Public Health Engineering Department-PHED has published Various Electro-Mechanical Works To Be Carried At Wss Jawalapora.- 1 Supply, Installation, Testing And Commissioning Ofopen Wellclear Watersubmersible Pumping Units Of Following Specifications To Be Installed In The Sump As Per Is: 14220 / 1994• Pump:-. Submission Date for this Tender is 17-02-2022. Kitchen Equipment Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

31038267
Various Electro-Mechanical Works To Be Carried At Wss Jawalapora.- 1 Supply, Installation, Testing And Commissioning Ofopen Wellclear Watersubmersible Pumping Units Of Following Specifications To Be Installed In The Sump As Per Is: 14220 / 1994• Pump:-
Open Tender
Indian
Jammu And Kashmir
srinagar
17-02-2022

Tender Details

Various Electro-Mechanical Works To Be Carried At Wss Jawalapora.- 1 Supply, Installation, Testing And Commissioning Ofopen Wellclear Watersubmersible Pumping Units Of Following Specifications To Be Installed In The Sump As Per Is: 14220 / 1994• Pump:-Discharge :- 10000 Gphhead:-104Mtrsspeed :2900 Rpm Type Of Pump: Open Well Type Submersibleimpeller As Per Oemquality Of Water To Be Handled:-Clear Water The Material Of Construction For Pump, Bearings, Sleeves, Casting, Wear Rings, Pump Shaft And Suction Casing Shall Suit To Handle Specifications Detailed Above.• Motor Type :-Submersible Rating :Suitable For Above Parametersmethod Of Starting : Star Delta / Soft Startspeed: -2900 Rpmvoltage :415 V + 15 % Class Of Insulation : Suitable For Above Ratingthe Submersible Motor Shall Be Squirrel Cage Induction Type And The Winding Shall Be Wet Type. The Motor Windings And Bearing Bushes Of The Rotary Shall Be Cooled / Lubricated By Water. The Pumping Unit Shall Have Name Plate Enumerating All Technical Details Of The Unit. The Job Also Includes Supply / Fabrication And Fitting Of Suitable Size Gi Nipples For Pumps. The Nipples Shall Be Threaded On One Side As Per Outlet Of Pump And Welded With Suitable Size Ms Flange As Per The Size Of Rising Main. The Unit Shall Include All Fittings Like Coloumn Pipe From Pump To Delivery Manifold, Bends, Nuts-Bolts, Gaskets, Washers Etc For Connection With Delivery Manifold As Per The Actual Requirement At Site During Execution Of Job.Fabrication Providing & Fitting Of Split Type Ms Clamps 8Mm Thick, 4” Wide And2.5 Feet Longfor Lowering Of Column Pipes And Holding Of Pumping Unit After Lowering. The Job Includes The Cost Of Required Size Of Nuts And Bolts Of Required Length ( 01 Number For Each Unit ) The Item Shall Be Supported With Test Certificate, Performance Curves From Oem ( Original Equipment Manufacturer ) Besides Conforming The Material Of Construction. ( Moc ) 2 P / F Of 16 Sq. Mm, 3 Core Submersible Copper Cable For Open Well Submersible Pumping Equipment From Panel Board To Pumps. 3 P / F Of 25Sq. Mm, Single Core Copper Cable For Interconnection Of Electrical Equipments Pump House. ( As Per Is Code ) 4 Fabrication / Providing / Fitting And Testing Of Modular Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Steel Sheet Having Required Openings / Vents And Fitted With Accessories As Under :- ( Is Code Iec 60947 / 2020 ) • Change Over Switch : Front Operated / On Load / 04 Pole Type: Cos-400 Rating: 400 Amp / 415 V + 15 % , 50 Hz + 3 % Quantity: 01 No• Main Circuit Breaker : Mccbthermal Release Range ( Amp ) : 400 Amp Breaking Capacity: 415 V Ac, 50 Hz : 50 Ka No Of Poles : 04 Qty : 01 No• Circuit Breaker On The Input Of Starters : Mccbthermal Release Range ( Amp ) : 250-320Breaking Capacity: 415 V Ac, 50 Hz : 36 Ka No Of Poles : 03 Qty : 02 No• Starter Relay Range: 45-75Amppower Specs: 415 V + 15 % , 50 Hz + 3 %Qty : 02 No• Ampere Metersize : 96 Mm Sq ( 0 – 150 ) Amp Type : Digital 3 Ph Led Ammeter Class 1 Qty : 02 No• Volt Meter Size : 96 Mm Sq ( 0 – 500 ) V Type : Digital 3 Ph Led Voltmeter Class 1 Qty : 02 No • Frequency Meter Type : Led Freq Meter Class 0.2 Qty : 01 No• Neon Indicators ( Ryb ) Qty : 