Military Engineer Services-MES has published Repair / Maintenance Of Dg Sets Amf Panels, Solar Water Heaters And Its Connected Items At Jalipa Mil Station Under Ge Army Barmer. Submission Date for this Tender is 12-03-2022. Diesel Generators Tenders in barmer Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 05-Mar-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-03-2022 |
Sl. No. | Item Description |
1 | M&L for maintanence and servicing of 250 KVA Diesel genarator sets installed at 81 Armd Pump house Make : cumminsincluding connected Alternator and carryng out routine "A" check of the engine and servicing works as listed below for smooth functioning all as per manufactures instructions and as directed. (a) To check (every 50hrs/1 month wichever is earlier) (1) Lubrication greasing to all parts (ii) Check all engine level (b) Fuel system : Drain sediment from fuel tanks. (c) Air System: every 50hrs/1 month wichever is earlier (i) Clean pre Cleaner dustpan weekly (ii) Check Air cleaner restriction clean/change cleaner element if required. (d) Cooling system: Check coolent level OTHER MAINTENANCE: (i) Drainer tank (ii) Check and correct leaks (iii) Drain fuel filter.Water separator. (iv) Check belts & adjust if required Note: Engine oil/Radiator coolent oil top up will be measured and paid separately. |
2 | All as per item No.1 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House |
3 | All as per item No.1 here in before but 82.5 KVA installed at 13 Grd Pump house |
4 | All as per item No.1 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre,22 grd and jalipa Pump House |
5 | All as per item No-1 but 20 KVAat 22 Grd Pump house |
6 | All as per item No-1 but 30 KVAinstalled at BdePump House |
7 | M&L for carring out following periodical maintanence on 250 KVA Diesel genaratorsets installeed at 81Armd Pump House (a) To check (every 250 Hrs/Every 6 month) (i) Repeat "A" Lubrication(ii) Changing Engine Oil (iii) Record oil pressure. (b) Fuel system : (i) Check Hydrulic Governor oil. (ii) Check throttle linkage.(iii)Lubricant Ball joints of the throttle linkage ofHydrulic Governor. (iv) Change of Fuel filter. (v) Clean fuel tank breather.. (c) Air System: (i) Clean / Change cranckcase Breather. (ii) Check Air Pipings/durettes (d) COOLING SYSTEM: (i) Check coolant in radiator.(ii) Add coolant concentrate if required(maintaining pH value in between 7.5 to10.5) (iii) Check heat exchanger zinc (sacrificial Anode) plugs. Note: (i) Coolant oil, Engine oil utilised will be measured and paid separatly. (ii) The rate quoted must be inclusive of the necessary oil filter, fuel filter , air filter units and thegaskets, O rings and clips required for changing of the filter elements |
8 | All as per item No.07 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House |
9 | All as per item No.07 here in before but 82.5 KVA installed at 13 Grd Pump house |
10 | All as per item No.07 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre, 22 Grd and jalipa Pump House |
11 | All as per item No-07 but 20 KVAat 22 Grd Pump House. |
12 | All as per item No-07 but 30 KVAinstalled at BdePump House |
13 | M&L for Removing the unserviceable display unit from the control panel and supply and fix in repair display unit (LCD) in the control panel of 100 KVA DG set including connecting with the necessary wiring with soldering and testing after fixing complete all as specified and as directed. |
14 | M&L for servicing of Self Starter assyby disconnecting from engine and dismantling the same cleaning all accessories , replace the wornout partslike :- brushes, bushes , contact plates, jumping leads and seals, revarnishing the field coil , armatureand reassembling the same , refitting the engine and testing of250 KVA DG setcomplete all as directed |
15 | All as per item No.14 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House |
16 | All as per item No.14 here in before but 82.5 KVA installed at 13 Grd Pump house |
17 | All as per item No.14 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre, 22 Grd and jalipa Pump House |
18 | All as per item No-14 but 20 KVAat 22 Grd Pump House. |
19 | All as per item No-14 but 30 KVAinstalled at BdePump House |
20 | M&L for Removing the U/S battery and supply and fix moulded PVC body low maintanence lead acid battery 12 volts 180 AH Make: Exide. |
21 | M&L for Removing the U/S battery and supply and fix moulded PVC body low maintanence lead acid battery 12 volts 130 AH Make: Exide. |
22 | Supply and filling/top upengine oil SAE 15 W - 40 [CH grade)[Make : VOLVOLINE ] |
23 | Supply and filling/top up Radiator coolant[Make : VOLVOLINE ] |
24 | M&L for Removing the unserviceable battery charger and supply and fix in repair external battery charger 12 V DC at DG set room at Jalipa main pump house including necessary connections and testing completeall as directed . |
