Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #31044977

Repair To Sunken Portion, Leakage, Seepage To Roof And Repair To Wall / Ceiling Plaster To Bldgs Of Jcos / Or Md Qtrs Of Aoc Centre And Of Other Than Mh Area I.E 54 Dou, 60 Coy, 54 Inf Div, 654 Eme Bn, 554 Asc Bn, Md Accn Of Old Assay Lines And Saf

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
45 Lakhs
Estimated cost
Bid Submission
09 Mar 2022
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair To Sunken Portion, Leakage, Seepage To Roof And Repair To Wall / Ceiling Plaster To Bldgs Of Jcos / Or Md Qtrs Of Aoc Centre And Of Other Than Mh Area I.E 54 Dou, 60 Coy, 54 Inf Div, 654 Eme Bn, 554 Asc Bn, Md Accn Of Old Assay Lines And Safilguda Repair To Sunken Portion, Leakage, Seepage To Roof And Repair To Wall / Ceiling Plaster To Bldgs Of Jcos / Or Md Qtrs Of Aoc Centre And Of Other Than Mh Area I.E 54 Dou, 60 Coy, 54 Inf Div, 654 Eme Bn, 554 Asc Bn, Md Accn Of Old Assay Lines And Safilguda

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-Mar-2022

BOQ

Name of Work:REPAIR TO SUNKEN PORTION, LEAKAGE, SEEPAGE TO ROOF AND REPAIR TO WALL/CEILING PLASTER TO BLDGS OF JCOS/OR MD QTRS OF AOC CENTRE AND OF OTHER THAN MH AREA i.e 54 DOU, 60 COY, 54 INF DIV, 654 EME BN, 554 ASC BN, MD ACCN OF OLD ASSAY LINES AND SAFILGUDA SHO, 454 FD AMB AREA UNDER AGE B/R (S) NO. II OF GE (S) SECUNDERABAD.
Sl. No. Item Description
1Roughening the surfaces of old concrete roof surfaces by picking,sweeping clean and washing down with water to remove dust etc including removal of old treatement of any description and removing the debris to a distance of exc 50 m away from Plinth protection of the building all as specified and as directed.
2M& L 10mm thick rendering in CM 1:4 using water proofing compund at the rate of 3% weight of cement over concrete surfaces. NOTE ; WPC will be measured and paid separately.
3M&L priming the plastered roof surfaces with bitumenous primer @ 0.30 kg over applying hot bitumen VG-30 1.2kg/Sqm and applying APP based polymeric membrane weighing 3 kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150gms/per sqm) and on primed surface by forced torch application over that applying bitumen base alluminium Paint 0.2 Kg/Sqm complete all as spescified all as specified and as directed.
4Supply only water proofing compund ISI mark as approved by GE.
5M&L 40mm Thick PCC (1:2:4) TYPE B1 by using 20mm graded stone aggregate as in roof , where required ober slabs inclufing necessary form work and finishing the exposed surfaces fair even all as specified and as directed.
6M&L cutting grooves in brick wall of size 75mm wide 65mm deep and shapping to horizontal face of the groove with cement mortar 1:3 all as specified and as directed.
7Disconnecting existing tanks setting aside ( or laying if required) for carry out the roof repair cleaning and removing all scale & dirts etc from tanks & hoisting reconnecting & refixing with all new GI fittings in old or new position of the tank capaacity exc 250 Ltrs & n.exc 500 ltrs all as specified and as directed,
8Disconnecting existinng tanks setting aside ( or laying if required) for carry out the roof repair cleaning and removing all scale & dirts etc from tanks & hoisting reconnecting & refixing with all new GI fittings in old or new position of the tank capacity exc 500 Ltrs & n.exc1000 ltrs all as specified and as directed.
9S& F Rotational moulded PVC water storage tank hoisted and fixed in positon of 500 ltrs capacity incl dismantling existing water tanks all as specified and as directed.
10S& F Rotation moulded PVC water storage tank hoisted and fixed in position 1000 ltrs capacity incl dismantling existing water tanks all as specified and as directed.
11S&F in repairs 20mm Ball valves high pressure of PTMT with epoxy coated aluminium rod and high dessity plastic ball screwed for iron pipe and fixed ( minimum weight 455 gms) all as specified and as directed.
12S&F 20mm Ball valves high pressure of PTMT with epoxy coated aluminium rod and high dessity plastic ball screwed for iron pipe and fixed ( minimum weight 455 gms) all as specified and as directed.
13Taking up or down steel tubing and connections of 15mm dia complete all as aspecified.
14ditto- all as per item No 13 above but of 20mm dia all as specified and as directed.
15S&F 15MM dia steel water tubing medium grade galvanised with all fittings & fixing complete to walls & ceilings or laid in floors all as specified and as directed.
16S&F 20MMsteel water tubing medium grade galvanised with all fittings & fixing complete to walls & ceilings or laid in floorsall as specified and as directed.
17Refixing of 15mm old steel tubing with new connections in new or old position (Walls, ceiling, floors, etc.) with all new GI fittings all as specified and as directed.
18Refixing of 20mm old steel tubing with new connections in new or old position (Walls, ceiling, floors, etc.) with all new GI fittings all as specified and as directed.
19S&F in repairs 20mm dia bore Gun metal gate valve with iron wheel head screwed both ends for iron pipe 20mm bore
20Taking down plastering on brick/ Stone walls etc including racking out joints, hacking for key, scrabing down with water etc upto a height of 8Mtrs including necessary scaffolding all as specified and as directed.
21M & L 15mm thick rendering with as in CM 1:4 for fair faces of Brick works or Concrete surfaces and finishing even and smooth without using extra cementareas complete all as specified and as directed by Engineer-in-Charge Note: Patchwork upto a height of 8Mtrs including necessary scaffolding.