03No• Bus Bars : Electrolytic Aluminium For 400 Amp Rating With Proper Tapping 5 P / I / T / Comm. Of 75 Kva Voltage Stabilizer Of Following Specifications:-A ) Type:-Manually Operated Oil Cooled B ) Capacity:- 75 Kvac ) No Of Phases:- 3 No Of Phases, 50 Hz Frequencyd ) Operating Conditions:-1 ) Input 180 Volts +10% To 440 Volts+10% On 3 Phase Ac Supply 2 ) Out Put :- 440 Volts + 10% 3 Phase Ac Supplye ) Terminals:- Three No Incoming And Three No Outgoing Terminals F ) Core:- The Voltage Stabilizer Shall Be Fitted With High Permeability Core For Efficient Heat Dissipation And The Core Strips Shall Be Held Together Firmly And Fitted On Bracket Of Suitable Size And Thicknessg ) Coils:- Three No Copper Wound Coils Shall Be Fabricated Out Of Copper Conductor With Cotton Tapping.H ) Voltage Regulator:- The Voltage Stabilizer Shall Be Fitted With 6 / 8 Steps Three Phase Stepping Up Voltage Regulator Double Plate Disc Type Having Copper Contact Pointsi ) Panel:- The Indicating Panel Shall Be Fitted On The Top Side Ofvoltage Stabilizer Fabricated Out Of Suitable Thickness Ms Sheetand Fitted With Volt Meterand Indication Lamps.J ) Meters :-Volt Meters - Size : 96 Mm Sq - Type : Digital 3 Ph Led Voltmeter Class 1- Qty : 02 No With Phase Selecting Optionk ) Enclosure:- The Whole Assembly Shall Be Enclosed In Ms Tank Of Suitable Thickness, Floor Mounted . L ) Coolant:-Thestabilizer Shall Be Filled With A- Gradet – Oil Up Torequired Level.The Item Shall Be Supported With Test Report / Certificate From Equipment Manufacturer Confirming To Relevant Is Code. 6 Providing, Fitting, Testing And Commissioning Of Xlpe Armoured Al. Cable Of 1.1 Kv Grade With Following Characteristics: Conductor Nominal Area : 50 Mm2min. Number Of Wires :3 ½ To Be Fitted From Change Over Panel To Modular Panel. The Job Also Includes P / F Of Aluminumthimbles Of Various Sizes As Per Size Requirement Including Crimping And Taping 7 Providing, Fitting, Testing And Commissioning Of Non Return Valve As Per Following Specifications : ( Is 5312 ) • Nominal Dia : 125 Mm• Rating : Pn 16• Body : Ductile Iron • Corrosion Protection – Epoxy Coatingeachvalve Shall Be Provided With 02 No Matching Flanges 8 Providing, Fitting, Testing And Commissioning Of Gate / Sluice Valve As Per Following Specifications: ( Is 14846 / 2000 Is 778 ( 1984 ) • Nominal Dia : 125 Mm• Type : Eko Plus • Rating : Pn 16• Body : Ductile Iron • Corrosion Protection – Epoxy Coating Eachvalve Shall Be Provided With 02 No Matching Flanges 9 Fabrication / Providing / Fitting Of Delivery Manifold With Wash Out Arrangement Fabricated Out Of ( Class – C ) Gi Pipe 125 Mm And Welded With 18 Mm Thickms Flange As Per Table – 5 In Two Runs Of Welding . The Job Also Includes Cost On Account Of Suitable Size Nuts, Bolts And Rubber Packing In The Flanged Joints. The Job Shall Also Include Providing And Fitting Of 125Mm C Class Gi Pipe ( 12 Mtrs ) For Fabrication Of Y Junction And Washout Arrangement Including Cost Of Flanges Rubber Gaskets Nuts Bolts, Bends, Welding Works Wherever Required. 10 Fabrication / Erection Of Channel Iron Column To Act As Support For Resting Of Monorail Crane As Per Following Details:- The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint.Vertical Posts = Ismc 200No. Of Vertical Posts = 02 Nos.Vertical Channel Section Each Post= 02 Nos ( Seam Welded Face To Face ) .Vertical Post Bracing = Ismc 100Sole / Matching Plates = 500X300x12 Thickheight Of Vertical Posts = 5 Msize Of Vertical Post Concrete Blocks = 600X600x900 Mm ( Depth ) Concrete Grade = M20welding Electrode = Overcord Ss Of Adore / Esab / L&T / Advanimonorail Section = Ishb 250Length Of Monorail = 5Msteel Detail :I. Ismc 200 5Mx2x2 = 20 M @ 22.3Kg / M = 446 Kgii Ismc1000.25Mx8x2x2 = 8 M@ 9.2Kg / M = 73.60 Kgiii Plate0.500X0.300X8 ( 12Mmthk ) = 1.20 M² ( 12Thk ) = 112.80 Kgiv Monorail Ishb250 5 M @ 51.4 Kg / M = 257Kgsv Bolts / Nuts ( L.S ) =30Kgstotal = 919.4 Kg Say 920 Kg. 11 Supply, Installation And