25 | M&L for Overhauling of radiator assy of DG set 250 KVA by disconnecting and removing from eingine , dismantling the top & bottom chambers , descalling the sediments and scales , corrosion ..etc by means of acid cleanig and high pressure water washing , air cleaning , re assembling the same with new gaskets, including arresting leakage , if any and fixing to the engine with new hoses ,clips as reqd |
26 | All as per item No.25 here in before but 100 KVA installed at MES pump house, Bde pump house,81 Long term Pump house and Jalipa Pump House |
27 | All as per item No.25 here in before but 82.5 KVA installed at 13 Grd Pump house |
28 | All as per item No.25 here in before but 62.5 KVA installed at Main Pump House, MH, Signal Centre |
29 | All as per item No-25 but 20 KVAat 22 Grd Pump House. |
30 | All as per item No-25 but 30 KVAinstalled at BdePump House |
31 | Supply onlyfan belts as per exisiting make for 250 KVA capacities of DG Sets. |
32 | All as per item No-31here in beforebut 100 KVA . |
33 | All as per item No-31here in beforebut 82.5/62.5 KVA . |
34 | All as per item No-31here in beforebut 20/30 KVA . |
35 | Supply only Solenoid switch, 24 Volts, Suitable for 100 KVA DG SET |
36 | Supply only Engine control Unit [ IN-NT-PLUS] 24 Volts, Suitable for 100 KVA DG SET |
37 | M & L for sevicing and calibration of governor unitin-si-tu including replacement of worn out parts if any and testing it for a maximum droop of 20% complete all as specified and as directed for 250 KVA DG set |
38 | All as per item No-37here in beforebut 100 KVA . |
39 | All as per item No-37here in beforebut 82.5/62.5 KVA . |
40 | All as per item No-37here in beforebut 20/30 KVA . |
41 | Supply and fix Tacho drivemeter includingcableassembly 1.5 mtr length [0.200]RPM [Make : KOEL/VDO] |
42 | Supply and replace Brass, Batteryterminals |
43 | M&L for Repair and servicing of 250 KVA PT pump assembly and injectors by replacing the unserviceable parts like centre shaft, loading spring, relief valve-2 Nos bearings.governor barrels & plunger-1Set O-ring kits,gasket kit,injector plunger & barrel -6Nos,ball check -6Nos and calibration and phasing of injectors and FIP in test bench andreassemblingetc as required. |
44 | All as per item No-43here in beforebut 100 KVA . |
45 | All as per item No-43here in beforebut 62.5 KVA . |
46 | All as per item No-43here in beforebut 30/20 KVA . |
47 | M&L for Taking down Geyser of any capacity/type from existing position for repair /cleaning/ descaling of inner tank with descaling solution/wire brush, sand paper and refixing the same after repair complete all as specified and as directed. (Spares will be measured and paid separately under relevant items) |
48 | M&L for Taking out the unserviceable heating element and supply and fix in repair heating element 2000 W round Type complete all as specified and as directed. |
49 | M&L for Taking out the unserviceable heating element and supply and fixing in repair heating element 2000 W triangular type complete all as specified and as directed. |
50 | M&L for Taking out the unserviceable thermostat and supply and fixing in repair thermostat for 25/50 Ltr cap geyser and making connection complete all as specified and as directed. |
51 | M&L for Taking out the unserviceable red/green indicator lamps and supply and fixing in repair indicator lamp any type/size 230 Volt complete all as specified and as directed. |
52 | M&L for Taking out the unserviceable safety valve and supply and fixing safety valve ISI maked for any type geyser complete all as specified and as directed. |
53 | M&L for Taking out the unserviceable non return valve and supply and fixing inrepair non return valve vertical type chrome plated ISI marked in suction line of geyser complete all as specified and as directed. |
54 | M&L for Taking out the old toggle bolts and supply & fix in repair ground toggle bolts (tower/anchor), 4" long along with washers and nuts for fixing geysers 25/50 ltrs capacity. |
55 | M&L for Taking out the unserviceable PVC connection pipes and supply & fix in repair PVC metal braided connection pipes for hot water supply with brass adopters 450mm long. |
56 | M&L for Taking out the unserviceable PVC connection pipes and supply & fix in repair PVC metal braided connection pipes for hot water supply with brass adopters 600mm long. |
57 | M&L for Taking out the unserviceable plug tops and supply & fix in repair plug top 3 pin 15A ISI marked |
58 | M&L for Taking out the unserviceable connecting cableand supply & fix in repair copper cable flexible 3 core PVC insulated of size 50/0.25 (2.5 Sq mm) |
59 | Comprehensive maintenance and repairs of Solar Water HeatingSystem consisting of Solar Water Heater Tank with Stand, Flat Plate Collector (Copper based), Electircal Coil (for backup), Non Return Valve at Inlet and Outlet, Pressure Release Valve etc complete of 10 Nos of 200 LPD capacities with electric back up (Cost of any minor spares shall be borne by the contractor):- |