in white,replacement of sealed bearing and shaft of any make, type, model incl transportationcomplete all as specified and directed by Engineer -in-charge. |
| 89 | M & L Rewinding of burnt Exhaust fan of 225 / 300mm sweep motor with supper enameled copper wire of suitable size including repainting, replacement of sealed bearing and shaft of any make, type, model incl transportationcomplete all as specified and directed by Engineer -in-charge. |
| 90 | S&F ceiling fan downrod of required heightincluding drilling of holes and threads for the same as per the site requirement all as direted by Engineer-in-charge. |
| 91 | S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified. |
| 92 | Supply and replace PVC Round blocks. |
| 93 | Supply and replace PVC Dummy sheets circular type of 4\". |
| 94 | Supply and replace PVC Dummy sheets circular type of 6\". |
| 95 | Supply and replace Rigid PVC casing & capping 20/25 mm wide. |
| 96 | Supply and replace PVC rectangular box (Gang box) with 5 Amps switch socket. |
| 97 | Supply and replace PVC rectangular box (Gang box) with 5/15 Amps switch socket. |
| 98 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GIearth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate). |
| 99 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earting etc as required 4mm dia galvanised iron or steel wire. |
| 100 | Supply and fix/lay GI pipe 15 mm dia med grade for protection of earth continuity conductor. |
| 101 | Supply and replace PVC wire of Flexible cord with copper conductor multistanded of twin core 23/0.198sqmm |
| 102 | Supply and replace PVC insulated FRLS copper wire of size 1.5 sq mm multistranded 1100 volts grade |
| 103 | Supply and replace PVC insulated FRLS copper wire of size 2.5 sq mm multistranded 1100 volts grade |
| 104 | Supply and replace PVC insulated FRLS copper wire of size 4.0 sq mm multistranded 1100 volts grade |
| 105 | Supply and replace PVC insulated FRLS copper wire of size 6.0 sq mm multistranded 1100 volts grade |
| 106 | Supply and replace Service wire twin core of 10.0 sq mm multistranded 1100 grade |
| 107 | Supply and replace Plug top 5 Amps 3 pin 250 Volts |
| 108 | Supply and replace Plug top 15 Amps 3 pin 250 Volts |
| 109 | M&Lfor Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges ofandings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealedconduit wiring, etc., and making good, cutting not exc 10 cm girth. |
| 110 | Supply and fix white hylam plain laminate sheet ofthickness as per the site requirement and as directed by Engr-in-Charge. . |