Testing Of 02 Ton Capacity, Manually Operated Chain Pulley Block. The Chain Pulley Block Shall Have 6 M Lift. It Shall Also Include Suspension Arrangement Made Of 10 Mm Steel Wire Rope Or Gi Wire Capable Of Supporting Rated Load And 2 No. D-Shackles ( With Nut Locking System ) For Fitment Of Chain With Suitable Size. 12 Supply And Installation Of 1000 Va Inverter Of Reputed Make For Charging Battery Of Dg Set Installed At Water Supply Scheme. The Job Also Includes Supply Of 12 V, 180 Ah Battery Complete With Leads, Terminals And Thimbles. The Job Includes All The Charges On Account Of Carriages, Wiring And Arrangement Of Skilled Labour For Installation Of Inverter. The Job Also Includes Wiring Switches And Sockets Etc. 13 Electrification Of Pump House By Way Of P / F Of:-Lighting Points, Bulk Head Type In 1.0 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 5 Amp. Switch, Angle / Button Holder, 9 W Led Lampwith Necessary Fixtures – ( 06 Jobs ) Heating Points In 2.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. The Job Incl. P / F Of 16 Amp.Ss Combine Duly Fitted In Modular Boards- ( 04 Jobs ) 5-Pin Socket Points In Modular Board In 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit.- ( 04 Jobs ) Indicator Pointsin 1.0 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit – ( 04 Jobs ) Ceiling Fan With Regulator Switch, Wiring In 1.5 Sq Mm Multi Strand Pvc Insulated Copper Conductor To Be Laid / Carried In Pvc Channel / Conduit. And Necessary Fixtures. – ( 01 Job ) Distribution Board Sp & N ( Regal Grey ) With 01 No Incoming And8 Way Outgoing, Fitted With Mini Mcb “C” Series 6A - ( 04 No ) For Lighting Points And 2 / 3 Pin Socket Points And Fans, 10 A – ( 02 No ) For Flood Lights, 16 Amp – ( 02 No ) For Heating Points, 63 Amp Mcb ( For Mains ) Of Reputed Make. The Job Also Includes P / F Of Wall Mounted 60 W Led Lamps With Fixtureslike Switches, Covers, Arms Etc ( 04 No.’S ) Including Wiring As Per Site Requirement .The Fittings Shall Be Modular Type Of Reputed Make 14 Supply And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 155 Mm, Top 65Mm, Thickness 3 Mm With Zinc Coating With Inside Arrangement For Providing Of Power Connection With Following Items:• 02 No Terminal Connector 60 Amp• Required Size Duly Crimped Lugs• 04 No Foundation Bolts Of Required Size And Length With Nuts• Cement Concreting Of Required Size But Not Less Than ( 50 X 50 X 100 ) Cm In 1 : 2 : 4 Ratio• Required Length 1.5 Sq Mm Multi Strandpvc Insulated Copper Conductor• Mounting Arrangement For Fixing Flood Lights• Service Line From Panel To Pole In 2.5 Sq Mm Multi Strandpvc Insulated Copper Conductor To Be Laid Underground Through Alkathine Sleeve – Length As Per Site Requirement 15 Supply, Installation, Testing And Commissioning Of Pressure Die Cast Aluminum Integral Led Flood Lights As Per Specifications Below • Rating – 48 W 16 The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below &Shall Be Of Make:Flat Spannerof Size ( 4 / 5 To 30 / 32 ) : ( 01 Complete Set ) Ring Spanner Set Of Size ( 12 / 13To 30 / 32 ) : ( 01 Complete Set ) Cutting Pliers, 10 Inch: ( 01 No ) Cutting Pliers, 12 Inch: ( 01 No ) Nose Pliers 9 Inch: ( 01 No ) Rechargeable Torch : ( 02 No ) Multimeter: ( 01 No ) Screw Driver 18 Inch / 12 Inch / 9 Inch: ( 02 No`S Each ) Hammer, 1 Kg, 2 Kg : ( 01 No Each ) Pipe Wrench 12 Inch / 18 Inch / 24 Inch : ( 01 No Each ) Rechargeable Torch: ( 02 Nos ) Bamboo Ladder ( 25 Feets Long ) : ( 01 Nos ) Bamboo Link Rod ( 20 Feets ) : ( 01 Nos ) Electric Shock Proof Hand Glows’: ( 02 Pairs ) The Tools Are To Be Provided In A Strong Tool Box With Key And Lock. 17 Providing / Mountingof 4.5 Kg Carbon Dioxide Fire Extinguishers Conforming To Is: 2878, Suitable And Effective For Controlling Electric, Machinery And Oil Generated Fires ( B&C Class Of Fires ) . The Fire Extinguishers To Have A Suitable Hose Pipe Of Sufficient Length. The Job Includes Mounting The Fire Extinguishers On The Walls Conveniently In The Vicinity Of Machinery By Way Of Fixing The Ms Clamps And Angle Iron Of Suitable Size On The Walls. 18 Providing, Installation Of Earthing Station Comprising Of Company Fabricated Earthing Electrodes As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Black Fill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result The Job Includes P / F Ofgi Strip Shall Be Fitted On Baby Insulators And Clamps. Safe Earthing Electrode Size 50 Mm Dialength - 1500Mmblackfill - 30 Kg 19 Supply, Installation, Testing & Commissioning Of 82.5 Kva – 3 Phase Water Cooled D.G. Set. The Dg Set Shall Be Suitable For 1600M-Amsl Altitude, -100C To +400C Temperature And 60% Relative Humidity. The Dg Set Shall Comprise Of Diesel Engine And Alternator Coupled Together And Fitted With Standard Accessories, Control Panel, Battery, Anti Vibration Pads, Ms Canopy Duly Painted And Conforming To Noise Pollution Specifications. The Dg Set Should Be Rated For Continuous Duty With Overload Provision Of 10% For The Period Not Exceeding One Hour In Twelve Hours. The Dg Set Shall Comprise Ofa ) Alternator The Alternator Shall Be Self Excited. Self Regulated For Desired Rating. The Alternator Shall Be Fitted With High Performance Avr And Suitable For Continuous And Trouble Free Operation.Specifications1 ) Rated Output At Above Site Conditions :- 82.5Kva 2 ) Rated Speed :- 1500 Rpm 3 ) Efficiency:-88.8%4 ) Voltage:- 415 V At 50 Hz B ) Diesel Engine ( Prime Mover ) The Engine Shall Be Diesel Driven To Develop Requisite Bhp At 1500 Rpm For The Alternator Rated As Above At An Altitude Of 1600M Amsl With Ambient Temperature Ranging From 100C To +400C Under 60% Humid Conditions. Specifications:- 1 ) Speed:- 1500Rpm2 ) No. Of Cylinders :- 043 ) Aspiration:- Tc4 ) Cooling System;-Water Cooled 5 ) Method Of Start: - 12 Volt Electric Start.The Engine Shall Be Fitted With Following Accessories. 1 ) Fuel Tank:-Suitable Capability For Twelve Hours Continuous Running On Full Load. The Fuel Tank Shall Be Floor Mounted Type Made Of M.S Sheet Duly Painted And Fitted With Inlet / Outlet Return Connections, Air Vent, Drain Valve, Level Indicator And Fuel Pipes 2 ) Battery:- 01 No, 12 Volt Along With Leads And Terminals Connected With Charging Dynamo And Cut Out Fitted With Suitable Rating Starting System.3 ) Alternate Battery Charging Arrangement: - 850 Va Inverter 4 ) Safety Control: - In Order To Shut Down The Engine In The Event Of High Water Temperature. It Shall Also Be Fitted With Ant Vibration Pads, Cold Starting Aid, Safety Control For Low Lube Pressure Etc. 5 ) Radiator:- Suitable Size C / W Hoses, Clamps Etc.C ) Standard Control Panel:- It Shall Be Fabricated Out Of Steel Sheet 1.5Mm Thick Duly Pretreated And Aesthetically Finished. It Shall Be Totally Enclosed, Dust, Vermin Proof With Ip-53 Degree Of Protection As Per Is 2147-62. The Panel Shall Consist Of Following Instruments.1 ) ( 0-600 ) V-Ac Voltmeter Of Class 1.5 Accuracy With Phase Selector Switch. 2 ) Ac- Ammeter Of Class 1.5 Accuracy.3 ) Hrc Fuses Of Suitable Rating.4 ) One No. Mccb / Mcb Of Suitable Rating 5 ) Pilot Lamps6 ) Push Button Switch For On-Off Operation.7 ) It Shall Also Be Fitted With Starting Switch With Keys, Lube Oil Gauge, Temp. And Pressure Gauge, Speedometer And Hour Meter Etc.All The Above Components Shall Be Properly Mounted Duly Wired And Shall Be Of Reputed Make.D ) Canopy:-M.S. Canopy Of Suitable Thickness, Duly Painted, Able To Withstand Snow Load And Able To Control Noise Pollution, Is To Be Fitted To The D.G. Set.E ) First Filling Of Hsd:- The Dg Set Shall Be Provided With First Filling Of Hsd. The Fuel Tank Shall Be Filled Upto 90% Of Tank Capacitye ) Miscellaneous:-Technical Literature And Catalogue Is To Be Provided. The Job Includes Earthing Of Dg Set As Per Norms And Site Conditions & Requisite Cables Etc For Inter Connection To Commission The Dg Set. The Job Includes 70Mm2 Al., 3.5 Core 40 Metres Cable For Fitment Of Dg Set To Changeover Switch