22M & L for 15 mm thick rendering in Cement Mortar 1:6 on fair faces of Brick works or Concrete surfaces and finishing even and smooth without using extra cementNote: Patchwork upto a height of 8Mtrs including necessary scaffolding.
23M & L rendering 10mm thick cement mortar plaster in CM 1:3 on concrete surfaces on ceiling including finishing even and smooth w/o using extra cement Note: Patchwork upto a height of 8Mtrs including necessary scaffolding.
24M & L Preparation of newly plastered surfaces of walls and applying two coats ofcement base paint over a coat of Primer.
25M & L for preparing new plastered surfaces of walls and applying 2 coats of OBD on new surface of walls over a coat of Primer and 3mm thick wall care putty complete all as specified and directed..NOTE : oil emulsion distemperwill be done by roller only, after complete removal of old looseflakes.
26M & L for applying three coats of white wash on ceiling including preparation of new plastered surfaces complete all as specified and as directed.
27Demolition of un reinforced cement concrete in ground floors and paving n.exc 15 cm thickness (below & above ground level) complete all as specified and as directed.
28M & Lproviding cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in roof curves or muds, stops, rounded or chamfered on edges complete all as specified and as directed.
29Demolition of brick/stone masonry work built in cement mortar including all quions, arches, pillars etc complete.
30M & L for brick work in CM (1:6) using old size sub class \"B\" bricks straight or curved on plan all as specified and directed.
31M & L for brick work with sub class \"B\" bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 all as specified and directed.
32S & F in repairs vitreous china squatting pan \"Orissa pattern\" size 580 x 440mm white with integral foot rest including replacement of \"P\" or \"S\" trap lime concrete bedding and making good floors complete all as specified and directed.
33S&Fin repairs EWC Pedestal pattern WC ,any colourinclEWC seat Cover,10 ltr capacity PVC ,LLFC,32 mm dia PVC flush pipe including stainless steel Toilet Paper holder etc complete all as specified and directed.
34S & F (in repairs) PVC low level flushing cistern 10 litres capacity, syphonic action type, white, as approved including ball valve float valve and handle, flush pipe as in repair complete all as specified and directed.
35S & F (in repairs) vitreous china, wash hand basin white size 550 x 400 mmincluding brackets, chromium plated waste coupling & PVC waste pipe of 32mm dia complete all as specified and directed.
36Taking down PVC pipe any dia/type and setting aside for repair
37S&F P V C (SWR) pipes of 110 mm bore single socketed in any length fixed to wall all as specified and directed.
38S&F P V C (SWR) pipes of 75 mm bore single socketed in any length fixed to wall all as specified and directed.
39Taking down PVC (SWR) fittings any type/dia viz bends, tee, branch piece etc
40S&F 75mm PVC (SWR) floor trap plain with grating incl jointing with solvent cenment all as specified and directed.
41S&F 110mm PVC (SWR) WC connector with lip ring.
42S&F PVC (SWR) bends any radius 75mm bore provided with access door all as specified and directed.
43S&F PVC (SWR) bends any radius 110MM bore all as specified with access doorand directed.
44S&F 110mm bore PVC (SWR) vent cowl.
45S&F PVC (SWR) junction single, (Single T) equal or un equal 110 mm bore of any radius with access door all as specified and directed.
46M&L for PCC 1:2:4 type B-1 using 20mm graded aggregate as in cills, coping steps, tank staging, sesmic and other similar courses, lacing courses parapet and railing upto 60cm ht kneeler kerb and alike including weathering, slightly rounded or chemfered angle and throating as directed.
47M&L rendering 15mm thick in CM 1:3 on brick work or concrete surfaces, mixed with integral water proofing compound as per manufactures instructions, finished even and smooth without using extra cement.After plastering the sunken surface, sunken portion to be filled with water and tested for 72 hrs (after required peirod of curing) to observe leakage/seepages, leakge/seapage if any shall be arrested by pressure grouting and re-tested till leakages/seapages completely stopped.after ponding test, the surface shall be dried and bottom and sides of the sunken slab shall be treated, priming the plastered surface with bituminous primer conforming to IS-3384 @ 0.3 kg per Sqm and applying a tack coat of industrial butiumen 85/25 @ 1.2 kg per Sqm over which applying using glass fibre base bituminous felt type II and grade 2 (conforming to IS-7193 1994) and applying one coat of hot blown bitumen of grade 85/25 @ 1.2 kg per Sqm including 450mm long 25mm dia medium grade GI pipe shall be provided at the lowest portion Spout pipe should be 200mm from the external face of wall for draining out water in case of leakage.The joints in CI/GI/PVC pipes, nahani traps, WC and P/S trap connection shall be made leak proof.The gap around the pipes in walls/beams shall be properly filled and sealed with water proof joints fillers all as specified and directed by Engineer-in-Charge.
48M&L for PCC 1:4:8 type D-2 using 40 mm graded brick aggregate as in filling of sunken portion etc complete all as specified and directed. .
49M & L for preparing Old plastered surfaces of walls and applying 2 coats of OBD complete all as specified and directed.NOTE : oil emulsion distemperwill be done by roller only, after complete removal of old looseflakes.