With Proper Thimbling. The Job Also Includes Providing And Fitting Of Flexible Canvas Sleeve / Conduit For Carrying Conductor. The Job Also Includes Cement Concrete Foundation As Per The Standards Of Oem / Site Requirement With Minimum 3 Feet Above Ground Level And 2 Feet Extending Beyond Size Of Dg Set On Each Side. 20 Supply Of Basic Facilities To The Staff Comprising Of:Matting Comprising Of 12 Mm Thermo Cool, Jute Matting / Excel, Floor Blankets – 150 Sft Eachbedding Comprising Of Mattress, Quilt, Excel Blanket, Pillow – 03 Sets.Cooking And Bathroom Items As 05 Ltr Pressure Cooker, 2.8 Ltr Rice Cooker, Pan, Aluminum Cooking Vessels – 02 No, Steel Plates – 04 No, Steel Glass ( Tumblers ) – 04 No, Cooking Spoons – 02 No, Cups – 04 No, Plastic Jug, Electric Heater, Kerosene Stove, 20 Ltr Plastic Buckets – 02 No, 1 Ltr Plastic Mugs – 02 No, Heavy Duty Plastic Chairs -04 No And Table 01 No. Make ) Chargeable Lantern Andslite Make – 01 No. Gas Stove With Domestic Gas Cylinder – 14 Kg Capacity Complete With Gas Pipe And Regulator And Papersheat Convector / Heating Blower – 01 No. ( With Metal Enclosure ) 21 Providing And Fabrication Of Retiring Bed For Operational Staff. The Bed Is To Be Fabricated Out Of Isa ( 50X50x6 ) Mm. The Bed Should Be 6 Feet Long, 4 Feet Wide And 1.25 Feet High. Also 03 No. Supports Fabricated Out Of 25X5mm Ms Strips Shall Be Provided And Welded To Support 19 Mm Thick Ply Board To Be Fitted On Top. 22 Painting Of Gantry, Pipe Network ( Inside The Premises Of Pump House ) Andall The Metal Surfaces Except Cgi Sheeting And Purlins By Applying A Coat Of Anticorrosive ( Red Oxide ) And Then Two Coats Of Synthetic Enamel Paint. 23 Providing / Laying Of 3Mm Thick High Density Anti Skid Rubber Floor Mating On The Machine Floor Level Area

Key Value

Document Fees
INR 500 /-
EMD
INR 66630.0 /-
Tender Value
INR 22.21 Lakhs /-

BOQ Items

Name of Work: Various Electro-Mechanical works to be carried at WSS Jawalapora.
Sl. No. Item Description
1Supply, installation, testing and commissioning ofopen wellclear waterSubmersible pumping units of following specifications to be installed in the sump as per IS: 14220/1994 • PUMP:- Discharge :- 10000 GPH Head:-104Mtrs Speed :2900 rpm Type of pump: Open well type submersible Impeller As per OEM Quality of water to be handled:-Clear Water The material of construction for pump, bearings, sleeves, casting, wear rings, pump shaft and suction casing shall suit to handle specifications detailed above. • MOTOR Type :-Submersible Rating :Suitable for above parameters Method of starting : Star Delta / Soft start Speed: -2900 rpm Voltage :415 V + 15 % Class of Insulation : Suitable for above rating The submersible motor shall be squirrel cage induction type and the winding shall be wet type. The motor windings and bearing bushes of the rotary shall be cooled / lubricated by water. The Pumping Unit shall have name plate enumerating all technical details of the unit. The job also includes Supply/Fabrication and fitting of suitable size GI nipples for pumps. The nipples shall be threaded on one side as per outlet of pump and welded with suitable size MS flange as per the size of rising main. The unit shall include all fittings like Coloumn Pipe from Pump to delivery manifold, Bends, Nuts-Bolts, Gaskets, Washers etc for connection with delivery manifold as per the actual requirement at site during execution of job. Fabrication providing & fitting of split type MS Clamps 8mm thick,4” wide and2.5 feet longfor lowering of column pipes and holding of pumping unit after lowering. The job includes the cost of required size of nuts and bolts of required length (01 number for each unit) The item shall be supported with test certificate, performance curves from OEM (original equipment manufacturer) besides conforming the material of construction. (MOC)
2P/F of 16 sq. mm, 3 core submersible copper cable for open well submersible pumping equipment from panel board to pumps.
3P/F of 25sq. mm, single core copper cable for interconnection of electrical equipments pump house. (as per IS code)
4Fabrication / Providing / Fitting and testing of Modular control panel of appropriate size fabricated out of 14 SWG steel sheet having required openings / vents and fitted with accessories as under :- (IS code IEC 60947/2020) • Change over switch : Front operated / On load / 04 pole Type: COS-400 Rating: 400 Amp / 415 V + 15 % , 50 Hz + 3 % Quantity: 01 No • Main Circuit breaker : MCCB Thermal release range ( Amp ): 400 Amp Breaking Capacity: 415 V AC, 50 HZ : 50 KA No of poles : 04 Qty : 01 No • Circuit Breaker on the input of starters : MCCB Thermal release range ( Amp ): 250-320 Breaking Capacity: 415 V AC, 50 HZ : 36 KA No of poles : 03 Qty : 02 No • Starter Relay Range: 45-75Amp Power Specs: 415 V + 15 % , 50 Hz + 3 % Qty : 02 No • Ampere Meter Size : 96 mm sq ( 0 – 150 ) Amp Type : Digital 3 Ph LED Ammeter Class 1 Qty : 02 No • Volt meter Size : 96 mm sq ( 0 – 500 ) V Type : Digital 3 Ph LED Voltmeter Class 1 Qty : 02 No • Frequency meter Type : LED Freq meter Class 0.2 Qty : 01 No • Neon Indicators (RYB) Qty : 03No • Bus Bars : Electrolytic Aluminium for 400 Amp Rating with proper tapping
5P/I/T/Comm. of 75 KVA voltage stabilizer of following specifications:-a)Type:-Manually operated oil cooled b)Capacity:- 75 KVA c)No of phases:- 3 No of phases, 50 HZ frequency d) Operating conditions:- 1) Input 180 volts +10% to 440 volts+10% on 3 phase AC supply 2) Out put :- 440 volts + 10% 3 phase AC supply e) Terminals:- Three No incoming and three no outgoing terminals f) Core:- The voltage stabilizer shall be fitted with high permeability core for efficient heat dissipation and the core strips shall be held together firmly and fitted on bracket of suitable size and thickness g) Coils:- Three no copper wound coils shall be fabricated out of copper conductor with cotton tapping. h) Voltage regulator:- The voltage stabilizer shall be fitted with 6/8 steps three phase stepping up voltage regulator double plate disc type having copper contact points i)Panel:- The indicating panel shall be fitted on the top side ofvoltage stabilizer fabricated out of suitable thickness MS sheetand fitted with volt meterand indication lamps. j) Meters :-Volt meters - Size : 96 mm sq - Type : Digital 3 Ph LED Voltmeter Class 1- Qty : 02 No with phase selecting option k) Enclosure:- The whole assembly shall be enclosed in MS tank of suitable thickness, floor mounted . l) Coolant:-Thestabilizer shall be filled with A- gradeT – oil up torequired level. The item shall be supported with test report/certificate from equipment manufacturer confirming to relevant IS code.
6Providing, fitting, testing and commissioning of XLPE Armoured Al. Cable of 1.1 KV grade with following characteristics: Conductor Nominal area : 50 mm2 Min. Number of wires :3 ½ To be fitted from change over panel to modular panel. The job also includes P/F of Aluminumthimbles of various sizes as per size requirement including crimping and taping
7Providing, Fitting, Testing and Commissioning of Non Return Valve as per following specifications : (IS 5312) • Nominal Dia : 125 mm • Rating : PN 16 • Body : Ductile iron • Corrosion protection – Epoxy Coating Eachvalve shall be provided with 02 no matching flanges
8Providing, Fitting, Testing and Commissioning of Gate / Sluice Valve as per following specifications: (IS 14846/2000 IS 778(1984) • Nominal Dia : 125 mm • Type : EKO PLUS • Rating : PN 16 • Body : Ductile iron • Corrosion protection – Epoxy Coating Eachvalve shall be provided with 02 no matching flanges
9Fabrication / Providing / Fitting of Delivery Manifold with wash out arrangement fabricated out of (Class – C )GI pipe 125 mm and welded with 18 mm thickMS flange as per Table – 5 in two runs of welding . The job also includes cost on account of suitable size nuts, bolts and rubber packing in the flanged joints. The job shall also include providing and fitting of 125mm C class GI pipe (12 mtrs) for fabrication of Y junction and washout arrangement including cost of flanges rubber gaskets nuts bolts, bends, welding works wherever required.
10Fabrication / Erection of Channel iron column to act as support for resting of monorail crane as per following details:- The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint. Vertical Posts = ISMC 200 No. of vertical posts = 02 Nos. Vertical channel section each post= 02 Nos (seam welded face to face). vertical post bracing = ISMC 100 Sole / Matching plates = 500x300x12 thick Height of vertical posts = 5 M size of vertical post concrete blocks = 600x600x900 mm(Depth) Concrete grade = M20 welding Electrode = Overcord SS of Adore/ESAB/L&T/Advani Monorail Section = ISHB 250 length of monorail = 5M Steel Detail : i. ISMC 200 5Mx2x2 = 20 M @ 22.3kg/m = 446 kg Ii ISMC1000.25Mx8x2x2 = 8 M@ 9.2kg/m = 73.60 kg iii Plate0.500x0.300x8 (12mmthk) = 1.20 M²(12thk) = 112.80 kg Iv Monorail ISHB250 5 M @ 51.4 kg/M = 257kgs V Bolts/Nuts (L.S) =30kgs Total = 919.4 Kg say 920 Kg.
11Supply, installation and testing of 02 ton capacity, manually operated chain pulley block. The chain pulley block shall have 6 m lift. It shall also include suspension arrangement made of 10 mm steel wire rope or GI wire capable of supporting rated load and 2 No. D-Shackles (with nut locking system) for fitment of chain with suitable size.
12Supply and installation of 1000 VA inverter of reputed make for charging battery of DG set installed at water supply scheme. The job also includes supply of 12 V, 180 Ah battery complete with leads, terminals and thimbles. The job includes all the charges on account of carriages, wiring and arrangement of skilled labour for installation of inverter. The job also includes wiring switches and sockets etc.
13Electrification of Pump House by way of P/F of:- Lighting points, bulk head type in 1.0 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 5 Amp. switch, angle / button holder, 9 W LED lampwith necessary fixtures – (06 jobs) Heating points in 2.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. The job incl. P/F of 16 Amp.SS combine duly fitted in modular boards- (04 jobs) 5-pin socket points in modular board in 1.5 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit.- (04 jobs) Indicator pointsin 1.0 sq mm multi strandPVC insulated copper conductor to be laid / carried in PVC channel/conduit – (04 jobs) Ceiling Fan with regulator switch, wiring in 1.5 sq mm multi strand PVC insulated copper conductor to be laid / carried in PVC channel/conduit. and necessary fixtures. – (01 job) Distribution Board SP & N ( Regal Grey ) with 01 No incoming and8 way outgoing, fitted with mini MCB “C” series 6A -(04 No) for lighting points and 2/3 pin socket points and fans, 10 A – (02 No) for flood lights, 16 Amp – (02 No) for heating points, 63 Amp MCB ( For Mains ) of reputed make. The Job also includes P/F of Wall mounted 60 W LED lamps with fixtureslike Switches, Covers, arms etc (04 No.’s) including wiring as per site requirement . The fittings shall be modular type of reputed make
14Supply and erection of 9 mtr long hot dip galvanized octagonal pole ( Single Section ) with bottom 155 mm, top 65mm, thickness 3 mm with Zinc coating with inside arrangement for providing of power connection with following items: • 02 No terminal connector 60 Amp • Required size duly crimped lugs • 04 No foundation bolts of required size and length with nuts • Cement concreting of required size but not less than (50 x 50 x 100) cm in 1 : 2 : 4 ratio • required length 1.5 sq mm multi strandPVC insulated copper conductor • Mounting arrangement for fixing flood lights • Service line from panel to pole in 2.5 sq mm multi strandPVC insulated copper conductor to be laid underground through alkathine sleeve – Length as per site requirement
15Supply, Installation, Testing and commissioning of pressure die cast aluminum integral LED flood lights as per specifications below • Rating – 48 W
16The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below &shall be of make: Flat Spannerof Size (4/5 to 30/32) :(01 complete set) Ring Spanner Set of Size (12/13to 30/32):(01 complete set) Cutting Pliers, 10 inch: (01 No) Cutting Pliers, 12 inch: (01 No) Nose Pliers 9 inch: (01 No) Rechargeable torch : (02 No) Multimeter: ( 01 No) Screw Driver 18 inch /12 inch / 9 Inch:( 02 No`s Each ) Hammer, 1 Kg, 2 kg : (01 No each) Pipe Wrench 12 inch / 18 inch / 24 inch : (01 No each ) Rechargeable torch:(02 nos) Bamboo Ladder (25 feets long):(01 Nos) Bamboo Link rod (20 feets):(01 nos) Electric Shock proof Hand glows’:(02 Pairs) The tools are to be provided in a strong tool box with key and lock.
17Providing/ Mountingof 4.5 Kg carbon dioxide fire extinguishers conforming to IS: 2878, suitable and effective for controlling electric, machinery and oil generated fires (B&C class of fires ). The fire extinguishers to have a suitable hose pipe of sufficient length. The job includes mounting the fire extinguishers on the walls conveniently in the vicinity of machinery by way of fixing the MS clamps and angle iron of suitable size on the walls.
18Providing, Installation of earthing station comprising of company fabricated earthing electrodes as per IS: 3043. The job includes Auguring of bore of required dia / depth for installation of electrode along with black fill compound mixed with soil and all other items required thereof for achieving the best result The job includes P/F ofGI strip shall be fitted on baby insulators and clamps. Safe earthing electrode size 50 mm dia length - 1500mm Blackfill - 30 Kg
19Supply, Installation, Testing & Commissioning of 82.5 KVA – 3 Phase water cooled D.G. Set. The DG set shall be suitable for 1600m-AMSL altitude, -100C to +400C temperature and 60% relative humidity. The DG Set shall comprise of diesel engine and alternator coupled together and fitted with standard accessories, control panel, battery, anti vibration pads, MS canopy duly painted and conforming to noise pollution specifications. The DG Set should be rated for continuous duty with overload provision of 10% for the period not exceeding one hour in twelve hours. The DG set shall comprise of A)ALTERNATOR The alternator shall be self excited. Self regulated for desired rating. The alternator shall be fitted with high performance AVR and suitable for continuous and trouble free operation. SPECIFICATIONS 1)Rated Output at above Site Conditions :- 82.5KVA 2)Rated Speed :- 1500 rpm 3) Efficiency:-88.8% 4) Voltage:- 415 V at 50 Hz B)DIESEL ENGINE (Prime Mover) The engine shall be diesel driven to develop requisite BHP at 1500 rpm for the alternator rated as above at an altitude of 1600m AMSL with ambient temperature ranging from 100C to +400C under 60% humid conditions. Specifications:- 1) Speed:- 1500rpm 2) No. of cylinders :- 04 3) Aspiration:- TC 4)Cooling system;-water cooled 5) Method of start: - 12 volt electric start. The engine shall be fitted with following accessories. 1) Fuel tank:-suitable capability for twelve hours continuous running on full load. The fuel tank shall be floor mounted type made of M.S sheet duly painted and fitted with inlet/outlet return connections, air vent, drain valve, level indicator and fuel pipes 2) Battery:- 01 No, 12 volt along with leads and terminals Connected with charging dynamo and cut out fitted with suitable rating starting system. 3)Alternate Battery Charging Arrangement: - 850 VA inverter 4) Safety control: - In order to shut down the engine in the event of high water temperature. It shall also be fitted with ant vibration pads, cold starting aid, safety control for low lube pressure etc. 5) Radiator:- Suitable Size C/W hoses, clamps etc. C) Standard control panel:- It shall be fabricated out of steel sheet 1.5mm thick duly pretreated and Aesthetically finished. It shall be totally enclosed, dust, vermin proof with IP-53 degree of protection as per IS 2147-62. The panel shall consist of following instruments. 1) (0-600) V-AC Voltmeter of class 1.5 accuracy with phase selector switch. 2) AC- Ammeter of class 1.5 accuracy. 3) HRC fuses of suitable rating. 4) One No. MCCB/MCB of suitable rating 5) Pilot lamps 6) Push button switch for ON-OFF operation. 7) It shall also be fitted with starting switch with keys, Lube oil gauge, Temp. and pressure gauge, Speedo meter and hour meter etc. All the above components shall be properly mounted duly wired and shall be of reputed make. D) Canopy:-M.S. Canopy of suitable thickness, duly painted, able to withstand snow load and able to control noise pollution, is to be fitted to the D.G. Set. E) First Filling Of HSD:- The DG set shall be provided with first filling of HSD. The fuel tank shall be filled upto 90% of tank capacity E) Miscellaneous:-Technical literature and catalogue is to be provided. The job includes earthing of DG set as per norms and site conditions & requisite cables etc for inter connection to commission the DG set. The job includes 70mm2 AL., 3.5 core 40 metres cable for fitment of DG set to Changeover switch with proper thimbling. The job also includes Providing and Fitting of flexible canvas sleeve / conduit for carrying conductor. The job also includes Cement Concrete Foundation as per the standards of OEM / site requirement with minimum 3 feet above ground level and 2 feet extending beyond size of DG set on each side.
20Supply of basic facilities to the staff comprising of: Matting comprising of 12 mm thermo cool, jute matting/ excel, floor blankets – 150 sft each Bedding comprising of mattress, quilt, excel blanket, pillow – 03 sets. Cooking and bathroom items as 05 ltr pressure cooker, 2.8 ltr rice cooker, pan, aluminum cooking vessels – 02 No, steel plates – 04 No, Steel glass ( tumblers) – 04 No, cooking spoons – 02 No, Cups – 04 no, Plastic Jug, Electric heater, Kerosene stove, 20 ltr plastic buckets – 02 No, 1 ltr plastic mugs – 02 No, Heavy duty plastic chairs -04 No and table 01 No. make) Chargeable lantern Andslite make – 01 No. Gas stove with domestic gas cylinder – 14 kg capacity complete with gas pipe and regulator and papers Heat convector / Heating Blower – 01 No. (with metal enclosure)
21Providing and Fabrication of retiring bed for operational staff. The bed is to be fabricated out of ISA (50x50x6) mm. the bed should be 6 feet long, 4 feet wide and 1.25 feet high. Also 03 No. supports fabricated out of 25x5mm MS strips shall be provided and welded to support 19 mm thick ply board to be fitted on top.
22Painting of gantry, pipe network(inside the premises of pump house) andall the metal surfaces except CGI sheeting and purlins by applying a coat of anticorrosive (Red Oxide) and then two coats of synthetic enamel paint.
23Providing/laying of 3mm thick high density anti skid rubber floor mating on the machine floor level area