AI Tender Summary

OUR REF NO 31044977
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 09-03-2022
Authority
Authority Name Military Engineer Services
Work Description Repair To Sunken Portion, Leakage, Seepage To Roof And Repair To Wall / Ceiling Plaster To Bldgs Of Jcos / Or Md Qtrs Of Aoc Centre And Of Other Than Mh Area I.E 54 Dou, 60 Coy, 54 Inf Div, 654 Eme Bn, 554 Asc Bn, Md Accn Of Old Assay Lines And Safilguda Repair To Sunken Portion, Leakage, Seepage To Roof And Repair To Wall / Ceiling Plaster To Bldgs Of Jcos / Or Md Qtrs Of Aoc Centre And Of Other Than Mh Area I.E 54 Dou, 60 Coy, 54 Inf Div, 654 Eme Bn, 554 Asc Bn, Md Accn Of Old Assay Lines And Safilguda
Basic Detail
Tender No GE (S)/SEC/TOKEN - 65 OF 2021 - 22
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 02 Mar 2022
Submission Date 09 Mar 2022
Open Date 11 Mar 2022
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
0ad9224f-5cd1-4b94-b6b2-34eb16309118.html
8461tender.pdf
BOQ_566822.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 02, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 09, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 09, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 11, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0ad9224f-5cd1-4b94-b6b2-34eb16309118.html

pdf

8461tender.pdf

xls

BOQ_566822.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail